Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Beclomethasone”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

A comparison of beclomethasone dipropionate aqueous nasal spray and beclomethasone dipropionate pressurized nasal spray in the management of seasonal rhinitis.

Forty patients with seasonal rhinitis and a proven sensitivity to pollens were studied for 2 weeks during the pollen season of 1982. The study was carried out according to a double-blind, double-dummy design. All patients received 100 micrograms beclomethasone dipropionate (BDP) into each nostril twice daily (400 micrograms/day) on a randomized basis, from either the aqueous nasal spray or the pressurized nasal spray (Beconase Nasal Spray). Analysis of patients' symptom scores, additional symptomatic medication and physicians' assessment indicated that both treatments were equally effective in controlling the symptoms of seasonal rhinitis. Any adverse events reported were considered to be clinically insignificant. BDP aqueous nasal spray was therefore found to be an effective and acceptable therapy in the management of seasonal rhinitis.

Administration, Intranasal↗

Health-related quality of life in moderate asthma: 400 microg hydrofluoroalkane beclomethasone dipropionate vs 800 microg chlorofluorocarbon beclomethasone dipropionate. The Study Group.

OBJECTIVE: To compare the effect of hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP; 400 microg/d) with that of chlorofluorocarbon (CFC) BDP (800 microg/d) on asthma health-related quality of life in a 12-week, parallel-group, multicenter study. BACKGROUND: HFA-BDP is a new CFC-free preparation of BDP, which was developed as a result of CFCs being phased out from metered dose inhalers. METHODS: Following 7 to 12 days of prednisone, 30 mg/d, 347 adults with moderate asthma were randomized to receive either 400 microg/d HFA-BDP, 800 microg/d CFC-BDP, or HFA placebo for 12 weeks (all other oral and inhaled steroids were withdrawn). Patients completed the Asthma Quality of Life Questionnaire (AQLQ), and clinical asthma status was measured at the end of a run-in period, at randomization (after oral steroid treatment), and at the end of the study treatment. RESULTS: Sixty-one patients withdrew, 43 due to worsening asthma (33 placebo; 5 HFA-BDP; 5 CFC-BDP). There was a deterioration in the AQLQ score (- 0.81) in the placebo group, and the difference between this and the stability observed in both the HFA-BDP group (+ 0.13) and the CFC-BDP group (- 0.03) was statistically significant (p </= 0.003). The difference between the two active treatments was not significant (p = 0.290). The calculated number of patients who needed to be treated in order to see a benefit in one patient (with the placebo as the standard treatment) was 2.4 for HFA-BDP and 3.0 for CFC-BDP. Only weak to moderate correlations were observed between changes in AQLQ scores and between asthma clinical status measures. CONCLUSION: HFA-BDP (400 microg/d) was as effective as CFC-BDP (800 microg/d) in sustaining improvements in asthma quality of life following withdrawal of 7 to 12 days of prednisone treatment in moderate asthma.

Administration, Inhalation↗

Clinically important improvements in asthma-specific quality of life, but no difference in conventional clinical indexes in patients changed from conventional beclomethasone dipropionate to approximately half the dose of extrafine beclomethasone dipropionate.

STUDY OBJECTIVE: Clinical trials of asthma treatments usually use measures of asthma control to assess efficacy. However, it is also important to determine whether patients themselves benefit from interventions. The aim of this study was to evaluate health-related quality of life in patients with asthma switched from conventional chlorofluorocarbon (CFC) beclomethasone dipropionate (BDP) to hydrofluroalkane-134a (HFA) BDP extrafine aerosol at half the daily dose. DESIGN: Open-label, 12-month, parallel-group, randomized trial. SETTING: Fifty-seven centers in four countries (United States, Belgium, the Netherlands, and United Kingdom). PATIENTS: Four hundred seventy-three patients with a > or = 6-month history of asthma, stable symptoms, and maintained on CFC-BDP, 400 to 1,600 microg/d. INTERVENTIONS: HFA-BDP, 200 to 800 microg/d (n = 354), or CFC-BDP, 400 to 1,600 microg/d (n = 119). MEASUREMENTS AND RESULTS: The Asthma Quality of Life Questionnaire (AQLQ) and pulmonary function tests were completed at months 0, 2, 4, 8, and 12. For 1 month before each visit, patients made daily recordings of symptoms, peak expiratory flow, and beta(2)-agonist use. Two hundred ninety-six patients completed the study (HFA-BDP, 83.6%; CFC-BDP, 83.2%). At month 12, improvements in overall AQLQ scores were greater in the HFA-BDP group than in the CFC-BDP group (p = 0.0024). The number of patients who need to be treated with HFA-BDP for one to have a clinically important improvement in overall asthma-specific quality of life compared with CFC-BDP was 7.3. There was no evidence of differences (p > 0.05) between treatment groups for airway caliber, symptoms, or beta(2)-agonist use. CONCLUSION: Clinically important improvements in the AQLQ score were observed at month 12 for HFA-BDP vs CFC-BDP, while conventional clinical indexes of pulmonary function and asthma control were similar in the two groups.

Adult↗

[Effect of fluticasone propionate at half dose of beclomethasone dipropionate divided twice daily and once daily in asthmatics inhaling beclomethasone dipropionate 800 micrograms daily or more].

We conducted a 12 weeks' single-arm prospective study comparing beclomethasone dipropionate (BDP), 1/2 doses of fluticasone propionate (FP) twice daily and the same dose of FP once daily in 47 asthmatics who had been inhaling BDP 800 mcg daily or more. Peak expiratory flow (PEF), FEV1, a symptom score and a frequency of beta 2 agonist were all significantly better in FP twice daily phase than BDP phase (329 vs. 306 L/min, 1.87 vs. 1.76 L, 3.6 vs. 6.0/week and 2.7 vs. 4.5 puffs/day, respectively). There was no significant difference in these endpoints between FP twice daily phase and FP once daily phase. FP twice daily produced better plumonary function and symptom relief than the double doses of BDP. Furthermore, FP twice daily could, at least in a short-term basis, safely be changed into the same doses of FP once daily.

Administration, Inhalation↗

[Effect of beclomethasone increment on airflow limitation in asthmatic children treated with high dose beclomethasone].

In order to evaluate the effect of higher dose BDP therapy (1200-1660 micrograms/day), we studied 12 asthmatic children (mean age 9.7 years-old) with airflow limitation on respiratory function test who were asymptomatic with high-dose BDP therapy (800 micrograms/day). After 4 weeks of higher dose BDP therapy, FVC, FEV1 and V50 were significantly improved, but those improvement were insufficient compared with those after salbutamol inhalation. The personal best values after salbutamol inhalation were not different in every parameter of respiratory function test between BDP 800 micrograms/day and 1200 micrograms/day. We conclude that less than 800 micrograms of daily BDP is generally adequate for prevention in most asthmatic children, because higher dose BDP therapy is no more effective on respiratory function in those treated with 800 micrograms of daily BDP, and that the best value of respiratory function after salbutamol inhalation is not always a goal of high dose BDP therapy.

Anti-Asthmatic Agents↗

Pharmacokinetic differences between chlorofluorocarbon and chlorofluorocarbon-free metered dose inhalers of beclomethasone dipropionate in adult asthmatics.

We have compared the serum pharmacokinetics of the metabolites of beclomethasone dipropionate after inhalation from chlorofluorocarbon (CFC) and hydrofluoroalkane HFA-134a (HFA) formulations in asthmatic patients. Twenty-three patients completed this open-label, randomized, single-dose, three-period crossover study. Each patient received in separate periods 200 microg or 400 microg HFA-beclomethasone dipropionate, or 400 microg CFC-beclomethasone dipropionate. Venous blood samples were collected over 24 h for the determination of beclomethasone esters and beclomethasone in the serum. Significant differences in pharmacokinetics following HFA- and CFC-beclomethasone dipropionate were observed. Following a 400 microg beclomethasone dipropionate dose, the HFA formulation gave mean maximum concentrations (Cmax) and area under the curve (AUC) values of beclomethasone esters of 1153 pg mL(-1) and 4328 pg h mL(-1), respectively, and beclomethasone Cmax and AUC values of 69 pg mL(-1) and 682 pg h mL(-1), respectively. These values were approximately 2-3-fold those seen with the CFC formulation (beclomethasone esters Cmax and AUC of 380 pg mL(-1) and 1764 pg h mL(-1), respectively; beclomethasone Cmax and AUC of 41 pg ml(-1) and 366 pg h mL(-1), respectively). Beclomethasone esters, the major component of beclomethasone dipropionate in the serum, peaked significantly earlier for the HFA formulation (0.8 h) than for the CFC formulation (2 h). Tests for dose proportionality of beclomethasone esters pharmacokinetics following HFA-beclomethasone dipropionate showed that the two hydrofluoroalkane strengths were proportional. The more rapid and greater efficiency of systemic drug delivery of the HFA formulation compared with the CFC formulation can be explained if most of each inhalation from CFC-beclomethasone dipropionate is swallowed and absorbed orally, whereas most of each inhalation from HFA-beclomethasone dipropionate is absorbed through the lungs. There is a need for comprehensive dose-response efficacy trials, with the use of the steep portion of the dose-response relationship, to evaluate the significance of these pharmacokinetic differences.

Adult↗

Adrenal effects and pharmacokinetics of CFC-free beclomethasone dipropionate: a 14-day dose-response study.

Since equivalent efficacy is achieved with lower doses of the reformulated beclomethasone dipropionate in the chlorofluorocarbon (CFC)-free propellant HFA-134a (HFA) than with the original CFC-beclomethasone dipropionate formulation, it is possible the HFA-beclomethasone dipropionate may have less safety concerns than the CFC formulation. Despite its chronic use, the steady-state pharmacokinetics of beclomethasone dipropionate has never been studied before. This double-blind study examined adrenal effects and pharmacokinetics after 14 days of dosing with HFA-beclomethasone dipropionate. Forty-three steroid-naïve asthmatic patients were randomised into 5 parallel groups and dosed every 12 h for 14 days with: HFA-placebo; 200, 400 or 800 microg day(-1) HFA-beclomethasone dipropionate; or 800 microg day(-1) CFC-beclomethasone dipropionate. After two weeks of dosing, the 24-h urinary free cortisol of all but one patient remained within the normal range, showing that all doses were well tolerated from a systemic safety perspective. The active HFA-beclomethasone dipropionate treatment groups showed a dose-related fall in 24-h urinary free cortisol. Total-beclomethasone (beclomethasone dipropionate and metabolites) pharmacokinetics after either the first dose of HFA-beclomethasone dipropionate or CFC-beclomethasone dipropionate were not substantially affected by subsequent doses. The extent of drug absorption from 800 microg day(-1) HFA-beclomethasone dipropionate and CFC-beclomethasone dipropionate was in the ratio of 1.7 : 1. A non-linear correlation between 24-h urinary free cortisol and the pharmacokinetic parameters was observed, reflecting smaller changes in 24-h urinary free cortisol than in pharmacokinetics as the dose was increased. No clinically meaningful change in the pharmacokinetics of beclomethasone dipropionate plus metabolites was seen on multiple dosing. The greater systemic availability of HFA-beclomethasone dipropionate was still associated with adrenal effects comparable with that of the CFC formulation at the same dose.

Administration, Inhalation↗

Meter-dosed, inhaled beclomethasone initiated at birth to prevent bronchopulmonary dysplasia.

OBJECTIVE: To examine the hypothesis that meter-dosed, inhaled beclomethasone administered to premature infants, beginning at birth and continuing in a tapering dosage schedule over the first 12 days of life, decreases the occurrence of bronchopulmonary dysplasia (BPD), at 36 wks corrected gestational age. DESIGN: Prospective, randomized, double-blind, placebo-controlled, small pilot clinical trial. SETTING: Tertiary care, neonatal intensive care unit. PATIENTS: Premature low birth weight neonates (<or=1300 g) followed from birth until 36 wks corrected gestational age. INTERVENTIONS: Aerosolized beclomethasone dipropionate was administered in a tapering dosage schedule beginning at birth and extended for the first 12 days of life, utilizing an aerosol spacer chamber and manual hand ventilation. In a subset of the subjects, a cosyntropin stimulation test was conducted on day 13 to ascertain potential hypothalamic-pituitary-adrenal axis suppression. Need for mechanical ventilation/continuous positive airway pressure (CPAP) and/or oxygen was assessed at 30 days of life and 36 wks corrected gestational age in addition to a number of other variables clinically relevant to the development of BPD. MEASUREMENTS AND MAIN RESULTS: In total, 19 placebo-treated and 20 beclomethasone-treated infants completed the study. Inhaled beclomethasone significantly reduced the need for supplemental oxygen at 30 days (p =.005) of life but not at 36 wks corrected gestational age (p =.243). A significantly greater proportion of infants receiving beclomethasone were extubated before 2 wks of age (p =.035), and infants receiving beclomethasone required significantly fewer days of mechanical ventilation (p =.004), but increased days of nasal CPAP as compared with the control group. Although fewer beclomethasone-treated than placebo-treated infants were administered intravenous steroids after 2 wks of age, this difference was not significant. No differences between groups were noted for the diagnoses of retinopathy of prematurity, nosocomial infection, or intraventricular hemorrhage. Similarly, no differences in the cosyntropin stimulation test were ascertained between treated and nontreated infants. No adverse effects were attributable to inhaled beclomethasone. CONCLUSIONS: In this small series, inhaled beclomethasone initiated at birth did not reduce the occurrence of BPD as defined by the continued requirement for supplemental oxygen at 36 wks corrected gestational age. However, inhaled beclomethasone did reduce the need for supplemental oxygen at 30 days of life and appeared to facilitate the transition from intubation/mechanical ventilation to less invasive nasal CPAP, as demonstrated by more frequent extubation before 2 wks of age and decreased total duration of mechanical ventilation in the beclomethasone-treated group. No adverse effects, including adrenal suppression, were noted in infants treated with inhaled beclomethasone. On the basis of the safety and apparent effectiveness of early inhaled beclomethasone in reducing the need for invasive mechanical ventilation and supplemental oxygen during the first month of life in premature infants, a larger clinical trial with greater power is warranted to ascertain if early inhaled beclomethasone can attenuate the occurrence of BPD.

Clinical Trial↗

A systemic bioactivity comparison of double-strength and regular-strength beclomethasone dipropionate MDI formulations.

BACKGROUND: The efficacy and safety of regular-strength beclomethasone dipropionate MDI prescribed within its recommended dosing range of 2 to 5 puffs three to four times daily has been well established in more than 25 years of worldwide use. A more concentrated formulation delivering 84 microg per puff was developed to provide for a more convenient twice-daily dosing regimen. OBJECTIVE: This randomized, single-blinded, positive and placebo-controlled, parallel-group, multiple-dose bioactivity study was conducted to assess the potential of a new beclomethasone dipropionate 84 microg double-strength metered-dose inhaler (Vanceril 84 microg Double Strength Inhalation Aerosol/Key) to cause hypothalamic-pituitary-adrenocortical axis suppression. METHODS: Beclomethasone dipropionate double-strength 84 microg was compared with beclomethasone dipropionate regular-strength 42 microg, orally administered prednisone, and placebo inhaler after 36 consecutive days of administration in adults with moderate asthma. Beclomethasone dipropionate double-strength was administered as 5 puffs BID and beclomethasone dipropionate regular-strength was administered as 10 puffs BID for the same total daily dose of 840 microg of beclomethasone dipropionate. Oral prednisone was administered by mouth at 10 mg once a day. The potential for hypothalamic-pituitary-adrenocortical axis suppression was evaluated by an adrenocorticotropic hormone (ACTH) stimulation test using cosyntropin 250 microg in 500 mL normal saline infused over six hours on the 36th day of treatment. Sixty-four patients completed this study. RESULTS: No clinically significant post-study findings were observed from physical examination, electrocardiogram, or clinical laboratory evaluation for any treatment group. No serious or unexpected adverse events were reported. On the 36th day of treatment, there was a significant (P < .01) difference in the plasma cortisol concentration response to cosyntropin stimulation between the prednisone and placebo treatment groups at the sixth hour of infusion. There was no significant difference in the plasma cortisol concentration response to cosyntropin stimulation between the beclomethasone dipropionate double-strength and beclomethasone dipropionate regular-strength treatment groups and the placebo group. In addition, comparison of the response between the beclomethasone dipropionate double-strength and beclomethasone dipropionate regular-strength groups showed no significant difference. CONCLUSION: Beclomethasone dipropionate, administered either via a double-strength (84 microg/puff) or regular-strength (42 microg/puff) inhaler dosed at 840 microg/day showed no evidence of hypothalamic-pituitary-adrenocortical axis suppression in adults with moderate asthma.

Administration, Inhalation↗

Differential potency of beclomethasone esters in-vitro on human T-lymphocyte cytokine production and osteoblast activity.

Beclomethasone dipropionate is an inhaled corticosteroid, used for the treatment of asthma. It is metabolised to 17-beclomethasone monopropionate, which has greater affinity for corticosteroid receptors than the parent compound, and to beclomethasone. We investigated the potency of beclomethasone dipropionate, 17-beclomethasone monopropionate and beclomethasone (compared with dexamethasone as a reference steroid) in two different human cell types, peripheral blood mononuclear cells and osteoblasts. We found that beclomethasone dipropionate, 17-beclomethasone monopropionate (EC50 10(-14) M) and beclomethasone (EC50 approx. 10(-12) M) were much more potent than dexamethasone (EC50 10(-8) M) in inhibiting interleukin-5 production by peripheral blood mononuclear cells. In contrast, beclomethasone dipropionate, 17-beclomethasone monopropionate and beclomethasone were equipotent with dexamethasone (EC50 range 0.3-1.2 x 10(-9) M) in affecting several functional assays of osteoblasts (e.g. alkaline phosphatase activity and osteocalcin synthesis). These results show that the relative bioactivities of corticosteroids vary between different human cell types, and that affinities observed in receptor binding assays are not necessarily predictive of the bioactivity in cell populations, such as peripheral blood mononuclear cells and osteoblasts, which are putatively relevant to efficacy and side effects respectively.

Administration, Topical↗

Ipratropium bromide nasal spray 0.03% and beclomethasone nasal spray alone and in combination for the treatment of rhinorrhea in perennial rhinitis.

BACKGROUND: Perennial rhinitis is a common condition that affects up to 10% to 20% of the population. Multiple agents are frequently administered since no single agent provides complete relief. Studies assessing the benefit/risk of combined therapy are important especially for newly approved agents such as ipratropium bromide nasal spray 0.03%, a topical anticholinergic agent, approved specifically for the treatment of rhinorrhea in allergic and non-allergic perennial rhinitis. OBJECTIVE: To compare the efficacy and safety of the combined use of ipratropium bromide nasal spray 0.03% (42 microg per nostril tid) and beclomethasone dipropionate nasal spray (84 microg per nostril bid) against that of either active agent alone for the treatment of rhinorrhea. DESIGN: Multicenter, 6-week, double-blind, randomized active- and placebo-controlled, parallel trial. SETTING: Allergist and general practitioner clinical practices. PATIENTS: Five hundred thirty-three patients with perennial rhinitis (279 allergic and 274 non-allergic), 8 to 75 years of age, who had at least a mild degree of severity of rhinorrhea for a minimum of 2 hours per day during the 1 week screening period as well as congestion or sneezing also of at least mild severity. INTERVENTION: Either (1) ipratropium bromide nasal spray 0.03% (42 microg per nostril tid) plus beclomethasone dipropionate nasal spray (84 microg per nostril bid), (2) ipratropium bromide nasal spray 0.03% (42 microg per nostril tid) alone, (3) beclomethasone dipropionate nasal spray (84 microg per nostril bid) alone, or (4) vehicle [matching placebo nasal spray for the ipratropium bromide (2 sprays per nostril tid)] or beclomethasone dipropionate (2 sprays per nostril bid). MAIN OUTCOME MEASURE: Severity and duration of rhinorrhea, and patient and physician global assessment of control of rhinorrhea. RESULTS: Ipratropium bromide nasal spray plus beclomethasone nasal spray was more effective than either active agent alone or vehicle in reducing the average severity and duration of rhinorrhea during 4 weeks of treatment. The advantage of ipratropium bromide plus beclomethasone nasal spray was evident by the first day of combined treatment and continued throughout the 2-week treatment period. Ipratropium bromide nasal spray had a faster onset of action during the first week of treatment and reduced the duration of rhinorrhea more than beclomethasone. Beclomethasone nasal spray was more effective in reducing the severity of congestion and sneezing than ipratropium. In patients who had not responded well to a nasal steroid prior to participation in the study based on a questionnaire administered at screening, ipratropium bromide was as effective in the steroid non-responders as steroid responders, whereas beclomethasone was more effective in steroid responders. Combined active therapy was well tolerated with no increase in adverse events over that seen previously with ipratropium bromide or beclomethasone nasal spray alone. CONCLUSIONS: The combined use of ipratropium bromide nasal spray with beclomethasone dipropionate nasal spray is more effective than either active agent for the treatment of rhinorrhea, and does not result in a potentiation of adverse drug reactions. Ipratropium bromide nasal spray 0.03% alone should be considered in patients for whom rhinorrhea is the primary symptom, and its use in combination with a nasal steroid should be considered in patients where rhinorrhea is one of the predominant symptoms, or in patients with rhinorrhea not fully responsive to other therapy.

Administration, Inhalation↗

[Glucocorticoid action of beclomethasone and its propionate ester derivatives].

In the present pharmacokinetic studies on beclomethasone dipropionate in rats, it was suggested that most of the beclomethasone-17, 21dipropionate is transformed rapidly into beclomethasone-17-monopropionate or beclomethasone in the blood or tissues and exerts the glucocorticoid effect in the form of beclomethasone. Glucocorticoid activity of beclomethasone was revealed to be 1-10% that of dexamethasone both in the hypothalamopituitaryadrenocortical suppressive effect and liver tyrosine amino transferase inducing efect in rats. Beclomethasone and its propionate derivatives were shown to have higher binding affinity to glucocorticoid receptors in rat liver, thymus and hypophysis than that of dexamethasone. The experimental results herein may serve to explain why beclomethasone and its propionate derivatives showed such a weak glucocorticoid action in comparison with that of dexamethasone. The amounts of receptor-beclomethasone (or its propionate derivatives) complexes which bound specifically to liver nuclei were only 10% or less than those of receptordexamethasone complexes and the in vivo metabolism of beclomethasone and beclomethasone-dipropionate was more rapid than that of dexamethasone.

Adrenal Cortex↗

Meter-dosed, inhaled beclomethasone attenuates bronchoalveolar oxyradical inflammation in premature infants at risk for bronchopulmonary dysplasia.

The object of this study was to examine the hypothesis that meter-dosed, inhaled beclomethasone administered to premature infants beginning at birth in a tapering dosage schedule over the first 12 days of life attenuates bronchoalveolar lining fluid oxyradical inflammation concomitant with modulation of bronchopulmonary dysplasia. The design of this study was an unblinded, uncontrolled phase I, pilot investigation of inhaled beclomethasone primarily examining safety and administration. The setting was a tertiary care neonatal intensive care unit. Intubated, premature infants were studied longitudinally to 36 weeks corrected gestational age. Meter-dosed, inhaled beclomethasone was administered in a tapering dosage schedule over the first 12 days of life. Endotracheal tube aspirates were collected on Days 2, 4, and 6 of life and assayed for various markers of bronchoalveolar lining fluid oxyradical stress. Infants were also assessed with regards to a number of relevant clinical variables and presence or absence of bronchopulmonary dysplasia at 36 weeks corrected gestational age. Although no differences in clinical outcome were apparent in comparing nine control infants with nine beclomethasone-treated infants, bronchoalveolar lining fluid from control infants exhibited evidence of apparent phospholipid peroxidation (enhanced polyunsaturated fatty acid consumption) on Day 2 of life compared to beclomethasone-treated infants. Significant differences were noted for percent arachidonic acid, total polyunsaturated fatty acids and ratio of polyunsaturated fatty acids, to saturated fatty acids. The ratio of monohydroxyl linolenic acid to native linoleic acid (a more specific marker of lipid peroxidation) as well as myeloperoxidase activity (a marker of neutrophil oxyradical stress) tended to be higher in the control group but did not achieve statistical significance for this small subject number study. No adverse reactions related to meter-dosed, inhaled beclomethasone were noted in the treatment group; most specifically no evidence of hypothalamic-pituitary-adrenal axis suppression was noted in either control or beclomethasone-treated infants. Meter-dosed, inhaled beclomethasone in the dosage schedule utilized was safe and appeared to moderate bronchoalveolar lining fluid phospholipid peroxidation. Small numbers of infants entered into the present investigation preclude comments on clinical efficacy because of the likelihood of a statistical type 2 error. However, additional investigations of inhaled beclomethasone initiated at birth in premature infants at risk for bronchopulmonary dysplasia, enrolling larger number of subjects and perhaps a higher dosage of beclomethasone, are warranted.

Administration, Inhalation↗

Comparison of the efficacy and safety of inhaled fluticasone propionate 200 micrograms/day with inhaled beclomethasone dipropionate 400 micrograms/day in mild and moderate asthma.

This study was designed to compare the efficacy and safety of a new inhaled corticosteroid, fluticasone propionate at a total daily dose of 200 micrograms, with beclomethasone dipropionate 400 micrograms/day in childhood asthma. A total of 398 asthmatic children (aged 4-19 years) were randomised to receive either fluticasone propionate 200 micrograms daily or beclomethasone dipropionate 400 micrograms daily for six weeks inhaled via a spacer device from a metered dose inhaler. During the study the patients recorded morning and evening peak expiratory flow rate (PEFR), symptom scores, and use of beta 2 agonist rescue medication. In addition, clinic visit PEFR and forced expiratory volume in one second were measured. Safety was assessed by recording all adverse events and by performing routine biochemistry and haematology screens including plasma cortisol concentration before and after treatment. For the purposes of analysis the diary card data were grouped into three periods: week 3 (days 15-21), week 6 (days 36-42), and weeks 1-6 (days 1-42). The results showed no significant difference between treatments on most efficacy parameters. However, there were significant differences in changes from baseline in favour of fluticasone propionate for % predicted morning PEFR both at week 3 (fluticasone propionate 6.1%, beclomethasone dipropionate 3.9%) and at week 6 (fluticasone propionate 8.3%, beclomethasone dipropionate 5. 9%) and % predicted evening PEFR at week 6 (fluticasone propionate 7.3%, beclomethasone dipropionate 4.9% and over weeks 1-6 (fluticasone propionate 5.5%, beclomethasone dipropionate 3.6%. Comparison between groups showed that the group receiving fluticasone propionate had a lower % of days with symptom-free exercise at week 6 (fluticasone propionate 87%, beclomethasone dipropionate 81%) and % days without rescue medication at week 6 (fluticasone propionate 87%, beclomethasone dipropionate 80%) and over weeks 1-6 (fluticasone propionate 80%, beclomethasone dipropionate 73%). Except for a higher incidence of sore throat in the fluticasone propionate group, the two treatments did not differ with regard to safety. There was no evidence of adrenal suppression with either treatment. In conclusion, fluticasone propionate 200 microgram daily ws at least as effective and as well tolerated as beclomethasone dipropionate 400 microgram daily in childhood asthma.

Administration, Inhalation↗

Distribution of therapeutic response in asthma control between oral montelukast and inhaled beclomethasone.

The distribution of responses in study populations provides a novel method of comparing the benefit of two treatments. This 6-week, randomised, placebo-controlled, double-blind study compared the effectiveness of oral montelukast with inhaled beclomethasone in chronic asthma by assessing the distribution and overlap of patient responses to therapy, as measured by a clinical outcome (asthma control days). A total of 730 adult patients with asthma, age 15-65 yrs, with a forced expiratory volume in one second (FEV1) at baseline of 50-85% of predicted and > or = 15% improvement in FEV1 after inhaled beta-agonist were enrolled. After a 2-week placebo run-in period, patients were randomly allocated to receive montelukast (10 mg once daily), inhaled beclomethasone (200 microg twice daily) or placebo. The primary end-point (per cent of asthma control days) was compared between treatments as the overlap in the response distributions. The overlap of the distribution of responses between the montelukast and beclomethasone groups was 89% for per cent asthma control days and 96% for change from baseline in FEV1. The mean (+/-SD) per cent asthma control days in the montelukast and beclomethasone groups was significantly higher than that in the placebo group (placebo 40.0+/-35.8, montelukast 50.7+/-37.1, beclomethasone 57.9+/-36.1). The mean differences between montelukast and placebo, beclomethasone and placebo, and montelukast and beclomethasone were significant. The mean per cent change (+/-SD) from baseline in FEV1 was 12.1+/-18.7 and 13.9+/-20.8 in the montelukast and beclomethasone groups, respectively, and significantly greater than that in the placebo group (6.4+/-20.1); there was no significant difference between the montelukast and beclomethasone groups in mean values or response distribution. There was also no difference among treatment groups in the frequency of adverse experiences. A comparison of the response distribution is an important approach to comparing therapies; montelukast and beclomethasone provided similar response distributions for the end-point of per cent asthma control days over a 6-week treatment period.

Acetates↗

Pulmonary function and adrenal gland suppression with incremental doses of aerosolized beclomethasone dipropionate in horses with recurrent airway obstruction.

OBJECTIVE: To evaluate clinical response, pulmonary function, and adrenal gland response to incremental doses of beclomethasone dipropionate in horses with recurrent airway obstruction. DESIGN: Crossover trial. ANIMALS: 8 horses with recurrent airway obstruction. PROCEDURE: Horses randomly assigned to 4 groups were treated twice daily via aerosol administration of placebo or 500, 1,000, or 1,500 micrograms of beclomethasone dipropionate in a crossover design with a 10-day minimum washout period. Subjective assessment of airway obstruction, serum cortisol concentration, and maximum change in pleural pressure during tidal breathing (delta Pplmax) were determined daily prior to morning drug administration, and delta Pplmax was reevaluated 15 minutes after morning drug administration. Pulmonary resistance and dynamic compliance were determined at baseline and approximately 12 hours after the final treatment. RESULTS: An immediate treatment effect was not identified. Within 24 hours, delta Pplmax and airway obstruction were lower in horses receiving beclomethasone. Onset and magnitude of response was similar among the 3 beclomethasone dose regimens. Pulmonary resistance was improved only after administration of all 3 doses of beclomethasone, whereas dynamic compliance was improved after administration of 1,000 micrograms and 1,500 micrograms of beclomethasone. Reduction in serum cortisol concentration occurred with all 3 beclomethasone dose regimens; however, the magnitude of adrenal gland suppression was greater in horses receiving 1,000 or 1,500 micrograms of beclomethasone. CONCLUSIONS AND CLINICAL RELEVANCE: Low-dose (500 micrograms) beclomethasone administration caused similar, improvement in pulmonary function, compared with high-dose beclomethasone (1,000 and 1,500 micrograms), with the exception of dynamic compliance, and caused less suppression of endogenous cortisol production.

Administration, Topical↗

Effects of early inhaled beclomethasone therapy on tracheal aspirate inflammatory mediators IL-8 and IL-1ra in ventilated preterm infants at risk for bronchopulmonary dysplasia.

We tested the hypothesis that inhaled beclomethasone therapy for prevention of bronchopulmonary dysplasia (BPD) reduces pulmonary inflammation. As part of a randomized, placebo-controlled trial, interleukin-8 (IL-8) and interleukin-1 receptor antagonist (IL-1ra) concentrations in tracheal aspirates were measured as markers of pulmonary inflammation. On study days 1 (baseline), 8, 15, and day 28 of age, samples were obtained from enrolled infants (birth weights <1,251 g, gestational age <33 week, 3 to 14 days of age) who remained ventilated and had not received systemic glucocorticoid therapy. Cytokine levels (pg/microg of free secretory component of immunoglobulin A) were compared between groups. We determined whether baseline cytokine levels modified treatment effect regarding subsequent need for systemic glucocorticoid therapy or occurrence of BPD (age 28 days). Tracheal aspirates were obtained from 161 infants (77 receiving beclomethasone, 84 receiving placebo). Median IL-8 levels were lower in beclomethasone versus placebo infants on study days 8 (82.9 vs. 209.2, P < 0.01) and 15 (37.4 vs. 77.4, P < 0.03) after controlling for antenatal glucocorticoid therapy and maternal race. Median IL-1ra levels were lower in beclomethasone versus placebo infants only on study day 8 (86.5 vs. 153.3, P < 0.01). Fewer beclomethasone infants with baseline IL-8 levels in the interquartile range required systemic glucocorticoid therapy (beclomethasone 30.6% vs. placebo 65.8%, P < 0.01) or developed BPD (beclomethasone 42.4% vs. placebo 69.4%, P < 0.03). We conclude that early-inhaled beclomethasone therapy was associated with a reduction in pulmonary inflammation after 1 week of therapy. Beclomethasone-treated infants with moderately elevated baseline IL-8 levels received less subsequent systemic glucocorticoid therapy and had a lower incidence of BPD than nontreated infants.

Administration, Inhalation↗