Search PubMedSearch

SEARCH · Search PubMed

Results for “Device Approval”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

123 records · Page 2Linked to original sources

Postoperative Curvature Loss in Three-Level Anterior Cervical Discectomy and Fusion With Zero-Profile Device.

PURPOSE: Cervical curvature loss is a frequent complication following 3-level anterior cervical discectomy and fusion (ACDF) using a Zero-Profile device. Consequently, the capacity of this device to maintain cervical sagittal alignment in 3-level ACDF remains highly controversial. This study aimed to identify potential predictors for postoperative curvature loss (PCL) and evaluate its impact on clinical outcomes. METHODS: A total of 113 patients who underwent ACDF for 3-level cervical degenerative disc disease (CDDD) between January 2021 and December 2023 were retrospectively reviewed. Demographic data, radiological parameters, and clinical outcomes were analyzed. Radiographic measures included cervical curvature, T1 slope, C2-7 sagittal vertical axis, and titanium plate and endplate (TPE) distance. Clinical outcomes were assessed using the Visual Analog Scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) scores. Statistical analyses were performed using paired and independent t-tests, as well as Pearson correlation coefficients. RESULTS: The average curvature loss was 6.82&#xb0; from 1&#x2009;week postoperatively to the final follow-up (p&#x2009;<&#x2009;0.001). However, the final curvature (11.65&#xb0;) was maintained, representing a 4.33&#xb0; improvement compared to preoperative values. Significant correlations were observed between PCL and preoperative curvature (r&#x2009;=&#x2009;-0.368, p&#x2009;=&#x2009;0.013), preoperative T1 slope (r&#x2009;=&#x2009;-0.546, p&#x2009;<&#x2009;0.001), &#x2206;T1 slope (r&#x2009;=&#x2009;0.443, p&#x2009;=&#x2009;0.002), and &#x2206;TPE distance (r&#x2009;=&#x2009;0.417, p&#x2009;=&#x2009;0.004). PCL did not correlate with Japanese Orthopaedic Association (JOA) scores or arm VAS scores at the final follow-up. Nevertheless, patients with a PCL&#x2009;&#x2265;&#x2009;6&#xb0; exhibited significantly higher neck VAS (p&#x2009;=&#x2009;0.028) and NDI scores (p&#x2009;=&#x2009;0.041). CONCLUSION: Although contiguous 3-level ACDF with a Zero-Profile device may result in PCL, it preserves an improved cervical lordosis compared to the preoperative baseline. Low preoperative curvature and a low preoperative T1 slope are potentially predictive factors for PCL. Postoperative changes in TPE distance and T1 slope are significantly associated with PCL, suggesting a potential biomechanical link that requires direct validation. Furthermore, PCL may lead to higher neck VAS and NDI scores. Consequently, the Zero-Profile device may require careful consideration in 3-level CDDD patients presenting with low preoperative curvature and a low T1 slope. Importantly, the 6&#xb0; PCL threshold identified is preliminary and requires prospective validation before clinical application.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

Hand Pain and Sensory Deficits: Carpal Tunnel Syndrome: 2026 Revision. Using the Evidence to Guide Musculoskeletal Rehabilitation Practice.

SYNOPSIS: Carpal tunnel syndrome is common in women, manual laborers, and during pregnancy; it is often associated with medical conditions such as obesity and diabetes. The musculoskeletal rehabilitation clinician's approach to managing hand pain and sensory deficits associated with carpal tunnel syndrome should include prescribing a neutral-positioned wrist orthosis plus instructing the patient on how to modify activities, adjust ergonomics, and reduce exposure to risk factors. Here, we present for clinicians the most up-to-date information to guide their work in managing hand pain and sensory deficits associated with carpal tunnel syndrome. J Orthop Sports Phys Ther 2026;56(9):622-623. doi:10.2519/jospt.2026.0502.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift&#x2122;), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3&#x202f;&#xb1;&#x202f;13.2 years; mean AHI 22.9&#x202f;&#xb1;&#x202f;13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Efficacy of targeted neuromodulation treatments: a clinical report.

BACKGROUND: Peripheral neuropathy is a debilitating condition characterized by chronic pain, numbness, tingling, burning, and tightness/swelling. Conventional therapies often focus on symptom management, and some patients experience chronic and refractory symptoms. RESEARCH DESIGN AND METHODS: This retrospective clinical analysis evaluated the clinical outcomes of neuromodulation neuropathy treatment using the NeuroGen-Series device in patients with diabetic peripheral neuropathy (DPN) or idiopathic peripheral neuropathy (IPN). 9,805 unique patients who underwent 133,741 treatments between 18 August 2017, and 23 July 2024, were analyzed. Patients were divided into treatment completers (&#x2265;24 sessions) and noncompleters (<24 sessions). Paired t-tests confirmed statistically significant reductions in pre- and post-treatment symptom scores (p&#x2009;<&#x2009;0.001). RESULTS: Among completers, symptom severity decreased by an average of 46.2%. Tingling and pain showed the greatest improvement, while tightness/swelling and numbness showed the least reduction. 64% of patients reported improvement after one session, and 84% reported improvement after 24 sessions. Nonresponders accounted for 5.8% of patients overall. Younger patients and those with higher initial symptom severity were more likely to discontinue treatment. CONCLUSIONS: Overall, neuromodulation treatment resulted in statistically significant reductions in symptom severity, though nonresponders and high attrition rate highlight the need for individualized treatment strategies and further investigation.

Humans

Initial 4-Year Experience With Microaxial Flow Pumps Within a Tertiary Centre in Regional Australia.

BACKGROUND & AIM: The Microaxial Flow Pump (MFP) is a miniaturised rotary pump that aspirates blood from the left ventricle and expels it into the ascending aorta. It unloads the left ventricle and increases mean arterial pressure and cardiac output. MFP is most commonly utilised in cardiogenic shock, for protected percutaneous coronary intervention (PCI), and for ventricular offloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO). METHOD: We conducted a retrospective review of all patients who underwent MFP insertion at John Hunter Hospital, Australia. Categorical data are represented as counts and percentages, with continuous variables described as means with standard deviations. RESULTS: Twenty-three MFP devices were inserted between September 2020 and May 2024. Five (22%) were for protected PCI, three (13%) for venting with VA-ECMO (ECPELLA), and 15 (65%) for acute coronary syndrome (ACS) and cardiogenic shock. The median age for the overall cohort was 62 years, with a 74% male predominance. Eighty percent of the protected PCI cohort were elective outpatient procedures, and there were no deaths in this cohort. The mortality in the ECPELLA group was 67%. Thirteen (87%) of the patients with cardiogenic shock presented with an anterior infarct, and 53% had cardiac arrest on admission. The overall morality in the cardiogenic shock cohort was 40%. Complications in this cohort included limb ischaemia in four patients (17%) and site bleeding in seven patients (30%). Four patients (17%) required vascular surgery intervention. CONCLUSION: Our initial experience showed the use of MFP in a tertiary centre was safe and feasible, allowing progression from protected percutaneous intervention to acute cardiogenic shock.

Humans

New Horizons in the Development of Treatments for Substance Use Disorders.

Substance use disorders (SUDs) are a major public health problem in the United States and cause substantial morbidity and mortality. There are meaningful gaps in the available SUD treatment options, and the development of new therapies is urgently needed. While medications with U.S. Food and Drug Administration approval are available for alcohol, nicotine, and opioid use disorders, there are no approved pharmacotherapies for cannabis, cocaine, or methamphetamine use disorders. Behavioral treatments for SUDs have significant limitations in effectiveness and accessibility, and there is a need for the development of both new behavioral treatment options and new models of treatment delivery. The next generation of treatments for SUDs will likely come from a diverse set of interventions, including new drug classes, new technologies, and new methods of delivery.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Effects of Vacuum Compression Therapy on Healing of Chronic Lower Limb Ulcers: A Randomised Controlled Study.

Chronic lower limb ulcers remain difficult to manage when unresponsive to conventional treatment. This study evaluated the clinical and physiological effects of vacuum compression therapy on wound healing and quality of life. Fifty patients with chronic lower limb ulcers were randomised to receive 12 sessions of vacuum compression therapy plus standard care or standard care alone over 4&#x2009;weeks. Wound dimensions, exudate, pain intensity and quality of life were assessed at baseline and post-treatment. Estimated wound volume was calculated as length&#x2009;&#xd7;&#x2009;width&#x2009;&#xd7;&#x2009;depth. Tissue oxygenation was measured at the dorsum of the foot in the experimental group. The vacuum compression therapy group showed greater improvements in wound width, depth, volume and quality of life. Estimated wound volume decreased by 61% in the intervention group, whereas no statistically significant volume reduction was observed in controls. Local tissue oxygenation in the experimental group increased by 43%. Baseline wound size was associated with poorer quality of life. Vacuum compression therapy may enhance wound healing and quality of life in patients with chronic lower limb ulcers. Observed increases in local tissue oxygenation represent exploratory physiological findings within the treated cohort that warrant controlled comparative evaluation. Trial Registration: ClinicalTrials.gov identifier: NCT07737184.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans

Effects of an actuated ankle exoskeleton on walking stability in healthy adults: a controlled laboratory study.

BACKGROUND: Ankle exoskeletons are widely used to reduce the metabolic cost of walking, yet their effects on walking stability during unperturbed gait remain insufficiently understood. Walking stability can be characterized using complementary measures that capture stride-to-stride variability, global temporal organization, and local dynamic stability. Understanding how walking with an actuated ankle exoskeleton system influences these different aspects of gait stability is essential for the safe design and control of wearable robotic devices. METHODS: Eighteen healthy adults walked on a treadmill at a constant speed (1.1&#xa0;m/s) with and without an actuated bilateral ankle exoskeleton in a randomized crossover design. Spatiotemporal variability was quantified using coefficients of variation (CoV) of stride length, step width, and stance ratio. Global gait stability was assessed using detrended fluctuation analysis of stride time. Local dynamic stability was evaluated using maximum Lyapunov exponent calculated for the trunk, hip, upper leg, lower leg, and foot. Paired-samples two-sided t-tests were used to compare conditions. RESULTS: Walking with the ankle exoskeleton resulted in increased stride-to-stride spatiotemporal variability, reflected by higher CoV values for stride length (p&#x2009;<&#x2009;0.001) and stance ratio (p&#x2009;=&#x2009;0.005), while mean stride length and step width remained unchanged. Mean stance ratio was reduced in the exoskeleton condition (p&#x2009;<&#x2009;0.001). Global gait stability did not differ between conditions, indicating preserved long-range temporal gait organization. Local dynamic stability increased at the lower leg (p&#x2009;<&#x2009;0.001) and foot (p&#x2009;=&#x2009;0.019) when walking with the exoskeleton. CONCLUSIONS: Walking with the actuated ankle exoskeleton alters gait control across multiple levels during steady walking. While stride-to-stride variability in stride length and stance ratio increased, global gait stability remained unchanged. Local dynamic stability was increased at the lower leg and foot, suggesting segment-specific effects of ankle-level assistance close to the assisted joint. However, these findings should be interpreted as the combined effect of wearing the exoskeleton and receiving active assistance, rather than the isolated effect of plantarflexion assistance. These&#xa0;results provide insight for the design and control of ankle exoskeletons with respect to stability-related effects during walking.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans