The evolution of the Buck-32 total hip prosthesis.

The total hip prosthesis designed by Buchholz has had an excellent clinical record. Despite its unique features, popularity in the United States has been lacking because of the large head size and the single-size neck length. The Buck-32 modification offers a 32 mm head with varying neck lengths, but retains the salient features of a longer stem and a ventral recess in the acetabular component. Laboratory studies demonstrate that the modified Buchholz prosthesis (Buck-32) does demonstrate an excellent range of motion, superior strength qualities, and excellent flexibility which allows its use in clinical conditions requiring maximum prosthetic strength.

Biomechanical Phenomena↗

Treatment of secondary osteoarthritis and rheumatoid arthritis by Bateman hip prosthesis.

The Bateman hip prosthesis was applied in reconstruction of secondary osteoarthritis and rheumatoid arthritis. Forty-five joints that could be followed up for 45-18 months (mean 26 months) were clinically and roentgenographically re-examined. Forty joints (90.0%) were painless. The clinical score improved from the preoperative mean of 44.8 to the postoperative mean of 87. In 34 patients with secondary osteoarthritis, postoperative protrusion of the outer head into the acetabulum reconstructed by excavation of the previous shallow, steep architecture was only 0.8 mm (mean). Postoperative protrusion of the outer head into the acetabulum reconstructed by bone grafting was only 2.0 mm (mean) in 11 patients with rheumatoid arthritis. Roentgenograms revealed the appearance of sclerosis supermedially in the excavated acetabulum 4-6 months after the operation. This sclerotic change expanded in the entire area of contact with the outer head in 36 of 45 joints within about 1 year. Once the sclerosis had spread completely, the outer head stopped protruding into the acetabulum. A computerized simulation experiment with a rigid spring model demonstrated that central displacement of the outer head can be avoided if the continuity between the sclerosis in the articular surface of the reconstructed acetabulum and the lateral wall is restored for transmission and dispersion of the resultant head force toward the lateral wall as in normal hip joints; this verified the clinical findings.

Acetabulum↗

[Medical environment of total hip prosthesis].

Total hip replacement is an extremely frequent operation for the treatment of degenerative joint disease. Indication for surgery must take into account the patient's general status, associated diseases, multiple joint involvement, and the efficacy and tolerance to medical treatments. The decision to operate is taken together by the physician and the patient. The degree of functional impairment and the patient's age are important factors. The patient must be informed that the period of hospitalization will be approximately 15 days and that good results are obtained in approximately 98% of the cases. Preoperative consultation with the anesthesist will focus on associated diseases with special attention to possible infectious foyers. Early post operative care includes a 48 hour antibiotic reginien, thromboprophylaxy with low molecular weight heparin for 3 days followed by anti-vitamin K for 6 weeks, and non-steroid antiinflammatory drugs for 5 days of up to 6 weeks in case of suspected risk of ossification. At mid-term, complications may include hematomas, infection and luxation. The fixation may also fail in certain cases where transtrochanter access was used. Long-term follow-up monitors for possible late onset infection and late luxations which usually result from prosthesis wear and more rarely from muscular causes.

Hip Prosthesis↗

Loosening of the socket in a 35-mm snap-fit prosthesis and the Charnley hip prosthesis. A roentgenographic evaluation of 321 cases operated upon because of osteoarthritis.

Migration and lucencies around the acetabular component were evaluated in serial roentgenograms of patients with osteoarthritis treated with total hip arthroplasty (THA); 207 were Charnley and 114 were Brunswik THAs. In this consecutive series of THAs followed for nine to ten years, the loosening rate (corrected for deaths and revisions) was significantly higher (35%-45%) in the Brunswik snap-fit sockets (bearing surface 35 mm in diameter) than in the Charnley sockets (5%-12%). Presumably, mechanical factors, i.e., friction torque and impingement, are responsible for the difference in durability between the two designs.

Aged↗

[Titanium modular revision prosthesis stem in revision hip prosthesis].

In revision arthroplasty of the hip, femoral defects and fractures must be bridged by a long stem. The implant has to be adapted exactly to the diameter of the cortical tube and has to be placed distally beyond the pathologic area. The titanium modular revision prosthesis (MRP) stem consists of the titanium alloy Ti6Al7Nb and is offered in various diameters, lengths, and special devices, which allows individual and load-stable reconstruction. The aim of the current study is to scrutinize first clinical and radiological results of the titanium MRP revision stem in revision arthroplasty of the hip. We report the midterm results of 130 non-cemented revision arthroplasties of the hip using the titanium MRP revision stem with a mean follow-up of 2.9 years (minimum: 1 year, maximum: 8 years), including 56 men and 74 women. The indication for revision arthroplasty was aseptic loosening of the cup and stem in 94 cases, loosening of the stem in 17 cases, reimplantation in a Girdlestone situation in 11, and periprosthetic fractures in 8 cases. The Harris hip score improved from 50.9+/-24.6 preoperatively to 88.5+/-11.5 postoperatively. The score according to Merle d'Aubigné improved from 9.8+/-4.0 preoperatively to 15.2+/-2.8 postoperatively. We found three recurrent dislocations, two lesions of the sciatic nerve, three cases of persisting deep infection, two periprosthetic fractures, and one case of subsidence of the stem of 2 cm required revision of the MRP stem. Atrophy of the proximal femur was visible in all cases with a stem diameter >17 mm (39/130). Stable primary fixation was achieved in 129 of 130 cases. The titanium MRP revision has proved to be a very reliable implant in cementless revision arthroplasty of the hip.

Aged↗

[Design, production and clinical application of custom total hip prosthesis].

The key to the research of the hip prosthesis is to prolong the effective using time of the hip prosthesis, but bone loss and aseptic loosening are the influential factors in this aspect. Since each person has his own characteristic, it is difficult for the standard hip prosthesis to fit with the patient's femoral canal, so the stability can not the ensured. Moreover, some patients have congenital abnormality or a serious defect in bone or arthrosis, which makes an obvious deviation from the normal, therefore they can not use the standard hip prosthesis. CAD/CAM is useful for to individual three-dimensional femoral reconstruction, which can improve the stability of the prosthesis and effectively prevent the loosening of prosthesis. This article introduces the advantage, design, production and the problems of custom CAD/CAM hip prosthesis.

Arthroplasty, Replacement, Hip↗

Conus hip prosthesis.

50 years ago, prosthetic replacement of the hip joint ushered in a new epoch in orthopaedics. Total hip replacement made it possible to remove a severely diseased, painful hip and restore normal function and a normal quality of life to the afflicted patient. The early results of total hip replacement are almost all spectacular and hip replacement has become the most successful type of orthopaedic surgery. These good results using an approach that was technically relatively simple resulted in a temptation to implant prosthetic hip joints with ever increasing frequency in ever younger patients. This led to the emergence of new problems, which were not so clearly recognised at the outset: it emerged that the stability of prosthetic hip joints was of limited duration. This had the following consequence: If a total hip prosthesis is implanted in an elderly person whose remaining life-expectancy is shorter than the longevity of the prosthesis, hip replacement is a life-long solution. We can therefore say that, for a patient who has only 10 to 15 years left to live, their hip problem is solved by total hip replacement. For young people, who still have a long life expectancy in front of them, it is different. They will experience failure of the artificial joint and require further surgery. The commonest and most important type of failure in total hip prostheses is aseptic loosening, which is associated with resorption of bone at the site of the prosthesis. The cause of this phenomenon has only gradually been recognised in the course of the years. Initially, the unanimous opinion was that the methacrylate cement, used to fix the components of the prosthesis in the bone, was the definitive cause of aseptic loosening because fissures and fractures of the cement were almost always found during surgical revision of loosened joints. There was talk of "cement disease" and great efforts were made to improve the quality of the cement and the cementing technique. Moreover, even today, there is no established answer to the question whether, over the course of many years, cement ages and becomes friable, a process that may have major implications for young patients. For this reason, ways of reliably fixing the prosthesis in the bone without methacrylate cement were also explored at the same time. Valuable pioneering work in this field was carried out with uncemented dental implants made of titanium and with a roughened surface. With these implants, the phenomenon of osseointegration, i.e. the deposition of bone directly on the roughened metal surface without any intervening connective tissue, was observed. This phenomenon has also been utilised successfully in hip prostheses: if artificial hips made of titanium alloy with a coarse-blasted surface and with a high primary mechanical stability are placed in the bone, osseointegration also occurs. In parallel with this development, Willert, from Göttingen, identified the most important cause of loosening of the prosthesis: he established that, when an artificial joint articulates, very fine particles of polyethylene are eroded from the prosthetic cup when the surfaces of the joint glide over one another and that these are only partially removed by the lymphatic system. A large proportion of the particles accumulates in the artificial joint and in the gap between the prosthesis and the bone, giving rise to foreign body granulomata, which resorb bone thus leading to loosening. The number of eroded particles is considerable. In 1998, Patricia Campbell, from Los Angeles, showed that 470,000 particles per step were produced from an articulation between a metal head and a polyethylene cup. This huge number gives an indication how small these particles are, since the linear erosion of the polyethylene surface only amounts to about 0.1 to 0.2 mm a year. This relatively recent recognition of "particle disease" has led to the investigation of other materials, which produce fewer erosion particles, for artificial joint articulations. Three possible options are available today, but it is not yet possible to decide for certain which of them is superior to the others: the longest experience has been with metal/metal articulation with articulatory pairings of cobalt/chromium/molybdenum alloy. In recent years, ceramic/ceramic articulations of aluminium oxide-ceramic and pairings of ceramic with highly crosslinked polyethylene have also been used. With these modern articulations, particle erosion can be reduced about 200 fold. If the erosion particles are an important cause of loosening of the prosthesis, it is reasonable to expect that, with these new joint pairings, the durability of an artificial joint can be substantially prolonged. The cone prosthesis described here has been developed on the basis of the knowledge and experience of the last 20 years. The conical anchoring of the stem, involving the placing of a conical implant in the conically reamed medullary cavity, results in continuous contact between the stem of the prosthesis and the bone, with a high degree of primary stability. The sharp longitudinal ribs on the stem, which cut a little into the bone, provide a high degree of rotational stability. In the case of conical fixation, the mechanical transmission of force varies with the diameter of the stem: the weight bearing surface of a cone in relation to its length is greater where the stem has a larger diameter than at the tip of the stem where the diameter is smaller. Therefore, for geometrical reasons, the conical fixation of the stem results in a transmission of force that is predominantly proximal and avoids proximal stress protection. The round cross-section permits free adjustment of the angle of anteversion and avoids any forced rotation as a result of bony deformity, which is very important in the case of dysplastic hips.

Adolescent↗

Hyaluronan in synovial fluid of patients with loose total hip prosthesis. Comparison with hyaluronan in patients with hip osteoarthritis and idiopathic osteonecrosis of femoral head.

The concentration and molecular weight of hyaluronan (HA) in the synovial fluid of the hip joint were determined in 13 patients (aged 62.8 +/- 9.4 years) who had undergone prior total hip arthroplasty(THA), 23 patients (aged 65.0 +/- 8.2 years) with osteoarthritis of the hip joint (OA), and 13 patients (aged 40.2 +/- 2.7 years) with idiopathic osteonecrosis of the femoral head (ION). A sample of synovial fluid was obtained during revision THA because of loosening of the total hip prosthesis for the THA group, and during the first replacement surgery or osteotomy for the OA and ION groups. The concentration of HA in the synovial fluid was 0.64 +/- 0.42 mg/ml in the THA group, 1.07 +/- 0.28 mg/ml in the OA group, and 1.30 +/- 0.56 mg/ml in the ION group. The concentration of HA in the synovial fluid of the THA patients was significantly lower than that of the OA and ION patients (P = 0.0156 vs OA, P = 0.003 vs ION). The molecular weight of HA was 309 +/- 88.3 x 10(4) Da in the THA group, 377 +/- 201 x 10(4) Da in the OA group, and 240 +/- 148 x 10(4) Da in the ION group; these values do not differ significantly (P = 0.259 vs OA, P = 0.174 vs ION). Among the THA patients, there was no relation between the concentration of HA and the age of the patient, length of time since the first operation, or type of prosthesis fixation; there was also no relation between the molecular weight of HA and each of these factors. These results suggest that a pseudosynovial membrane is regenerated after THA, and that it produces HA of the same molecular weight as that in patients with OA and ION, although in smaller quantities.

Adult↗

[Hydroxyapatite-coated total hip prosthesis. 3d-generation hip prostheses].

Since 1987, 80 hydroxyapatite-coated (HA) cementless total hip prostheses have been implanted. Thirty patients were examined 21 months post-operatively and the results compared with data for uncoated prosthesis. Earlier mobilisation and freedom from pain, together with evidence of bone ingrowth without connective tissue membrane formation, confirmed the benefits of HA-coated prostheses.

Aged↗

Biodynamic total hip prosthesis.

The biodynamic total hip prosthesis which was devised in 1977-78 and implanted in 1979 was derived from a series of experimental studies and a lengthy clinical experience, both dating back to 1968. This prosthesis introduced two new and original concepts into the field of prosthetic hip surgery: 1) the biequatorial design of the cup; 2) the preservation of the femoral neck. This prosthetic system is based on maximum preservation of the bone stock as well as hip function. The biequatorial cup allows for positioning corresponding to that of the normal acetabulum. The femoral component incorporates features (collar, sagittal and frontal angulation, external surface, etc.) which facilitate proximal cortical fixation and cancellous metaphyseal biological anchoring, thus ensuring total adhesion. The average 3.5 years follow-up (maximum 7 years, minimum one year) in 280 cases confirms the effectiveness of this prosthesis and the validity of the basic principles on which it is founded.

Adult↗

[The infected hip prosthesis].

Therapy of infected hip prosthesis should always be based on a structured treatment concept. When short-termed early infection is present or impending, with meticulous debridement of the soft tissue surroundings, the implant may be left in place. Chronic infection (>30 days) should lead to complete removal of implant and cement. A one-staged revision of the implant may be considered for patients without additional chronic disease, good vascularization of soft tissue and bones and bacteria susceptible to antibiotics. In most cases though two-staged revision is indicated. The interval between implant removal and re-implantation ranges between one and four months. Re-implantation should only be performed when laboratory parameters are normalized and the local wound site has turned to an unsuspicious condition. By insertion of a cement spacer during the interval period soft tissue shortening and local scar formation can be prevented. Parenteral antibiotics should be applied for four to six weeks. In patients with reduced general health state and extremely severe infection permanent resection of the hip or limp ablation may be indicated.

Arthroplasty, Replacement, Hip↗

-Arthrography of the hip prosthesis-.

Arthrography of hip arthroplasties is a safe, easy-to-perform procedure. It is mainly indicated when infection of the arthroplasty is suspected: the contrast agent fills bone defects that may be present between normal bone and the prosthesis and reaspiration of injected fluids may lead to bacteriological diagnosis. Another indication for arthrography of hip arthroplasties is unexplained painful hip prosthesis.

Arthrography↗

[Total hip prosthesis in coxarthrosis following congenital hip dislocation (65 hips reviewed at 5 years)].

In 45 patients, 65 hips with CDH were given a THR after 5 years or more, with an average follow up of 8.5 years. The results and the technical problems are discussed. Of those 65 hips, there were 46 anterior dislocations, 15 intermediate dislocations and 4 cases of posterior dislocation. The mean shortening was 58.3 mm. In all cases, the authors performed a total arthroplasty on the original acetabulum, after lowering and reconstruction of the acetabulum by grafts taken from the femoral head. There are some immediate postoperative complications: 12 thromboembolic complications, hematomas and 2 cases of paralysis of the peroneal nerve. There was loosening in 8 patients (12%), with 3 infections. The functional results were good in 85% and poor in 7.5%. Nevertheless, the limp was maintained in 49 patients. There was residual low back pain in 7 patients. In 14% a second operation on the homolateral knee was performed after an average time of 2 years. The technical problems are discussed: the cup should be placed in the original acetabulum and in evaluating the lowering of the acetabulum, the condition of the lumbar spine should be considered. Posterior luxation is discussed as well; the authors recommend prudence in the indication for THR operations with lowering of the acetabulum shell.

Adult↗

The development of a physiological hip prosthesis: evaluation of the strains after implantation of a prototype of hip implant: experiment in a dry femur.

Based upon previous research on the relation between hip prosthesis designs and strain distributions in a proximal femur model, a prototype of a "physiological" hip prosthesis was designed and manufactured. Strain gauge measurements on a dry femur before and after implantation of this prosthesis were made in different loading conditions simulating one-legged stance with and without torsional loading and two-legged stance. The strains in the outer cortex were within 10% of the physiological values along the whole medial side in all measurement conditions.

Biomechanical Phenomena↗

Results of conversion total hip prosthesis performed following painful hemiarthroplasty.

Fifteen of 18 cases who underwent conversion total hip prosthesis due to painful hemiarthroplasty, between 1992 and 1997, were investigated retrospectively. The 13 (86.6%) women and two (13.4%) men (mean age, 59 years) were followed up for an average of 32 months. Pre-operative and post-operative Harris hip scores were 36.4 (28 - 42) and 85.9 (69 - 98), respectively. In all cases the femoral component had more than 2 mm radiolucency in Gruen zones I, IV and VII, and five cases had acetabular protrusion; other cases had cartilage erosion. In the last follow-up of conversion total hip prosthesis, there was no radiolucency in either femoral or acetabular components. Comparing our results of conversion total hip prosthesis with primary total hip prosthesis results for femoral neck fractures in the literature we conclude that, in elderly patients with femoral neck fractures, primary total hip prosthesis has better results.

Adult↗

[Reconstructive surgery using a massive prosthesis in loosening of a hip prosthesis].

Thirteen cases with loosening of THR treated by a massive prosthesis are reviewed. In previous years, with more conservative surgery, the loss of bone stock was most important. The results after a long follow-up were satisfactory. This was a desperate procedure during a period without a bone-bank. Despite the major problems with failure of this procedure, the author still recommends it in elderly patients who need early mobilization or when the use of a bank-bone is not possible.

Adult↗