Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flame Ionization”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Comprehensive two-dimensional gas chromatography with flame ionization and time-of-flight mass spectrometry detection: qualitative and quantitative analysis of West Australian sandalwood oil.

The use of gas chromatography (GC)-mass spectrometry (MS), GC-time-of-flight MS (TOFMS), comprehensive two-dimensional GC (GCxGC)-flame ionization detection (FID), and GCxGC-TOFMS is discussed for the characterization of the eight important representative components, including Z-alpha-santalol, epi-alpha-bisabolol, Z-alpha-trans-bergamotol, epi-beta-santalol, Z-beta-santalol, E,E-farnesol, Z-nuciferol, and Z-lanceol, in the oil of west Australian sandalwood (Santalum spicatum). Single-column GC-MS lacks the resolving power to separate all of the listed components as pure peaks and allow precise analytical measurement of individual component abundances. With enhanced peak resolution capabilities in GCxGC, these components are sufficiently well resolved to be quantitated using flame ionization detection, following initial characterization of components by using GCxGC-TOFMS.

Gas Chromatography-Mass Spectrometry↗

Stability studies of carbamate pesticides and analysis by gas chromatography with flame ionization and nitrogen-phosphorus detection.

As a result of thermal stability studies of carbamate pesticides, a method has been proposed for their direct determination by gas chromatography in the ranges 1-20 and 0.1-1 mg l(-1), using flame ionization and nitrogen-phosphorus detection, respectively. The method allows the determination of propham, propoxur, carbofuran, carbaryl, methiocarb, isopropoxyphenol and naphthol in powdered potato samples. The analytes were previously extracted with a light petroleum-dichloromethane (1:1, v/v) mixture and preconcentred by solid-phase extraction through a C8 cartridge. The recoveries obtained from spiked potato samples (n=4 replicates) at two concentration levels, 10 and 0.5 mg of pesticide per kg of sample, were in the ranges 72-115 and 50-73%, with relative standard deviations of 2-7 and 5-8%, respectively. The detection limits were 50-210 and 41-53 microg kg(-1) with flame ionization and nitrogen-phosphorus detection, respectively, and reaching the maximum residue levels, 0.05 mg kg(-1) for methiocarb and propoxur, set by the Real Decreto 280/1994 (based on the European directive).

Calibration↗

Determination of volatile residual solvents in traditional Chinese medicines by headspace solid-phase microextraction and cryogenic gas chromatography with flame ionization detection.

A method based on headspace solid-phase microextraction and cryogenic gas chromatography with flame ionization detection was developed for the determination of volatile residual solvents in traditional Chinese medicines. A laboratory-made cryogenic chromatographic system was used for the separation of 15 kinds of residual solvents. During the analysis, a 65 microm PDMS/DVB fiber was used to extract the residual solvents, the extraction time was controlled at 0 degrees C for 15 min, and the NaCl content of the sample was maintained at 30%. The limits of detection ranged from 0.08 (for octane) to 5000 microg/L (for ethanol), and the relative standard deviations were < 8%. The recoveries from spiked samples ranged from 88 to 112%. Trace levels of residual solvents in several traditional Chinese medicines were effectively identified and quantified.

Calibration↗

Microtrap modulated flame ionization detector for on-line monitoring of methane.

A microtrap for on-line analysis of trace methane was developed. Silicosteel tubing, 15 cm long, 1.02 mm i.d. and 1.59 mm o.d. was packed with Carbosphere 80/100 mesh and placed between the standard gas source and the flame ionization detector (FID) to be used as a preconcentrator and an injector. The sample stream was passed continuously through the microtrap that was heated at a fixed interval by an electric pulse. To achieve the highest adsorption and desorption efficiency, parameters affecting the response of the system were optimized, and adsorption temperature in the range of 25 to -50 degrees C was studied. The response from the microtrap as compared to that from direct-flame ionization detector was enhanced by as much as 260 times. The on-line microtrap system showed good linearity (r2 > 0.99), low detection limit (28.3 ppbv) and good long term stability (relative standard deviation, RSD of less than 5.0%). Therefore, this simple device is suitable for on-line analysis of trace methane and similar small molecules in the environment as in high purity gases.

Methane↗

Thin-layer chromatography-flame ionization detection Iatroscan system.

The thin-layer chromatography-flame ionization detection (TLC-FID) Iatroscan system is a technique which is still being evolved. Quantification with the TLC-FID system relies heavily on the accurate setting up and calibration of the instrument. An appreciation of the factors that influence the analysis can eliminate significant errors. At least a few of the numerous operating variables need to be fixed to obtain coherent results from different laboratories. Hydrogenation of the sample is recommended in order to improve quantification with the Iatroscan system. The improved reproducibility obtained with automatic sample spotters compared with manual spotting indicates that autosampling is highly advisable.

Chromatography, Thin Layer↗

Application of thin-layer chromatography with flame ionization detection to the characterization of organic extracts from diesel exhaust particulates.

Thin-layer chromatography with flame ionization detection has been applied to the analysis of organic extracts of diesel exhaust particulates. Non-volatile organics whose boiling points are higher than ca. 300 degrees C can be analyzed, with a detection limit of ca. 0.03 micrograms and a relative standard deviation of ca. 10%. The organic extracts are separated into aliphatics , aromatics and polars by the development procedure with n-hexane, and the polars can be separated further by using toluene as the solvent. Some examples of application are presented.

Chromatography, High Pressure Liquid↗

Prediction of relative response factors for flame ionization and photoionization detection using self-training artificial neural networks.

The relative response factors (RRFs) of a flame ionization detection (FID) system and two pulsed discharge photoionization detection (PID) systems with different discharge gases are predicted for a set of organic compounds containing various functional groups. As a first step, numerical descriptors were calculated based on the molecular structures of compounds. Then, multiple linear regression (MLR) was employed to find informative subsets of descriptors that can predict the RRFs of these compounds. The selected MLR model for the FID system includes seven descriptors and two selected MLR models for the PID systems with argon- and krypton-doped helium as the discharge gases, respectively, include six and five descriptors. The descriptors appearing in the MLR models were considered as inputs for the self-training artificial neural networks (STANNs). A 7-7-1 STANN was generated for prediction of RRFs of the FID system, and two STANNs with the topologies of 6-7-1 and 5-6-1 were generated for the two PID systems. Comparison of the results indicates the superiority of neural networks over that of the MLR method. This is due to the nonlinear behaviors of relative response factors for all type of detectors studied in this work.

Flame Ionization↗

Flame ionization detection after splitting the water effluent in subcritical water chromatography.

The coupling of subcritical water separation with flame ionization detection (FID) in the split mode has been investigated in this study. In order to keep the FID system stable during subcritical water separation, a Tee union was connected between the separation column and the FID system to split the water flow. The ratio of the water flow to the FID system over the flow-rate to a waste bottle varied depending on the dimension of capillary tubings and the total water flow-rate used. Separations of several carbohydrates, carboxylic acids, and amino acids were performed on commercially available columns using a laboratory-made subcritical water chromatography-FID system. The FID system was very stable in this split mode even at total flow-rate as high as 1.24 ml/min. The linear dynamic range was up to three orders of magnitude and the limit of detection (LOD) ranged from 38 to 111 ng (306-925 ng/microl injected) with split ratios of approximately 1:10 to approximately 1:17 (FID/waste bottle) for several analytes studied. However, the LOD can be significantly lowered by adjusting the dimensions of the restrictors to allow a higher percentage of the total flow to the FID system.

Chromatography, Liquid↗

Gas chromatographic analysis of therapeutic concentrations of maprotiline in serum, using flame-ionization detection.

For the measurement of the tetracyclic antidepressant maprotiline in human serum, a gas chromatographic method with flame-ionization detection has been developed. The assay specifications obtained are as follows: a precision (C.V) of 3.5-6.4%, and a relative recovery of 97-109% using amitriptyline as internal standard. The sensitivity of the assay from serum was 40 nmol/l. The applicability of the method has been shown by measuring steady-state serum levels of five inpatients. The steady-state serum levels of maprotiline given at a daily dosage of 75 mg varied from 272 to 570 nmol/l.

Anthracenes↗

Optimization of the coupling of high-temperature liquid chromatography and flame ionization detection application to the separations of alcohols.

The feasibility of coupling high-temperature liquid chromatography (HTLC) to flame ionization detection (FID) has been studied. FID parameter values (hydrogen flow-rate, air flow-rate and FID temperature), typically set in gas chromatography are rarely suitable for liquid chromatography. Best values depend obviously on the water flow rate which is defined depending on both column temperature and column internal diameter. The FID parameters were optimized according to the water flow-rate by means of an experimental design. The potential of the method is shown with some alcohol separations and the value of increasing column temperature while reducing the column diameter is highlighted.

Alcohols↗

Chromatographic analysis of blood lipids. Comparison between gas chromatography and thin-layer chromatography with flame ionization detection.

Intact human blood plasma lipids of different composition were analyzed by gas chromatography and thin-layer chromatography with flame ionization detection. The reproducibility of the results obtained by gas and thin-layer chromatography was compared. The main advantages and disadvantages of both methods for lipid analysis are discussed. Generally, the variability of the results measured by thin-layer chromatography in series and from day to day was greater than that obtained by gas chromatography.

Chromatography, Gas↗

Development and validation of a new gas flame ionization detector method for the determination of finasteride in tablets.

A simple, rapid, and sensitive method based on gas chromatography with flame ionization detection is described for the determination of finasteride in tablets. The method is based on the derivatization of finasteride with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 60 degrees C for 30 min. The method was validated for specificity, linearity, precision, accuracy, robustness, and limit of quantification. The degree of linearity of the calibration curves, the percentage recoveries of finasteride, and the limit of detection (LOD) and limit of quantification (LOQ) for the gas chromatographic method were determined. The assay was linear over the concentration range of 10 to 50 microg ml(-1) (R approximately 0.999). LOQ and LOD (signal/noise ratio = 10) were found to be 10 and 2 microg ml(-1), respectively. The method was found to be simple, specific, precise, accurate, and reproducible. All of the validation parameters were within the acceptance range. The developed method was applied successfully to estimate the amount of finasteride in tablets. The results were compared statistically with those obtained by the official method using t and F tests. There was no significant difference between the two methods with respect to mean values and standard deviations at the 95% confidence level.

Chromatography, Gas↗

A rapid and sensitive method for the determination of paraquat in plasma and urine by thin-layer chromatography with flame ionization detection.

A new method for the determination of paraquat in biological fluids has been developed. It involves thin-layer chromatography with flame ionization detection (TLC/FID) and simple solid-phase extraction with a disposable octadecylsilane column. This procedure allows direct loading of the samples on the disposable column. When Chromarod SII is used as the stationary phase and methanol-2N hydrochloric acid (2:3, v/v) as the mobile phase, recovery levels of paraquat in spiked materials are from 87.5 to 98.0%. This method can be used for samples of paraquat at levels as low as 50 ng.

Adult↗

Quantitative analysis of fatty acid methyl esters by capillary gas chromatography with flame-ionization detection: quadrupole and sector mass spectrometer.

The response of a flame-ionization detector and of two mass detectors, viz. a quadrupole mass spectrometer and a sector mass spectrometer, is described. A relationship between the amount of a fatty acid methyl ester and the relative response in the three detectors was found. The detectors were compared and their possible use for biological samples was discussed.

Carboxylic Acids↗

A new method to quantitate lipid contents in human platelets by thin layer chromatography with flame ionization detection.

Lipid contents in human platelets from 21 healthy adults were analysed using thin-layer chromatography (TLC) in combination with a flame ionization detector (FID). Samples of 0.3 microliter extracted from 10(8) platelets were chromatographed on quartz rods coated with silica gel (Chromarods), and calibrated with an FID using free cholesterol and phosphatidylcholine as standards. The weight percentage of neutral lipids in human platelets obtained in this study was 14.6% which consisted mainly of free cholesterol, while that of phosphatidylethanolamine was 24.9%, phosphatidylserine plus phosphatidylinositol 6.8%, phosphatidylcholine 35.2% and sphingomyelin 18.6%. Free cholesterol in 10(8) platelets was estimated as 7 micrograms and phospholipids as 46 micrograms from standard calibrations. The minimum amount detectable by this TLC-FID method was 0.05 micrograms of standard cholesterol acetate and 0.1 microgram of lipids from 10(8) human platelets. The reproducibility was quite satisfactory and the procedure could be performed quickly and simply.

Adult↗

Effect of polarity on the response of the flame ionization detector to halothane.

Prepared standards of halothane in oxygen were analysed using a Pye Series 104 gas chromatograph equipped with a heated head flame ionization detector and gas sampling valve. The adoption of a positive jet voltage expanded the linear dynamic range of the detector to cover the 0.5-9.0% by volume range, provided that a small (0.5-ml) sample loop was used.

Chromatography, Gas↗

Lipid content of human platelets quantitated by thin-layer chromatography in combination with flame ionization detection.

The lipid contents of human platelets from twenty-one healthy adults were analysed using thin-layer chromatography in combination with flame ionization detection. The weight per cent of neutral lipids in human platelets was 14.6%, which consisted mainly of free cholesterol, that of phosphatidylethanolamine 24.9%, phosphatidylserine plus phosphatidylinositol 6.8%, phosphatidylcholine 35.2% and sphingomyelin 18.6%. Free cholesterol in 10(8) platelets was estimated as 7 micrograms and phospholipids as 46 micrograms from calibration standards. The reproducibility was satisfactory and the procedure could be performed quickly and simply.

Adult↗

Response and linearity of different lipid compounds when analyzed by thin-layer chromatography with flame ionization detection.

The response an linearity were studied for about twenty different types of lipids in a quantitative thin-layer chromatographic system equipped with flame ionization detection (TLC-FID). For most compounds the response showed good linearity with loads from 0.4 to 15 micrograms. The relative response of cholesterol, sterol ester and wax ester in ratio to triglyceride was, however, found to depend on the concentration, and this should be taken into account in quantitative determinations. The relative response of different lipids varied from 0.6 for hydrocarbon to about 1.4 for cholesterol. The application of the TLC-FID technique for skin lipid separations is illustrated.

Animals↗