Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Methacrylates”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Mechanical properties of hydrophilic copolymers of 2-hydroxyethyl methacrylate with ethyl acrylate, n-butyl acrylate, and dodecyl methacrylate.

Copolymers were prepared of 2-hydroxyethyl methacrylate, which is strongly hydrophilic, with hydrophobic comonomers having a low glass transition temperature, i.e., ethyl acrylate, n-butyl acrylate, and dodecyl methacrylate. The glass transition temperature, T alpha (1 Hz), of polymers in the dry state (xerogels) was determined by means of dynamic mechanical measurements. The dependence of T alpha on composition in all the three series of copolymers was described in terms of a one-parameter equation. The equilibrium swelling of copolymers in water decreases more steeply than the weight fraction of 2-hydroxyethyl methacrylate. When swollen in water to equilibrium, all copolymers with ethyl acrylate or n-butyl acrylate are in the rubberlike state; their tensile modulus E assumes values in the range 0.17-0.50 MPa. While poly(2-hydroxyethyl methacrylate) has the modulus E = 0.39 MPa, the tensile strength sigma u = 0.32 MPa, and the strain-at-break epsilon u = 1.81, for the weight fraction of the comonomer in the range 0.36 less than or equal to omega 2 less than or equal to 0.56 it is possible to achieve sigma u and epsilon u lying in the respective ranges 0.7-0.9 MPa and 5-7. Copolymers with the dodecyl methacrylate content omega 2 less than 0.2 or omega 2 greater than 0.8 are rubberlike, and at 0.30 less than or equal to omega 2 less than or equal to 0.62 they become leathery; the latter have the modulus E and strength sigma u within the ranges 12-32 and 3-4 MPa, respectively. The stress-strain curves of these copolymers evidence yielding and orientation hardening which have been tentatively explained by the nonhomogeneous composition and structure of the copolymers.

Acrylates↗

pH-dependent swelling and solute diffusion characteristics of poly(hydroxyethyl methacrylate-co-methacrylic acid) hydrogels.

Poly(hydroxyethyl methacrylate-co-methacrylic acid) hydrogels can swell extensively in a high-pH medium where the carboxyl groups are ionized. The swelling equilibrium is a strong function of the methacrylic acid composition of the polymer and pH of the medium. The nonionized gel structure was found to be rather insensitive to the amount of cross-linker, tetraethylene glycol dimethacrylate (TEGDMA), incorporated, within the range of 0.5 to 3%. This result is supportive of the existence of secondary interactions that shield the effect of covalent cross-links. Phenylpropanolamine (PPA) was used as a probe solute to study the diffusion characteristics of the poly(HEMA-co-MA) gels. Its diffusion coefficient in the swollen matrices of different methacrylic acid compositions at various pH's was measured via a desorption method. It is evident that these diffusion coefficients follow Yasuda's free volume theory, which expresses an exponential relationship between the solute diffusivity in a swollen polymer membrane and the reciprocal of the membrane hydration. Although interactions exist between PPA and the hydrogel matrix, these interactions are not significant enough to perturb the free volume relationship established. This observation can be explained by the high ionic strength of the system.

Acrylates↗

Binding mechanisms of methacrylic acid and methyl methacrylate on si(111)-7 x 7 -- effect of substitution groups.

The interaction of methacrylic acid and methyl methacrylate with Si(111)-7 x 7 has been investigated using high-resolution electron energy loss spectroscopy (HREELS) and X-ray photoelectron spectroscopy (XPS). While methacrylic acid chemisorbs dissociatively through O-H bond cleavage, methyl methacrylate is covalently attached to the silicon surface via a [4+2] cycloaddition. The different reaction pathways of these two compounds on Si(111)-7 x 7 demonstrate that the substitution groups play an important role in determining the reaction channels for multifunctional molecules, leading to the desired flexibility in the organic modification of silicon surfaces.

Boron↗

On permeability of methyl methacrylate, 2-hydroxyethyl methacrylate and triethyleneglycol dimethacrylate through protective gloves in dentistry.

Continuous glove use is more common in dentistry than in most other occupations, and the glove should offer protection against blood-borne infections, skin irritants and contact allergens. Methacrylate monomers are potent contact allergens, and it is known that these substances may penetrate the glove materials commonly used. The aim of this study was to assess the permeability of various types of gloves to methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (HEMA) and triethyleneglycol dimethacrylate (TEGDMA) with special reference to combinations with ethanol or acetone. The permeation rate and time lag breakthrough (lag-BT) for MMA (neat, or diluted to 30% in ethanol or acetone), HEMA (30% in water, ethanol, or acetone) and TEGDMA (30% in ethanol or acetone) were investigated for different protective gloves. Nine different types of gloves were tested for one or several of these methacrylates. The lag-BT for neat MMA was </= 2 min for all gloves. For 30% MMA in ethanol or acetone, the latex gloves and the polyethene-copolymer glove showed the best protection, but the lag-BTs were short for all gloves. For HEMA and TEGDMA, the lag-BTs were generally longer than for MMA. A neoprene glove seemed to be the best choice for protection against penetration of HEMA and TEGDMA. The decision on which types of gloves to use should also take into account the risks of latex allergy and contact allergy to rubber chemicals and the convenience of the gloves for fine manual work.

Acetone↗

Floating on a water bath and mounting glycol methacrylate and hydroxypropyl methacrylate sections influence final dimensions.

This paper reports the dimensional changes occurring in the different steps of the histoprocessing of tissues for light microscopy. Two water-miscible methacrylates used for embedding, namely 2-hydroxyethyl methacrylate and 2-hydroxypropyl methacrylate, were investigated. It was found that during stretching on the water bath and in the mounting step considerable size changes occur, which are of the same magnitude as during the dehydration step of histoprocessing. The final dimensions of the sections and of microscopic images are dependent on the response to surface tension at the water surface and mounting of the glycol and hydroxypropyl methacrylate sections, respectively. Between the two resins under study, significant differences in the size of the resin sections, with and without embedded liver tissue, were found. It is shown that the temperature at which the sections are mounted is of great importance. These observations indicate the importance of standardizing histotechniques if morphometry is to be applied.

Acrylates↗

Toxicology of methyl methacrylate: the rate of disappearance of methyl methacrylate in human blood in vitro.

1. The rate of disappearance of methyl methacrylate in blood has been determined using an isotope dilution technique. 2. At a concentration of 10(-4) mol dm(-3), methyl methacrylate disappears with pseudo first order kinetics. 3. The half-life of methyl methacrylate in blood at 37 degrees C lies in the range 20--40 min. 4. The half-life showed no dependence on the age or sex of the blood donor. 5. A major, possibly the only, pathway of metabolism is by hydrolysis to methacrylic acid.

Adult↗

Synthesis and properties of amphiphilic networks 3: preparation and characterization of block conetworks of poly(butyl methacrylate-block-(2,3 propandiol-1-methacrylate-stat-ethandiol dimethacrylate)).

Amphiphilic conetwork polymers were prepared and studied as substrates in the culture of dermal fibroblasts. Both block and random conetworks polymers were produced by radical polymerization of either low-molecular weight monomers or oligomeric macromonomers. The oligomeric macromonomers were prepared by methacrylation of biscarboxy oligo(butyl methacrylates) (OBMA). The latter were synthesized by ozononolysis of poly(butyl methacrylate-co-butadiene) materials. The hydrophilic component was derived from copolymerization with 2,3 propandiol-1-methacrylate and cross-linking was provided by inclusion of ethandiol dimethacrylate (EDMA). None of the synthesized materials showed indications of cytotoxicity to human dermal fibroblasts. All of the block conetworks were highly phase separated and possessed pores on the micron length scale. The equilibrium water contents of the latter could be controlled by addition of EDMA. Block conetworks that did not contain EDMA were highly swollen and had smoother surfaces than those that contained EDMA. The former were poor substrates for cell proliferation (as measured by monitoring DNA content) whilst the latter class gave increasing levels of DNA during culture; an indicator proliferation. The performance of these materials in cell culture was also dependent on the fraction of OBMA in the formulation. Increasing the fractions of BMA, either in the random terpolymer or block networks, system had the effect of increasing both cell proliferation and viability (as measured by the Alamar Blue assay).

Biocompatible Materials↗

Evaluation of biocompatibility of the copolymer of 2-hydroxyethyl methacrylate with 2-(methylsulfanyl)ethyl methacrylate.

This study compares subcutaneous and intracerebral biocompatibilty of two hydrogels: copolymer of 2-hydroxyethyl methacrylate with 2-(methylsulfanyl)ethyl methacrylate and poly(2-hydroxyethyl methacrylate) as reference polymer. The experimental copolymer was more biologically inert than poly(2-hydroxyethyl methacrylate) in both the studied parameters, hence the former material is a suitable candidate for biomedical application.

Journal Article↗

A nonaqueous potentiometric titration study of the dissociation of t-butyl methacrylate-methacrylic acid copolymers.

The dissociation of t-butyl methacrylate-methacrylic acid copolymers in dimethyl sulfoxide was analyzed by a nonaqueous potentiometric titration technique. The negative logarithm of the dissociation constant of the monomer unit of a methacrylic acid (MAA) monotonously increased with the increasing degree of dissociation corresponding to the titrant/MAA amount ratio, and was highly influenced by the copolymerization ratio. The results are discussed in terms of the suppression of the dissociation of MAA by a neighboring charged methacrylate anion unit.

Journal Article↗

The electrochemical behaviour of ferrocene in a photocurable poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) film for a glucose biosensor.

A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.

Biosensing Techniques↗

Culture of dermal fibroblasts and protein adsorption on block conetworks of poly(butyl methacrylate-block-(2,3 propandiol-1-methacrylate-stat-ethandiol dimethacrylate)).

Amphiphilic block terpolymer conetworks composed of butyl methacrylate (BMA), 2,3 propandiol-1-methacrylate (GMMA) and ethandiol dimethacrylate (EDMA) were synthesized. Telechelic oligomers with the carboxylic acid end groups were made via ozonolysis of poly(BMA-co-butadiene) and then these were reacted with glycidyl methacrylate to obtain cross-linkable vinyl groups at both chain ends. Networks were then formed via free radical copolymerization with EDMA and GMMA or 2-methyl-acrylic acid 2,2-dimethyl-[1,3]dioxolan-4-ylmethyl ester (GMAc). The acetonide groups of the GMAc units were then removed, by reaction with selenium dioxide and hydrogen peroxide, to give networks with the same molecular structure as the GMMA terpolymers but different cell adhesion and protein adsorption properties. Protein adsorption was maximised in networks prepared with GMMA rather than with GMAc followed by removal of the acetonide. Block conetworks that were synthesised with GMAc were poor substrates for cell proliferation whilst the GMMA class support good levels of both cell viability and proliferation. It is suggested that the difference in behaviour is derived from changes in the surface composition.

Apoptosis↗

Affinity chromatography of proteins on non-porous copolymerized particles of styrene, methyl methacrylate and glycidyl methacrylate.

Non-porous particles having an average diameter of 2.1 microm were prepared by co-polymerization of styrene, methyl methacrylate and glycidyl methacrylate, which was abbreviated as P(S-MMA-GMA). The particles were mechanically stable due to the presence of benzene rings in the backbone of polymer chains, and could withstand high pressures when a column packed with these particles was operated in the HPLC mode. The polymer particles were advantaged by immobilization of ligands via the epoxy groups on the particle surface that were introduced by one of the monomers, glycidyl methacrylate. As a model system, Cibacron Blue 3G-A was covalently immobilized onto the non-porous copolymer beads. The dye-immobilized P(S-MMA-GMA) particles were slurry packed into a 1.0 cm x 0.46 cm I.D. column. This affinity column was effective for the separation of turkey egg white lysozyme from a protein mixture. The bound lysozyme could be eluted to yield a sharp peak by using a phosphate buffer containing 1 M NaCl. For a sample containing up to 8 microg of lysozyme, the retained portion of proteins could be completely eluted without any slit peak. Due to the use of a shorter column, the analysis time was shorter in comparison with other affinity systems reported in the literature. The retention time could be reduced significantly by increasing the flow-rate, while the capacity factor remained at the same level.

Chromatography, Affinity↗

Structure-activity relationships in allergic contact dermatitis induced by methacrylates. Studies of the influence of side-chain length of methacrylates.

Some methacrylates are known to be strong contact sensitizers. To determine the effect of side-chain length on sensitizing potential, we examined 11 derivatives with linear side chains from C1 to C18 in an experimental sensitization test in guinea pigs. The results showed an increase in the sensitizing potential with increasing length of the alkyl side chain from C1 to C12. The C12 derivative, lauryl methacrylate, showed the strongest sensitizing potential. Further elongation of the alkyl side chain of methacrylates resulted in a decrease in the potential. With respect to the side-chain-length-dependent sensitizing potential, the present results correspond well with the findings obtained with other compounds like primin, catechols, phenols, hydroquinones, and gallates.

Administration, Topical↗

A simple procedure for extracting methacrylic acid from water-miscible methacrylates.

A simple procedure for removing methacrylic acid from water-miscible methacrylates is described. One volume of monomer is diluted with 9 volumes of diethyl ether. Three consecutive extractions are carried out with 5% aqueous NaHCO3 at 4 C. Residual water is removed by shaking with anhydrous sodium sulfate. The ether is removed by flash evaporation on a Büchi Rotavapor. Weak alkali extraction produces good quality semithin sections which are free of background staining. This method may be a useful alternative to existing methods for removal of methacrylic acid.

Acrylates↗

Glycol methacrylate embedding in histotechnology: the hematoxylin-eosin stain as a method for assessing the stability of glycol methacrylate sections.

Glycol methacrylate (GMA) samples containing inhibitor in the range of 200-300 ppm were included in a standard embedding mixture. The pH of the GMA samples was measured as a 10% solution of the sample in distilled water. The acidity of GMA due to methacrylic acid causes background staining of sections after basic dyes. The concentration of GMA and the amount of impurities such as methacrylic acid (MA) and ethylene glycol dimethacrylate (EDMA) were measured by gas chromatography. Distinct variations in purity were found among five samples of GMA. Sections derived from GMA samples containing more than 2% EDMA showed few, if any, minifolds after staining with hematoxylin and eosin and were more stable in alcoholic and basic solutions; sections from purer GMA showed minifolds and were less stable. Addition of crosslinkers, EDMA or triethylene glycol dimethacrylate (TEDMA) prevented these artifacts. Crosslinkers clearly influence dimensional changes in sections. Addition of crosslinkers to GMA samples containing minimal amounts of MA improved the results. The possibility of obtaining a high quality GMA embedding medium is discussed.

Acrylates↗

Biological properties of copolymer of 2-hydroxyethyl methacrylate with sulfopropyl methacrylate.

Interaction of organism with non-toxic implanted polymers depends on the physicochemical properties of the implant surface, which influence the adsorption of bioactive proteins and subsequently adhesion and growth of cells. The synthetic hydrogels are known as poorly adhesive surfaces. In this study we demonstrated the adsorption of albumin, fibrinogen, fibronectin, basic fibroblast growth factor, heparin-binding epidermal growth factor-like growth factor and epidermal growth factor to poly(2-hydroxyethyl methacrylate) (pHEMA) and copolymer of 2-hydroxyethyl methacrylate (HEMA) and potassium salt of 3-sulfopropyl methacrylate (SPMAK). The adhesion and growth of 3T3 cells and human keratinocytes on surface of these polymers was tested without and with pretreatment of polymers with heparin-binding epidermal growth factor-like growth factor. The adhesion of mixture of human granulocytes and monocytes to these surfaces was also tested. The strips of both polymers were subcutaneously and intracerebrally implanted into the rat and the extent of foreign body reaction and brain biocompatibility was evaluated. The results showed the extensive adsorption of basic fibroblast growth factor and heparin-binding epidermal growth factor-like growth factor to copolymer containing SPMAK. However the adhesion (and growth) of cells to this type of copolymers was very low. Preadsorption of human plasma to pHEMA clearly stimulated the leukocyte adhesion in contrary to copolymer containing SPMAK. The extent of foreign-body reaction was significantly higher against the pHEMA compared to tested copolymer p(HEMA-co-SPMAK). In conclusion, the tested copolymer was a poorly adhesive substrate that is only poorly recognized by the non-specific immunity, although the adsorption of basic growth factors to this substrate is highly significant. Both polymers were well tolerated by the brain tissue. The phenotype of surrounding neurons was more close to the control neurons in the brain tissue surrounding the p(HEMA-co-SPMAK) implants.

Journal Article↗

Long-term in vivo biomechanical properties and biocompatibility of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) nerve conduits.

Artificial grafts are promising alternatives to nerve grafts for peripheral nerve repair because they obviate the complications and disadvantages associated with autografting such as donor site morbidity and limited tissue availability. We have synthesized poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA) porous tubes and studied their efficacy in vivo. Specifically, we studied the short- and long-term stability and biocompatibility of 12 mm long tubes for the repair of surgically created 10 mm nerve gaps in rat sciatic nerves. Prior to implantation, tubes were analyzed in vitro using a micro-mechanical tester to measure displacement achieved with load applied. These results served as a calibration curve, y = 6.8105 x -0.0073 (R2 = 0.9750, n = 28), for in vivo morphometric tube compression measurements. In vivo, most of the PHEMA-MMA conduits maintained their structural integrity up to 8 weeks, but 29% (4/14) of them collapsed by 16 weeks. Interestingly, the tube wall area of collapsed 16-week tubes was significantly lower than those of patent tubes. Tubes were largely biocompatible; however, a small subset of 16-week tubes displayed signs of chronic inflammation characterized by "finger-like" tissue extensions invading the inner tube aspect, inflammatory cells (some of which were ED1+macrophages) and giant cells. Tubes also demonstrated signs of calcification, which increased from 8 to 16 weeks. To overcome these issues, future nerve conduits will be re-designed to be more robust and biocompatible.

Animals↗