Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Electrochemical effect on denitrification in different microenvironments around anodes and cathodes.

A bio-anode reactor and a bio-cathode reactor were developed to investigate the microenvironments around anodes and cathodes and their effects on denitrification. With an applied current of 40 mA, the oxidation-reduction potentials (ORPs) in the bio-cathode and bio-anode reactors were 100-200 mV lower and 50 mV higher, respectively, than that in the control reactor (a normal bio-reactor). The cathode reaction enhanced denitrification and the anode reaction inhibited denitrification. At 40 mA, the denitrification rate in the bio-cathode reactor was 55.1% higher than that in the control reactor. At 75 mA, the denitrification rate in the bio-anode reactor was just 33.5% of that in control reactor. Electric current of less than 20 mA had no effect on the most probable number (MPN) of denitrifiers, but at 75 mA, the MPN of denitrifiers decreased by 90% in the bio-anode reactor. In the bio-cathode reactor, the MPN of denitrifiers increased more than 100% for the lower ORP environment produced by a cathode reaction at 75 mA.

Bacteria↗

Cathodic oxygen consumption and electrically induced osteogenesis.

Small amounts of electric current stimulate bone formation in the region of a cathode. The purpose of this experiment is to compare changes in oxygen and hydroxyl ion concentration that occur at the cathode at current levels known to be capable of inducing osteogenesis (10-20 muamps) with those changes that occur at current levels known to be toxic to bone (100 muamps). An oxygen consumption chamber containing an oxygen electrode is fitted with two stainless steel electrodes which are connected to a constant current source. At the cathode, with a current of 100 muamps, oxygen is consumed at nearly stoichiometric rates. At higher current (100 muamps) levels, cathodic oxygen consumption gives way to hydrogen evolution. Cathodic hydroxyl ion production is directly proportional to current. It is concluded from these in vitro experiments that at 10-20 muamps the oxygen tension in the vicinity of the cathode is lowered and the pH is moderately increased. At 100 muamps the oxygen tension is not lowered, but the pH is increased dramatically. If these same changes occur in the vicinity of a cathode in vivo, then lowering the local tissue oxygen tension and raising the local pH may be mechanisms operative in electrically induced bone formation.

Chemical Phenomena↗

A mathematical model of make and break electrical stimulation of cardiac tissue by a unipolar anode or cathode.

Numerical simulations of electrical stimulation of cardiac tissue using a unipolar extracellular electrode were performed. The bidomain model with unequal anisotropy ratios represented the tissue, and the Beeler-Reuter model represented the active membrane properties. Four types of excitation were considered: cathode make (CM), anode make (AM), cathode break (CB), and anode break (AB). The mechanisms of excitation were: for CM, tissue under the cathode was depolarized to threshold; for AM, tissue at a virtual cathode was depolarized to threshold; for CB, a long cathodal pulse produced a steady-state depolarization under the cathode and hyperpolarization at a virtual anode. At the end (break) of the pulse, the depolarization diffused into the hyperpolarized tissue, resulting in excitation. For AB, a long anodal pulse produced a steady-state hyperpolarization under the anode and depolarization at a virtual cathode. At the end (break) of the pulse, the depolarization diffused into the hyperpolarized tissue, resulting in excitation. For AB stimulation, decay of the hyperpolarization faster than that of the depolarization was necessary. The thresholds for rheobase and diastolic CM, AM, CB, and AB stimulation were 0.038, 0.41, 0.49, and 5.3 mA, respectively, for an electrode length of 1 mm and a surface area of 1.5 mm2. Threshold increased as the size of the electrode increased. The strength-duration curves for CM and AM were similar except when the duration was shorter than 0.2 ms, in which case the AM threshold rose more quickly with decreasing duration than did the CM threshold. CM and AM resulted in similar strength-frequency curves. The model agrees qualitatively, but (in some cases) not quantitatively, with experiments.

Animals↗

Cathodal current-induced vasodilation to single application and the amplified response to repeated application in humans rely on aspirin-sensitive mechanisms.

Assumed to rely on an axon reflex, the current-induced vasodilation (CIV) interferes with the microvascular response to iontophoretic drug delivery. Mechanisms resulting in CIV are likely different at the anode and at the cathode. While studies have been conducted to understand anodal CIV, little information is available on cathodal CIV. The present study investigates CIV observed following 0.1-mA cathodal applications on forearms of healthy volunteers and the possible mechanisms involved. Results are expressed in percentage of the cutaneous heat-induced maximal vascular conductance [%MVC (means +/- SE)]. 1) The amplitude of CIV was proportional to the duration of cathodal currents for periods of <1 min: r = 0.99. 2) Two current applications of 10 s, with 10-min interstimulation interval, induced a higher peak value of CIV (79.1 +/- 8.6% MVC) than the one obtained with all-at-once 20-s current application (39.5 +/- 4.3% MVC, P < 0.05). This amplified vascular response due to segmental application was observed for all tested interstimulation intervals (up to 40 min). 3) Two hours and 3 days following pretreatment with 1-g oral aspirin, the CIV observed following cathodal application, as well as the difference of cathodal CIV amplitude between all-at-once and segmented applications, were reduced. These findings suggest a role of prostaglandins, not only released from endothelial or smooth muscle cells, as direct vasodilator and/or as a sensitizer. Thus aspirin pretreatment could be used to decrease CIV resulting from all-at-once and repeated cathodal application and facilitate the study of the specific vascular effect induced by the drug delivered.

Administration, Oral↗

Skin microcirculation during tapwater iontophoresis in humans: cathode stimulates more than anode.

The aim of this controlled study was to evaluate the influence of anode and cathode on skin blood flow by using direct current. Skin microcirculation and skin temperature of 26 healthy subjects (17 men and 9 women, 20-64 years of age) without any vascular diseases were registered when a tapwater iontophoresis was applied. Thermoindifferent water temperature was used to prevent thermic effects on microcirculation. The blood flow measurement was conducted by laser-Doppler flowmetry on the proximal forearm and on the back of the wrist. The skin temperature was measured before and after treatment by an infrared thermometer. In 19 persons there was an intense erythema on the side of the cathode and an only modest one on the side of the anode, while 7 persons showed meager reactions on both sides. The erythema rose strongly from the distal (back of the hand) to the proximal forearm. The comparison of the microcirculation of the arms showed an increase of 120% at the anode and of 700% at the cathode. The differences between the two sides were significant (P < 0.001). After the end of tapwater iontophoresis the skin temperature increased more on the side of the cathode than on the anode side (P < 0.001). The frequency of vasomotion did not change. The vasomotion amplitude increased 67% at the anode (P < 0.05) and 175% at the cathode (P < 0.001). The increased blood flow effect was not age or sex dependent. Although the increased blood flow effect was six times larger on the cathode side, the subjects did not perceive any subjective difference.

Adult↗

The cathodal OFF response of electric taste in rats.

The cathodal OFF response in electric taste, the production of a taste sensation at the break of a microampere cathodal current passed through the tongue, was studied electrophysiologically in the rat chorda tympani nerve. Previous work in electric taste has centered on ON responses to both anodal and cathodal currents. The cathodal OFF response, like ON responses, increased with increasing current intensity until a saturated response level was achieved. Unlike previously reported ON responses, the OFF response did not show a sensitivity to the ionic composition of the fluid bathing the tongue making this the first electrophysiological report of ion insensitivity in electric taste. The cathodal OFF response was sensitive to the duration of the current pulse preceding it. Longer pulses produced larger OFF responses, until with very long pulses (seconds) a saturated response level was achieved. The half maximal response occurred at 12.5 ms. These results have been interpreted to mean that the cathodal OFF response has an origin other than the microvillus membrane, the site most often implied for ON responses, due largely to its ion insensitivity. A probable location may reside with ion channels transversing the basal membrane which are transiently excited at the break of the current resulting in excitation at the receptor-afferent synapse.

Animals↗

Effects of unipolar cathodal and bipolar stimulation on vulnerability of ischemic ventricles to fibrillation.

The effects of unipolar and bipolar stimulation on ventricular fibrillation threshold were studied during acute occlusion of the left anterior descending coronary artery in 13 anesthetized dogs. Values for ventricular fibrillation threshold were determined by delivering trains of rapid bipolar or unipolar pulses (100/sec) during the vulnerable period. The mean threshold value was found to be 13.0 ma for bipolar, 13.9 ma for unipolar anodal and 21.0 ma for unipolar cathodal stimulation. Ventricular fibrillation threshold was significantly lower (P less than 0.01) with both unipolar anodal and bipolar stimulation than with unipolar cathodal stimulation. In these animals, the first premature beats induced by the rapid stimuli occurred significantly earlier with unipolar anodal and bipolar stimulation than with unipolar cathodal stimulation. The effect of competition of unipolar or bipolar pacing stimuli with normally conducted ventricular beats was also studied in a group of 16 dogs. Repeated trials of competitive pacing during coronary occlusion showed that the incidence of ventricular fibrillation was significantly greater (P less 0.05) with bipolar pacing (36 percent) than with unipolar cathodal pacing (15 percent). These results indicate that bipolar pacing is potentially more dangerous than unipolar cathodal pacing and suggest that the incidence of pacemaker-induced ventricular fibrillation might be further reduced by the use of unipolar cathodal stimulation during acute myocardial infarction.

Animals↗

Treatment of nitrophenols by cathode reduction and electro-Fenton methods.

This study deals with the degradation of various nitrophenols by cathode reduction and electro-Fenton methods. Phenols (Poh), 2-nitrophenol (2-NP), 3-nitrophenol (3-NP), 4-nitrophenol (4-NP), and 2,4-dinitrophenol (2,4-DNP) are treated and different degradation sequences are obtained. The relationship between the structure and activities of nitrophenols is discussed. Using 4-NP as a model nitrophenol, the electrochemical behaviors on graphite cathode and Pt anode are analyzed by cyclic voltammetry. The contribution of different reactions to the degradation of 4-NP is investigated in divided cells. The degradation of 4-NP is much faster in the cathode cell than in the anodic cell. In the cathode cell, the degradation of 4-NP is significantly enhanced by the introduction of aeration and Fe(2+). Ultraviolet-visible (UV-vis) spectra reveal different reaction pathways for the degradation in the anodic cell and cathode cell. Treatment of high concentration of 4-NP in the undivided cell shows that more than 98% removal of 4-NP and about 13% removal of total organic carbon (TOC) are obtained for both processes, while the subsequent biodegradability test shows that electro-Fenton can eliminate the toxicity and improve the biodegradability of 4-NP. Negligible quantity of nitrate and nitrite ions detected in both processes indicates that there is no direct release of -NO(2) and -NO groups from 4-NP and its degradation intermediates. Intermediates such as hydroquinone and bezoquinone are detected by gas chromatography/mass spectrum (GC/MS). The degradation pathway of 4-NP in electro-Fenton process is proposed as the cathode reduction followed by hydroxyl oxidation.

Benzoquinones↗

Effect of sodium dodecyl sulfate on the rate of hydrogen evolution at a cathode.

The effect of H(2) evolution on the mass-transfer coefficient of cathode reduction of potassium ferricyanide at a mercury cathode was studied with the aim of (i) comparing the mass transfer behavior at a Hg cathode with that at solid electrodes under gas-evolving conditions and (ii) testing the effect of anionic surface-active agent on the mass transfer behavior of an H(2)-evolving Hg cathode. It is found that the mass transfer coefficient at the Hg cathode was much higher than the value at a solid cathode. The mass transfer coefficient at H(2)-evolving Hg was found to decrease in the presence of sodium dodecyl sulfate (SDS) surfactant by an amount ranging from 58.8 to 76%, depending on the H(2) discharge rate and the SDS concentrations.

Journal Article↗

Electricity generation using an air-cathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane.

Microbial fuel cells (MFCs) are typically designed as a two-chamber system with the bacteria in the anode chamber separated from the cathode chamber by a polymeric proton exchange membrane (PEM). Most MFCs use aqueous cathodes where water is bubbled with air to provide dissolved oxygen to electrode. To increase energy output and reduce the cost of MFCs, we examined power generation in an air-cathode MFC containing carbon electrodes in the presence and absence of a polymeric proton exchange membrane (PEM). Bacteria present in domestic wastewater were used as the biocatalyst, and glucose and wastewater were tested as substrates. Power density was found to be much greater than typically reported for aqueous-cathode MFCs, reaching a maximum of 262 +/- 10 mW/m2 (6.6 +/- 0.3 mW/L; liquid volume) using glucose. Removing the PEM increased the maximum power density to 494 +/- 21 mW/m2 (12.5 +/- 0.5 mW/L). Coulombic efficiency was 40-55% with the PEM and 9-12% with the PEM removed, indicating substantial oxygen diffusion into the anode chamber in the absence of the PEM. Power output increased with glucose concentration according to saturation-type kinetics, with a half saturation constant of 79 mg/L with the PEM-MFC and 103 mg/L in the MFC without a PEM (1000 omega resistor). Similar results on the effect of the PEM on power density were found using wastewater, where 28 +/- 3 mW/m2 (0.7 +/- 0.1 mW/L) (28% Coulombic efficiency) was produced with the PEM, and 146 +/- 8 mW/m2 (3.7 +/- 0.2 mW/L) (20% Coulombic efficiency) was produced when the PEM was removed. The increase in power output when a PEM was removed was attributed to a higher cathode potential as shown by an increase in the open circuit potential. An analysis based on available anode surface area and maximum bacterial growth rates suggests that mediatorless MFCs may have an upper order-of-magnitude limit in power density of 10(3) mW/m2. A cost-effective approach to achieving power densities in this range will likely require systems that do not contain a polymeric PEM in the MFC and systems based on direct oxygen transfer to a carbon cathode.

Bacteria↗

In situ raman microscopy of individual LiNi0.8Co0.15Al0.05O2 particles in a Li-ion battery composite cathode.

Kinetic characteristics of Li+ intercalation/deintercalation into/from individual LiNi0.8Co0.15Al0.05O2 particles in a composite cathode were studied in situ using Raman microscopy during galvanostatic charge-discharge in 1.2 M LiPF6, ethylene carbonate (EC): ethyl methyl carbonate (EMC), 3:7 by volume. Ex situ spectroscopic analysis of a cathode that was removed from a tested high-power Li-ion cell, which suffered substantial power and capacity loss, showed that the state of charge (SOC) of oxide particles on the cathode surface was highly nonuniform despite deep discharge of the Li-ion cell at the end of the test. In situ monitoring of the SOC of selected oxide particles in the composite cathode in a sealed spectro-electrochemical cell revealed that the rate at which particles charge and discharge varied with time and location. The inconsistent kinetic behavior of individual oxide particles was attributed to degradation of the electronically conducting carbon matrix in the composite cathode upon testing. These local microphenomena are most likely responsible for the overall impedance rise of the cathode and contribute to the mechanism of lithium-ion cell failure.

Journal Article↗

Conductive-matrix-mediated alkaline Fe(III/VI) charge transfer: three-electron storage, reversible super-iron thin film cathodes.

An extended conductive matrix facilitates a 100-fold enhancement in charge storage for reversible Fe(III/VI) super-iron thin films. These films were deposited, by electrochemical reduction of Na2FeO4, with an intrinsic high capacity 3 e- cathodic storage of 485 mAh g(-1). Whereas 3 nm Fe(III/VI) films exhibited a high degree of reversibility (throughout 100 charge/discharge cycles), thicker films had been increasingly passive toward the Fe(VI) charge transfer. Films were alternatively deposited on either smooth or on extended conductive matrixes composed of high-surface-area Pt, Ti, and Au and probed galvanostatically and via cyclic voltammetry. A 100 nm Fe(VI) cathode, on the extended conductive matrixes, sustained 100-200 reversible three-electrode charge/discharge cycles, and a 19 nm thin film cathode sustained 500 such cycles. With a metal hydride anode, full cell storage was probed, and a 250 nm super-iron film cathode film sustained 40 charge/discharge cycles, and a 25 nm film was reversible throughout 300 cycles. Fe(VI) salts exhibit higher cathodic capacity and environmental advantages, and the films are of relevance toward the next generation charge storage chemistry for reversible cathodes.

Journal Article↗

Steady-state dc and impedance investigations of H2/O2 alkaline membrane fuel cells with commercial Pt/C, Ag/C, and Au/C cathodes.

The performances of H(2)/O(2) metal-cation-free alkaline anion-exchange membrane (AAEM) fuel cells operated with commercially available Au/C and Ag/C cathodes are reported for the first time. Of major significance, the power density obtained with 4 mg cm(-2) Ag/C (60% mass) cathodes was comparable to that obtained with 0.5 mg cm(-2) Pt/C (20% mass) electrodes, whereas the performance when using the same Ag/C cathode in a Nafion-based acidic membrane electrode assembly (MEA) was poor. These initial studies demonstrate that the oxygen reduction electrokinetics are improved when operating Pt/C cathodes at high pH in AAEM-based fuel cells as compared with operation at low pH (in Nafion-based proton-exchange membrane fuel cells). The results of in situ alternating current impedance spectroscopy were core to the assignment of the source of the limited performances of the AAEM-based fuel cells as being the limited supply of water molecules to the cathode reaction sites. Minimizing the thickness of the AAEM improved the performances by facilitating back-transport of water molecules from the anode (where they are generated) to the cathode. The urgent need for development of electrode architectures that are specifically designed for use in AAEM-based fuel cells is highlighted.

Journal Article↗

A high-performance cathode for the next generation of solid-oxide fuel cells.

Fuel cells directly and efficiently convert chemical energy to electrical energy. Of the various fuel cell types, solid-oxide fuel cells (SOFCs) combine the benefits of environmentally benign power generation with fuel flexibility. However, the necessity for high operating temperatures (800-1,000 degrees C) has resulted in high costs and materials compatibility challenges. As a consequence, significant effort has been devoted to the development of intermediate-temperature (500-700 degrees C) SOFCs. A key obstacle to reduced-temperature operation of SOFCs is the poor activity of traditional cathode materials for electrochemical reduction of oxygen in this temperature regime. Here we present Ba(0.5)Sr(0.5)Co(0.8)Fe(0.2)O(3-delta)(BSCF) as a new cathode material for reduced-temperature SOFC operation. BSCF, incorporated into a thin-film doped ceria fuel cell, exhibits high power densities (1,010 mW cm(-2) and 402 mW cm(-2) at 600 degrees C and 500 degrees C, respectively) when operated with humidified hydrogen as the fuel and air as the cathode gas. We further demonstrate that BSCF is ideally suited to 'single-chamber' fuel-cell operation, where anode and cathode reactions take place within the same physical chamber. The high power output of BSCF cathodes results from the high rate of oxygen diffusion through the material. By enabling operation at reduced temperatures, BSCF cathodes may result in widespread practical implementation of SOFCs.

Journal Article↗

Bifurcation points in the theory of axially symmetric arc cathodes.

Steady-state current transfer from arc plasmas to axially symmetric cathodes is treated in the framework of the model of nonlinear surface heating. An approach is developed to calculate the bifurcation points at which three-dimensional spot-mode solutions branch off from solutions describing the diffuse mode and axially symmetric spot modes. In particular, the first bifurcation point positioned on the diffuse-mode solution has been calculated, and thus its stability limit, i.e., the current below which the diffuse mode becomes unstable. Calculation results are given for the case of a tungsten cathode in the form of a circular cylinder in high-pressure plasmas. The effect produced on the stability limit by variations of control parameters (cathode dimensions, work function of the cathode material, plasma-producing gas, and its pressure) is studied and found to conform to trends observed experimentally. The stability limit is found to be much more sensitive to variations of control parameters than characteristics of the diffuse mode are, the strongest effect being produced by variations of cathode dimensions and of the work function of the cathode material. This finding conforms to the fact that the diffuse-spot transition is difficult to reproduce in the experiment.

Journal Article↗

Corticospinal volleys evoked by anodal and cathodal stimulation of the human motor cortex.

1. In fifteen neurologically normal subjects, corticospinal volleys evoked by transcranial stimulation of the motor cortex were recorded from the spinal cord using epidural electrodes in the high-thoracic and low-thoracic regions during surgery to correct scoliosis. 2. Anodal stimulation at the vertex produced complex corticospinal volleys that could be recorded at both sites, with multiple waves analogous to the D and I waves documented in animal experiments. These volleys were of higher amplitude when the cathode was 7 cm lateral to the vertex rather than 7 cm anterior. There were no differences in conduction time between the two recording sites for D and I waves, when these waves could be identified at the low-thoracic site. 3. Anodal stimuli of 150 V commonly produced a descending volley containing a single peak at both recording sites. Modest increases in stimulus intensity to 225-375 V produced a peak 0.8 ms in advance of the wave of lowest threshold in thirteen subjects and, in seven subjects, further increases produced an additional peak 1.7 ms in advance of the first-recruited wave. The early peaks increased in size with stimulus intensity, replacing the first-recruited wave. These results suggest that the site of impulse initiation with electrical stimulation of the motor cortex shifts from superficial cortex to deep structures, approximately 5 and 10-11 cm below the cortex. These sites are probably the internal capsule and the cerebral peduncle. 4. With cathode at the vertex and anode over the 'hand area' the response of lowest threshold occurred at the latency of the anodal D wave but could not be recorded at the low-thoracic site, suggesting that it was generated by the anode over the 'hand area'. Slightly higher intensities induced a 'cathodal D wave' and still higher intensities produced late peaks at latencies of anodal I waves. These cathodal D and I waves involved axons innervating lumbar segments. There was no evidence that cathodal stimulation preferentially produced I waves. Cathodal stimulation at the vertex with the anode 7 cm anteriorly produced similar results: D waves were produced at relatively low intensities, but I waves appeared at relatively high stimulus intensities if at all.(ABSTRACT TRUNCATED AT 400 WORDS)

Adolescent↗

Non-synaptic mechanisms underlie the after-effects of cathodal transcutaneous direct current stimulation of the human brain.

Although cathodal transcranial direct current stimulation (tDCS) decreases cortical excitability, the mechanisms underlying DC-induced changes remain largely unclear. In this study we investigated the effect of cathodal DC stimulation on spontaneous neural activity and on motor responses evoked by stimulation of the central and peripheral nervous system. We studied 17 healthy volunteers. Transcranial magnetic stimulation (TMS) and transcranial electrical stimulation (TES) of the motor area were used to study the effects of cathodal tDCS (1.5 mA, 10 min) on resting motor threshold and motor evoked potentials (MEPs) recorded from the contralateral first dorsal interosseous muscle (FDI). The electroencephalographic (EEG) activity in response to cathodal tDCS was analysed by power spectral density (PSD). Motor axonal excitability changes in response to transcutaneous DC stimulation of the ulnar nerve (0.3 mA, 10 min) were assessed by testing changes in the size of the compound muscle action potential (CMAP) elicited by submaximal nerve stimulation. Cathodal tDCS over the motor area for 10 min increased the motor threshold and decreased the size of MEPs evoked by TMS for at least 60 min after current offset (t(0) 71.7 +/- 5%, t(20) 50.8 +/- 11%, t(40) 47.7 +/- 7.7%, and t(60) 39.7 +/- 6.4%, P < 0.01). The tDCS also significantly decreased the size of MEPs elicited by TES (t(0) 64 +/- 16.4%, P = 0.09; t(20) 67.6 +/- 10.8%, P = 0.06; and t(40) 58.3 +/- 9.9%, P < 0.05). At the same time in the EEG the power of delta (2-4 Hz) and theta (4-7 Hz) rhythms increased (delta 181.1 +/- 40.2, P < 0.05; and theta 138.7 +/- 27.6, P = 0.07). At the peripheral level cathodal DC stimulation increased the size of the ulnar nerve CMAP (175 +/- 34.3%, P < 0.05). Our findings demonstrate that the after-effects of tDCS have a non-synaptic mechanism of action based upon changes in neural membrane function. These changes apart from reflecting local changes in ionic concentrations, could arise from alterations in transmembrane proteins and from electrolysis-related changes in [H(+)] induced by exposure to constant electric field.

Adult↗

Vulnerability of the mildly ischemic ventricle to cathodal, anodal, and bipolar stimulation.

We studied the difference between myocardial vulnerability to arrhythmias caused by cathodal, anodal, and bipolar stimulation in 29 dogs with partial right coronary artery occlusion. We used 2-msec duration stimuli of up to 8 mA to determine the ventricular vulnerable periods, their relationship to the refractory periods, and the fibrillation or multiple response thresholds for unipolar anodal and cathodal stimulation after two premature ventricular contractions. The vulnerable period for arrhythmias began at the end of the respective refractory periods and terminated at a specific time within the cardiac cycle. Within this period the arrhythmia and excitation thresholds were equal. Because shorter refractory periods were obtained with anodal stimulation than cathodal, the vulnerable periods for anodal stimulation were longer. This indicated that the vulnerable periods for bipolar stimulation also would be longer than for unipolar cathodal stimulation since bipolar and anodal refractory periods are equal when the cathode and anode are of similar surface area. Results from seven of the experiments showed that a dual focus of excitation, which can only occur with bipolar stimulation, did not make the ventricle more vulnerable to arrhythmias than did unifocal stimulation. These results indicate that the difference between the arrhythmia vulnerability to unipolar cathodal, anodal, and bipolar stimulation is dependent on the relationship between their excitability characteristics, i.e., their strength-interval curves.

Animals↗