Immunodiagnosis of human cysticercosis (Taenia solium): a field comparison of an antibody-enzyme-linked immunosorbent assay (ELISA), an antigen-ELISA, and an enzyme-linked immunoelectrotransfer blot (EITB) assay in Peru. The Cysticercosis Working Group in Peru (CWG).

We compared results of an enzyme-linked immunosorbent assay (ELISA) and an enzyme-linked immunoelectrotransfer blot (EITB) assay for the diagnosis of cysticercosis in sera and cerebrospinal fluid (CSF). Sera from 34 patients with confirmed cysticercosis were tested by both ELISA and EITB assays. Cerebrospinal fluid from some of these patients was also tested by ELISA for the presence of antibody (AB-ELISA) (n = 21) and antigen (AG-ELISA) (n = 15). Specificity in sera was examined by testing 51 serum samples from Bangladesh, where cysticercosis is not endemic. Cross-reactivity was evaluated in sera from patients with Echinococcus granulosus (hydatid) and Hymenolepis nana infections. Sensitivity in detecting cysticercosis in sera was 94% by EITB and 65% by AB-ELISA (P less than 0.01). Sensitivities in the CSF tested by EITB, AB-ELISA, and AG-ELISA were 86%, 62%, and 67%, respectively. The specificity of the EITB was 100%, while that of AB-ELISA was 63% (P less than 0.01). Cross-reactions occurred in the AB-ELISA with 11% and 20% of sera from hydatid and H. nana patients, respectively. Our results demonstrate that the EITB is the best assay available for the diagnosis of cysticercosis in both sera and CSF.

Animals↗

Chagas' disease diagnosis: comparative analysis of recombinant ELISA with conventional ELISA and the haemagglutination test.

BACKGROUND AND OBJECTIVES: Serological screening for Chagas' disease in the blood banks of South America is carried out by using two different assays that generally show a high number of inconclusive results. To establish a combination of two tests that can minimize the number of inconclusive results, we compared a recombinant enzyme-linked immunosorbent assay (ELISA) with two conventional tests. MATERIALS AND METHODS: Serum samples from chagasic patients (n = 112), from non-chagasic individuals (n = 143) and from patients with other diseases (n = 32) were tested using three assays: recombinant ELISA (Rec-ELISA); conventional ELISA (Con-ELISA); and the indirect haemagglutination (IHA) test. RESULTS: When we evaluated the data by matching the Rec-ELISA and the IHA test, 52 inconclusive results were obtained. When Rec-ELISA and Con-ELISA were matched, only four inconclusive results were observed. CONCLUSIONS: Our investigation indicates that the use of two ELISAs with different antigen preparations provides an effective test combination for blood bank screening of Chagas' disease.

Adult↗

[Assay of specific anti-Chlamydia pneumoniae antibodies by ELISA method. 1. Evaluation of ELISA kit using outer membrane complex].

Studies were conducted with the goal of developing a kit for assaying anti-Chlamydia pneumoniae antibodies in human serum which would enable judging positive cases with high specificity by means of an objective numerical index. Thus, an enzyme-linked immunosorbent assay (ELISA) method employing a C. pneumoniae outer membrane complex protein was established. Elementary bodies (EB) were purified from the YK-41 strain of C. pneumoniae, and subsequent treatment with Sarkosyl, DNase and RNase yielded chlamydial outer membrane complex (COMC). COMC was employed as the antigen and immobilized on 96-well microplates for ELISA method. This ELISA method was used to test 51 serum specimens from patients who had been demonstrated to be positive for C. pneumoniae antigen (throat swab: PCR positive), and the levels of IgG, IgA and IgM antibodies were assayed. For each specimen, comparison was made with the antibody titers determined by the micro immunofluorescence test (Micro-IF method). The results showed good correlation coefficients of 0.950 for IgG, 0.852 for IgA and 0.866 for IgM. In addition, the two assay methods showed the following high agreement rates: 90.2% for IgG, 84.3% for IgA and 82.4% for IgM. Specimens which did not yield the same results with the ELISA method and Micro-IF method were subjected to analysis by Western blot method, and the rates of agreement with the ELISA results were 80% for IgG, 87.5% for IgA and 88.9% for IgM. These data indicate the efficacy of this new ELISA method. Moreover, COMC was reacted with mouse antisera to three Chlamydia species, and the mouse IgG antibody was assayed. Anti-C. pneumoniae antiserum showed the strongest reactivity, whereas weaker reactivity was shown by anti-C. trachomatis antiserum (1/32nd of the reactivity of the anti-C. pneumoniae antiserum) and anti-C. psittaci antiserum (1/4th). In addition, sera from patients infected with C. trachomatis or C. psittaci (Psittacosis) were subjected to the ELISA method using COMC from C. pneumoniae. It was found that the correlation between the ELISA and Micro-IF methods was higher in relation to the anti-C. pneumoniae antibody titer than either the anti-C. trachomatis antibody titer or anti-C. psittaci antibody titer. These findings indicate this new assay kit based on the ELISA method has high specificity for C. pneumoniae.

Animals↗

Cell surface proteins of Helicobacter pylori as antigens in an ELISA and a comparison with three commercial ELISA.

Cell surface proteins of Helicobacter pylori were solubilized by extraction with acidic glycine buffer, N-octyl-glucoside, lithium chloride, and distilled water, and by sonication. The preparations were evaluated as antigens in ELISA to detect serum IgG responses in patients and healthy subjects. SDS-PAGE analyses of the preparations from a type strain (NCTC 11637) and of acidic glycine extracts of 4 clinical isolates showed multiple protein bands. The sera were classified as HP+ve and HP-ve by culture of biopsy and immunoblotting. Sera were considered positive for H. pylori if they detected the specific 120kD antigen or 4-5 other bands. 49 sera were HP+ve; the 51 HP-ve sera did not react in immunoblotting. 35/44 sera (80%) that reacted with the 120kD antigen demonstrated high titers in ELISA with all antigen preparations, and the remaining 9(20%) sera gave discordant results. 4/5 HP+ve sera that did not react with the 120kD antigen, demonstrated high ELISA titers with all 5 antigen preparations. Glycine extracts of 3 isolates did not exhibit the 120kD protein, but were equally sensitive in ELISA. The role of 120kD antigen in our ELISA was not clear. Immunoblotting demonstrated that the 5 antigen preparations share similar antigenic components. All preparations were similarly high in sensitivity and specificity, indicating that surface antigens could be satisfactorily used in our ELISA. Our ELISA using the glycine extract was compared with commercial H. pylori ELISAs developed by Bio-Rad Laboratories, USA (GAP ELISA), Roche, Switzerland (EIA 2G), and Whittaker Bioproducts, USA (Pyloristat).(ABSTRACT TRUNCATED AT 250 WORDS)

Antibodies, Bacterial↗

Comparison of complement fixation test, immunoblotting, indirect ELISA, and competitive ELISA for detecting antibodies to Mycoplasma mycoides subspecies mycoides small colony (SC) in naturally infected cattle from the 1995 outbreak in Botswana.

Four serological tests were compared in order to evaluate their efficacies in detecting antibodies to M. mycoides subspecies mycoides SC in cattle sera sampled in 1995 from herds affected with contagious bovine pleuropneumonia (CBPP) in the north-western part of Botswana. Tests that were compared included immunoblotting test (IBT), indirect enzyme-linked immunosorbent assay (i-ELISA), competitive enzyme-linked immunosorbent assay (c-ELISA) and complement fixation test (CFT). The percentages of seropositive samples in the iELISA (48%) and in the c-ELISA (48%) were similar but were comparatively lower than those obtained by the IBT (57%) and CFT (61%). The percentages of positive sera in the IBT and CFT were also similar and overall the efficacy of these tests was better than that of the two ELISA tests. There was 95.5% agreement between the IBT and CFT, 85% agreement between the IBT and c-ELISA, 90.9% agreement between the IBT and i-ELISA, 88.6% agreement between the i-ELISA and CFT, 80% agreement between the c-ELISA and CFT and 90% agreement between the two ELISA tests. It became clearly evident from this comparative study that no single serological test was capable of detecting all animals affected by CBPP under natural field conditions of infection.

Animals↗

Determination of IgM and IgG antibodies to Toxoplasma using the IFA test, ELISA, and Dot-ELISA procedures.

The dot enzyme-linked immunosorbent assay (Dot-ELISA) and the enzyme-linked immunosorbent assay (ELISA) were compared with the immunofluorescent antibody test (IFA) for detection of IgM- and IgG-specific antibodies to human toxoplasmosis. Reciprocal titers were determined in all three assays using sera from 56 patients with suspected toxoplasmosis or with symptoms and diseases requiring exclusion of toxoplasmosis and control sera from 56 healthy persons. Using the Dot-ELISA, six patient sera (10.7%) were positive at titers of greater than equal to 1024 for IgM antibodies (titer range 1024-16 384) and 47 sera (84%) were positive for IgG antibodies (titer range 16-262 144) at a titer of greater than or equal to 16. One control serum was reactive for IgM (titer 1024) and 10 control sera (18%) were positive for IgG in the Dot-ELISA. In the ELISA, at titers of greater than or equal to 128, five sera (9%) were reactive for IgM (titer range 128-512) and 52 sera (92.8%) were reactive for IgG (titer range 32-8192) at a titer of greater than or equal to 32; no control sera gave positive reactions for IgM while 10 sera (18%) were positive for IgG in the ELISA. Using the IFA test at reciprocal titers of greater than or equal to 16, four sera (7.1%) were positive for IgM (titer range 32-512), and 51 sera (91%) were positive for IgG (titer range 16-8192). None was reactive for IgM, and eight sera (14%) were positive for IgG (titer range 32-128) in the IFA test. The Dot-ELISA correlated well with the IFA test (correlation coefficient = 0.895) and the ELISA correlated slightly higher with the IFA test (correlation coefficient = 0.910) for detection of IgG antibodies to Toxoplasma gondii.

Enzyme-Linked Immunosorbent Assay↗

A micro-capture ELISA for detecting Mycoplasma pneumoniae IgM: comparison with indirect immunofluorescence and indirect ELISA.

A mu-capture ELISA was developed for detecting Mycoplasma pneumoniae-specific IgM, and compared with an indirect immunofluorescent antibody (IFA) technique and an indirect ELISA. mu-capture ELISA and IFA compared well and were found to be the most sensitive assays. The IFA test can be completed in 2 h whilst the results of the mu-capture ELISA can be available in 24 h. Both tests are amenable to routine diagnostic use and have similar sensitivity. Indirect ELISA was found to be less sensitive and less specific, giving high assay values with several sera having undetectable M. pneumoniae CF antibody or CF antibody in low titre. Serum samples obtained from 11 patients at various times after M. pneumoniae infection showed maximum antibody levels within the first month by all assays, with a gradual fall in amount of IgM with time when assayed by mu-capture ELISA, a more gradual decline by IFA and hardly any decline with indirect ELISA. It was concluded that the indirect ELISA is unsuitable for the investigation of possible M. pneumoniae infection because the sustained high assay values with serum samples taken many months after infection, make interpretation of the test results very difficult.

Antibodies, Bacterial↗

Detection of potentially allergenic hazelnut (Corylus avellana) residues in food: a comparative study with DNA PCR-ELISA and protein sandwich-ELISA.

Allergen detection is of increasing interest for food labeling purposes. A comparative study with a commercial hazelnut-specific PCR-ELISA and a sandwich-type ELISA detecting hazelnut protein was performed to investigate to what extent immunochemical and DNA-based techniques would correlate in the detection of trace amounts of potentially allergenic hazelnut residues. Both methods were highly sensitive and allowed the detection of even <10 ppm of hazelnut in complex food matrixes. The protein-ELISA was highly specific for hazelnut. However, some foods could lead to false-positive results at the 10 ppm level. The PCR-ELISA did not show any cross-reactions with non-hazelnut foods, thus reducing the probability of having false positives at the trace level. Forty-one commercial food products with and without hazelnut components on their labels were analyzed for the presence of hazelnut. Of the 27 products in which hazelnut components were detected, two samples were not identified by the protein-ELISA, and only one sample, namely one white chocolate having <1 ppm of hazelnut protein, was not detected by PCR-ELISA. The good correlation of the results of PCR-ELISA and protein-ELISA suggested that both PCR-based and immunochemical techniques are suitable for reliable detection of potentially allergenic hazelnut residues in foods at the trace level.

Allergens↗

Indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays (ELISAs) and IgM capture ELISA for detection of antibodies to lipopolysaccharide in adult typhoid fever patients in Pakistan.

Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population.

Adolescent↗

Comparison of competitive ELISA, indirect ELISA and standard AGID tests for detecting blue-tongue virus antibodies in cattle and sheep.

The performances of a competitive enzyme-linked immunosorbent assay (ELISA) using a group specific monoclonal antibody against bluetongue virus, an indirect ELISA and the standard agar gel immunodiffusion (AGID) test were compared in the detection of serum antibody against bluetongue virus. Test sera consisted of 1300 bovine, 530 ovine and 160 carpine samples from bluetongue-free areas of Canada, 605 bovine and ovine field samples from the USA and Barbados and 464 samples from 79 cattle and sheep experimentally infected with 19 South African and five USA serotypes of bluetongue virus. The diagnostic specificity of the competitive ELISA, as determined for the bluetongue virus-free cattle sera was superior (99.92 per cent) to that of the indirect ELISA (99.85 per cent) and the AGID (99.0 per cent). The specificities of the competitive ELISA for sheep (99.63 per cent) and goats (100.0 per cent) sera were also higher than those of the AGID test. The performance of the ELISA tests was similar whether a gamma-ray-irradiated (2.0 Mrad) or a non-irradiated bluetongue virus antigen preparation was used. The competitive ELISA results for bovine field sera from endemic areas demonstrated a relatively low level of agreement (92.04 per cent) with AGID test results, with 9.7 per cent false negatives. The possible presence in these sera of antibody to cross-reacting antigens or to other orbiviruses, eg, epizootic haemorrhagic disease virus, which react in the AGID but not in the competitive ELISA may account for this lack of agreement.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

R-ELISA: repeated use of antigen-coated plates for ELISA and its application for testing of antibodies to HIV and other pathogens.

In this paper we report on the evaluation of several procedures that allow for the repeated use of an antigen-coated, enzyme-linked immunosorbent assay (ELISA) plate for enzyme immunoassay (EIA). We have shown that antigen-coated ELISA plates that were incubated once with an aqueous solution containing 8 M urea, 2% sodium dodecyl sulfate and 2% mercaptoethanol, after an EIA, can be reused again for EIA without loss of antigenic capacity. Thus, in this procedure, after an EIA, the ELISA plates were washed once with the above solution and then in a buffer containing 20 mM Tris-HCl, pH 7.5, 0.1% Tween 20 and 500 mM NaCl. This washing protocol was shown to remove the primary antibody, enzyme-conjugated secondary antibody and substrate without removing the antigen from the ELISA plate microwells. Thus, an antigen-coated ELISA plate previously used for an assay could be reused. We tested this repeat ELISA (R-ELISA) procedure on high antigen-binding ELISA plates coated with two different plant virus proteins, a synthetic peptide, the p25/24 gag and the gp120 proteins of the human immuno-deficiency virus, or the staphylococcus enterotoxin protein. In each case tested, the procedure allowed for the repeated use of the same antigen-coated plates for EIA of the respective antibodies. This procedure should prove to be particularly valuable for mass screening of samples tested for HIV and other disease-causing agents.

Amino Acid Sequence↗

Evaluation of ELISA and GM1-ELISA for detection of Salmonella enterotoxin.

The ELISA and GM1-ELISA, by using antiserum to purified Salmonella enterotoxin (SE), were standardized and carried out to screen salmonellae isolated from foods of animal origin for enterotoxigenicity. Of the 101 strains of Salmonella belonging to 15 different serogroups tested, 76 (75.24%) strains from 13 serogroups were found enterotoxigenic. ELISA correlated well with rabbit ligated ileal loop (RLIL) test for the detection of enterotoxin producing salmonellae with 24 test strains. ELISA also yielded positive reaction with 7 of 13 RLIL negative strains. GM1-ELISA could not be carried out as none of the 101 cell free culture supernatants (CFCS) were able to bind with GM1-ganglioside. ELISA and GM1-ELISA were also standardized with antiserum to cholera toxin for the detection of salmonellae producing cholera related enterotoxin. None of the 101 strains was found to produce cholera related enterotoxin. ELISA could detect as low as 15 ng/100 microliters of purified SE and 10 ng/100 microliters of cholera toxin when tested with their homologous antisera.

Cholera Toxin↗

Enzyme-linked immunosorbent assay (ELISA) with bacterial sonicate antigen for IgM, IgA, and IgG antibodies to Francisella tularensis: comparison with bacterial agglutination test and ELISA with lipopolysaccharide antigen.

An enzyme-linked immunosorbent assay (ELISA) with bacterial sonicate (S) as antigen developed for determining the presence of IgM, IgA, and IgG antibodies to Francisella tularensis was compared with the bacterial agglutination (BA) test and a corresponding ELISA using lipopolysaccharide (LPS) antigen. Of the organisms tested, F tularensis was the only one to cause significant inhibition, indicating the specificity of the S-ELISA. BA test titers correlated significantly with antibody levels in all three immunoglobulin classes and most closely with IgM antibodies (r = 0.83). With some minor exceptions, the S-ELISA and the LPS-ELISA gave identical results, and the correlations between the tests were very close (r = 0.94-0.99). The S-ELISA confirmed the tularemia diagnosis with the first serum specimens from 43% of patients with tularemia vs 17% of the BA test. In addition, no seroconversion was observed by the BA test in 4% of the patients, although large increases were observed in S-ELISA titers.

Adolescent↗

[Diagnosis of HCV infection by 3rd-generation ELISA in HCV-RNA positive hypertransaminasemic patients with 2nd-generation ELISA negative results].

To evaluate the improved sensitivity of 3rd-generation assays for the detection of ani-HCV antibodies in diagnosing cases of HCV infection, we have re-tested by 3rd-generation ELISA test (ELISA-3) serum samples from immunocompetent patients with chronic hypertransaminasemia who were HCV-RNA positive but tested negative with 2nd-generation ELISA (ELISA-2). Out of 21 HCV-RNA positive/ELISA-2 negative samples, 3 (14.3%) were ELISA-3 positive. Among the ELISA-3 reactive samples, two were indeterminate by RIBA-3 (one was reactive with c1 00 and the other with c22), and one was negative. These results demonstrate that even in the clinical setting ELISA-3 improves the diagnosis of HCV infection. The improvement seems to be related to a better reactivity of HCV peptides rather than to the inclusion of the new determinant NS5. However, the sensitivity of the tests for the detection of anti-HCV antibodies remains to be improved.

English Abstract↗

Diagnostic values of ELISA-IgG4 as compared to ELISA-IgG and indirect immunofluorescence, for the routine diagnosis of bancroftian filariasis in the South Pacific. Application on capillary blood collected on filter paper.

For the serodiagnosis of lymphatic filariasis, serological assays restricted to the detection of specific IgG4 antibodies enhanced the specificity. In French Polynesia, Wuchereria bancrofti is the sole human filaria and other pathogenic parasites are infrequent. In order to define a simple and cheap serological test, we have compared the diagnostic value of indirect immunofluorescence test (IFI-WBp), ELISA-IgG and ELISA-IgG4 assays. The specificity, sensitivity, R.O.C. curves of each test have been analyzed. No significant difference was found between those 3 tests, except that the reproducibility and the predictive value were lower using IFI-WBp than using the two ELISAs. Significant correlation was found between IgG and IgG4 anti-Brugia malayi antibody titers (r = 0.512, p less than 10(-5)). For large scale seropidemiological studies, ELISA-IgG can be performed with finger prick blood absorbed on filter paper, but not ELISA-IgG4. In conclusion, ELISA-IgG a less expensive and less time consuming method than ELISA-IgG4, can be used for the routine serodiagnosis as well as for seroepidemiological studies on bancroftian filariasis in the South Pacific islands.

Animals↗

The association of "standard ELISA" and HIV (env) ELISA for detection and confirmation of HIV antibodies in human sera.

Sera from various population of subjects, including patients with AIDS and ARC, drug-addicts seropositive for HIV and healthy blood donors were screened with "standard ELISA" and HIV (env) ELISA. In the present study all 80 specimens from patients with AIDS and all 60 patients with ARC were positive by HIV (env) ELISA, and 1507 specimens from HIV drug positive by W.B. were detected as positive by HIV (env) ELISA. The specificity of HIV (env) ELISA was defined in terms of percentage of non-reacting persons in a low risk population is 100%. Furthermore the HIV (env) ELISA is highly specific and sensitive and could be used in association with "standard ELISA" for detection and confirmation of HIV antibodies in human sera and plasma.

AIDS Serodiagnosis↗

Comparison of Dot-ELISA with Sandwich ELISA in detecting circulating antigen in patients with bancroftian filariasis.

Dot-ELISA assay was compared with standard Sandwich ELISA in detecting parasite antigen in sera from patients with bancroftian filariasis. The same monoclonal antibody and the same serum samples were used in both assays. With Dot-ELISA, 67 of 70 serum samples from microfilaremic patients were positive at a dilution of 1:50. End titers ranged from 1:80 to 1:1 280. While with Sandwich ELISA, 64 of the 70 serum samples were positive at a dilution of 1:10. End titers ranged from 1:10 to 1:320. The specificity of both assays was over 91%, but their sensitivity was markedly different. Dot-ELISA could detect as little as 0.055 ng/ml microfilarial antigen added to normal human serum, whereas the lower limit of detection by Sandwich-ELISA was 10 ng/ml parasite antigen. An additional advantage of Dot-ELISA is that it does not require radioactivity or sophisticated equipment and, therefore, can be performed in virtually all filariasis-endemic areas.

Animals↗

Comparison of Dot-ELISA with Sandwich-ELISA for the detection of circulating antigens in patients with bancroftian filariasis.

We compared the performance of a newly developed Dot-ELISA with that of a previously described Sandwich-ELISA to detect parasite antigens in sera from patients with bancroftian filariasis. The same monoclonal antibody and the same sera were used in both tests. In the Dot-ELISA, 67 of 70 sera from microfilaremic donors were deemed to contain filarial antigens when screened at a dilution of 1:50. End titers were 1:80-1:1280. With the Sandwich-ELISA, 64 of the same sera were positive at a dilution of 1:10 and 42 were positive at a dilution of 1:50. End titers were 1:10-1:320. The specificity of both assays was greater than 95%, but their sensitivity was remarkably different. The Dot-ELISA could detect as little as 0.055 ng/ml microfilarial antigen added to normal human sera, whereas the lower limit with the Sandwich-ELISA was 10 ng/ml parasite antigen. Additionally, the Dot-ELISA does not require radioactivity or sophisticated equipment and, therefore, can be performed in virtually all filariasis-endemic areas.

Animals↗