Fluorescent dyes for lymphocyte migration and proliferation studies.

Fluorescent dyes are increasingly being exploited to track lymphocyte migration and proliferation. The present paper reviews the properties and performance of some 14 different fluorescent dyes that have been used during the last 20 years to monitor lymphocyte migration. Of the 14 dyes discussed, two stand out as being the most versatile in terms of long-term tracking of lymphocytes and their ability to quantify lymphocyte proliferation. They are the intracellular covalent coupling dye carboxyfluorescein diacetate succinimidyl ester (CFSE) and the membrane inserting dye PKH26. Both dyes have the advantage that they can be used to track cell division, both in vitro and in vivo, due to the progressive halving of the fluorescence intensity of the dyes in cells after each division. However, CFSE appears to have the edge over PKH26 based on homogeneity of lymphocyte staining and cost. Two other fluorescent dyes, although not suitable for lymphocyte proliferation studies, are valuable tracking dyes for short-term (up to 3 day) lymphocyte migration experiments, namely the DNA-binding dye Hoechst 33342 and the cytoplasmic dye calcein. In the future it is highly likely that additional fluorescent dyes, with different spectral properties to CFSE, will become available, as well as membrane inserting fluorescent dyes that more homogeneously label lymphocytes than PKH26.

Animals↗

Combined demonstration of an intraneuronal fluorescent dye and formaldehyde-induced catecholamine fluorescence in the guinea pig superior cervical ganglion.

A method is introduced for combined demonstration of an intracellular fluorescent dye (Lucifer Yellow-CH) and of formaldehyde-induced catecholamine fluorescence using as a model individual postganglionic neurons projecting to small intensely fluorescent cells in the guinea pig superior cervical ganglion. The application of this method to the peripheral and central nervous system offers the opportunity of studying potential sites of communication between monoamine containing cells and selected neurons prior to detailed ultrastructural studies.

Animals↗

Use of a fluorescent dye to measure secretion from intact bovine anterior pituitary cells.

The fluorescent dye FM1-43 has been used to indicate membrane changes in individual bovine anterior pituitary cells exposed to secretory stimuli. After ten minutes incubation with FM1-43 (2 microM), cells showed three patterns of dye fluorescence: annular, partly filled and uniformly filled. FM1-43 fluorescence was increased in 61% of the cells by TRH (40 nM), a physiological stimulus for prolactin secretion, and in 89% of the cells by 60 mM external K+. The fluorescence also increased when cells incubated in the presence of quinpirole, a dopamine D2-receptor agonist which inhibits prolactin secretion, were exposed to raclopride, a D-2 antagonist. The increases in FM1-43 fluorescence caused by these treatments suggests that the dye acts as an indicator of secretion, possibly through incorporation into secretory vesicle membranes exposed on the cell surface during exocytosis. If the dye was washed away after loading, the fluorescence of partly and uniformly filled cells was retained and a rise in fluorescence could still be seen on stimulation by TRH. This suggests that some dye had been taken up by endocytosis and trapped in an intracellular compartment, which expanded through membrane recapture after TRH stimulation. FM1-43 could therefore be a useful probe for membrane cycling associated with secretory responses.

Animals↗

Carboxyfluorescein diacetate succinimidyl ester fluorescent dye for cell labeling.

Our objective was to study the properties of the carboxyfluorescein diacetate succinimidyl ester (CFDA-SE) and the methodology of cell labeling using CFDA-SE fluorescent dye. First, we analyzed the kinetics of CFDA-SE fluorescent dye intensity over time. Second, we determined the optimal concentration of CFDA-SE fluorescent dye for cell labeling. Third, we tested the toxicity of CFDA-SE fluorescent dye on labeled cells. Finally, we determined the optimal staining time of CFDA-SE fluorescent dye for cell labeling. The results show that the optimal concentration of CFDA-SE fluorescent dye for cell labeling varies according to different cell types. CFDA-SE fluorescent dye is non-toxic to cells as the cell death rate caused by CFDA-SE labeling is below 5%. The optimal cell labeling time was determined to be 8 min of incubation with CFDA-SE fluorescent dye. We concluded that the advantages of using CFDA-SE fluorescent dye for cell labeling are as follows: (1) the binding of CFDA-SE fluorescent dye to cells is stable; (2) CFDA-SE fluorescent dye is not toxic and does not modify the viability of labeled cells; and (3) CFDA-SE fluorescent dye is a suitable fluorochrome for cell labeling.

Animals↗

Projections of the rat trigeminal sensory nuclear complex demonstrated by multiple fluorescent dye retrograde transport.

The fluorescent dyes True Blue, Fast Blue, Nuclear Yellow and SITS were used to examine the connections of the rat brainstem sensory trigeminal nuclear complex (nV). Particular attention was paid to the following questions: do individual trigeminal neurons project to multiple targets via axon collaterals; and do primary afferent inputs to the various regions of nV arise from individual cells? Pairs of injections, using contrasting dyes, were made into the following target area combinations: ventrobasal thalamus-ipsilateral superior colliculus, cerebellum-contralateral thalamus, nucleus principalis of nV-contralateral thalamus, and nucleus principalis of nV-subnucleus caudalis of spinal nV. In general, numerous neurons throughout all subdivisions of nV and within the trigeminal ganglion were labeled by a single dye following the injections. In addition, many cells in a similar distribution were found to be doubly-labeled following such injection combination. These data demonstrate the existence of significant subpopulations of first- and second-order neurons that project to multiple targets via divergent axonal ramifications throughout the rat sensory trigeminal system.

Animals↗

The relation between dicarbocyanine dye fluorescence and the membrane potential of human red blood cells set at varying Donnan equilibria.

The fluorescence, F, of two dicarbocyanine dyes, diS-C3(5) and diI-C3(5), depends both on the membrane potential, E, and on the intracellular pH, pHc, or human red blood cells. Compositions of isotonic media have been devised in which the equilibrium Donnan potential, E, varies at constant pHc and in which pHc varies at constant E. Dye fluorescence measurements in these suspensions yield calibrations of +1.7 % delta F/mV for diS-C3(5) and +0.6 % delta F/mV for diI-C3 (5). While pHo does not affect F of either dye, changes in pHc of 0.1 unit at constant E cause changes of F equivalent to those induced by 2--3mV. Based on these results, a method is given for estimating changes in E from dye fluorescence in experiments in which E and pHc co-vary. The relation of F to E also depends in a complex way on the type and concentration of cells and dye, and the wavelengths employed. The equilibrium calibration of dye fluorescence, when applied to diffusion potentials induced by 1 microM valinomycin, yields a value for the permeability ratio, PK.VAL/PCl, of 20 +/- 5, in agreement with previous estimates by other methods. The calibration of F is identical both for diffusion potentials and for equilibrium potentials, implying that diC-C3(5) responds to changes in voltage independently of ionic fluxes across the red cell membrane. Changes in the absorption spectra of dye in the presence of red cells in response to changes in E show that formation of nonfluorescent dimers contributes to fluorescence quenching of diS-C3(5). In contrast, only a hydrophobic interaction of dye monomers need be considered for diI-C3(5), indicating the occurrence of a simpler mechanism of fluorescence quenching.

Cell Membrane Permeability↗

Fluorescent dyes modify properties of proteins used in microvascular research.

OBJECTIVE: Fluorescent dyes, used frequently to label proteins for microvascular experiments, are assumed to not alter the protein's physicochemical characteristics. We tested the validity of that assumption for two probes, bovine serum albumin (BSA) and alpha-lactalbumin. METHODS: Standard electrophoretic techniques were used to examine the influence of five fluorescent dyes on the following three properties of BSA: molecular size (sodium dodecyl sulfate-polyacrylamide gel electrophoresis [PAGE]); relative molecular charge (native PAGE); and isoelectric point (pI) (i.e., isoelectric focusing). Also examined were the influence of the dyes on the relative charge of alpha-lactalbumin (native PAGE). Paired measures of single-vessel flux were made using two commercial preparations of dye-BSA on porcine coronary arterioles and venules. RESULTS: The addition of fluorescein isothiocyanate (FITC) to BSA altered significantly its size (p < 0.01; n = 6), relative charge (p < 0.02; n = 7), and pI. The other dyes caused minimal, yet significant, changes on the relative charge of BSA without influencing size or pI. Only FITC altered the relative charge of alpha-lactalbumin. While arteriolar fluxes of FITC-BSA and tetramethyl rhodamine isothiocyanate (TRITC)-BSA did not differ (p = 0.43; n = 5), in venules the FITC-BSA flux was greater than the TRITC-BSA flux (p < 0.001; n = 6). CONCLUSIONS: The addition of fluorescent dyes, particularly FITC, alters the physicochemical characteristics of two widely used protein probes. These findings may affect the interpretation of microvascular permeability experiments performed using fluorescent dyes, and they suggest care in the selection of dyes for such experiments.

Animals↗

IMPACT OF FLUORESCENT DYES ON MUTATIONS IN NEXT GENERATION SEQUENCING LIBRARY GENERATION.

DNA labelling fluorescent dyes such as ethidium bromide have long been considered to be highly mutagenic during DNA replication. While recent studies have pushed back on this narrative, the intercalative nature of these dyes continues to raise the possibility that these dyes can induce mutations. The iconPCR instrument by n6tec uses fluorescent dyes to measure amplification in real time and to adjust cycling conditions. However, since this use of qPCR is preparative and not analytical, mutations introduced by fluorescent dyes would be propagated into the sequencing reaction. To address the impact of these dyes on downstream analyses, we have performed routine mutation calling as well as mutational signature analysis on samples amplified using the iconPCR in the presence of either SYBR or EvaGreen. Sequence analysis revealed very minimal impacts of dyes on the reactions, largely within the noise regimen with only subtle changes in mutation rates seen. Mutational signature analysis was unable to identify any key signatures assignable to the dyes in either substitutions or indel domains. The mutational impact of intercalating dyes during fluorescence-guided amplification is therefore minimal and can be disregarded in all but the most sensitive NGS applications.

Fluorescent Dyes↗

Thyroxine-binding globulin: characterization of the binding site with a fluorescent dye as a probe.

The fluorescent dye 1,8-anilinonaphthalenesulfonate competed with thyroxine for binding to thyroxine-binding globulin. Fluorescence analysis indicated that the dye bound to the globulin in a molar ratio of 1:1 and with an association constant (at 23 degrees C) of 4.19 x10(6)M(-1), and that thyroxine bound to the globulin in a molar ratio of 1:1 and with an association constant (at 23 degrees C) of 2.35x10(10)M(-1). Displacement of globulin-bound dye by thyroxine was shown by fluorescence quenching, and displacement of globulin-bound thyroxine by dye was demonstrated by ultrafiltration.

Binding Sites↗

Fluorescent dyes specific for quadruplex DNA.

Fluorescent dyes which are specific for duplex DNA have found a wide range of applications from staining gels to visualization of chromosomes. Porphyrin dyes have been found which are highly fluorescent in the presence of quadruplex but not duplex DNA. These dyes may offer a route to the specific detection of quadruplex DNA under biologically important conditions. There are three types of DNA quadruplex structures, and these may play important roles in telomere, centromere, triplet repeat, integration sites and other DNAs, and this first set of porphyrin dyes show some selectivity between the quadruplex types.

Animals↗

Membrane potentials in respiring and respiration-deficient yeasts monitored by a fluorescent dye.

Changes in fluorescence of 3,3'-dipropylthiodicarbocyanine iodide which had been equilibrated with suspensions of the wild-type yeast Saccharomyces cerevisiae and of respiration-deficient mutants were followed. The changes have been attributed to changes of yeast membrane potentials, since the fluorescence with wild-type yeast could be affected in a predictable manner by uncouplers and the pore-forming agent nystatin. As in other systems, a rise of steady-state fluorescence was ascribed to depolarization and a drop of the fluorescence to hyperpolarization. (1) A considerable rise in steady-state fluorescence was brought about by addition of antimycin A or some other mitochondrial inhibitors to respiring cells. A major part of the composite membrane potential monitored in intact yeast cells appeared to be represented by the membrane potential of mitochondria. (2) Addition of D-glucose and of other substrates of hexokinase, including non-metabolizable 2-deoxy-D-glucose, induced a two-phase response of fluorescence, indicating transient depolarization followed by repolarization. Such a response was not elicited by other sugars which had been reported to be transported into the cells by a glucose carrier or by D-galactose in galactose-adapted cells. The depolarization was explained by electrogenic ATP exit from mitochondria to replenish the ATP consumed in the Hexokinase reaction and the repolarization by subsequent activation of respiration. (3) In non-respiring cells only a drop in fluorescence was induced by glucose and this was ascribed to an ATP-dependent polarization of the plasma membrane. (4) Steady-state fluorescence in suspensions of respiration-deficient mutants, lacking cytochrome a, cytochrome b, or both, was high an remained unaffected by uncouplers and nystatin. This indicates that membranes of the mutants may have been entirely depolarized. A partial polarization, apparently restricted to the plasma membrane, could be achieved by glucose addition.

Antimycin A↗

Temperature sensitivity of the erythrocyte membrane potential as determined by cyanine dye fluorescence.

We have used the cyanine dye fluorescence technique to measure the membrane potential of human erythrocytes as a function of temperature. With erythrocytes starved of glucose, there is an abrupt decrease in membrane potential centered at 38 degrees which is reversible up to 41 degrees, and irreversible at higher temperatures. With erythrocytes supplemented with glucose, the thermally induced transition is centered at 41 degrees and is reversible up to the highest temperature measured, 45 degrees. These results extend previous spectroscopic studies with erythrocyte membranes which demonstrated a thermally induced transition in protein tertiary or quaternary structure that is irreversible above 42 degrees.

Diffusion↗

Differentiation of EC cells in vitro by the fluorescent dye Hoechst 33342.

The fluorescent dye Hoechst 33342 is able to differentiate F9 EC cells at low concentrations. This differentiation is accompanied by synthesis of large amounts of laminin, production of a well-developed cytoskeleton, disappearance of the SSEA-1 antigen, and synthesis of large amounts of fibronectin, all characteristics of the primitive endoderm. The dye immediately blocks the cells at the S/G2 phase of the cell cycle and produces a complete arrest in proliferation. This effect is not specific for the nullipotent F9 cell line, as multipotent EC cell lines like PCC3, P19, and PCC4 can also be easily differentiated into the same pathway by treatment with the Hoechst dye. In contrast, the dye has no remarkable effects on terminal differentiated, immortalized cells like NIH 3T3 or the parietal endoderm-like cell PYS-2.

Animals↗

Measurement of cytosolic Ca2+ concentration in Limulus ventral photoreceptors using fluorescent dyes.

Several Ca-sensitive fluorescent dyes (fura-2, mag-fura-2 and Calcium Green-5N) were used to measure intracellular calcium ion concentration, Cai, accompanying light-induced excitation of Limulus ventral nerve photoreceptors. A ratiometric procedure was developed for quantification of Calcium Green-5N fluorescence. A mixture of Calcium Green-5N and a Ca-insensitive dye, ANTS, was injected in the cell and the fluorescence intensities of both dyes were used to calculate the spatial average of Cai within the light-sensitive R lobe of the photoreceptor. In dark-adapted photoreceptors, the initial Cai was 0.40 +/- 0.22 microM (SD, n = 7) as measured with fura-2. Cai peaked in the light-sensitive R lobe at 700-900 ms after the onset of an intense measuring light step, when the spatial average of Cai within the R lobe reached 68 +/- 14 and 62 +/- 37 microM (SD, n = 5) as measured with mag-fura-2 and Calcium Green-5N, respectively. The rate of Cai rise was calculated to be approximately 350 microM/s under the measuring conditions. The resting level of Mg2+ was estimated to be 1.9 +/- 0.9 mM, calculated from mag-fura-2 measurements. To investigate the effect of adapting light on the initial Cai level in the R lobe, a 1-min step of 420 nm background light was applied before each measurement. The first significant (P < 0.05) change in the initial level of Cai occurred even at the lowest adapting light intensity, which delivered approximately 3 x 10(3) effective photons/s. The relative sensitivity of the light-adapted photoreceptors was linearly related to the relative Cai on a double log plot with slope between -4.3 and -5.3. We were unable to detect a Cai rise preceding the light-activated receptor potential. The Cai rise, measured with Calcium Green-5N, lagged 14 +/- 5 ms (SD, n = 32) behind the onset of the receptor potential at room temperature in normal ASW. In the absence of extracellular Ca2+ and at 10 degrees C, this lag increased to 44 +/- 12 ms (SD, n = 17).