Search PubMedSearch

SEARCH · Search PubMed

Results for “Glaucoma Drainage Implants”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

60 records · Page 2Linked to original sources

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1 year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI = 3; DBS = 3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1 year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5 wt%) and increasing Sr contents (0.5, 1.0, 1.5 wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-α and TGF-β; with an enhanced TNF-α secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals

Cochlear Implantation in Sickle Cell Disease: A Systematic Review of Feasibility and Outcomes.

INTRODUCTION: Sickle cell disease (SCD) is associated with systemic complications, including sensorineural hearing loss (SNHL) from microvascular occlusion and chronic inflammation. Although reports link SCD to higher rates of SNHL, current evidence is limited by small sample size, varied audiologic methods, and lack of standardized screening. This systematic review summarizes available literature on SNHL and cochlear implantation (CI) in SCD. METHODS: A literature search of PubMed MEDLINE, Embase, Scopus, Web of Science, and CINAHL identified 79 citations. After removal of duplicates, 35 records were screened in Rayyan. Studies published between January 1, 2000, and June 30, 2025, were eligible if they reported patients with SCD who developed hearing loss and underwent CI. Nine full texts were reviewed, and 4 met the inclusion criteria. Screening and review were performed independently by 2 authors per PRISMA guidelines. RESULTS: Across 4 case reports, a total of 5 patients with SCD underwent CI, ranging in age from 2 to 42 years. Four presented with bilateral severe-to-profound SNHL and one with unilateral loss. Implantation was technically feasible in all cases, including patients with cochlear fibrosis or ossification requiring modified insertion techniques. Postoperative outcomes were favorable: all patients demonstrated reliable device function and low impedances. Only 60% showed meaningful auditory benefit, characterized by improved functional speech perception in 2 patients (40%) and access to the speech frequency range with hearing testing going from moderate/profound hearing loss to mild hearing loss in 3 patients (60%). Complications occurred in 2 patients (40%): one developed unilateral middle ear infection leading to meningitis, and another experienced a postoperative pulmonary embolism requiring anticoagulation. The remaining 3 patients (60%) had uncomplicated recoveries with reported improved hearing from moderate/profound hearing loss to mild hearing loss post implantation. CONCLUSION: While CI appears feasible in SCD, our findings suggest that additional data are needed to assess its effectiveness in this patient population. However, evidence is limited to case reports, and complications such as thromboembolism and rapid cochlear fibrosis highlight the need for close perioperative management. More comprehensive studies with larger sample size are required to define surgical risk, optimize management, and establish best practices for timely implantation in this population.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n = 50) of articles showed low risk-of-bias, while 7.4% (n = 4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Soft Tissue Volume Augmentation at Single Implant Sites Applying Collagen Matrices or Connective Tissue Grafts: 10-Year Follow-Up of a Randomized Controlled Trial.

AIM: To compare up to 10 years clinical, profilometric and patient-reported outcomes of implant sites previously augmented using a volume-stable collagen matrix (VCMX) or connective tissue graft (SCTG) in the aesthetic zone. METHODS: The original non-inferiority randomized controlled trial (RCT) enrolled 20 patients who received soft tissue volume augmentation with VCMX or SCTG at single implant sites. Clinical assessments and standardized measurements were performed at baseline after crown insertion and at 6 months, 1, 3, 5, 7.5, and 10 years. The primary outcome was mucosal thickness. Secondary outcomes included marginal bone levels (MBL), probing depth (PD), bleeding on probing (BOP), plaque control record, Pink Aesthetic Score (PES), OHIP-14 and buccal profilometric changes. Group comparisons were performed using mixed-effects and generalized estimating equation (GEE) models, which account for within-patient correlations due to repeated measurements and allow inclusion of all available data without requiring imputation for missing observations. RESULTS: Of the 20 originally enrolled patients, 10 (5 in the SCTG group and 5 in the VCMX group) were available for re-examination at 10 years. The adjusted between-group difference in mucosal thickness was -0.02 mm (95% CI -0.99 to 0.96). As the lower bound of the confidence interval remained above the prespecified non-inferiority margin of -1 mm, non-inferiority of VCMX was shown. Buccal contour changes were comparable during the early follow-up, while a trend toward a greater long-term contour decrease was observed in group VCMX (-0.31 mm [95% CI, -0.65 to 0.03]; p = 0.07). Mean PES values were 10.6 in the SCTG group and 9.6 in the VCMX group, with no significant between-group differences (p = 0.45). Both groups revealed high levels of oral health-related quality of life, with low median OHIP-14 scores (SCTG, 0.0; VCMX, 1.0; p = 0.26). CONCLUSION: These preliminary long-term findings showed no clinically relevant differences between SCTG and VCMX in terms of clinical, profilometric and patient-reported outcomes. While SCTG remains the reference standard, VCMX represents a less invasive alternative but with a slight tendency toward greater long-term contour reduction. CLINICAL SIGNIFICANCE: Volume-stable collagen matrices serve as a viable alternative to autogenous connective tissue grafts for peri-implant soft tissue volume augmentation, particularly in patients seeking a reduced morbidity, without compromising long-term clinical or aesthetic outcomes. TRIAL REGISTRATION: German Clinical Trials Register: DRKS00017484.

Humans

Influence of Concave Versus Convex Emergence Profiles on Midfacial Mucosal Stability-A Systematic Review With Meta-Analysis.

OBJECTIVES: To systematically evaluate the influence of concave versus convex emergence profiles on midfacial mucosal stability in partially edentulous patients restored with implant-supported single restorations. MATERIALS AND METHODS: A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted and registered in PROSPERO (CRD420251139042). An electronic search in MEDLINE (PubMed) and Embase was performed up to May 7, 2026. Eligible studies included RCTs comparing concave (test group) and convex (control group) transmucosal prosthetic designs and reporting midfacial mucosal level changes (mm). Data extraction and risk of bias assessment (RoB 2) were performed independently. A random-effects meta-analysis was conducted using weighted mean differences (MDs) and 95% confidence intervals (CIs). Heterogeneity was assessed using the I2 statistic and sensitivity analyses were performed to evaluate the robustness of the findings. RESULTS: Four RCTs including 144 implants with a 12-month follow-up were included. Of these, 128 implants contributed to the quantitative synthesis, with 66 implants allocated to the concave/modified emergence profile group and 62 implants allocated to the convex/non-concave emergence profile group. The pooled analysis demonstrated a mean difference of -0.31 mm (95% CI -0.63 to 0.02; p = 0.064), indicating a trend toward greater midfacial mucosal recession with convex emergence profiles compared with concave designs. Between-study heterogeneity was low to moderate (I2 = 28%), suggesting consistent findings across studies. Sensitivity analyses confirmed the direction of the effect, with pooled estimates ranging from -0.12 to -0.43 mm. Exclusion of one study resulted in a statistically significant difference favoring concave emergence profiles (-0.43 mm; 95% CI -0.70 to -0.16; p = 0.002). CONCLUSIONS: Convex emergence profiles are associated with a tendency toward increased midfacial mucosal recession. Concave profiles are preferable to support peri-implant soft-tissue stability. CLINICAL RELEVANCE: Emergence profile design should be considered an integral component of prosthetic and surgical planning. The use of concave transmucosal contours during provisionalization and definitive restoration may contribute to improved peri-implant soft tissue stability and enhanced esthetic outcomes.

Humans

Intravenous Tranexamic Acid Reduces Perioperative Blood Loss in Reduction Mammoplasty With Immediate Implant-Based Reconstruction: A Randomized, Triple-Blinded, Placebo-Controlled Trial.

BACKGROUND: Postoperative hematoma and oozing can compromise outcomes after reduction mammoplasty with immediate reconstruction. Intravenous (IV) tranexamic acid (TXA) is antifibrinolytic, but prospective evidence in this setting is limited. OBJECTIVES: The aim of this study was to determine whether a single pre-incision dose of IV TXA reduces perioperative blood loss and fibrinolytic activation vs placebo. METHODS: In this randomized, triple-blinded, placebo-controlled trial, 60 women (American Society of Anesthesiologists I/II, 18-75 years) undergoing bilateral reduction mammoplasty with immediate implant-based reconstruction received TXA 10 mg/kg in 100 mL saline or placebo 10 min before incision. The primary outcome was total blood loss within 24 h (intraoperative suction + swab plus drain output). Secondary outcomes were perioperative changes in hemoglobin, D-dimer and fibrinogen, and complications within 30 days. Intention-to-treat analyses were performed. RESULTS: All patients completed follow-up. Total blood loss was lower with TXA than with placebo (mean ± standard deviation: 221.1 ± 72.4 vs 298.1 ± 90.6 mL; mean difference -77.0 mL; 95% CI, -122.4 to -31.6; P = .001). Intraoperative loss and 24 h drain output were also reduced. Postoperative D-dimer rise was attenuated with TXA (0.31 ± 0.15 vs 0.49 ± 0.22 µg/mL; P = .002); hemoglobin decline was smaller. No thromboembolic, neurologic, or allergic events occurred; no skin-flap necrosis was observed. CONCLUSIONS: Pre-incisional IV TXA safely reduces perioperative bleeding and fibrinolytic activity after reduction mammoplasty. These findings support incorporation of IV TXA into perioperative protocols. LEVEL OF EVIDENCE: 2 (THERAPEUTIC): For image description, please refer to the figure legend and surrounding text.

Humans

Improved donor-site biomechanics and functional recovery with xenogeneic acellular dermal matrix after ALT flap harvest: A prospective randomized controlled study.

BACKGROUND: Donor-site management after anterolateral thigh (ALT) flap harvest is a significant yet underaddressed concern in reconstructive surgery for oral cancer. While xenogeneic acellular dermal matrix (Xeno-ADM) is common in soft-tissue repair, its efficacy for fascia lata reconstruction at the ALT donor site remains insufficiently characterized. This study aimed to assess the efficacy of xeno-ADM in fascia lata repair, focusing on compartment pressure, inflammatory and muscle injury biomarkers, and functional recovery. METHODS: In this prospective, randomized, single-blind trial, 200 patients undergoing ALT flap reconstruction were allocated to Xeno-ADM repair (n = 100) or primary closure (n = 100). Primary endpoints included compartment pressure, inflammatory markers in drainage fluid, serum muscle injury biomarkers, and functional outcomes. RESULTS: The xeno-ADM group showed significantly lower compartment pressures throughout postoperative days (POD) 1-5. Inflammatory markers in drainage fluid (CRP on POD 3 and 5) and serum muscle injury biomarkers (creatine kinase on POD 1 and 5) were significantly lower in xeno-ADM group. Functional outcomes were superior in the Xeno-ADM group, with faster gait recovery, lower pain scores at POD 7, and better lower-limb function at the 1- and 6-month follow-ups. Drainage duration did not differ between groups. Stratified analyses revealed that the benefits of xeno-ADM were more pronounced in patients with defect width >3 cm or a body mass index ≥24 kg/m2. CONCLUSION: Xeno-ADM provides a safe and effective approach for fascia lata repair, reducing biomechanical and inflammatory burdens while enhancing functional recovery. These findings support a transition from simple structural closure toward functional donor-site reconstruction.

Humans

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Effects of erector spinae plane block on postoperative pain in patients undergoing implant-based breast reconstruction for breast cancer: a randomized controlled trial.

BACKGROUND: Implant-based breast reconstruction after mastectomy causes acute pain. OBJECTIVE: To determine whether a single-shot T5 erector spinae plane block (ESPB) reduces postoperative pain. DESIGN: Single-center, RCT with allocation concealment; blinded assessors and statisticians. SETTING: Tertiary cancer center in China. PATIENTS: 100 adults scheduled for radical mastectomy with implant reconstruction were randomized (1:1); follow-up complete. INTERVENTION: Before induction, ESPB was given under ultrasound guidance at T5 with 30 mL of 0.375% ropivacaine plus dexmedetomidine 1 &#x3bc;g/kg; controls received no block. Standardized general anesthesia and postoperative PCA for both groups. MAIN OUTCOME MEASURES: Resting NRS at 6 h (MCID=1). Secondary outcomes were opioid consumption, quality of recovery, and PONV. RESULTS: ESPB did not significantly reduce resting pain at 6 h at the median (&#x3c4; =0.50; adjusted difference -0.9; p = 0.08). At the upper tail, pain intensity was lower (&#x3c4; = 0.75; -1.8; p <0.01). Repeated measures provided additional time-point information, improving estimation precision and test sensitivity. ESPB get lower pain scores at 6, 12, and 24 hours (all p <0.01). But, the 95% CI includes the MCID, the clinical benefit remains uncertain. Opioid use decreased at 24 h (-13.5 mg; p <0.01) and 48 h (-6.6 mg; p <0.01). Quality of recovery improved at 24 h (difference 5 points; p <0.01), but not later. No differences were observed in intraoperative hemodynamics or PONV. CONCLUSIONS: Single-shot T5 ESPB with perineural dexmedetomidine may reduce postoperative pain and opioid requirements and improve early recovery. Further large trials are warranted. Clinical relevance remains to be confirmed. TRIAL REGISTRATION: ClinicalTrials.gov NCT06143020.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Aortoesophageal Fistula: Mending the Lethal Connection-A Systematic Review and Meta-Analysis.

BACKGROUND: Aortoesophageal fistula (AEF) is a rare, life-threatening condition with limited high-quality evidence to guide management. METHODS: We conducted a systematic review and meta-analysis of PubMed and Scopus through December 2025, evaluating survival and complication outcomes according to treatment strategy and morphological severity. Patients were categorized into 5 groups: TEVAR alone, staged TEVAR followed by surgery, primary open or hybrid surgery, TEVAR with esophageal stenting, and supportive/palliative care. Outcomes were pooled as proportions with 95% confidence intervals (CIs). RESULTS: A total of 167 reports representing 528 patients were included. Overall 30-day mortality was 31.2% (95% CI 27.0% to 35.7%) and 1-year mortality 41.2% (95% CI 36.2% to 46.4%). Infection occurred in 32.6%, reintervention in 20.2%, and recurrence in 13.2%. Staged TEVAR followed by surgery showed favorable survival (30-day 12.7%, 1-year 26.1%) but high infection (66.7%) and reintervention (43.2%) rates. TEVAR with esophageal stenting had the lowest early mortality (5.0%) but frequent reintervention (54.5%) and 1-year mortality of 33.3%. TEVAR alone demonstrated the lowest 1-year mortality among definitive strategies (25.5%) but notable recurrence (26.9%). Primary open or hybrid surgery carried higher early and late mortality, while supportive/palliative care had the worst outcomes. Morphological severity correlated strongly with mortality, infection, reintervention, and recurrence, with type IV lesions showing particularly poor prognosis. CONCLUSION: Despite contemporary management, AEF carries high early and late mortality. Definitive strategies, particularly staged TEVAR followed by surgery, offer improved survival but increased complications. Morphology-guided, individualized management is recommended.

Adult

Efficacy and Safety of Autologous Versus Prosthetic Grafts in the Repair of Popliteal Artery Aneurysms: A Systematic Review and Meta-Analysis.

BACKGROUND: Popliteal artery aneurysms (PAAs) present a severe risk of progression to acute limb ischemia. Open surgery (OS) is the gold standard treatment; however, prosthetic grafts are acceptable in highly selected cases, especially when the great saphenous vein is not available. METHODS: We performed a systematic review and meta-analysis of studies comparing autologous versus prosthetic grafts for patency and limb preservation outcomes in patients with PAAs. MEDLINE, Embase, and Cochrane Central were systematically searched from inception through October 2024. Outcomes were pooled using a frequentist random-effects model as odds ratios, mean differences, and hazard ratios (HRs) with 95% confidence intervals (CIs) on RStudio (Version 4.5.0). Risk-of-bias assessments were performed using ROBINS-I and MINORS. RESULTS: Twenty-two observational studies were pooled comprising 9,145 PAAs in 8,370 patients, of whom 6,434 (74.51%) were treated with autologous grafts and 2,200 (25.49%) with prosthetic grafts. Follow-up ranged from 12 to 86 months. Repair with autologous conduits significantly improved long-term primary patency (HR 3.93; P < 0.001), secondary patency (HR 6.02; P < 0.001), and long-term limb salvage (HR 2.69; P = 0.044) compared with prosthetic conduits. There were no significant differences in in-hospital amputation (P = 0.36), myocardial infarction (P = 0.61), mortality (P = 0.50), 2-year primary patency (P = 0.25), 5-year secondary patency (P = 0.06), or length of hospital stay (P = 0.95). Risk of bias was classified as moderate-to-high, reflecting confounding factors inherent to observational studies and moderate methodological quality by MINORS. Despite these limitations, treatment effects consistently favored autologous grafts in both short- and long-term analyses; however, caution is warranted given the limited number of available studies. CONCLUSION: The use of autologous conduits significantly favors both short-term and long-term efficacy and safety in the OS repair of PAAs. Given the limitations of the existing evidence, further comparative studies are needed.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans