Search PubMedSearch

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

21 records · Page 2Linked to original sources

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y₂O₃ partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p ≤ 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Distal versus proximal radial access for diagnostic cerebral angiography: comparative outcomes and learning curve analysis.

BACKGROUND AND PURPOSE: Distal transradial access (dTRA) is an alternative to proximal transradial access (pTRA) for neuroangiography, but comparative real-world data and evidence on its early learning curve remain limited. We compared procedural performance and access-site complications between dTRA and pTRA and evaluated the early learning curve of dTRA. METHODS: We retrospectively analyzed 470 diagnostic cerebral angiography procedures, representing 421 unique patients, performed via radial access at a single center between January 2025 and February 2026, including 237 dTRA and 233 pTRA procedures. Baseline characteristics, including age, sex, body mass index (BMI) category, aortic arch type, and antiplatelet/anticoagulant use, procedural performance, and clinically assessed access-site events were compared between groups. Radial artery occlusion (RAO) was assessed by postoperative bedside pulse examination and confirmed with Doppler ultrasound when clinical findings were uncertain. Multivariable logistic regression was used to evaluate predictors of RAO, persistent bleeding or repeated compression, hand edema, and a composite access-site event endpoint. Because repeated procedures occurred in a subset of patients and event counts were limited, first-procedure sensitivity analysis and analyses of infrequent outcomes were interpreted cautiously. The dTRA learning process was assessed in the first 100 dTRA cases performed by a single operator using multivariable regression, cumulative sum (CUSUM) analysis, segmented trend analysis, and phase-based comparisons. RESULTS: Baseline characteristics were comparable between groups, including age, male sex, BMI category, aortic arch type, and antiplatelet/anticoagulant use. Compared with pTRA, dTRA was associated with more puncture attempts (3.0 [2.0-4.0] vs 2.0 [1.0-3.0], P&#xa0;<&#xa0;0.001), longer puncture time (2.0 [1.0-5.0] vs 2.0 [1.0-3.0] min, P&#xa0;=&#xa0;0.003), lower first-pass success (19.4% vs 35.2%, P&#xa0;<&#xa0;0.001), and a higher crossover rate (11.4% vs 6.0%, P&#xa0;=&#xa0;0.037). However, dTRA was associated with a lower clinically assessed RAO rate (2.5% vs 7.7%, P&#xa0;=&#xa0;0.011). On multivariable analysis, pTRA was independently associated with higher odds of RAO (OR 3.27, 95% CI 1.26-8.49, P&#xa0;=&#xa0;0.015) and the composite access-site event endpoint (OR 3.12, 95% CI 1.55-6.28, P&#xa0;=&#xa0;0.001). Similar findings were observed in a sensitivity analysis restricted to the first procedure per patient. In the first 100 dTRA cases, cumulative dTRA experience was independently associated with shorter total procedure time (beta&#xa0;=&#xa0;-0.074&#xa0;min/case, P&#xa0;=&#xa0;0.009), while CUSUM and moving-average analyses suggested that the major learning effect occurred within approximately the first 10-15 cases. CONCLUSIONS: In this retrospective single-operator cohort, dTRA was associated with lower clinically assessed RAO than pTRA despite greater access difficulty. The early learning effect was mainly reflected in shorter total procedure time. These findings support the feasibility of dTRA but should be interpreted cautiously given the study's observational design and limited anatomical data.

Humans

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans