Cross-contamination with dental equipment.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
To estimate worker exposures to, and environmental contamination from, test chemicals and organic solvents used in an in vitro assay to assess the carcinogenic potential of chemicals, sodium fluorescein, a noncarcinogenic fluorescent material, was dissolved in tissue culture medium used to maintain early passage hamster embryo cells. Personal an environmental samples were taken over a 14-d period. The assay was performed according to standard procedures in a ventilated glove box or laminar flow safety cabinet. Considerably more than 99% of the chemical contamination found was recovered from the interiors of the glove box and hood and from disposable equipment. Contamination outside the containment units (less than 1 microgram) resulted from intralaboratory transport of chemicals, treated cultures, and contaminated equipment. We conclude that the standard operating particles and procedures provided adequate safeguards for personnel and the environment.
Cross-infection by contaminated equipment is a potential hazard associated with conscious sedation with nitrous oxide and oxygen . Nosocomial infections have occasionally been linked wih the use of unsterile inhalation devices; microbial contamination of sterile nasal hoods routinely occurs during administration of nitrous oxide; and in vitro experiments indicate that subsequent use of contaminated nasal masks may lead to aspiration of microorganisms. Although the incidence of respiratory disease after such contamination is unknown, it is clear that disinfection of the nitrous oxide apparatus between patients is desirable. A simple cleaning method involving alkaline glutaraldehyde is described that provides adequate disinfection of the rubber goods used in the administration of gas. Superiority of this technique over previously recommended cleaning methods is shown.
Bleach solutions containing the active ingredient hypochlorite (OCl-) serve as powerful biological disinfectants but are highly caustic and present a significant compatibility issue when applied to contaminated equipment or terrain. A neutral, bicarbonate-buffered aqueous solution of Oxone (2K2HSO5.KHSO4.K2SO4) and sodium chloride that rapidly generates hypochlorite and hypochlorous acid (HOCl) in situ was evaluated as a new alternative to bleach for the inactivation of biological agents. The solution produced a free chlorine (HOCl + OCl-) concentration of 3.3 g/L and achieved > or =5.8-log inactivation of spores of Bacillus atrophaeus, Bacillus thuringiensis, Aspergillus niger, and Escherichia coli vegetative cells in 1 min at 22 degrees C. Seawaterwas an effective substitute for solid sodium chloride and inactivated 5 to 8 logs of each organism in 10 min over temperatures ranging from -5 degrees C to 55 degrees C. Sporicidal effectiveness increased as free chlorine concentrations shifted from OCl- to HOCl. Neutrally buffered Oxone-chloride and Oxone-seawater solutions are mitigation alternatives for biologically contaminated equipment and environments that would otherwise be decontaminated using caustic bleach solutions.
OBJECTIVES: The objective of this study was to analyze the characteristics and costs of exogenous endoscopy-related infections, pseudo-infections, and toxic reactions in the US. METHODS: A systematic review of the scientific literature published between 1966 and 2005 was conducted in Medline. Data collection was based on a prospective protocol developed by the authors. RESULTS: The literature review included 70 outbreaks described in 64 scientific articles. Bronchoscopy accounted for half of all reported outbreaks. Inadequate decontamination practices were the leading cause of contamination; equipment malfunction became the second leading cause of contamination during the period 1990-2004. More than 91% of the infections identified could be prevented by health care providers if quality control systems are improved and implemented. The available economic information concerning exogenous endoscope related events is very limited. A model for the analysis of the economic burden of exogenous endoscopy-related events is proposed. CONCLUSIONS: Proper decontamination practices, the use of protective sheaths, and the improvement of surveillance systems could reduce the clinical and economic burdens associated with exogenous endoscopy-related events.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: Transmission of bacterial and viral pathogens is known to occur by hand contact with fomites. Exercise equipment in public facilities may serve as such fomites. It is not known whether equipment disinfection might reduce microorganism colonization. We performed studies to address these issues. DESIGN: Observational study of bacterial and viral culture results from hand-contact surfaces of exercise equipment, pre-exercise and postexercise; prospective study of viral culture results before and after intervention with disinfection solution. SETTING: Two fitness centers in a military community. INTERVENTION: One week trial of twice-a-day equipment disinfection. MAIN OUTCOME MEASURES: Type and number of bacteria and type of viruses present on equipment before and after exercise; prevalence of viral culture positivity on equipment before and after intervention. RESULTS: Bacterial cultures of body contact surfaces on equipment revealed benign bacterial species (coagulase-negative staphylococci, diphtheroids, and so forth) but no pathogenic bacteria whether obtained pre-exercise or postexercise, or whether from aerobic versus weight training equipment. Viral cultures revealed the presence of viruses (generally rhinoviruses) on 63 of 100 (63%) hand-contact surfaces of equipment. Weight equipment was significantly more often contaminated than aerobic equipment (73% vs. 51%; P = 0.026). Disinfection of equipment did not lower the prevalence of virus isolation (48% positive before cleaning; 86% positive after cleaning). CONCLUSIONS: There is little risk of exposure to pathogenic bacteria on exercise equipment. Such equipment may commonly serve as fomites for the transmission of viruses. These data do not suggest that disinfection of exercise equipment will offer significant protective effects against virus exposure.
Patients undergoing endoscopy are at risk of infection from the use of contaminated equipment. Dangers arise from the transmission of organisms from one patient to another and from the introduction of opportunist organisms which colonize endoscopic equipment on storage and can lead to sepsis and death in those who are immunocompromised and at ERCP. Staff are in danger from needle-stick injury and sensitivity to aldehyde disinfectants. These risks can be eliminated by careful attention to disinfection techniques. The most important part of endoscope disinfection is thorough mechanical cleaning first, followed by 5-10 min total immersion of the instrument and all channels in 2% glutaraldehyde (or the equivalent). At the end of the endoscopy list, following the disinfection protocol, all equipment should be dried internally and externally prior to storage. Staff must be fully aware of the risks of infection in endoscopy, be protected from hepatitis B by vaccination, and be fully trained in disinfection techniques. Glutaraldehyde should be used only in closed systems or in well-ventilated areas with the operator protected from direct contact from splashing and fumes. Institutions should designate an individual to be responsible for preparing, monitoring and overseeing disinfection procedures within the endoscopy room and for ensuring that regular microbiological testing of equipment (including automatic disinfecting machines) is undertaken.
BACKGROUND: Physicians often have anecdotal reports of patients describing increased asthma symptoms after the use of nebulizers; however, there are few published reports of nebulizer-associated exacerbations. OBJECTIVE: To present 2 cases of asthmatic children who experienced a life-threatening exacerbation of their symptoms after nebulizer use. METHODS: Case 2's nebulizer was tested for cockroach allergen by washing the medication reservoir with 2 mL of sterile filtered 1% phosphate-buffered saline, 0.05% bovine serum albumin, and Tween 20 overnight with rotation. The patient's sealed albuterol nebulizer medication was used as a control. The control albuterol and test solutions were analyzed for Blattella germanica 1 and 2 allergens using a monoclonal antibody-based immunoenzymetric assay. RESULTS: The reservoir from case 2 was found to have measurable levels of both Bla g 1 and Bla g 2. The control albuterol solution had no measurable cockroach allergen. An insect found in the nebulizer box of case 2 was identified as an infantile German cockroach. CONCLUSIONS: Nebulizer use provides an opportunity for antigen exposure directly to small airways, which may lead to severe allergic reactions in patients using contaminated equipment.
Human hepatitis B virus (HBV) is an important cause of nosocomial infections and can be transmitted by contaminated instruments. However, tests of the efficacy of sterilization of materials and equipment contaminated by HBV are difficult to perform because the virus cannot be cultured in the laboratory. In this study, we aimed to evaluate the capability of a low temperature, hydrogen peroxide gas plasma sterilizer (Sterrad, Advanced Sterilization Products, Irvine California,) to inactivate duck hepatitis B virus (DHBV). In laboratory efficacy studies using DHBV dried on to glass filter carriers and exposed to one-half of the hydrogen peroxide gas plasma sterilization process, there was a 10(7) or greater decrease in the viral titer, with no infectivity detected on the carriers after treatment. In-use studies were performed using a laparoscope that was experimentally contaminated with DHBV to mimic the possible transmission of infection between successive patients. Following exposure to the hydrogen peroxide gas plasma sterilization process no transmission of DHBV infection from the laparoscope occurred despite obvious visual soiling with blood (N = 8) while the transmission rate for the unprocessed laparoscope (positive control) was 100% (26/26), and that for instruments after a water wash was 63% (7/11). In conclusion the hydrogen gas plasma sterilization process completely inactivates DHBV a representative of the hepadna group of viruses.