Search PubMedSearch

SEARCH · Search PubMed

Results for “Microfluidic Analytical Techniques”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

154 records · Page 2Linked to original sources

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3 mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100 ng/mL (R2 ≥ 0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within ±15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Development and validation of a novel LC-MS/MS method for simultaneous quantification of fidaxomicin and metabolite (OP-1118) from feces for gut pharmacobiome studies.

Fidaxomicin is a first-line antibiotic for treating Clostridioides difficile infection. While it has low systemic absorption and reaches high colonic concentrations, it is hydrolyzed to a less active metabolite, OP-1118. Few studies have completely described critical experimental details of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantifying fecal fidaxomicin and OP-1118. This study developed and validated a simple, fast, and sensitive LC-MS/MS method to quantify fidaxomicin and OP-1118 in human and mouse feces. This method simplified fecal sample preparation without the use of solid phase extraction and optimized LC-MS/MS parameters. A broad working range (0.3-1000&#xa0;ng/ml) in both diluted human and murine fecal matrices was achieved with good intra- and inter-day accuracy (93-107%), precision (1-7%), and recovery (70-105%) as well as little IS-normalized matrix effects. This method was utilized to quantify fidaxomicin and OP-1118 in human and murine fecal samples. This novel method was simple, fast, sensitive, and accurate in analyzing fecal fidaxomicin and OP-1118 and could be deployed to facilitate gut pharmacobiome research.

Feces

Validated UPLC-MS/MS quantification and intracellular PK-PD Modeling of periplocin-related cardiac glycosides in H/R-injured H9c2 cells.

Reliable intracellular quantification is essential for characterizing the target-site disposition and exposure-response relationships of bioactive natural products. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of periplocin and four related cardiac glycoside metabolites in H9c2 cell lysates. Acceptable linearity, precision, recovery, and stability were achieved for intracellular quantification. Cells were treated with each compound at 50&#xa0;&#x3bc;M, and intracellular concentrations and cell viability were monitored over 48&#xa0;h. In hypoxia/reoxygenation (H/R) -injured cells, the time to maximum intracellular concentration was shortened for all five compounds, indicating altered cellular disposition under injury conditions. Cell viability was improved by all compounds during the observation period. Pharmacokinetic-pharmacodynamic (PK-PD) integration was performed using a sigmoid Emax model, and acceptable model fits were obtained, with Akaike information criterion (AIC) values ranging from 79.22 to 130.46. Low apparent EC50 values were estimated under this single-dose design, whereas the estimated Ke0 values suggested delayed equilibration with the effect compartment. These findings indicate that sustained cytoprotective responses can be produced by periplocin and related metabolic markers in injured cardiomyocytes. This intracellular bioanalytical strategy provides a quantitative approach for linking cellular exposure to pharmacodynamic response and may support further evaluation of periplocin-related cardiac glycosides.

Tandem Mass Spectrometry

Quantifying the aromatic amino acid metabolome: UPLC-MS/MS analysis of aromatic amino acids and their host and co-metabolites in plasma.

Aromatic amino acids (AAAs), tryptophan, phenylalanine, and tyrosine along with their pathway metabolites have been implicated in the pathogenesis of diseases ranging from cardiovascular, neurological, inflammatory, and cancer diseases, among others. As such, the measurement of the primary AAAs, their host pathway metabolites, and microbiome derived co-metabolites in blood can provide a sensitive reflection of systemic health. The aim of the study was to develop a method for the quantification of 17 metabolites, the three AAAs and various of their metabolites in plasma using a high-throughput ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method. The method demonstrated a dynamic range (1 to 16,700&#xa0;ng/mL), with detection limits (LOD) as low as 0.05&#xa0;ng/mL. Quantification limits ranged from 3 to 5019&#xa0;ng/mL (LLOQ) and up to 16,700&#xa0;ng/mL (ULOQ). Recovery at LQC, MQC, and HQC was satisfactory and consistent across most metabolites, with significant matrix effects observed only for 4-ethylphenol sulfate. Furthermore, intra and inter-day accuracy and precision met all acceptance criteria at all quality control concentrations for most of the metabolites. Measurement of NIST SRM 1950 showcased the method's accuracy for most of the metabolites. Finally, the method was applied on the analysis of plasma samples from 55 individuals (13 males and 42 females) providing information on AAAs and their pathway metabolites relevant concentrations in human plasma.

Amino Acids, Aromatic

Improved comprehensive profiling of fecal bile acids through chemical derivatization combined with HPLC-MS/MS analysis.

Bile acids (BAs) facilitate the digestion and absorption of fats and influence lipid and glucose homeostasis, making them potential therapeutic targets for obesity and related metabolic disorders. The liver and intestinal microbiota modify BAs structurally, generating diverse chemical forms and isomers. Comprehensive profiling of the BA pool is critical for understanding their key biological functions and as a therapeutic approach for related diseases. High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is usually chosen as the preferred method for BA detection due to the complex chemical structures, the wide range of actual concentrations and the complexity of fecal sample matrices. However, free BAs are difficult to ionize, resulting in low detection signals and a lack of characteristic structural fragments to assist in structural identification. In this method, the labeling reagent (2-aminoethyl) trimethylammonium (AETMA) is employed to label the carboxyl group of BAs. Compared with underivatized BAs, the detection sensitivity of unconjugated BAs was enhanced by 25-180 fold, while that of conjugated BAs increased by 6-160 fold. It also generates unique fragment ions and enhances MS response, facilitating the discovery of potential BAs. Methodological parameters were validated using 38 BAs as representatives. Through methodological validation, it was verified that the precision, recovery, matrix effect and stability parameters of the method met acceptable criteria. We also identified 61 confirmed BAs and 55 additional candidate BAs in human pooled fecal samples. It has been successfully applied to fecal BA analysis in obese populations, providing valuable insights into potential therapeutic strategies for obesity.

Tandem Mass Spectrometry

A versatile reversed-phase liquid chromatography charged aerosol detection method for streamlined monitoring of QS-21 content and stability in liposomal adjuvant formulations.

Identifying and quantifying an active adjuvant along with its degradants in drug formulations is essential for ensuring the safety and efficacy of the drug product. QS-21 is a potent adjuvant that is being evaluated in several clinical trials and is currently formulated in licensed vaccines that protect against shingles, malaria, and RSV. In aqueous environments, QS-21 is subject to hydrolytic degradation that is influenced by pH and temperature, resulting in the formation of a degradant known as QS-21 Hydrolyzed Product, QS-21 HP, which can occur during manufacturing and/or prolonged storage. The intact QS-21 and QS-21 HP induce distinct immune response profiles, making it critical to monitor the degradation of QS-21 in vaccine adjuvant formulations. To date, there has been a paucity of reliable assays for QS-21, its isomers, and degradant QS-21 HP in liposomal adjuvant formulations available that can be transferred seamlessly in quality control (QC) environments. Herein, we introduce a simple and QC-friendly liquid chromatography coupled to a charged aerosol detector (LC-CAD) enabled by stationary phase screening combined with in silico method development optimization. The method exploits 2.7&#xa0;&#x3bc;m fused-core phenyl hexyl particles, ensuring its versatility in standard and ultra-high pressure LC systems. This approach demonstrates a high correlation between predicted retention time (RT) and experimental outcomes with overall &#x2206;RT&#xa0;<&#xa0;4%. In addition, this assay shows great linearity, precision, specificity, and accuracy to advance process development characterization of new vaccine formulations.

Liposomes

A validated sensitive LC-MS/MS method and its application in elucidating the unique ocular pharmacokinetic profile of 0.01% atropine underpinning its clinical utility for myopia.

A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify atropine in ten rabbit ocular tissues enabling systematic characterization of the ocular pharmacokinetic profile of 0.01% atropine sulfate eye drops after a single topical administration. The method demonstrated excellent linearity (coefficient of determination, R2&#xa0;&#x2265;&#xa0;0.9908) across all matrices, with lower limits of quantification (LLOQ) of 0.05&#xa0;ng/mL for most tissues and 0.10&#xa0;ng/mL for retina and lens; intra- and inter-day accuracy, precision, matrix effects, extraction recoveries, and stability all met the acceptance criteria. Following a single bilateral topical dose (50&#xa0;&#x3bc;L/eye) in New Zealand White rabbits, atropine distributed rapidly into all 12 ocular compartments (the sclera further divided into three anatomical regions) with marked heterogeneity-the highest exposures were found in conjunctiva and cornea, a distinct anterior-to-posterior concentration gradient was observed in the sclera, sustained retention was noted in the retina (mean residence time from zero to the last measurable time point, MRT0-t 3.30&#xa0;h), while aqueous and vitreous humor eliminated rapidly (elimination half-life, t&#x2081;/&#x2082;&#xa0;<&#xa0;0.7&#xa0;h), and all tissues except aqueous humor followed a two-compartment model. This validated method and the comprehensive pharmacokinetic data reveal that topically applied 0.01% atropine achieves sustained exposure in key myopia-regulating tissues (retina, choroid, posterior sclera) with low exposure in side-effect target tissues (iris, ciliary body, lens).

Animals

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000&#xa0;nM. However, due to carry-over observed at 10,000&#xa0;nM, the validated calibration range was established at 1-2000&#xa0;nM, with matrix-dependent LLOQs of 1-10&#xa0;nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

Selective monitoring of trace-level catechin and myricetin in herbal and aqueous matrices using magnetic MIP-DSPME: Optimization via design of experiments.

A novel dispersive solid-phase microextraction approach utilizing a magnetic molecularly imprinted polymer (MMIP) integrated with HPLC-UV detection was developed for the concurrent quantification of catechin and myricetin in herbal extracts and aqueous samples. The sorbent was engineered as a core-shell nanocomposite, consisting of a selective polymer layer deposited onto Fe3O4@SiO2-APTMS magnetic nanoparticles. Dual-template imprinting using catechin and myricetin generated complementary binding cavities within the polymer framework. Experimental variables influencing extraction were systematically screened and subsequently optimized. A Plackett-Burman design was first applied to identify the most influential factors, with pH and sorption time identified as the dominant variables. These parameters were subsequently fine-tuned using a central composite design, and the optimization process was completed in only 30 experimental runs. The sorption characteristics of the imprinted sorbent (MMIP) were compared with those of its non-imprinted counterpart (MNIP). The MMIP demonstrated markedly higher maximum binding capacities (Qmax), reaching 119.3&#xa0;mg&#xa0;g-1 for myricetin and 112.1&#xa0;mg&#xa0;g-1 for catechin, whereas the corresponding values for the MNIP were 32.55 and 32.08&#xa0;mg&#xa0;g-1, respectively. Moreover, the affinity constants (KL&#xa0;=&#xa0;0.760-0.950&#xa0;L&#xa0;mg-1) were approximately 2.3-fold higher for the MMIP, confirming its stronger and more selective interactions with the target analytes. The selectivity coefficients for the targeted flavonoids relative to structurally related compounds, including ferulic acid, p-coumaric acid, melatonin, and curcumin, exceeded 3.5 for the MMIP, whereas the corresponding values for the MNIP were close to 1.1, demonstrating the high molecular recognition capability of the imprinted sorbent. Method validation demonstrated limits of detection (LODs) of 0.33-0.59&#xa0;ng&#xa0;mL-1 and limits of quantification (LOQs) of 1.10-1.96&#xa0;ng&#xa0;mL-1, and excellent linearity over the concentration range of 5.0-5500&#xa0;ng&#xa0;mL-1 (R2&#xa0;>&#xa0;0.998). The method achieved recoveries of 93.96% to 105.69% with RSDs below 5.5%, while the preconcentration factors ranged from 209 to 229. Furthermore, the sorbent retained more than 95% of its extraction efficiency after four consecutive reuse cycles and more than 80% after six cycles, demonstrating excellent stability and reusability. The proposed method was successfully applied to the analysis of six medicinal plant extracts and water samples, showing negligible matrix interference and superior sensitivity, selectivity, and operational simplicity compared with conventional solid-phase extraction methods.

Flavonoids

How I do it: 3-Suture robotic pyeloplasty: Step-by-step technique.

Robot-assisted pyeloplasty is now a gold standard in the treatment of pediatric ureteropelvic junction obstruction. We describe a standardized "3-suture" technique designed to facilitate the pyelo-ureteral anastomosis. We used this technique in 65 paediatric patients aged 3-17 years. Early major complications (Clavien-Dindo grade III) occurred in 3 patients (4.6%). The median operative time was 150 min. Surgical success was achieved in 96% of cases at a median follow-up of 9.5 months. This 3-suture approach offers a highly reproducible method for robotic pyeloplasty, facilitating accurate anatomical reconstruction with excellent surgical outcomes.

Humans

Cardiovascular risks in psychiatric disorders and psychiatric risks in cardiovascular disorders: implications for prevention and clinical management - a large-scale umbrella review encompassing 76 meta-analyses.

OBJECTIVE: Psychiatric and cardiovascular disorders often co-occur, complicating their assessment and management. No umbrella review(UR) has summarized the meta-analytic evidence on the co-occurrence of psychiatric and cardiovascular disorders and assessed its credibility. METHODS: Meta-analytic systematic reviews of observational studies documenting the prevalence, risk factors, and outcomes associated with the co-occurrence of cardiovascular and psychiatric disorders, indexed from inception through March.16.2026, and meeting established diagnostic criteria, were included. Meta-analytic association and prevalence estimates were recalculated and graded based on established or adapted criteria. The AMSTAR-2 assessed the quality of the meta-analyses, while several subgroup analyses and meta-regressions aimed to explain the heterogeneity. RESULTS: We included 76 meta-analyses yielding 131 meta-analytic estimates. Based on pre-existing meta-analytic evidence, 22/24 prevalence estimates (91.7%) met moderate/strong credibility criteria. Strong credibility emerged for: orthostatic hypotension in Lewy body(58%;95%C.I.&#xa0;=&#xa0;50-66%) and Alzheimer's dementias(28.0%&#xa0;=&#xa0;95%C.I.&#xa0;=&#xa0;17.0-40.0%); pericardial effusion in anorexia nervosa(25.0%;95%C.I.&#xa0;=&#xa0;17.0-34.0%); in heart failure(HF): major depressive disorder(MDD)(41.9%;95%C.I.&#xa0;=&#xa0;36.7-47.1%), mild cognitive impairment(MCI)(41.4%;95%C.I.&#xa0;=&#xa0;38.3-45.6%), anxiety(32.0%;95%C.I.&#xa0;=&#xa0;26.5-37.6%), MDD&#xa0;+&#xa0;anxiety(24.7%;95%C.I.&#xa0;=&#xa0;17.9-34.3%), and dementia(19.8%;95%C.I.&#xa0;=&#xa0;12.9-27.8%); in atrial fibrillation(AF): MCI(26.0%;95%C.I.&#xa0;=&#xa0;21.0-30.0%), anxiety in patients undergoing pulmonary vein isolation(PVI)(25.0%;95%C.I.&#xa0;=&#xa0;12.0-46.0%), MDD in PVI patients (20.0%;95%C.I.&#xa0;=&#xa0;13.0-29.0%); in coronary artery disease: MDD&#xa0;+&#xa0;anxiety(19.8%;95%C.I.&#xa0;=&#xa0;16.0-24.6%): in schizophrenia spectrum disorders: clozapine-associated-cardiomyopathy(0.6%;95%C.I.&#xa0;=&#xa0;0.2-2.3%); clozapine-associated-cardiomyopathy absolute death rates (0.0003;95%C.I.&#xa0;=&#xa0;0.0001-0.0012); clozapine-associated-cardiomyopathy case fatality rate (0.078;95%C.I.&#xa0;=&#xa0;0.018-0.285). Several additional disorders were multimorbid in>5% of people, yet with a lower credibility rating. No re-pooled risk factors/outcomes reached strong credibility criteria. CONCLUSIONS: The present study provides an atlas of cardiovascular and psychiatric multimorbidity across varying levels of credibility, reinforcing the need for an integrated, multidisciplinary approach to patient care and for more research on actionable risk/protective factors and outcomes.

Humans

Transverse Tibial Transport for Limb Salvage in Ischemic Lower Extremity Disease: Technique, Mechanisms, and Clinical Outcomes-A Systematic Review.

Transverse tibial transport (TTT) is a surgical technique derived from Ilizarov's distraction osteogenesis principles that stimulates angiogenesis and microcirculatory regeneration in the ischemic lower limb without directly manipulating macrovascular anatomy. By creating a proximal tibial cortical bone window and distracting it transversely using an external fixator, TTT triggers converging cascades of growth factor release, endothelial progenitor cell mobilization, and immunomodulation that translate into improved distal limb perfusion and wound healing. Combined TTT plus endovascular therapy improves amputation-free survival versus endovascular therapy alone. Prospective randomized trials and standardized international protocols are needed to consolidate TTT's role in multidisciplinary limb salvage pathways.

Humans

Clinical Performance of Bulk-Fill Versus Incremental Composite Placement Approaches in Vital Posterior Teeth: A 24&#x2009;Months Randomized Controlled Trial.

BACKGROUND: Composite resin placement technique may influence marginal integrity, polymerization stress distribution, and long-term clinical performance of posterior restorations. This randomized controlled clinical trial evaluated the 24-month clinical performance of four different placement techniques in Class I posterior composite restorations. METHODS: Fifty patients aged 20-35&#x2009;years presenting with four occlusal carious lesions each were enrolled, resulting in 200 restorations. Cavities (4-5&#x2009;mm depth) were prepared according to caries extension. Restorations were randomly allocated into four equal groups (n&#x2009;=&#x2009;50) according to placement technique: stamp technique, snowplow technique, modified incremental "pizza" technique, and bulk-fill technique. All materials were applied following manufacturers' instructions. Clinical evaluation was performed at baseline and after 6, 12, and 24&#x2009;months using FDI criteria. Functional (fracture/retention, marginal adaptation), esthetic (marginal staining, anatomical form), and biological (postoperative sensitivity, secondary caries) properties were assessed by two calibrated evaluators. Statistical analysis was performed at a significance level of &#x3b1;&#x2009;=&#x2009;0.05. RESULTS: Thirty-eight patients with a total of 152 restorations were evaluated at the end of the 24&#x2009;months in line with FDI at the end of the study with 76% recall rates. No statistically significant differences were observed among groups regarding fracture/retention or secondary caries (p&#x2009;>&#x2009;0.05). Marginal adaptation and marginal staining demonstrated minor deterioration over time across all groups, with statistically significant intergroup differences found (p&#x2009;<&#x2009;0.05). Postoperative sensitivity was minimal and transient in all groups with no significant difference (p&#x2009;=&#x2009;0.181). CONCLUSIONS: Within the limitations of this 24-month follow-up, the four placement techniques demonstrated comparable clinical performance in Class I posterior composite restorations. Selection of technique may therefore be guided by clinical preference and procedural efficiency rather than differences in short-term clinical outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07415317.

Humans

A modified stomal construction technique to reduce incidence of stomal stenosis in continent catheterizable channels.

BACKGROUND: Antegrade continence enema (ACE) and catheterizable bladder channel (Mitrofanoff) procedures are routinely performed in pediatric urology patients diagnosed with a neurogenic bladder and bowel. Stomal stenosis is a common surgical complication of these procedures, occurring in approximately 10-30% of stomas. Our frustration with this complication prompted us to modify our suturing technique during stomal construction to attempt to decrease the incidence of stomal stenosis. METHODS: We compared the rates of stomal stenosis between patients with neurogenic bladder who underwent the creation of an ACE or Mitrofanoff channel using the historical techniques (prior to April 2018) versus the current technique (from April 2018 to December 2020). Our current technique for stoma creation consists of suturing full thickness bowel to only the dermal layer of the skin using interrupted 5-0 polydioxanone interrupted sutures with the knots buried. Statistics were performed using Fisher's exact t-test, with p-values <0.05 considered significant. RESULTS: There were no significant differences in demographics between patients in the 2 cohorts. Stomal stenosis occurred in 25 of 98 stomas (25.5%) after undergoing either an ACE or Mitrofanoff procedure using the historical techniques, with a median patient follow-up of 122.6 months for ACE cohort and 165.8 for Mitrofanoff cohort. The incidence of stomal stenosis was significantly decreased in the current technique, with one of the 31 stomas (3.2%) experiencing stenosis (p = 0.022), with a median follow-up of 78.4 months for ACE cohort, and 66.5 months for Mitrofanoff cohort. These follow-up durations exceed the upper limits of time-to-stenosis in the historical stomas. Stomas in the current cohort have a minimum follow-up of 4.5 years and a maximum follow-up of 7 years. CONCLUSIONS: Our current suturing technique has significantly reduced the incidence of stomal stenosis in our patients. The technique is straightforward and flexible and can be applied to any stoma placed in any position. Only one of the patients with stomas created with the current suturing technique have developed stomal stenosis, with follow-up exceeding the median time to development of stenosis of our historical cohort.

Humans

Analysis of deep learning techniques in computer-aided diagnosis for meniscus injuries: a systematic literature review.

Meniscus informatics is a growing subject of study in the healthcare industry. One of the major hindrances to the healthcare system's transformation is obtaining knowledge and meaningful information from complicated, high-dimensional and diverse sources. Modern biomedical research, for instance, has seen an increase in the use of complex, dissimilar, poorly documented, and generally unstructured electronic health records, imaging, sensor data and text, even after many current techniques have been used to extract more robust and useful elements from the data for analysis. New efficient standards for building end-to-end learning models from complex data are therefore needed. Therefore, the current study aims to examine the most recent research on the use of deep learning techniques for diagnosing meniscus tears and recommend creating comprehensive and meaningful interpretable structures that might benefit the healthcare industry. We also draw attention to shortcomings and the need for better technique development, and we provide new perspectives about this exciting new development in the field.

Humans

An RPA-assisted homogeneous electrochemical DNA sensor for on-site eDNA detection toward early warning of crown-of-thorns starfish outbreaks.

Crown-of-thorns starfish (COTS) outbreaks seriously threaten coral reef ecosystems, while conventional monitoring approaches are time-consuming and often lack sufficient sensitivity for early warning. Existing electrochemical DNA sensors usually require complex electrode-surface immobilization procedures, which can lead to uneven probe distribution, significant steric hindrance, and poor stability. Meanwhile, the low concentration of environmental DNA (eDNA) in marine environments further complicates detection. To overcome these challenges, this study developed a homogeneous electrochemical DNA sensor assisted by recombinase polymerase amplification (RPA) for COTS eDNA detection. Target DNA was first amplified by RPA, and the amplification products were then hybridized in solution with capture probe (CP)-modified magnetic beads (MB) and biotin-labeled signal probe (SP) to form sandwich-structured MB complexes. These complexes were subsequently magnetically enriched and immobilized on the electrode surface for electrochemical signal readout. Under optimized conditions, the sensor displayed a linear response to COTS genomic DNA from 3.77&#xa0;fg/&#x3bc;L to 1&#xa0;ng/&#x3bc;L, with an LOD of 2.02&#xa0;fg/&#x3bc;L and an LOQ of 3.77&#xa0;fg/&#x3bc;L. The sensor was applied to Xisha Islands samples, and the results agreed with droplet digital PCR (ddPCR) (P&#xa0;>&#xa0;0.05), demonstrating its potential for sensitive and reliable on-site COTS eDNA detection.

Animals

Emerging techniques of CRISPR/Cas system in antiviral therapy and diagnostics: Applications, limitations, and translational perspectives.

The CRISPR/Cas (clustered regularly interspaced short palindromic repeats) system is a versatile technology for developing antiviral medicines and editing viral genomes in both diagnostics and vaccine synthesis. Emerging insights into class 2 effectors, such as Cas9, Cas12, and Cas13, which target viral DNA and RNA, have revolutionized vaccines against viruses such as HIV, HPV, HBV, and EBV. Innovative diagnostic techniques such as SHERLOCK, DETECTR, and FELUDA have demonstrated system's diversity and accuracy in detecting the virus markers, supporting clinical decision-making, indicating adaptability and precision of CRISPR. This review critically evaluates CRISPR's role in RNA editing, emphasizing its importance for functional genomics and development of recombinant vaccines. Translational challenges are critically discussed, including off-target effects, delivery limitations, and ethical issues, for which unique approaches such as high-fidelity Cas variants, non-viral delivery systems, and bioethical frameworks are evaluated to address these limitations. This review also covers other social implications, such as accessibility and biosecurity risks, associated with CRISPR technologies Collectively, these advances underscore the transformative potential of CRISPR technologies in shaping next-generation antiviral diagnostics and therapeutics.

CRISPR-Cas Systems