Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE RAYS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Raster-scan cathode-ray tubes for vision research--limits of resolution in space, time and intensity, and some solutions.

Raster-based cathode-ray tubes (CRTs) are increasingly used for stimulus presentation. While very flexible, their design based on consumer electronics can limit their value in vision research. Here their limitations of resolution in time, space, intensity and wavelength are systematically compiled. Often, ingenious ideas can circumvent such limitations for specific experiments. Some ad-hoc solutions, as well as the more general techniques of dithering and anti-aliasing, are presented.

Artifacts↗

Cathode ray tube glass recycling: an example of clean technology.

In this study the use of 'cleaned' end of life (EOL) cathode ray tube (CRT) glass as a raw material in ceramic glazes is described. At present, the recycling and industrial utilization of CRT, a glass material from TV and computer sets, is a subject of intense research with particular regard to the so-called open-loop recycling, namely cycles different from that of the origin. However, the use of CRT glass as a secondary raw material is strictly related to the demand of high-quality raw material. The good preliminary results reached by introducing clean TV and PC monitor panel and cone glass into ceramic glaze formulations pushed research toward the setting-up of a base glaze that is exploitable for the production of pigmented, silk-screened and flame-hardened glazes (products used industrially for coating floor tiles). The aesthetic and chemical characterization of the tiles glazed by this product showed an extremely similar behaviour to originals that did not contain CRT glass. The good technical results achieved have been supported by the life cycle assessment analysis, which has demonstrated a reduction of the environmental impact of the CRT glass-containing ceramic glaze with respect to the standard one.

Beta Particles↗

Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

Calibration↗

Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

The purpose of the study was to compare the detection performance of a cathode ray tube (CRT) monitor versus a liquid crystal display (LCD) monitor for simulated subtle pulmonary lesions. Ten templates containing simulated lung lesions were superimposed on an anthropomorphic chest phantom. Posteroanterior radiographs were obtained using flat panel technology and were displayed on a CRT and an LCD monitor. Image processing and reading conditions were equivalent for both softcopy displays. Five observers assessed lesion detectability using receiver-operating characteristic (ROC) methodology. A multivariate test (Pillai trace) was used to test the significance of differences (P<0.05). The multivariate test revealed significantly different detection rates for the lesion types, but no significant difference between the two display modes. Detection performance for both monitors was higher for nodules and micro-nodules and lower for lines and patchy opacities. Analysis of lesion subgroups according to their location in lucent/obscured lung areas was also not statistically significant. Under ideal reading conditions, CRT and LCD displays perform equivalently for the detection of simulated subtle pulmonary lesions.

Data Display↗

A note on luminance calibration of raster-scan cathode-ray tubes: temporal resolution, ripple, and accuracy.

Accurate luminance calibration is an important issue for stimuli in vision research. Raster-scan cathode-ray tubes present a rapidly scanning spot with a luminance of the order of 10,000 cd m-2 (the actual value depends on video timing and phosphor persistence). With little spatial integration this may result in overloading of the front stage of a photometer. More importantly, even if averaged over hundreds of milliseconds, the pulsed nature of the luminance signal will markedly reduce accuracy of the luminance measurement. A frame-synchronised photometer is described to increase measurement accuracy whilst still rapidly acquiring the result.

Computer Terminals↗

Comparison of readability between liquid crystal displays and cathode-ray tubes.

Flat-panel displays, especially liquid crystal displays (LCDs), are almost universally used today. Do LCDs assure better readability than cathode-ray tubes (CRTs)? Two experiments were carried out to determine which type of display is better using a newly developed device. Four types of displays were tested; negative and positive CRTs, and LCDs with and without backlighting. Variables were the type of display, age, and gender. At first, analyses of readability using eye movements were conducted. Middle-aged subjects showed slower reading speed than young subjects. Then, experiments of pupillo-accommodative functions were carried out. Non-backlit LCDs reduced focusing speed among young subjects and reading performance in middle-aged subjects. Since middle-aged workers have more difficulties than young workers, they should have their vision properly corrected for VDT viewing, more appropriate displays and a more comfortable illuminance environment than young workers.

Adolescent↗

Reaction time to accelerating lines and dots on a cathode-ray tube.

Two experiments recorded the simple RT of 13 and 10 airline pilots, respectively, to accelerating lines and dots on a cathode-ray tube. In Exp. 1, dotted lines of six lengths moved in-line or frontally, and downward or to the right. Exp. 2 compared seven different in-line-moving solid lines with dot pairs of corresponding separations, and with single dots. RT increased with the length of in-line-moving solid lines but not when dotted lines were used. RT decreased with frontal movement of dotted lines. RT to dot pairs was shorter than to solid lines or single dots. Results indicate the importance of three factors: amount of movement information, visual angle, and inhibition of the retinal area stimulated.

Humans↗

Influence of monitor luminance and room illumination on soft-copy reading evaluation with electronically generated contrast-detail phantom: comparison of cathode-ray tube monitor with liquid crystal display.

The influence of monitor brightness and room illumination on soft-copy diagnosis by both cathode-ray tube (CRT) monitor and liquid crystal display (LCD) was evaluated and compared using a contrast-detail phantom. Nine observers (7 radiologists and 2 radiological technicians) interpreted six types of electronically generated contrast-detail phantom images using a 21-inch CRT (2,048x2,560) and a 21-inch LCD (2,048x2,560) under 6 kinds of viewing conditions, i.e. monitor brightness of 330 cd/m2 or 450 cd/m2, and room illumination of 20, 100 or 420 lux at the center of the display. Observers were requested to determine the visible borderline of the objects. Between 330 cd/m2 and 450 cd/m2, no significant difference in the visible area was found under any of the three lighting conditions. However, in two low-contrast phantom images, the visible area on the LCD was significantly larger than that on the CRT, independent of both monitor brightness and room illumination. (p<0.05). The effect of room illumination was not significant, suggesting that the use of LCD at high room illumination is acceptable.

Computers↗

Luminance artifacts of cathode-ray tube displays for vision research.

Phosphor persistence, video bandwidth, DC restoration and high-voltage regulation affect the appearance of images presented on cathode-ray tubes (CRTs), potentially resulting in differences between nominal and actual stimuli. We illustrate these effects by measuring physical parameters of horizontal and vertical static and counter-phase flickering gratings, and we illustrate problems for vision research by measuring contrast sensitivity to these gratings. We also measured the extent to which calibration protocols actually result in the monitor being calibrated over its entire area regardless of image size. The results of our physical measurements indicate substantial differences between gratings that nominally differ only as to orientation. Consistent with these differences, our psychophysical measurements indicate different sensitivities when the bars of the gratings are parallel or orthogonal to raster lines, regardless of the retinal orientation of the gratings. The results of our calibration check show that only a small region around the target area of calibration can be regarded as effectively linearized, and only if the size of the test image used during the check is similar to the size of the calibration patch. Overall, our results indicate potentially severe problems with the use of CRTs in vision research, and we discuss some published results that are likely to have been affected by these problems.

Artifacts↗

Active matrix liquid crystal displays for clinical imaging: comparison with cathode ray tube displays.

Fifteen large-area, flat-panel displays used for clinical image review were evaluated for image quality and compared with 30 comparably sized cathode ray tube (CRT) monitors. Measurements were of image display patterns by Video Electronic Standards Association (VESA) and a commercial product. Field measurements were made of: maximum and minimum luminance, ambient lighting, characteristic curve (gamma), point shape and size, high-contrast resolution, uniformity, and distortion. Assessments were made of pixel defects, latent image patterns, ghosting artifacts, and viewing angle luminance. Also, a questionnaire was generated for users of the flat-panel and CRT units. Seventeen respondents indicated no preference for either flat panel or CRT. Results show these flat panels to have higher luminance (mean, 177.7 cd/m2); larger number of just noticeable differences (JNDs; n = 555), higher gamma, comparable uniformity, and warm-up time. CRTs had less angle viewing dependence and far fewer artifacts (ghosting and latent images). Our questionnaire showed active matrix liquid crystal displays (AMLCD) to be fully acceptable for clinical image viewing. Furthermore, the statistical results show that further testing for new AMLCDs of this type is unwarranted.

Computer Terminals↗

Diagnostic usefulness of chest computed radiography--film versus cathode-ray tube images.

Seventy-one plain chest images obtained by computed radiography (CR) with an imaging plate were interpreted on film and two kinds of cathode-ray tube (CRT) monitors installed separately at two facilities (1,024 x 1,536 pixels, 8 bits, and 1,024 x 1,280 pixels, 10 bits) by 20 radiologists and four chest internists. The clinical categories of these 71 cases included pulmonary nodules and interstitial abnormalities. Image reading sessions were held over a total of 4 days, ie, 2 days and then another 2 days, 3 weeks later. Twenty-four observers formed four groups with six members each. Two groups read either films or CRT images at one of the two facilities. In the second experiment, 26 of 71 images were compressed at 10:1, 19 of 71 were compressed at 20:1, and 26 were not compressed. Analyses of the areas under the receiver-operating characteristic curves showed no significant differences in detection of pulmonary abnormalities between film and CRT. In detecting interstitial pulmonary abnormalities, film was more sensitive than CRT monitor. There were no significant differences in observers' performances between the two different kinds of CRT workstation. Subjective evaluation of image quality showed that images irreversibly compressed to the ratios of 10:1 and 20:1 were inferior to original images. Although further considerations are needed with regard to spatial resolution requirements, image processing, and image compression, the utilization of CR CRT image as a substitute for CR film image will be possible.

Data Display↗

Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors.

PURPOSE: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode-ray tube (CRT) monitor in the detection of simulated support catheters on bedside chest radiographs. MATERIALS AND METHODS: The ethics committee did not require approval or patient informed consent when this study began. Because of a change in regulations, before images were acquired the nature of the study and procedures were explained to patients or their relatives, and consent was then obtained. A total of 131 catheter fragments (12-14 per radiograph) were superimposed over 10 anteroposterior bedside chest radiographs obtained with storage phosphor technology. Images were displayed on an LCD monitor (1536 x 2048 matrix) and a CRT monitor (2048 x 2560 matrix). Five radiologists independently located the catheter fragments and rated their confidence in detection with bright and subdued ambient light. A two-way analysis of variance and the Friedman test were used for statistical analysis. RESULTS: There was no significant difference for either display type with respect to correctly detected catheter fragments (mean sensitivity, 56.6% and 56.0% for the CRT and the LCD monitors, respectively, with bright light and 61.2% for both monitors with subdued light). With both display types, detection rate with bright light decreased significantly (P < .05). False-positive rates and confidence ratings were not significantly affected by monitor type or ambient light. CONCLUSION: In a study with simulation of clinical conditions, performance of the LCD monitor and high-resolution CRT monitor for detection of support catheters on bedside chest radiographs was equivalent. With both displays, detection performance was equally reduced with bright ambient light.

Aged↗

Do liquid crystal displays assure better readability than cathode-ray tubes?

Flat-panel displays, especially liquid crystal displays (LCDs), are now firmly established as important devices for information displays. But do LCDs assure better readability than cathode-ray tubes (CRTs)? We carried out an experiment using four types of displays: negative and positive CRTs, and LCDs with and without backlighting. A syllable-checking task using the Japanese katakana alphabet was conducted among fifteen healthy workers. They were divided into three groups; Group 1 had five young males aged 25 to 29, Group 2 was made up of five young females aged 18 to 24, and Group 3 consisted of five middle-aged workers who were 40 to 50 years old. We used four ambient light levels: 200 lx, 500 lx, 1250 lx without reflected glare, and 500 lx with reflected glare, on the display screens from behind. The illuminance of the glare was approximately 200 cd/m2. Multiple regression analysis showed that non-backlit LCDs reduced reading performance in middle-aged subjects significantly. Since middle-aged workers have more difficulties than young workers, they need more appropriate displays and a more comfortable illuminance environment than younger workers.

Adolescent↗

Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules.

OBJECTIVE: To compare observer performance using liquid-crystal display (LCD) and cathode-ray tube (CRT) monitors in the interpretation of soft-copy chest radiographs for the detection of small solitary pulmonary nodules. MATERIALS AND METHODS: By reviewing our Medical Center's radiologic information system, the eight radiologists participating in this study (three board-certified and five resident) retrospectively collected 40 chest radiographs showing a solitary noncalcified pulmonary nodule approximately 1 cm in diameter, and 40 normal chest radiographs. All were obtained using a storage-phosphor system, and CT scans of the same patients served as the gold standard for the presence of a pulmonary nodule. Digital images were displayed on both high-resolution LCD and CRT monitors. The readers were requested to rank each image using a fivepoint scale (1 = definitely negative, 3 = equivocal or indeterminate, 5 = definitely positive), and the data were interpreted using receiver operating characteristic (ROC) analysis. RESULTS: The mean area under the ROC curve was 0.8901+/- 0.0259 for the LCD session, and 0.8716+/- 0.0266 for the CRT session (p > 0.05). The reading time for the LCD session was not significantly different from that for the CRT session (37.12 and 41.46 minutes, respectively; p = 0.889). CONCLUSION: For detecting small solitary pulmonary nodules, an LCD monitor and a CRT monitor are comparable.

Data Display↗

[Newly developed monitor for IVR: liquid crystal display (LCD) replaced with cathode ray tube (CRT)].

For physicians who monitor images during interventional radiology (VR), we have built and been using a system that employs a liquid crystal display (LCD) instead of the conventional cathode ray tube (CRT). The system incorporates a ceiling-suspension-type monitor (three-display monitor) with an LCD on each of the three displays for the head and abdominal regions and another ceiling-suspension-type monitor (5-display monitor) with an LCD on each display for the cardiac region. As these monitors are made to be thin and light in weight, they can be placed in a high position in the room, thereby saving space and allowing for more effective use of space in the X-ray room. The system has also improved the efficiency of operators in the IVR room. The three-display folding mechanism allows the displays to be viewed from multiple directions, thereby improving the environment so that the performance of IVR can be observed.

Data Display↗

The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films.

Studies of observer performance with non-manipulated digital images are almost lacking; nor has the effect of cathode ray tube (CRT) display formats been evaluated. The present study compared the diagnostic accuracy of observers with and without clinical experience in evaluating intra-oral dental films and the corresponding non-manipulated digitized images. Three different-sized (5", 9", 17") monitors were used to study the effect of CRT display format. Artificial radiolucent and radiopaque lesions in dry human mandibles were examined. ROC curve areas were averaged and cross-tabulated according to viewing method and observer experience. For the total group, the non-manipulated digital images resulted in smaller ROC curve areas than the plain films for all CRT formats, with a significantly inferior result for the 17" images (p = 0.036). The increase in diagnostic accuracy of the digital images with decreasing CRT size was not significant (p > 0.05). There was some difference in the mean ROC curve areas between teachers and students, but the effect of the viewing methods was not significant. In terms of observer performance, the experienced observers demonstrated a reduced, and the inexperienced an increased, variability with the digital images compared with conventional film.

Clinical Competence↗