Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Laryngoscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

The combination of a fiberoptic stylet and a McCoy laryngoscope facilitates tracheal intubation in difficult airway cases.

PURPOSE: Fiberoptic stylets are considered useful for difficult airway management. In the present study, we assessed the usefulness of a fiberoptic stylet when the stylet was used with a Macintosh or a McCoy laryngoscope. METHODS: Twenty-four patients, whose airways were graded as Cormack grade III, were studied. We compared the times required for tracheal intubation when the fiberoptic stylet was used with a Macintosh direct laryngoscope and when it was used with a McCoy laryngoscope. Cormack grade III was subdivided into IIIa (with distance between the epiglottis and the posterior wall of the pharynx) and IIIb (with no distance between the epiglottis and the posterior wall of the pharynx), according to the view of the vocal cords by the laryngoscope. RESULTS: The intubation time in grade IIIb patients, who were intubated by the concurrent use of the fiberoptic stylet and the McCoy laryngoscope (28 +/- 4 s), was not significantly different from that in grade IIIa patients (28 +/- 10 s). The intubation time in grade IIIb patients, who were intubated by the concurrent use of the fiberoptic stylet and the Macintosh laryngoscope (52 +/- 8 s), was significantly longer than that in grades IIIa (28 +/- 10 s; P < 0.01) or IIIb with the McCoy laryngoscope (28 +/- 4 s; P < 0.01). CONCLUSION: The combination of a new handy fiberoptic stylet and a McCoy laryngoscope facilitated tracheal intubation of patients whose airway had no distance between the epiglottis and the posterior wall of the pharynx in laryngoscopic vocal cord view.

Journal Article↗

The McCoy levering laryngoscope in patients with limited neck extension.

PURPOSE: The McCoy levering laryngoscope is a modified Macintosh laryngoscope, which has a hinged tip controlled by a lever on the handle. The purpose of this study was to investigate whether the tip elevation of this laryngoscope results in better laryngeal visualization than using the Macintosh laryngoscope when the patient's neck is fixed in the neutral position. METHODS: Fifty female patients (ASA physical status I-II) undergoing elective surgery during general anaesthesia were investigated. The patient's neck was manually fixed in the neutral position by an assistant, and laryngeal visualization was attempted first with a size #3 Macintosh laryngoscope (Macintosh trial), and then with a size #3 McCoy levering laryngoscope with blade tip elevation (McCoy trial), and tracheal intubation was attempted. Trials of laryngeal visualization were evaluated with the Cormack score. RESULTS: In the Macintosh trial, 36 of 50 (72%) patients were evaluated grade 3, and two grade 4. In most of the patients graded 2 and 3 in the Macintosh trial (70% of the grade 2 and 83% of the grade 3 cases), the laryngeal view was improved by using the McCoy levering laryngoscope. The Cormack grade in the McCoy trial was less than that in the Macintosh trial (P < 0.01). No complications were observed during the study. CONCLUSION: The McCoy levering laryngoscope improved laryngeal visualization in patients whose neck cannot be extended.

Female↗

Lower flange modification improves performance of the Macintosh, but not the Miller laryngoscope blade.

PURPOSE: In order to minimize the potential for dental damage and to improve laryngeal visualization during tracheal intubation, two commonly used laryngoscope blades were modified and compared in a clinical setting: the Miller laryngoscope blade and the Macintosh laryngoscope blade. Modified versions of both laryngoscope blades with a lowered heel (Callander modification) at the proximal end of the blade were compared to standard blades. METHODS: Forty patients scheduled for general anesthesia requiring endotracheal intubation were studied prospectively. Preoperatively, the patients' airways were evaluated according to Mallampati score, thyromental distance and interincisor gap. After induction of anesthesia laryngoscopy was performed with the original laryngoscope and its modified counterpart in random order. A lateral x-ray of the neck was taken after the optimal view had been obtained, and blade-tooth distance, laryngeal view, blade-tooth contact and need for assistance were measured. Using angular calculations the laryngoscopes were analyzed at different insertion depths on graph paper, and the results were compared with data from the lateral x-rays. RESULTS: With a modified Macintosh blade the blade-tooth distance was significantly greater in comparison to the original design (2.5 +/- 2.1 cm vs 0.2 +/- 0.1 cm, P < 0.01). Consequently the number of blade-tooth contacts was significantly lower (20% vs 75%, P < 0.05). The best laryngeal view could be obtained using a modified Macintosh laryngoscope. With a modified Miller laryngoscope laryngeal visibility was not improved and assistance was required more often to achieve adequate intubating conditions (35% vs 5%, P < 0.05). CONCLUSION: A reduction of the proximal flange of a Miller blade decreases the blade's effectiveness for laryngeal visualization, whereas a similar modification of a Macintosh blade increases blade-tooth distance, decreases the number of blade-tooth contacts and provides a better laryngeal view.

Adult↗

Analysis of the forces and position required for direct laryngoscopic exposure of the anterior vocal folds.

The sniffing position is traditionally considered optimal for direct laryngoscopic examination of the vocal folds. This study examined head and neck positions associated with ideal exposure of the anterior glottal commissure with a variety of laryngoscopes. A prospective investigation was done in 20 patients by comparing the force required to expose the anterior vocal folds by utilizing 3 head and neck positions with 3 different-sized tubular laryngoscopes. The completeness of anterior glottal exposure was rated and the force required to achieve this exposure was measured with a strain gauge. Three positions relating the atlanto-occipital and cervicothoracic vertebrae were analyzed: 1) extension-extension. 2) sniffing: extension-flexion, and 3) flexion-flexion. Head and neck position and laryngoscope size were both statistically significant factors for achieving complete anterior vocal fold exposure. Regardless of the laryngoscope, the number of patients in whom complete exposure could be achieved increased gradually when the position was changed from extension-extension to extension-flexion to flexion-flexion. Complete exposure was inversely related to larger laryngoscope size. According to the data herein, the flexion-flexion position provides the best glottal exposure for endotracheal intubation in those patients who are anatomically predisposed to difficulty in direct examination of the glottis. Because this places the laryngoscope lumen in a vertical position, this position is inappropriate for microlaryngoscopy. The study reinforced the concept that the sniffing position is the optimal position for microlaryngoscopy because it enables the use of the largest-lumened laryngoscope. This facilitates ideal exposure of the anterior vocal folds, which is necessary for phonomicrosurgery.

Equipment Design↗

["Tube scratching" in the trachea on nasotracheal intubation: comparison of Macintosh and McCoy laryngoscopes].

BACKGROUND: "Tube scratching" in the trachea, the intratracheal resistance of a tube, on nasotracheal intubation was evaluated using the Macintosh and the McCoy laryngoscope blade. METHODS: Fifty young patients requiring nasotracheal intubation were studied. Following induction of anesthesia, X-ray was taken before and during the use of two types of laryngoscopes. For analysis of the configuration of the upper airway, we drew three straight lines [axis of pharynx (P), larynx (L) and trachea (T)] on each film. "Tube scratching" was evaluated and graded to four by a supporting anesthesiologists. RESULTS: "Tube scratching" in the trachea was observed in 14/25 patients with McCoy laryngoscope and 4/25 patients with Macintosh laryngoscope (P < 0.05). Intubation with McCoy laryngoscope decreased more the angles formed by P and L, and L and P those that with Macintosh laryngoscope (P < 0.01). These data indicate that the lines of P, L and T tend not to align with McCoy laryngoscope, preventing the tracheal tube to be passed smoothly. CONCLUSION: An excessive lifting of the epiglottis, often observed in using McCoy laryngoscope, causes "Tube scratching" in the trachea on nasotracheal intubation.

Adult↗

Less Invasive Surfactant Administration Using Video Laryngoscope to Decrease Pain in Neonates: A Randomized Controlled Trial.

OBJECTIVES: To assess whether the use of video laryngoscope, when compared to conventional laryngoscope decreases pain (assessed by Faceless Acute Neonatal Pain Scale) in preterm neonates while administering surfactant by LISA. METHODS: Preterm neonates <&#x2009;35 weeks requiring FiO2&#x2009;>&#x2009;0.3 on CPAP pressure of at least 6&#x2009;cm of H2O were administered surfactant by LISA technique either by video laryngoscope (Intervention) or conventional laryngoscope (Control). Faceless Acute Neonatal Pain Scale was used to determine pain 5&#x2009;min before the procedure, immediately, 5&#x2009;min, and 10&#x2009;min after the procedure. The primary outcome was severity of pain; secondary outcomes were time taken to complete the procedure, number of attempts, incidence of IVH, and adverse events during the procedure. RESULTS: In total, 42 neonates of <&#x2009;35 weeks gestation with comparable baseline demographics were randomized into 2 groups. The median (IQR) FANS score immediately post-procedure in the intervention arm was 2 (2-4) versus 2 (1-4) in the control arm, p&#x2009;=&#x2009;0.79. There was no statistical difference in the secondary outcomes studied. CONCLUSION: The two groups had no difference in the pain score. The pain experienced by neonates during the LISA procedure was moderate and of short duration and it did not depend on the type of laryngoscope used. Moderate pain during the procedure can be managed with nonpharmacological measures; thereby, the use of sedatives or analgesics can be avoided, which might be of concern. There was no difference in the number of attempts or in time taken to complete the procedure when performed by neonatologists experienced in using conventional laryngoscopes compared to video laryngoscopes. TRIAL REGISTRATION: Clinical Trial Registry of India: CTRI/2022/09/045204 on 05.09.2022.

Humans↗

Quantitative improvement in laryngoscopic view by optimal external laryngeal manipulation.

STUDY OBJECTIVE: To determine the improvement in laryngoscopic view obtained using both the Macintosh and Miller blades by applying optimal external laryngeal manipulation (OELM). DESIGN: Prospective, with each patient serving as his or her own control. SETTING: Inpatient operating rooms of a University Medical Center. PATIENTS: 181 informed and consenting adult nonpregnant patients requiring general anesthesia and tracheal intubation. The only exclusion criteria was the need to apply cricoid pressure to prevent aspiration of gastric contents. INTERVENTIONS: Anesthetized, paralyzed patients underwent laryngoscopy without external laryngeal manipulation and the laryngoscopic view was graded ("A") according to visualized structures [1.0-1.9 = all (1.0) or part of the vocal cords (90% = 1.1 and 10% = 1.9); 2 = just the arytenoids; 3 = just the epiglottis; 4 = just the soft palate]. The larynx was then quickly manipulated by the thumb and index and middle fingers of the laryngoscopist's right hand in both cephalad and posterior directions over the hyoid, thyroid, and cricoid cartilages until it was determined which vector and spot produced the optimal laryngoscopic view ("B"). MEASUREMENTS AND MAIN RESULTS: It was found that in every patient with a "A" greater than 1.0, OELM improved the view; i.e., "B" decreased relative to "A." For both the Macintosh blade patients and Miller blade patients with an "A" equal to 2, "B" decreased by one whole laryngoscopic grade in all patients. For both the Macintosh and Miller blade patients with an "A" equal to 3, "B" decreased by at least one whole laryngoscopic grade in all patients and by two laryngoscopic grades in most patients. No patient had an "A" equal to 4. The distribution of optimal-external-laryngeal-manipulation (OELM) spots for all patients was 1%, 40%, 48%, and 11% for the hyoid, high thyroid, low thyroid, and cricoid cartilages, respectively, and the distribution was not significantly different for either the Macintosh and Miller blade groups or for the "A" and "B" subgroups (i.e., "A" < 1.9, = 2 or = 3). CONCLUSIONS: We conclude that OELM can improve the laryngoscopic view by at least one whole grade, that the best way to determine OELM for an individual patient is on an empirical basis by manipulation of the larynx with the laryngoscopist's right hand, and that OELM should be an instinctive and reflex response to any "A" of 2, 3, or 4.

Adolescent↗

[Intratracheal intubation using a fiberoptic laryngoscope].

Experience with a new type of laryngoscope (Bullard) is reported. It weighs 1,200 kg, and has fiberoptic fibers both for lighting and viewing. Angle of vision is about 55 degrees. Endotracheal intubation with this device requires a semi-rigid stylet to bend the tracheal tube at 90 degrees just above its cuff, so as to reproduce the curvature of the laryngoscope blade. Intubation is carried out in five steps: 1) introducing the laryngoscope blade, and visualising the vocal cords through its lens; 2) introducing the tube with its stylet, just above the laryngoscope blade; 3) placing the tube between the vocal cords under fiberoptic vision; 4) adjusting tube position in the trachea, the stylet still in place; 5) removing both stylet and laryngoscope. The use of this apparatus in an obese patient with reduced mobility of the cervical spine, who was ranked 4 on the Mallampati scale, is reported. The Bullard laryngoscope enabled easy tracheal intubation (duration 1 min 30 s), whereas direct laryngoscopy and the use of a Huffman prism were unsuccessful. The fiberoptic laryngoscope may be of help in case of difficult intubation.

Female↗

A new mirrored laryngoscope.

A new laryngoscope has been designed, incorporating an adjustable mirror and a levered tip similar to the McCoy blade, in an attempt to bridge the gulf between simple direct laryngoscopy and fiberoptic laryngoscopy. Manual in-line neck stabilisation was used to simulate difficult laryngoscopy in 14 anaesthetised patients after full neuromuscular blockade. The best view at laryngoscopy was assessed using a standard Macintosh laryngsocope, a size 3 McCoy laryngoscope and the mirrored laryngoscope. The best laryngeal view obtained in all cases with the Macintosh blade was a grade 3. The mirrored laryngoscope improved this view in 10 cases (71%) compared with five cases (36%) with the McCoy laryngoscope (p = 0.005); in seven cases (50%), the view improved to a grade 1 compared with no cases when the McCoy was used (p = 0.02). We conclude that the mirrored laryngoscope offers considerable advantages over the Macintosh and the McCoy laryngoscopes in simulated difficult laryngoscopy, is simple to use and requires no special training.

Anesthesia, General↗

Hemodynamic responses to tracheal intubation with laryngoscope versus lightwand intubating device (Trachlight) in adults with normal airway.

UNLABELLED: Lightwand devices are effective and safe as an aid to tracheal intubation. Theoretically, avoiding direct-vision laryngoscopy could allow for less stimulation by intubation than the conventional laryngoscopic procedure. We designed this prospective randomized study to assess the cardiovascular changes after either lightwand or direct laryngoscopic tracheal intubation in adult patients anesthetized with sevoflurane. Sixty healthy adult patients with normal airways were randomly assigned to one of three groups according to intubating procedure under sevoflurane/nitrous oxide anesthesia (fraction of inspired oxygen = 0.33) (n = 20 each). The lightwand group received tracheal intubation with Trachlight, the laryngoscope-intubation group received tracheal intubation with a direct-vision laryngoscope (Macintosh blade), and the laryngoscopy-alone group received the laryngoscope alone. Heart rate and systolic blood pressure were recorded continuously for 5 min after tracheal intubation or laryngoscopy with enough time to intubate. All procedures were successful on the first attempt. The maximum heart rate and systolic blood pressure values obtained after intubation with Trachlight (114 +/- 20 bpm and 143 +/- 30 mm Hg, respectively) did not differ from those with the Macintosh laryngoscope (114 +/- 20 bpm and 138 +/- 23 mm Hg), but they were significantly larger than those in the laryngoscopy-alone group (94 +/- 19 bpm and 112 +/- 21 mm Hg) (P < 0.05). Direct stimulation of the trachea appears to be a major cause of the hemodynamic changes associated with tracheal intubation. IMPLICATIONS: The magnitude of hemodynamic changes associated with tracheal intubation with the Trachlight is almost the same as that which occurs with the direct laryngoscope. Hemodynamic changes are likely to occur because of direct tracheal irritation rather than direct stimulation of the larynx.

Adult↗

Teaching with a video system improves the training period but not subsequent success of tracheal intubation with the Bullard laryngoscope.

BACKGROUND: The Bullard laryngoscope is useful for the management of a variety of airway management scenarios. Without the aid of a video system, teaching laryngoscopy skills occurs with indirect feedback to the instructor. The purpose of this study was to determine if use of a video system would speed the process of learning the Bullard laryngoscope or improve the performance (speed or success) of its use. METHODS: Thirty-six anesthesia providers with no previous Bullard laryngoscope experience were randomly divided into two groups: initial training (first 15 intubations) with looking directly through the eyepiece (n = 20), or with the display of the scope on a video monitor (n = 16). The subjects each then performed 15 Bullard intubations by looking directly through the eyepiece. RESULTS: There was not an overall significant difference in laryngoscopy or intubation times between the groups. When only the first 15 intubations were considered, the laryngoscopy time was shorter in the video group (26 +/- 24) than in the nonvideo group (32 +/- 34; P< 0.04). In the first 15 patients, there were fewer single attempts at intubation (67.9% vs 80.3%; P< 0.002) and more failed intubations (17.2% vs 6.0%; P< 0.0001) in the nonvideo group. CONCLUSIONS: In conclusion, the authors have shown that use of a video camera decreases time for laryngoscopic view and improves success rate when the Bullard laryngoscope is first being taught to experienced clinicians. However, these benefits are not evident as more experience with the Bullard laryngoscope is achieved, such that no difference in skill with the Bullard laryngoscope is discernible after 15 intubations whether a video system was used to teach this technique.

Female↗

Laryngoscope handles: a potential for infection.

Laryngoscope handles do not usually come in direct contact with the patient's mucous membranes. Consequently, routine disinfection of laryngoscope handles is not currently standard practice unless gross contamination is clearly evident. Recent reports indicate that apparently clean handles may be contaminated with blood or body fluids. No report examined microbes on handles. The present article describes the incidence and types of microbes on laryngoscope handles after their use in the operating rooms of a 502-bed medical center in northwestern Pennsylvania. Twenty laryngoscope handles were cultured on Mueller Hinton 5% sheep blood agar plates. The plates were incubated at 37 degrees C for 48 hours and examined for growth. The identification, incidence, and susceptibility patterns of organisms were determined. Microorganisms were present on all 20 laryngoscope handles. Nine different types were isolated; some strains were resistant to multiple antibiotics. Organisms were categorized as contaminants or opportunistic pathogens. The presence of opportunistic pathogens places anesthesia providers and patients at risk of nosocomial infections. Based on the recommendations of the 1997 American Association of Nurse Anesthetists' Infection Control Guide and the results of the present study, institutional guidelines should be established for the use of disposable laryngoscope covers, high-level (destroying all microorganisms with the exception of high numbers of bacterial spores) disinfection, or sterilization of laryngoscope equipment between each patient use.

Cross Infection↗

[A new device for difficult intubation--the MacCoy Laryngoscope].

The author introduces a new laryngoscope 'MacCoy Laryngoscope' and report its characteristics. The design of this laryngoscope is based on the standard Macintosh blade and it is attached to a standard handle. The characteristics of this laryngoscope are the hinged blade tip, which is controlled by a lever attached to the blade. The elevation of the blade tip makes it easy to visualise the larynx while the overall laryngoscopic movement decreases. Therefore this laryngoscope reduces the force employed during laryngoscopy and eliminates contact with the upper teeth. It does not require any special training in its use. The MacCoy Laryngoscope is useful for both routine and difficult intubation.

Humans↗

Video-enhanced visualization of the larynx and intubation with the Bullard laryngoscope--equipment report.

PURPOSE: A simple technical solution is presented to provide video transmission from the tip of a Bullard laryngoscope to a bedside video display, while the operator is still able to look through the viewing ocular of the Bullard laryngoscope during tracheal intubation. EQUIPMENT: This is achieved by insertion of an ultrathin fibreoptic video-endoscopic system into the working channel of the Bullard laryngoscope. Thereby the view from the distal blade tip is transmitted to a bedside monitor, without interfering with the use of the Bullards laryngoscope's original eyepiece. The presented technical solution allows video transmission without considerable additional weight normally associated with attaching video endoscopy cameras, light and camera cables to endoscopic devices. Thus, the Bullard laryngoscope remains lightweight and easy to maneuver. A screw-threaded adapter with a side-port is proposed to prevent displacement of the fibreoptic cable while still allowing application of oxygen. CONCLUSION: Experience and skills with tracheal intubation using the presented video-enhanced Bullard laryngoscope can be achieved in the originally intended way, while the supervisor or attending viewers can follow the tracheal intubation procedure on the video display.

Computer Terminals↗

[Laryngeal surgery with a 3-D technique. Early results with the jet-laryngoscope in superimposed high-frequency jet ventilation].

Surgery by three-dimensional (3D) endoscopy is being used routinely in abdominal surgery and, in special cases, in thoracic surgery; however, it has not been reported as being used in microlaryngeal surgery. METHODS. We inserted a 3-D endoscope into a jet laryngoscope and studied the pressure properties at the tip of the laryngoscope as well as intrapulmonary pressures while applying superimposed high-frequency jet ventilation. The studies were conducted initially using a lung simulator, and then in seven patients undergoing microlaryngeal surgery. RESULTS. Due to the rather large 3-D endoscope, the diameter of the jet laryngoscope was reduced by between 25.2% and 70.9%, depending on its size. The measurements on the lung simulator revealed that reduction of laryngoscope diameter leads to an increase in the following parameters: expiratory resistance, tidal volume, and peak inspiratory pressure. The mean FiO2 was 0.74 +/- 0.1; the mean paO2 was 169.2 +/- 80.4 mmHg; and the mean paCO2 was 40.9 +/- 2.4 mmHg. The mean airway pressure was 19 +/- 5.3 mmHg prior to insertion of the endoscope and 12.3 +/- 6.9 mmHg after insertion. The mean positive end-expiratory pressure values increased from 2 +/- 0.6 to 3.6 +/- 2.3 mmHg. Reduction of the working pressure resulted in restoration of the initial inspiratory pressures and tidal volumes. CONCLUSIONS. In the clinical application of 3-D endoscopy via a jet laryngoscope, it was possible to achieve sufficient ventilation, inspection of the surgical field, and performance of the surgical procedure. A CO2 laser was used without changing the ventilation regime. Although technical alterations would be desirable for its application to microlaryngeal surgery, it is presently possible to safely use the 3-D endoscope via the jet laryngoscope for microlaryngeal surgery, presenting the surgeon with new possibilities in voice-improving microsurgery of the larynx.

Aged↗

Propofol concentration required for endotracheal intubation with a laryngoscope or fiberscope and its interaction with fentanyl.

UNLABELLED: The administration of fentanyl with propofol reduces the blood concentration of propofol required to achieve adequate anesthesia for tracheal intubation. However, different intubation procedures have variable intensities of noxious stimulation and may require different levels of anesthesia. The goal of this study was to determine the propofol blood concentration at which 50% of patients did not respond to stimulation (Cp50) for laryngoscopy, intubation with a laryngoscope, insertion of a slotted oral-pharyngeal airway (Ovassapian airway), and intubation with a fiberscope when administered in conjunction with fentanyl. Patients undergoing elective surgery were given varying amounts of propofol or propofol with fentanyl, and their responses to the four procedures listed above were assessed. These experiments demonstrated that the propofol concentration required for intubation with a laryngoscope was similar to that for intubation with a fiberscope, and that the required level was reduced by fentanyl. Hemodynamic responses to intubation were lower with a fiberscope than with a laryngoscope. We conclude that almost the same concentrations of propofol or fentanyl are necessary for suppressing both of the somatic responses to tracheal intubation with a fiberscope or a laryngoscope. Hemodynamic responses were attenuated more during intubation with a fiberscope. IMPLICATIONS: The propofol blood concentrations at which 50% of patients did not respond to stimulation for laryngoscopy, tracheal intubation with a laryngoscope, and tracheal intubation with a fiberscope were 10.9, 19.6, and 19.9 microg/mL, respectively. These were reduced by fentanyl. Hemodynamic responses to intubation were less with a fiberscope than with a laryngoscope.

Adult↗

A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.

The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n = 30) laryngoscope. All patients were intubated by one of four anaesthetists experienced in the use of both laryngoscopes. No significant differences in demographic or airway variables were observed between the groups. All but one patient, in the Macintosh group, was successfully intubated on the first attempt. There was no difference between groups in the duration of intubation attempts. In comparison to the Macintosh laryngoscope, the Airtraq resulted in modest improvements in the intubation difficulty score, and in ease of use. Tracheal intubation with the Airtraq resulted in less alterations in heart rate. These findings demonstrate the utility of the Airtraq laryngoscope for tracheal intubation in low risk patients.

Adult↗

[Assessment of the practice of endotracheal intubation by levering Laryngoscope in teaching of undergraduate medical students].

Twenty-nine inexperienced medical students tried to intubate endotracheal tubes using both levering laryngoscope (McCoy laryngoscope) and Macintosh laryngoscope in adult mannikin the Cormack and Lehane Grade 2. The number of successful intubations by McCoy type was close to those by Macintosh type. Improvement in time necessary from insertion of the laryngoscope to confirmation of placement of the endotracheal tube McCoy type was also close to that by Macintosh type. But the grade of handling difficulty of McCoy type was significantly higher than that of Macintosh type, because Macintosh type was simpler to handle than McCoy type. It was suggested that Macintosh laryngoscope was more useful than McCoy laryngoscope for teaching of inexperienced medical students.

Adult↗