Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bronchoscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Outbreaks of contaminated broncho-alveolar lavage related to intrinsically defective bronchoscopes.

From 5 March 2001 to 19 October 2001, outbreaks of broncho-alveolar lavage (BAL) contamination with Enterobacteraceae were detected in our 700-bed institution. We report the investigation of these outbreaks. A case was defined as the occurrence of pairs of specific Enterobacteraceae in BAL specimens among any patients who underwent bronchoscopy in the respiratory unit during the period of the outbreak. Contamination was identified in 117 BAL samples during three outbreaks among 418 patients, and was associated with bronchoscopes 11 and 12 (P<0.001). The other five devices in use were not linked with the outbreaks. During the first outbreak, particular pairs of micro-organisms were associated with a specific bronchoscope (Klebsiella pneumoniae/Proteus vulgaris with bronchoscope 11, and Morganella morganii/Proteus mirabilis with bronchoscope 12). Cultures of sputa from two patients also yielded M. morganii some days after bronchoscopic examination. Isolates from contaminated BAL samples and bronchoscope 11 had similar patterns by pulsed-field gel electrophoresis. No further cases occurred after removal of the implicated bronchoscopes. No deficiencies in disinfection procedures were detected and the source of contamination was found to be a loose port of the biopsy channel of the bronchoscope. Our findings underscore the urgent need to test bronchoscopic samples regularly and to improve the design and structure of bronchoscopes.

Bronchoalveolar Lavage Fluid↗

Flexible bronchoscopic management of airway foreign bodies in children.

OBJECTIVES: To evaluate experience with the flexible bronchoscopic management of tracheobronchial foreign bodies (TFBs) in children (age < or = 16 years). DESIGN: All pediatric bronchoscopies performed by the bronchoscopy section at Mayo Clinic Rochester from 1990 through June 2001 for the suspicion of TFBs were reviewed. Information analyzed included the types of bronchoscope (rigid vs flexible) and techniques used, success rates of extraction of TFBs, and complications. RESULTS: Of the 94 children suspected of having TFBs, 39 children (28 boys and 11 girls; mean age, 47.3 months) were found to have 40 TFBs. The flexible bronchoscope was used exclusively to extract TFBs in 24 patients, and in 2 patients in whom the rigid bronchoscopic procedure was unsuccessful. Flexible bronchoscopy was performed through an endotracheal tube in 19 children. In the other five children, the procedure was accomplished through a laryngeal mask airway (LMA). In two additional patients in whom the rigid bronchoscopic procedure was unsuccessful, the instrument served as a conduit for the passage of the flexible bronchoscope. The extraction instruments employed included ureteral stone baskets and stone forceps. Since 1994, all extractions of TFBs were successfully accomplished with the flexible bronchoscope. Complications occurred in four patients who underwent rigid bronchoscopy, and included postbronchoscopy laryngeal edema manifested by stridor, cough, and respiratory distress. These resolved quickly with medical therapy. CONCLUSIONS: Flexible bronchoscopic extraction of pediatric TFBs can be performed safely with minimal risks and complications. In our experience, it was successful in all children in whom it was employed. Nevertheless, we caution that provisions be made to provide immediate rigid bronchoscopic management, should the attempts at flexible bronchoscopic extraction fail.

Adolescent↗

Bronchoscope damage and repair costs: results of a regional postal survey.

Flexible fiberoptic bronchoscopy is a commonly performed procedure for which the indications, technical aspects, and potential patient complications have been well described. However, limited information is available regarding damage to the instrument itself. In order to better describe the types and causes of bronchoscope damage, repair costs, and time out of service, we performed a postal survey of hospital bronchoscopy laboratories in Alabama, Mississippi, and Louisiana. We received 43 completed surveys from laboratories that perform an average of 233 bronchoscopies per year. The respondents reported 103 episodes of bronchoscope damage, the majority of which consisted of damage to the bronchoscope cover, broken fiber bundles, malfunction of the bending apparatus, and suction channel damage. The respondents attributed 62% of all the damage to one of the three following categories: unknown, improper handling, and damage caused by biopsy forceps, brushes, or needles. Of the 103 episodes of bronchoscope damage, 66 (64%) were judged to be preventable, 13.6% not preventable, and 17.5% to be indeterminant. The average time out of service (mean, SD) for each damaged bronchoscope was 3.5 (3.9) weeks, and the average repair cost per episode of bronchoscope damage was $2,726.13 ($1,391.21). At least 19 episodes of bronchoscope damage occurred during cleaning and disinfecting procedures. We conclude that the majority of bronchoscope damage and repair costs should be potentially preventable and suggest that a program to familiarize all personnel handling bronchoscopes with proper maintenance and handling procedures should decrease the risk of bronchoscope damage.

Alabama↗

Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes.

BACKGROUND: Several outbreaks and pseudo-outbreaks of Pseudomonas aeruginosa and Serratia marcescens infections associated with bronchoscopy have been reported. We conducted an investigation of P. aeruginosa and S. marcescens isolates related to bronchoscopy at a community hospital. METHODS: We reviewed the records of all bronchoscopic procedures at the community hospital from July to October 2001. Environmental samples were obtained. Pulsed-field gel electrophoresis (PFGE) was performed on isolates of P. aeruginosa. RESULTS: From July 1 to October 31, 2001, 66 bronchoscopic procedures were performed in 60 patients, and 43 specimens were obtained for bacterial culture; 20 of the specimens (47 percent) were positive for P. aeruginosa. Six (30 percent) of the specimens that were positive for P. aeruginosa also yielded S. marcescens. All 20 P. aeruginosa isolates were associated with procedures performed with three of four new bronchoscopes from the same manufacturer. Contrary to manufacturing specifications, the biopsy-port caps on all four bronchoscopes were easily removable, and P. aeruginosa was cultured from the biopsy ports of the three implicated bronchoscopes. The PFGE patterns of P. aeruginosa isolates from the bronchoscopes, patients, and two environmental samples were indistinguishable. One patient was hospitalized with P. aeruginosa pneumonia 11 days after bronchoscopy. The manufacturer reported a design change instituted in 1997, and production problems may have resulted in the distribution of bronchoscopes that did not meet specifications. CONCLUSIONS: We documented contamination of bronchoscopes with P. aeruginosa and S. marcescens and possible infection of patients at a community hospital as a result of the inadequate disinfection of bronchoscopes because of a manufacturing defect.

Adult↗

Adult and paediatric size bronchoscopes for bronchoalveolar lavage in mechanically ventilated patients: yield and side effects.

BACKGROUND: Bronchoalveolar lavage is considered a safe procedure. When performed in the mechanically ventilated patient, however, potentially harmful effects on respiratory and haemodynamic functions have been reported in which the size of the bronchoscope may play a part. Two different size bronchoscopes (adult and paediatric) were therefore investigated with regard to bronchoalveolar lavage yield and side effects. METHODS: Twenty mechanically ventilated patients underwent bronchoalveolar lavage with both adult and paediatric bronchoscopes in a randomised sequential manner. RESULTS: In a total of 45 pairs of bronchoalveolar lavage procedures no difference was noted between adult and paediatric bronchoscopes with regard to total cell yield, differential cell count, and microbiological results. Peak intratracheal pressure increased with the adult bronchoscope only. Systemic arterial pressures increased more with the adult than with the paediatric bronchoscope. PaO2 decreased with the adult but not with the paediatric bronchoscope. CONCLUSIONS: The paediatric bronchoscope offers a comparable bronchoalveolar lavage yield in mechanically ventilated patients to the adult bronchoscope, while the respiratory and haemodynamic side effects are significantly lower than with the adult size instrument.

Bronchoalveolar Lavage Fluid↗

Bronchoscopic treatment of intraluminal typical carcinoid: a pilot study.

OBJECTIVE: The curative potential of various bronchoscopic treatments such as Nd:YAG laser, photodynamic therapy, and brachytherapy for the treatment of intraluminal tumor has been reported previously. Bronchoscopic treatment can be used to treat small intraluminal tumor with curative intent, such as in patients with roentgenologically occult squamous cell cancer. In a retrospective study, we showed that bronchoscopic treatment provided excellent local control with surgical proof of cure in 6 of 11 patients with intraluminal typical bronchial carcinoid. METHODS: In a prospective study, 19 patients (8 women and 11 men) with resectable intraluminal typical bronchial carcinoid have undergone bronchoscopic treatment under general anesthesia. Median age was 44 years (range, 20-74 years). If tumor persisted after 2 bronchoscopic treatment sessions, surgery was performed within 4 months after the treatment. RESULTS: Bronchoscopic treatment was able to completely eradicate tumor in 14 of the 19 patients (complete response rate 73%, 95% CI: 49%-91%). Median follow-up of these patients is 29 months (range, 8-62 months). One patient had severe cicatricial stenosis after bronchoscopic treatment, and sleeve lobectomy was necessary. No residual carcinoid was found in the resected specimen. In the remaining 5 patients, bronchoscopic treatment did not result in a complete response and radical surgical resection was performed afterward with confirmation of residual carcinoid in the resected specimen. Median follow-up of the surgical group is 34 months (range, 12-62 months). CONCLUSIONS: Current data suggest that bronchoscopic treatment may be an effective alternative to surgical resection in a subgroup of patients with resectable intraluminal typical bronchial carcinoid. It alleviated the necessity of surgical resection in 68% (95% CI: 43%-87%) of the patients.

Adult↗

Lung adenocarcinomas diagnosed by open lung or thoracoscopic vs bronchoscopic biopsy.

STUDY OBJECTIVES: To examine the characteristics of peripheral lung adenocarcinomas diagnosed by open lung or video-assisted thoracoscopic surgery (VATS) biopsy. DESIGN: We used retrospective analysis to compare tumor stage, pleural involvement, central tumor fibrosis, and the number of bronchi or vessels involved with tumors of small peripheral lung adenocarcinomas diagnosed by bronchoscopic biopsy. PATIENTS: Subjects had lung adenocarcinomas diagnosed by open lung or VATS (n=22) and those diagnosed by bronchoscopic biopsy (n=22), which were matched by tumor size. RESULTS: The T1N0M0 tumor was notably more frequent in the open lung or VATS group (77.3%) than in the bronchoscopic biopsy group (36.4%) (p<0.01). Tumors invading beyond the pleural surface were less frequent in the open lung or VATS group (4.5%) than in the bronchoscopic biopsy group (40.9%) (p<0.01). The grade of in-tumor central fibrosis--a malignancy factor and the cause of bronchi or vessel involvement with tumors-was significantly lower in the open lung or VATS group than in the bronchoscopic biopsy group (p<0.01). The number of bronchi or vessels involved with tumors was significantly fewer in the open lung or VATS group than in the bronchoscopic biopsy group (p<0.001). CONCLUSIONS: (1) Lung adenocarcinomas diagnosed by open lung or VATS biopsy were more frequently T1N0M0 than those diagnosed by bronchoscopic biopsy, which was caused by low grade of central tumor fibrosis rather than small tumor size. (2) They were infrequently diagnosed by bronchoscopic biopsy because few bronchi were involved by tumors due to the low grade of central tumor fibrosis. (3) Small pulmonary nodules not diagnosable by bronchoscopic biopsy should be diagnosed aggressively using VATS biopsy to detect early-stage lung cancer.

Adenocarcinoma↗

A method for bronchoscope tracking by combining a position sensor and image registration.

This paper describes a method for tracking a bronchoscope by combining a position sensor and image registration. A bronchoscopy guidance system is a tool for providing real-time navigation information acquired from pre-operative CT images to a physician during a bronchoscopic examination. In this system, one of the fundamental functions is tracking a bronchoscope's camera motion. Recently, a very small electromagnetic position sensor has become available. It is possible to insert this sensor into a bronchoscope's working channel to obtain the bronchoscope's camera motion. However, the accuracy of its output is inadequate for bronchoscope tracking. The proposed combination of the sensor and image registration between real and virtual bronchoscopic images derived from CT images is quite useful for improving tracking accuracy. Furthermore, this combination has enabled us to achieve a real-time bronchoscope guidance system. We performed evaluation experiments for the proposed method using a rubber phantom model. The experimental results showed that the proposed system allowed the bronchoscope's camera motion to be tracked at 2.5 frames per second.

Artificial Intelligence↗

Cluster of Trichosporon mucoides in children associated with a faulty bronchoscope.

BACKGROUND: Several outbreaks of Pseudomonas aeruginosa infection associated with a specific model of fiberoptic bronchoscope have been reported. In a 3-week period in September 2000, we noticed an increased number of Trichosporon mucoides isolates recovered from bronchoalveolar lavage (BAL) specimens collected at our hospital. We investigated the circumstances surrounding these isolates. METHODS: Outbreak investigation was conducted, and the medical records of the affected patients were reviewed retrospectively for evidence of positive cultures for T. mucoides from BAL specimens. Specimens collected during the investigation were inoculated onto fungal culture medium and yeasts were identified with API-20C (BioMèrieux-Vitek). RESULTS: During the 3-week period BAL specimens from six patients yielded growth of T. mucoides. These six high risk patients had emergency bronchoscopy performed as a workup for pneumonia and/or respiratory distress. A Model BF XP-40 bronchoscope (Olympus) had been used in all six patients. Cultures of the bronchoscope (external body and the lumen), bronchoscope disinfector, 2% glutaraldehyde disinfecting solution and water filters/supply were performed. Only fluid from the bronchoscope lumen yielded growth of T. mucoides. Air sample cultures of the bronchoscopy suites were negative. Medical records review disclosed that affected patients were not readmitted with infection with T. mucoides and had no adverse outcomes. The bronchoscope was removed from service and returned to the manufacturer. CONCLUSION: Routine surveillance and aggressive investigation identified persistent T. mucoides contamination of one bronchoscope. The bronchoscope manufacturer later recalled the BF XP-40 model for corrective revision.

Adolescent↗

A pseudoepidemic of Mycobacterium chelonae: contamination of a bronchoscope and autocleaner.

BACKGROUND: At fibreoptic bronchoscopy the potential exists for contamination of bronchoscopes and microbiological specimens. Patients may also be cross infected with acid fast bacilli (AFB). During a five month period, 12 bronchial wash specimens of 65 patients undergoing bronchoscopy, one bronchoscope and an autocleaner, were contaminated with the AFB, Mycobacterium chelonae (MCH). AIM: To eradicate AFB contamination of bronchoscopy specimens by identifying sources of contamination and modifying disinfection procedures. METHODS: To identify the source of contamination, samples for AFB culture were taken from three bronchoscopes, the autocleaner and water taps. To eradicate MCH contamination, the bronchoscopes were soaked in 2% glutaraldehyde overnight and flushed with 70% alcohol. Disinfection procedures were altered by using sterile water and containers in cleaning. Autocleaner use was discontinued. RESULTS: The autocleaner, one bronchoscope and 12 bronchial wash specimens were contaminated with MCH. All contaminants had similar electrophoretic banding on probing of their DNA fragments, suggesting a common clone of origin. After the alterations in disinfection procedures and despite prolonged soaking in 2% glutaraldehyde, three further contaminated wash specimens were isolated from one bronchoscope. Only after ethylene oxide sterilisation of this bronchoscope was the contamination overcome. Since then no further MCH contamination has occurred. No patient required treatment and there has been no clinical evidence of mycobacterial disease. CONCLUSION: To avoid contamination of bronchoscopy specimens with MCH, use of autoclearners should be discouraged and sterile water and containers used in cleaning procedures. If MCH contamination occurs in this setting, the bronchoscope and dismantled valve mechanism should undergo ethylene oxide sterilisation.

Bronchoalveolar Lavage Fluid↗

The use of the pediatric fiberoptic bronchoscope in adults.

Standard fiberoptic bronchoscopes with external diameters of more than 4.5 mm are commonly used to diagnose pulmonary diseases in adults. A smaller bronchoscope with an external diameter of 3.5 mm has been in use to examine pediatric airway disorders. Three adult patients, 2 with hemoptysis and 1 with cough, when examined using the standard fiberoptic bronchoscope, had nondiagnostic findings. Subsequent examination using the pediatric fiberoptic bronchoscope revealed endobronchial lesions in all 3 patients. On the basis of the findings of pediatric bronchoscopic examination, it was possible to provide appropriate therapeutic decisions, which may not have resulted from the standard bronchoscopic examinations. The smaller external diameter of the pediatric bronchoscope will enable the bronchoscopist to detect endobronchial lesions in smaller airways that cannot be visualized by the standard fiberoptic bronchoscopes.

Adult↗

Accuracy of the bronchoscopic DNA content analysis of non-small-cell lung carcinoma.

To assess the accuracy of the bronchoscopic DNA content analysis, samples of non-small-cell lung carcinomas (NSCLC) were investigated by means of flow cytometry. Samples were dissociated using the detergent Triton X-100. In 58 NSCLC cases, 39 (67%) had DNA aneuploid tumors. We compared the DNA indices of bronchoscopic brushing samples with 21 corresponding surgical samples. In 16 (76%) cases, DNA ploidy of both bronchoscopic and surgical samples were in concordance. In 3 (14%) cases, both bronchoscopic and surgical sample showed DNA aneuploidy, but the number of the DNA aneuploid stem cell lines was different. The cause of these differences was ascribed to the intratumor DNA heterogeneity. In 2 (10%) cases, the bronchoscopic sample showed DNA diploidy, but the surgical sample showed DNA aneuploidy. In these cases, tumor cells obtained by bronchoscopic brushing were so few that the small DNA aneuploid peak was undetectable in the DNA histogram. But the tumor DNA ploidy was evaluated correctly in 90% of 21 cases using bronchoscopic samples. Consequently, despite some drawbacks, the DNA ploidy diagnosis using bronchoscopic samples in this relatively small study, was almost as reliable as surgical samples.

Adenocarcinoma↗

The role of bronchoscopic assessment in esophageal cancer - clinical and survival analysis in 153 patients.

BACKGROUND AND PURPOSE: The diagnostic value and indications for fiberoptic bronchoscopy in the preoperative assessment of patients with esophageal cancer have not been fully studied. We evaluated the role of fiberoptic bronchoscopic examination in the stage work-up of patients with esophageal cancer and correlated the results with survival time analysis. METHODS: The medical records of 153 patients with an initial diagnosis of esophageal cancer were reviewed. Clinical data, bronchoscopic findings, treatment courses, and survival time of these patients were analyzed. RESULTS: On initial bronchoscopic examinations, distortion/compression of the normal structure and protrusion at the posterior wall of the trachea or bronchus were the most common bronchoscopic findings (35.9%). We stratified patients into 3 subgroups according to bronchoscopic findings of direct invasion, external compression, and negative findings. The symptoms of dyspnea, hoarseness, aspiration and fever were more frequent in patients with direct airway invasion compared with patients with external compression and negative bronchoscopic findings (p < 0.02). Washing and brushing cytology examinations were all negative in patients with external compression of the airway. There was a significant difference of survival time among these 3 groups of patients (direct invasion: 5.6 +/- 0.6 months; external compression: 12.3 +/- 0.9 months; negative findings: 13.3 +/- 1.1 months, p < 0.01). Direct airway invasion and original cancer stage were the most important variables for survival in the multivariate analysis, and the hazard ratio for prognosis was 2.5 (95% confidence interval [CI], 1.1-4.6) and 4.2 (95% CI, 1.5-9.3), respectively. Twelve patients (80%) with tracheoesophageal (TE) fistulae died within 3 months after diagnosis due to aspiration pneumonia and septic shock. CONCLUSIONS: The role of bronchoscopic examination in patients with esophageal cancer for preoperative evaluation resides in its ability to predict airway invasion and its impact on survival. Advanced cancer stage (stage IV) and direct airway invasion (especially TE fistula) were significantly associated with poor prognosis. These results suggest that patients suffering from dyspnea, hoarseness, aspiration and fever, implicating a high probability of airway invasion, are more likely to benefit from bronchoscopic examination and proper management in order to prevent aspiration or complications.

Bronchoscopy↗

An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes.

BACKGROUND: Endoscopes, including bronchoscopes, are the medical devices most frequently associated with outbreaks of nosocomial infections. We investigated an outbreak of Pseudomonas aeruginosa infections after bronchoscopic procedures. METHODS: Microbiologic results were reviewed to determine the rates of recovery of P. aeruginosa from bronchoalveolar-lavage specimens. Environmental samples from endoscopes and the endoscopy suite were cultured. Medical records were reviewed to identify infections in the 14 days after a bronchoscopy. RESULTS: The rate of recovery of P. aeruginosa from bronchoalveolar-lavage specimens obtained with use of endoscopy-suite bronchoscopes increased from 10.4 percent at base line to 31.0 percent during the outbreak (relative risk, 2.97; 95 percent confidence interval, 2.28 to 3.90). Cultures of samples from three bronchoscopes grew P. aeruginosa, whereas cultures of samples from the environment, instrument-cleaning machines, and gastrointestinal endoscopes did not. The three bronchoscopes had been part of a nationwide recall. A total of 414 patients underwent bronchoscopy during the outbreak, and there were 48 respiratory tract and bloodstream infections among 39 of these patients (9.4 percent). In 32 infections (66.7 percent), P. aeruginosa was confirmed as a potentially causative organism. Exposure to a potentially contaminated bronchoscope may have had a role in the death of three patients. The rate of recovery of P. aeruginosa returned to base line after the instruments were removed from service. CONCLUSIONS: This large outbreak of P. aeruginosa infections related to bronchoscopy was apparently caused by a loose biopsy-port cap in the bronchoscopes. Instrument safety and surveillance methods for bronchoscopy must be improved, and better recall procedures are needed for medical devices.

Academic Medical Centers↗

Potential nosocomial exposure to Mycobacterium tuberculosis from a bronchoscope.

OBJECTIVE: To investigate a possible nosocomial outbreak of tuberculosis (TB). DESIGN: Retrospective cohort study. SETTING: Community hospital. METHODS: We reviewed medical records, hospital infection control measures, and potential locations of nosocomial exposure. We examined the results of acid-fast bacilli (AFB) smears, cultures, and drug susceptibility testing, and performed a DNA fingerprint analysis. We observed laboratory specimen processing procedures and bronchoscope disinfection procedures. We also reviewed bronchoscopy records. RESULTS: In October 2000, three patients had bronchoscopy specimen cultures that were positive for Mycobacterium tuberculosis. Of the three, only one had clinical signs and symptoms consistent with TB and positive AFB sputum smears. The other two did not have signs and symptoms consistent with TB and had no known exposure to individuals with infectious TB. The three M. tuberculosis isolates had matching DNA fingerprints. No evidence of laboratory cross-contamination was identified. The three culture-positive specimens of M. tuberculosis were collected with the same bronchoscope within 9 days. This bronchoscope was inadequately cleaned and disinfected between patients, and the automated reprocessor used was not approved for use with the hospital bronchoscope. CONCLUSIONS: One of the bronchoscopes at this hospital was contaminated with M. tuberculosis during bronchoscopy of an AFB-smear-positive patient. Subsequent specimen contamination likely occurred because the bronchoscope had been inadequately cleaned and disinfected. Patients who subsequently underwent bronchoscopy were also potentially exposed to M. tuberculosis from this bronchoscope.

Aged↗

Advancing the tracheal tube over a flexible fiberoptic bronchoscope by a sleeve mounted on the insertion cord.

UNLABELLED: The advancement of an endotracheal tube (ETT) over a flexible fiberoptic bronchoscope (FOB) is often impeded at the glottis. This is attributed to the creation of a cleft by the difference in the outer diameter of the fiberscope and the internal diameter of the tube. We designed a conical-shaped polyvinyl chloride sleeve to fit the insertion cord. This report compares the ease of advancement of the tube over a sleeved versus a nonsleeved bronchoscope. General anesthesia was induced, and one anesthesiologist introduced the FOB (a 3.8-mm Olympus LF2). Patients were randomly assigned to undergo tracheal intubation with the regular bronchoscope (25 patients) or the sleeved bronchoscope (25 patients). The FOB was advanced to approximately 1 cm above the carina. A blinded operator advanced the tube over the bronchoscope. The ETT was successfully advanced over the nonsleeved bronchoscope into the trachea on the first attempt in 64% of the patients, whereas tracheal intubation succeeded from the first attempt in 96% of patients when the sleeved FOB was used (P < 0.05). Advancement of the ETT over the fiberscope can be facilitated by using a conically shaped sleeve mounted on the insertion cord. IMPLICATIONS: This report shows that a conical sleeve mounted on the insertion cord of a fiberoptic bronchoscope will facilitate advancing the endotracheal tube into the trachea.

Adult↗

Ventilation with rigid bronchoscopes. Evaluation of resistance by pressure drop by a proposed international standard.

UNLABELLED: The ISO 8600-2-1 draft standard concerns measuring methods for ventilation properties in rigid bronchoscopes. Two lung models were designed in accordance with this draft, one for conventional ventilation, and the other for jet-ventilation (venturi ventilation). Lung model I: An air supply was connected to a 4 liter container. The test object (bronchoscope) was exposed to air flowing out of the container through the bronchoscope, and the pressure in the container was recorded. The flow velocities were 20-60 l.min-1. Lung model II: A pressure gauge was connected to a 2 liter container. The test object was introduced into the container through an gastight opening. A pressure gas injector was connected to either the instrument port or the ventilation port of the bronchoscope. The injected pressures were 100-500 kPa. RESULTS: Study I. The pressure drop increased exponentially with increasing air flow. It also increased rapidly with decreasing diameter of the bronchoscope. Study II. The pressure in small bronchoscopes increased very fast with increasing injection pressure. Dangerous pressures (above 50 cmH2O) were reached already at 2 kg.cm-2 with the smallest bronchoscopes. We suggest that the results should be given as "pressure drop" and not as "resistance".

Airway Resistance↗

Use of the paediatric bronchoscope, flexible and rigid, in 51 European centres.

We have undertaken a survey to establish current practices and differences in the use of bronchoscopes in children in European centres. A questionnaire was sent to all 220 members of the Paediatric Assembly of the European Respiratory Society (ERS). The questions concerned the following points: indications for bronchoscopy; site of bronchoscopy; type of sedation; any oxygen supplementation during the procedure; number of procedures performed in the previous 12 months; number of procedures performed in the neonatal intensive care unit; number of bronchoalveolar lavages (BALs); side-effects during and after the procedures; and diagnostic yield. Fifty one European centres (40.8% of the European centres contacted) took part in the study. A total of 7,446 bronchoscopies had been performed in the last 12 months: 4,587 using the flexible bronchoscope and 2,859 using the rigid bronchoscope. At centres using only the fibreoptic bronchoscope, the most frequent indication was "recurrent/persistent pneumonia" (17%); at centres using only the rigid bronchoscope, it was "foreign body inhalation" (36.7%); at centres using both methods, the most frequent indication was "other indications" (23.9%). In 12 months, 2,231 BALs were performed: 1,419 in immunocompetent children and 812 in immunocompromised patients. In centres using only the fibreoptic bronchoscope, the highest yield was for "stridor" (81%); in centres using only the rigid bronchoscope, the highest yield was for "persistent atelectasis" (68%); and in centres using both instruments, it was for "foreign body inhalation" (93%). The results of the study suggest that bronchoscopy in children is now a well-established procedure at several European centres, while others are just beginning to use this technique.

Bronchoalveolar Lavage Fluid↗