Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capillary Electrochromatography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography.

Capillary columns with monolithic stationary phase were prepared from silanized fused-silica capillaries of 75 microns I.D. by in situ copolymerization of divinylbenzene either with styrene or vinylbenzyl chloride in the presence of a suitable porogen. The porous monolithic support in this study was used either directly or upon functionalization of the surface to obtain a stationary phase that was appropriate for the separation of peptides by capillary electrochromatography (CEC). The main advantages of monolithic columns are as follows. They do not need retaining frits, they do not have charged particles that can get dislodged in high electric field, and they have relatively high permeability and stability. Whereas such columns are designed especially for CEC, they find application in micro high-performance liquid chromatography (mu-HPLC) as well. Five different porogens were employed to prepare the monolithic columns that were examined for permeability and porosity. The flexibility of fused-silica capillaries was not adversely affected by the monolithic packing and the longevity of the columns was satisfactory. This may also be due to the polymerization technique, which resulted in a fluid-impervious outer layer of the monolith that precluded contact between the fused-silica surface and the liquid mobile phase. For the most promising columns, the conductivity ratios and the parameters of the simplified van Deemter equation, both in mu-HPLC and CEC, were evaluated. It was found that the efficiency of the monolithic columns in CEC was significantly higher than in mu-HPLC in the same way as observed with capillary columns having conventional particulate packing. This is attributed to the relaxation of band-broadening with electroosmotic flow (EOF) with respect to that with viscous flow. It follows then that the requirement of high packing uniformity to obtain high efficiency may also be relaxed in CEC. Angiotensin-type peptides were separated by CEC with columns packed with a monolithic stationary phase having fixed n-octyl chains and quaternary ammonium groups at the surface. Plate heights of about 8 microns were routinely obtained. The mechanism of the separation is based on the interplay between EOF, chromatographic retention and electrophoretic migration of the positively charged peptides. The results of the complex migration process, with highly nonlinear dependence of the migration times on the organic modifier and the salt concentration, cannot be interpreted within the framework of classical chromatography or electrophoresis.

Amino Acid Sequence↗

Application of hydrophobic anion-exchange phases in capillary electrochromatography.

Capillary electrochromatography (CEC) requires stationary phases that enable appropriate electroosmotic propel under various conditions. Analyte retention can be controlled through hydrophobic or electrostatic interaction with the packing material. The development and characterization of new strong anion-exchange materials with additional hydrophobic moieties (SAX/C18 mixed-mode phases) is described. The synthesis was based on polymer encapsulation of porous silica. The phases were systematically characterized by means of elemental analyses, HPLC frontal analyses and CEC experiments. The studies focused on the influence of various parameters (e.g., pH, kind of buffer, capillary wall) on the electroosmotic flow (EOF). Phases with high anion-exchange capacity generated a fast and constant EOF over a wide pH range. Long-time stability of EOF and hydrophobic retention under CEC conditions were demonstrated within the course of 100 consecutive injections. The applicability of the SAX/C18 phases in appropriate buffer systems is demonstrated for neutral, acidic and basic compounds.

Anion Exchange Resins↗

A drying step in the protocol to pack capillary columns by centripetal forces for capillary electrochromatography.

Capillary columns have been packed for capillary electrochromatography (CEC) using centripetal forces. The packed columns were maintained under wet conditions or they were dried with nitrogen gas prior to forming the retaining frits. Upon fabrication of the retaining frits, the dried columns were resolvated with the mobile phase. The performance of the columns was evaluated to determine the effect of the drying step during the packing procedure. The columns submitted to the drying step showed improved separation efficiencies and stronger retention characteristics than those kept under wet conditions. The drying step allows the silica-based packing material to be better accommodated inside the capillary column. Upon solvation, the packing material "swells," resulting in a greater packing density, which allows for a stronger retention and improved separation efficiencies. The drying step led to a 13% increase in retention on columns packed with isopropanol. An increase of 15-20% in theoretical plates for the most retained compounds was also observed in such columns.

2-Propanol↗

Splitless on-line coupling of capillary high-performance liquid chromatography, capillary electrochromatography and pressurized capillary electrochromatography with nuclear magnetic resonance spectroscopy.

A mixture of unsaturated fatty acid methyl esters was separated with a new splitless capillary set-up. With the employed apparatus configuration different capillary separation techniques such as capillary high-performance liquid chromatography (cHPLC), capillary electrochromatography (CEC) and pressurized capillary electrochromatography (pCEC) could be applied. The detection and identification of the sample compounds were accomplished by hyphenating these capillary separation techniques with nuclear magnetic resonance (NMR) spectroscopy using a novel configuration of the detection capillary set-up. Using modified electrokinetically driven separation techniques, the electric field was applied solely across the separation column. With this improved interface for capillary liquid chromatography-NMR on-line coupling, the stereochemical assignment of the cis and trans configuration of unsaturated fatty acids could be easily accomplished. Finally, the results of cHPLC-NMR, CEC-NMR and pCEC-NMR coupling experiments were compared.

Journal Article↗

Recent progress in capillary electrochromatography.

Capillary electrochromatography (CEC) continues to captivate many separation scientists. A remarkable activity is apparent from the numerous publications in the literature using CEC. A review of the most recent progress in CEC is presented herein, covering an extensive fraction of the literature on CEC published from the year 1997 until the beginning of 2000. Most of the recent developments have concentrated on column technology.

Chromatography, High Pressure Liquid↗

Determination of trace isoflavone phytoestrogens in biological materials by capillary electrochromatography.

Capillary electrochromatography using a specialty monolithic matrix was utilized in developing a rapid and highly efficient separation of isoflavones in biological materials. Without a preconcentration technique, it is relatively easy to reach ppm-ppb concentrations of these compounds in soy-based foods and verify them structurally using a photodiode array detector. With on-column preconcentration, we were able to measure low-ppb levels in human serum. Using blood samples from human volunteers, whose diet was supplemented by a soy-based product, the method has been validated for high-throughput screening of isoflavones in clinical studies.

Chromatography, Micellar Electrokinetic Capillary↗

Physically adsorbed chiral stationary phase of avidin on monolithic silica column for capillary electrochromatography and capillary liquid chromatography.

The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.

Adsorption↗

Comparison of the miniaturised techniques capillary electrochromatography and capillary liquid chromatography for the chiral separation of chlorthalidone.

The aim of this study was to compare the miniaturised techniques, capillary electrochromatography (CEC) and capillary liquid chromatography (CLC), for the chiral separation of chlorthalidone. In both cases, hydroxypropyl-beta-cyclodextrin was used as a chiral selector in the mobile phase, while an achiral stationary phase was used. Earlier, this separation was already optimised in CEC. Now, the separation was optimised in CLC. The influence of the organic modifier content and the cyclodextrin concentration on the separation was studied by means of a central composite design. Optimal separation conditions were determined, after response modelling, from the response surface contour plots. When these conditions were compared with those of the CEC optimisation, we can see the potential of using CLC as a chiral separation technique since less chiral selector was used, faster separations were obtained and better repeatability was observed in comparison with its electrical-driven counterpart.

Chlorthalidone↗

Open tubular capillary electrochromatography using capillaries coated with films of alkanethiol-self-assembled gold nanoparticle layers.

We have used alkanethiol self-assembly and dithiol layer-by-layer (LBL) self-assembly processes to prepare an Au nanoparticle (NP)-coated open tubular capillary electrochromatography (OTCEC) column for the separation of three neutral steroid drugs (testosterone, progesterone, and testosterone propionate). The CEC column was fabricated through LBL self-assembly of Au NPs on a 3-aminopropyltrimethoxysilane (APTMS)-modified fused-silica capillary and subsequent surface functionalization of the Au NPs through self-assembly of alkanethiols. We investigated the electrochromatographic properties of the resulting Au NP-coated CEC column using a "reversed phase" test mixture of three steroid drugs. We found that the key factors affecting the separation performance were the number of Au NP layers, the length of the carbon-atom chain of the alkanethiol self-assembled on the Au NPs, the percentage of organic modifier, and the pH of the running electrolyte. This study reveals that the self-assembly of alkanethiols and dithiols onto Au NPs provides stationary phases for CEC separation that are easy to prepare and whose retention behavior is highly controllable and reproducible. We believe that our findings will contribute to further studies of the application of nanotechnology to separation science.

Acetonitriles↗

Semipreparative capillary electrochromatography.

Capillaries with inner diameters of 550 microm have successfully been packed with 1.5-microm octadecyl silica particles using frits made of macroporous polymers by the UV photopolymerization of a solution of glycidyl methacrylate and trimethylolpropane trimethacrylate. This type of frit is found superior to one made of low-melting point poly(styrene-co-divinylbenzene) beads. Bubble formation is not observed to occur within these capillary columns under our experimental conditions. Separations can be achieved with sample injection volumes as high as 1 microL. To demonstrate its semipreparative use, a mixture of 500 nL of taxol (20 mM) and its precursor, baccatin III (30 mM), is separated using such a column with a Tris buffer.

Alkaloids↗

Comparison of separation behavior of benzodiazepines in packed capillary electrochromatography and open-tubular capillary electrochromatography.

Packed column capillary electrochromatography (CEC), open-tubular CEC and microcolum liquid chromatography (LC) using a cholesteryl silica bonded phase have been studied to compare the retention behavior for benzodiazepines. It has been found that packed column CEC gives better resolution, faster analysis time than microcolumn LC for benzodiazepines maintaining similar selectivity except for some solutes which are charged species under the separation conditions. However, open-tubular CEC gave different selectivities to a larger extent for charged benzodiazepines from that which should be produced by the chromatographic properties of the cholesteryl silica phase. Charged species migration times are mainly influenced by electrophoretic mobility rather than the chromatographic interactions.

Benzodiazepines↗

Open-tubular capillary electrochromatography using capillary columns chemically bonded with the new host molecules calix[6]crown, calix[6]arene.

Two host molecules, p-tert-butylcalix[6]-1,4-crown-4 and p-tert-butylcalix[6]arene were prepared and attached onto the inner surfaces of capillaries for open-tubular electrochromatography with the aid of gamma-glycidoxypropyl-trimethoxysilane (KH-560) as bridging agent. The successful bonding was confirmed by infrared (IR) results and greatly decreased electroosmotic flow (EOF). Parameters affecting separation, such as buffer pH and organic modifier were studied. The two novel stationary phases were evaluated by the separation of isomeric toluidines, a mixture of pyridine and isomeric picolines, and isomeric dihydroxybenzenes; comparisons between capillaries coated with the two stationary phases and bare capillary were investigated. The special selectivity of these two novel stationary phases showed a certain extent of supramolecular interactions between stationary phases and solutes.

Calixarenes↗

Preparation and evaluation of a molecularly imprinted polymer derivatized silica monolithic column for capillary electrochromatography and capillary liquid chromatography.

A method for preparation of molecularly imprinted polymer (MIP) derivatized onto the surface of a monolithic silica capillary column was successfully developed. The vinyl groups were first introduced onto the silica monolith by immobilization of gamma-methacryloxypropyltrimethoxysilane. Then the MIP coating was copolymerized and anchored onto the surface of the silica monolith. Acetonitrile was selected as porogen (solvent). The other preparation conditions, such as monomer concentration, temperature, and time of polymerization, were systematically studied. The obtained MIP-derivatized silica monolith using l-tetrahydropalmatine (l-THP) and (5S,11S)-(-)-Tröger's base (S-TB) as the imprinted template, respectively, was characterized in terms of the retention behavior of thiourea and toluene. Under the optimized CEC conditions, baseline enantioseparations of THP and TB were achieved in 4 min though the effective length of the columns was 8.5 cm. The result indicates that enough recognition sites were on the surface of silica monolith, resulting in strong recognition ability. Compared with a MIP organic monolith, the MIP-derivatized silica monolith exhibits better column efficiency and stability in CEC. Additionally, the comparison of these two kinds of monolithic columns was performed by capillary liquid chromatography. The separation on MIP-derivatized silica monolith was superior to that on the organic monolith.

Journal Article↗

Effect of various modes of pressurization on the separation in capillary electrochromatography.

In capillary electrophoresis and capillary electrochromatography, the driving factor of the separation is electroosmotic flow (EOF). Pressurized capillary electrochromatography, in which the separation is controlled by EOF as well as the pressure, becomes more and more attractive. We studied the influence of various pressures on capillary electrochromatographic separation. The results reveal that in pressurized capillary electrochromatography, which was performed by EOF combined with the forward and reverse pressure, the main driving factor is still the EOF. It was also found that, when reverse pressure was applied in capillary electrochromatography, the repeatability of the capillary electrochromatographic separation was increased dramatically.

Chromatography, Micellar Electrokinetic Capillary↗

Visible diode laser induced fluorescence detection of doxorubicin in plasma using pressurized capillary electrochromatography.

Pressurized capillary electrochromatography is a variant of capillary electrochromatography (CEC) in which the driving force is both electroosmotic and hydraulic. The inlet of the CEC capillary is pressurized using an HPLC pump, and an electric field is simultaneously applied. This work describes a method for the analysis of doxorubicin. Doxorubicin was reacted with Cy5.29.OSu in acetonitrile. The derivative was confirmed by RP-TLC. A CEC system equipped with a VDLIF detector was constructed and used to analyze the derivative. The reaction mixture was injected onto a capillary packed in-house with 3 microm C-18 Luna particles and separation was carried out at 25 kV using 70% acetonitrile/ 30% phosphate (10 mM, pH = 4.8) as the mobile phase. The derivatization reaction was optimized by the investigation of parameters such as reaction time, temperature and concentration of label in order to increase the yield of the derivative. The optimal conditions were determined to be 30 min, 80 degrees C and 50 nmol/mL, respectively. Doxorubicin was extracted from plasma using solid-phase extraction under alkaline conditions, derivatized and injected onto the CEC-VDLIF system. The selectivity of the assay was demonstrated by a lack of interfering peaks due to plasma constituents across the elution window of the derivative peak in blank plasma extracts (n = 6 sources). The limit of detection (LOD) of the assay in plasma calculated as 3 s(b)/m was determined to be 1.7 ng/mL. The precision of the assay determined at a concentration of 167.7 ng/mL (n = 5) was found to be within 7.04 %RSD.

Antibiotics, Antineoplastic↗

Enantiomeric separation by capillary electrochromatography using monolithic capillaries with sol-gel-glued cyclodextrin-modified silica particles.

By an on-column sol-gel process, a chiral monolithic stationary phase was prepared by the fusion of permethyl-beta-cyclodextrin-silica (Chira-Dex-silica) particles and by linking them to the internal capillary wall. The resulting monolith is stable toward voltage (30 kV) and pressure (300 bar) and possesses a high efficiency (up to 100,000 theoretical plates per meter). Efficient enantiomeric separation of various chiral compounds by pressure-supported capillary electrochromatography (CEC) was achieved. When comparing this method to capillary liquid chromatography (LC) employing the same column in an unified equipment, CEC shows a twofold higher column efficiency at comparable elution times and hence better resolution factors.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary electrochromatography with segmented capillaries for controlling electroosmotic flow.

Capillaries consisting of two segments each packed with a different stationary phase were introduced for the control and manipulation of the electroosmotic flow (EOF) in capillary electrochromatography (CEC). This kind of column configuration was called segmented capillary where one segment was packed with octadecyl silica (ODS) and served as the separation segment while the other segment was packed with bare silica and functioned as the EOF accelerator segment. The average flow in the segmented capillary increased linearly with increasing fractional length of the EOF accelerator segment, and consequently the analysis time was reduced. Under a given set of conditions, the average flow can be varied over a certain range that extends from the EOF in the individual ODS capillary at the lower end to the EOF in the individual bare silica capillary at the higher end. The pore size of the bare silica in the EOF accelerator segment influenced the average flow in the segmented capillary. Because of the difference in the EOF of the individual segments, the average flow across the segmented capillary is partially degenerated from EOF to viscous flow. Furthermore, the retaining frits in CEC columns are restrictive points which slow down the average flow, thus furthering the degeneration of the flow from EOF to viscous flow. In other words, in CEC columns containing retaining frits, the flow of the mobile phase is not only based on electroosmosis but is contaminated by a viscous component.

Chromatography, Liquid↗

Separation and identification of etodolac and its urinary phase I metabolites using capillary electrochromatography and on-line capillary electrochromatography-electrospray ionisation mass spectrometry coupling.

Capillary high-performance liquid chromatography (capillary HPLC), pressure-assisted capillary electrochromatography (pCEC) and capillary electrochromatography (CEC) were performed in the same capillary packed with 5 microm octadecylsilica (C18) as stationary phase. These three separation modes were compared from the viewpoint of peak efficiency and separation selectivity in order to critically evaluate the advantages which CEC may offer compared to capillary HPLC for the solution of practical biomedical problems. The separation of the non-steroidal anti-inflammatory drug etodolac (ET, 1) and its phase I metabolites, 6-hydroxy etodolac (6-OH-ET, 2), 7-hydroxy etodolac (7-OH-ET, 3) and 8-(1'-hydroxyethyl) etodolac (8-OH-ET, 4) was selected as an example. Baseline separation of all compounds was achieved in different modes and conditions. The effect of pure electrophoretic separation mechanism on the overall separation selectivity observed in CEC has been shown. A high electroosmotic flow (EOF) was observed in C18 packed capillary even at pH 2.5 in various buffers. Furthermore, these separations were coupled on-line with electrospray ionisation mass spectrometry (ESI-MS) and the parent drug and its metabolites were identified in urine. For the coupling of CEC with ESI-MS a laboratory-made electrophoretic device was used in order to overcome some technical disadvantages of commercial instrumentation.

Anti-Inflammatory Agents, Non-Steroidal↗