Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Wettability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Analogies in the two-dimensional spatial arrangement of adsorbed proteins and adhering bacteria: bovine serum albumin and Streptococcus sanguis 12.

Neither proteins nor bacteria adsorb or adhere homogeneously to a substratum surface. The final two-dimensional spatial arrangement depends on a complicated interplay between protein-protein (bacterium-bacterium) and protein (bacterium)-substratum interactions and the prevailing hydrodynamic conditions. In this paper, results are presented of two separate experiments in which bovine serum albumin (BSA) was adsorbed to, or Streptococcus sanguis 12 was deposited on substrata with different wettabilities in a search for analogies in the two-dimensional spatial arrangement of the absorbed proteins and adhering bacteria. The spatial arrangement of adsorbed BSA, visualized by transmission electron microscopy on replicas of the surface, was island-like on substrata with a low wettability and well distributed on substrata with a high wettability. The spatial arrangement of adhering S. sanguis 12 was observed directly by light microscopy during the experiment and showed a relatively large collection of near-neighbour sites on the low wettability substrata compared with the high wettability substrata. Thus, it seems that the occurrence of island-like structures in protein adsorption is concurrent with a large collection of near-neighbour sites in bacterial adhesion. As a possible explanation for the above analogy, it is suggested that proteins or bacteria are insufficiently immobilized on low wettability substrata owing to weak interaction forces, and they can move over the substratum surface to yield the two-dimensional spatial arrangements observed.

Adsorption↗

Droplet spreading on microstriped surfaces.

When a droplet of fluid is deposited on a surface with chemical and/or topological patterns, its static shape is highly dependent on the 2D distribution of the patterns. In the case of chemical stripes, three distinct spreading regimes have been observed as a function of wettability contrast between the two kind of stripes. For low wettability contrast, the droplet spreads with the same [corrected] velocity normal and parallel to the stripes [corrected] and the macroscopic contact angle is close to Cassie's contact angle. When the wettability contrast is intermediate/high, the resulting shape of the droplets is elongated. In the intermediate wettability contrast regime, an ideal situation shows stick and slip behavior of the contact line, during which the contact line jumps from one stripe to another. For a high wettability contrast, the confinement of the fluid between two chemical stripes leads to a 2D spreading.

Journal Article↗

[Effect of surface energy on wear characteristics of material combinations for the artificial hip joint].

One of the factors determining the wear of UHMWPE used as acetabular cup material is the lubricating properties of the head materials. In order to determine the lubricating properties, the wettability of Al2O3, ZrO2, CoCrMo and N-coated TiAl6V4 was established. Wettability is determined by the surface energy of the head material (solid-state material), which was measured via the contact angle of drops of fluid. As head material, appropriate rings from the Ring-on-Disc Test as per International Standard 6474 were used. The poorest wettability was associated with CoCrMo. The wettability of Al2O3 and ZrO2 was comparable. Worthy of note is the tendentially good wettability of N-coated TiAl6V4.

Biomechanical Phenomena↗

Cleaning and storage of rigid contact lenses prior to dispensing.

Most care regimens used with rigid contact lenses are composed of three solutions: 1) a "cleaning" solution; 2) a "combination" solution intended for storage, disinfection, and wetting prior to placement of rigid lenses on the eye; and 3) an in-eye "rewetting" or "lubricating" solution. While solutions (1) and (3) have only single functions, solution (2) must fulfill three fairly disparate functions. A "2-solution" care regimen is offered by Sherman Pharmaceuticals and consists of (a) a solution for cleaning, storage, and disinfection; and (b) a "wetting" solution that doubles as an in-eye lubricant. Through a more compatible and efficient matching of multiple functions within solutions, Sherman Pharmaceuticals claims to more adequately clean and prepare rigid gas-permeable (RGP) lens surfaces for wear. We investigated this strategy in terms of in-eye wettability of initially "ill-prepared" RGP lens surfaces, as measured with the in vivo contact angle technique. For this study, lenses were intentionally not cleaned of residues or solvents by the manufacturer at the end of production so as to create the well-known "first-day non-wetting syndrome." The ability of the 2-solution care regimen to even then provide wettable surfaces was compared to that of a saline control "regimen" and the most popular competing "3-solution" care system. We concluded that use of both care regimens dramatically enhanced in-eye wettability and, therefore, reduced the incidence of the "first-day non-wetting syndrome". However, the 2-solution care regimen provided significantly better wettability overall, lower incidence of functionally non-wetting surfaces, and more consistently wettable RGP lenses.

Contact Lenses↗

Clinical findings correlated with contact angles on rigid gas permeable contact lens surfaces in vivo.

Functional wettability of daily wear rigid gas permeable (RGP) contact lenses worn by 16 human subjects was monitored over a 4-month period during which wettability was also assessed with an equilibrium sessile-drop contact angle method in vivo. In all, 2,128 lens surface break-up time (LBUT) and in vivo contact angle data points were accumulated. Six hundred thirty-one associated graded evaluations of lens surface deposition and patient discomfort were also recorded. The four factors (LBUT, contact angle, deposition, and discomfort) were found to be correlated to each other, their paired values having statistically significant correlation coefficients. Contact angles were of predictive value for extremes of functional wettability, based on criterion of 20 degrees equivalent to an LBUT of 5 seconds. We confirm that surface deposition and subject discomfort are related to RGP lens wettability on the eye. In addition, the in vivo contact angle is perhaps the first contact angle measurement to be correlated with functional RGP wettability.

Contact Lenses↗

Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces.

Roughness-induced hydrophobicity, well-known from natural plant surfaces and intensively studied toward superhydrophobic surfaces, has currently been identified on microstructured titanium implant surfaces. Studies indicate that microstructuring by sandblasting and acid etching (SLA) enhances the osteogenic properties of titanium. The undesired initial hydrophobicity, however, presumably decelerates primary interactions with the aqueous biosystem. To improve the initial wettability and to retain SLA microstructure, a novel surface modification was tested. This modification differs from SLA by its preparation after acid etching, which was done under protective gas conditions following liquid instead of dry storage. We hypothesized that this modification should have increased wettability due to the prevention of contaminations that occurs during air contact. The main outcome of dynamic wettability measurements was that the novel modification shows increased surface free energy (SFE) and increased hydrophilicity with initial water contact angles of 0 degrees compared to 139.9 degrees for SLA. This hydrophilization was kept even after any drying. Reduced hydrocarbon contaminations were identified to play a possible role in altered surface thermodynamics. Such surfaces aim to retain the hydrophilicity and natural high surface energy of the Ti dioxide surface until surgical implants' insertion and are compared in this in vitro study with structural surface variants of titanium to compare roughness and chemically induced wettability.

Acids↗

In vitro comparison of soaking solutions for rigid gas-permeable contact lenses.

The comfort of rigid gas-permeable contact lenses is influenced by multiple factors, including the composition of lens material and the presence of surface deposits and/or cleaning solution residues on the lens, as well as the direct effect of lens care solutions on the lens and eye. This study was designed to examine the comparative properties of several soaking solutions with respect to wettability, viscosity, and substantivity, which are essential to maintaining patient comfort. Solutions included in this trial were: OPTI-SOAK Conditioning Solution, Boston Advance Conditioning Solution, Boston Advance Conditioning Solution, Boston Conditioning Solution, Barnes-Hind Wetting and Soaking Solution, Duracare Conditioning, and Total Cleaning, Wetting & Soaking Solution. Wettability, as indicated by mean wetting angle, was determined and OPTI-SOAK Conditioning Solution, followed by Boston Advance and Boston Conditioning solutions, respectively, yielded superior results. For viscosity, OPTI-SOAK Conditioning Solution again provided the most favorable (highest) viscosity, followed by Boston Conditioning and Barnes-Hind solutions. With regard to substantivity, a measure of sustained wettability, Boston Conditioning Solution achieved the highest measurement, followed by OPTI-SOAK and Boston Advance solutions. On the basis of this in vitro evaluation, OPTI-SOAK Conditioning Solution provided the highest potential for patient comfort based on a combination of wettability, viscosity, and substantivity.

Contact Lens Solutions↗

Effect of vitamin E addition to poly(D,L)-lactic acid on surface properties and osteoblast behaviour.

Vitamin E (Vit.E, alpha-tocoferol) is a natural agent with anti-oxidative and anti-inflammatory properties and it has been suggested that it could act as a stimulating factor for osteoblast proliferation and maturation. We produced poly(D,L)-lactic acid films enriched with Vit.E (1, 5 and 10% w/w) and investigated their surface properties using the FTIR analysis, sessile measure of wettability and serum protein adsorption, and evaluated attachment and spreading of MC-3T3 E1 murine osteoblast cells. FTIR analysis showed the presence of Vit.E on the polymer surface and Vit.E increased the polymer wettability in a concentration-dependent manner. The serum total protein adsorption increased significantly onto the 10% Vit.E P(D,L)-LA and the main protein adsorbed was albumin. The presence of albumin, considered as an anti-adhesive protein, on the surface of Vit.E enriched P(D,L)-LA films (especially 5 and 10% Vit.E) could explain, at least in part, the behaviour of MC-3T3 osteoblast cells seeded onto the polymers. Cell adhesion and spreading were strongly decreased by Vit.E (5 and 10%) in spite of the increased wettability. This reaction could be cell type-specific, independent by the surface wettability and linked to cell-specific characteristics (membrane phospholipid composition, integrins expression). Moreover a direct effect of Vit.E on cell adhesion and spreading cannot be completely excluded.

3T3 Cells↗

Integrin expression and osteopontin regulation in human fetal osteoblastic cells mediated by substratum surface characteristics.

Integrin-mediated adhesion of anchorage-dependent cells to scaffolds is a critical component of tissue engineering. We investigated integrin expression by the human fetal osteoblastic cell line, hFOB 1.19 (hFOB), as a function of substratum surface wettability. The influence of surface wettability on bone cell phenotype was also examined. Plasma-treated quartz (PTQ) and glass (PTG) (hydrophilic, contact angles of 0 degrees), octadecyltrichlorosilane-treated quartz (STQ) and glass (STG) (hydrophobic, contact angles above about 100 degrees), and tissue culture polystyrene were used for cell culture. hFOB cells cultured on hydrophilic substrata displayed well-developed actin stress fibers relative to cells on hydrophobic substrata. Western blot analysis revealed that hFOB cells cultured on hydrophobic substrata (STQ or STG) express lower levels of alphav and beta3 integrin subunits than do cells on hydrophilic substrata (PTQ or PTG). This effect was more pronounced in cells on STQ than on STG. These variations in integrin expression were lessened by extended culture time. Double- labeled integrin/actin immunofluorescence confirmed Western blot results, that is, cells cultured on PTQ displayed distinct, large plaques of alphav and beta3 subunits and integrin alphavbeta3, as well as their colocalization with actin stress fiber ends, whereas cells on STQ did not display integrin plaques after 24 h and displayed only minimal plaque formation after 3 days. Vinculin, a focal adhesion protein that mediates binding between the integrin and actin cytoskeleton, appeared in Western blots to mimic the variations of alphav and beta3 expression with respect to surface wettability. Interestingly, real-time RT-PCR analysis showed that hFOB cultured on hydrophobic substrata, which have downregulated alphav and beta3 integrin subunits, displayed greater steady state mRNA levels of osteopontin, an extracellular matrix (ECM) protein containing the Arg-Gly-Asp (RGD) integrin recognition sequence, than did cells cultured on hydrophilic substrata. Our results imply that substratum surface wettability regulates integrin-mediated bone cell adhesion and further influences the expression of bone cell-ECM complexes.

Cell Culture Techniques↗

Fibrinogen adsorption and platelet interactions on polymer membranes.

The hemocompatibility of four different wettable polymer membranes, namely Cuprophan (CE), polyether-polycarbonate (PC-PE), polysulfone (PSU), and polyetherimide (PEI), was investigated with respect to fibrinogen (Fng) adsorption and platelet adhesion/activation. In order to estimate the polar and dispersion components of the surface free energy, contact angles using water/vapor and water/n-hexadecane systems were measured. Adsorption of fibrinogen was studied using fluorescence-labeled protein. The adsorption isotherms showed that the amount and the affinity of adsorbed Fng increased with decreasing surface wettability of the membranes, which correlates with the dispersion and polar components of the surface free energy. The conformational changes of adsorbed Fng were detected by measuring the difference between monoclonal antibody binding to the conformation-sensitive epitope in the D-domain and the binding of polyclonal anti-Fng antibody. The anticipated conformational/orientational changes were greater for PEI and PSU membranes (the least wettable membranes) and negligible for the more wettable PC-PE and CE membranes. In addition, a possible relationship with the degree of platelet activation was found, showing negligible platelet adhesion on PC-PE and CE, but high platelet adhesion on PEI and PSU. Furthermore, platelets were spread to a large extent on PEI, while the formation of aggregates was observed on PSU. This may correspond to the anticipated differences in the conformational state of Fng on both membranes.

Adsorption↗

Contact angle measurement on dental implant biomaterials.

Wettability may be one of the surface factors to be considered when selecting dental implant biomaterials. Contact angles of dental implant surface preparations influence wettability and tissue adhesion. The contact angles of eight implant surface preparations were determined in this study. Contact angles were measured by a tele-microscope equipped with a protractor eyepiece. Groups 1 to 6 had a Ti6Al4V substrate. Group 1 was metallurgically polished, group 2 was blasted with 180 microns Al2O3, group 3 was blasted with 710 microns Al2O3, group 4 was hydroxyapatite (HA) blasted (125 microns), group 5 had a Calcitite HA plasma-sprayed coating, and group 6 was coated with plasma-sprayed MP-1 HA. Group 7 was metallurgically polished commercially pure (CP) titanium (grade 1), and group 8 was etched CP titanium (grade 1). Contact angles were measured 30 times for each group with distilled water and glycerol, and the determinations were statistically analyzed. Mean contact angles for groups 1 to 8 were 65.5, 65.3, 62.5, 67.9, 46.6, 81.7, 58.5, and 69.0, respectively, when tested with distilled water, and 70.7, 68.3, 81.6, 75.4, 67.1, 70.7, 62.3, and 82.5, respectively, when tested with glycerol. Analysis of variance and Tukey's Honestly Significant Difference test (p = 0.05) demonstrated significant differences between group 5 and all other groups when groups were tested with distilled water and demonstrated no significant differences between groups 5 and 7 when groups were tested with glycerol. Surface preparation of implant biomaterials affects wettability. In this study, Ti6Al4V coated with Calcitite HA had the lowest contact angles and the best wettability.

Alloys↗

Reproducibility of sterilized rubber impressions.

Impressions, dentures and other dental appliances may be contaminated with oral micro-flora or other organisms of varying pathogenicity from patient's saliva and blood. Several approaches have been tried to control the transmission of infectious organisms via dental impressions and because disinfection is less effective and has several drawbacks for impression characterization, several sterilization methods have been suggested. This study evaluated the reproducibility of rubber impressions after sterilization by different methods. Dimensional accuracy and wettability of two rubber impression materials (vinyl polysiloxane and polyether) were evaluated after sterilization by each of three well-known methods (immersion in 2% glutaraldehyde for 10 h, autoclaving and microwave radiation). Non-sterilized impressions served as control. The effect of the tray material on impression accuracy and the effect of topical surfactant on the wettability were also evaluated. One-way ANOVA with Dunnett's method was used for statistical analysis. All sterilizing methods reduced the reproducibility of rubber impressions, although not always significantly. Microwave sterilization had a small effect on both accuracy and wettability. The greater effects of the other methods could usually be overcome by using ceramic trays and by spraying impression surfaces with surfactant before pouring the gypsum mix. There was one exception: glutaraldehyde still degraded dimensional accuracy even with ceramic trays and surfactant. We conclude that a) sterilization of rubber impressions made on acrylic trays was usually associated with a degree of dimensional change; b) microwave energy seems to be a suitable technique for sterilizing rubber impressions; c) topical surfactant application helped restore wettability of sterilized impressions.

Ceramics↗

Contact activation of the plasma coagulation cascade. II. Protein adsorption to procoagulant surfaces.

A study of blood protein adsorption to procoagulant surfaces utilizing a coagulation time assay, contact angles, Wilhelmy balance tensiometry, and electron spectroscopy (ESCA) is presented. Using a new contact angle method of measuring protein adsorption termed "adsorption mapping" it was demonstrated that protein-adsorbent surfaces were inefficient activators of the intrinsic pathway of the plasma coagulation cascade whereas water-wettable, protein-repellent surfaces were efficient procoagulants. Repeated use of fully water-wettable (spreading) glass procoagulants in the coagulation time assay demonstrated that putative "activating sites" were not consumed in the coagulation of platelet-poor porcine plasma. Furthermore, these procoagulant surfaces retained water-wettable surface properties after incubation with blood proteins and saline rinse. The interpretation of these observations was that plasma and serum proteins were not adsorbed to water-wettable surfaces. However, ESCA of these same surfaces revealed the presence of a thin protein layer. Wilhelmy balance tensiometry resolved these seemingly divergent observations by demonstrating that protein was "associated" with a bound hydration layer, but not formally adsorbed through a surface dehydration or ionic interaction mechanism.

Adsorption↗

Adhesion and spreading of human skin fibroblasts on physicochemically characterized gradient surfaces.

In this study, adhesion and spreading of human skin fibroblasts on gradient surfaces of dichlorodimethylsilane (DDS) coupled to glass was investigated. Gradient surfaces were prepared by the diffusion technique and characterized by the Wilhelmy plate technique and characterized by the Wilhelmy plate technique for their wettability and by scanning x-ray photoelectron spectroscopy for their chemical surface composition. A linear relation between the gradient length, based on advancing water contact angles, and the square root of the diffusion time of DDS was observed. XPS analysis and the cellular experiments were carried out on gradient surfaces prepared using a diffusion time of 3 h. A continuously varying chemical composition with Si/O elemental surface concentration ratio being highest on the hydrophobic end of the gradient surfaces. In the presence of serum proteins, human skin fibroblasts seeded on these gradient surfaces showed a preferential adhesion onto the steepest part of the gradient, probably due to an optimal local wettability and/or local chemistry. Furthermore, it was shown that the spread area of human fibroblasts increased over the length of the gradient surface when going from the hydrophobic to the hydrophilic end. Summarizing, this study shows that the use of gradient surfaces to study cellular responses to materials surface properties, like wettability, yields more-convincing conclusions than the use of a variety of materials with different wettabilities due to the control of the specific surface chemistry of gradient surfaces.

Cell Adhesion↗

Macrophage responses to vascular stent coatings.

Diamond-like carbon (DLC) films have been proposed as potential coatings for blood-contacting devices. In this study, tetrahedral amorphous carbon (ta-C) films deposited by filtered cathodic vacuum arc system (FCVA) were compared with commercially deposited polyurethane coatings (PU) and uncoated stainless steel samples. X-ray reflectivity (XRR) measurements were performed to check density and thickness of the ta-C coatings, and contact angles measurements were used to assess surface wettability. J774 macrophages were used to assess the cell responses to the materials. Cell number, metabolic activity, and hydrogen peroxide production were measured by using biochemical assays, and the cell attachment and morphology were determined by using scanning electron microscopy and confocal laser scanning microscopy. Wettability measurements showed that of the materials, the stainless steel was the most hydrophilic, and the ta-C coatings were the most hydrophobic. Although the initial attachment and morphology did not appear to be dependent on the wettability, the cell numbers did increase with increasing wettability. Macrophages on the stainless steel samples were the most active in producing hydrogen peroxide. These data show that ta-C samples performed as well as commercial PU-coated samples in blocking cell reactions to the substrate and may prove to be effective coatings for blood-contacting materials.

Animals↗

Gravity-induced coating flows of vaginal gel formulations: in vitro experimental analysis.

Efficacy of topical microbicidal drug delivery formulations against HIV depends in part on their coating distributions and retention on vaginal epithelium. This study focused on gravity-induced coating flows of vaginal gels, and effects of formulation composition and surface wettability on coating. We hypothesized that presence of a yield stress, and surface wettability, affect coating. Experiments imaged and analyzed coating flows of gels on inclined model hydrophilic or hydrophobic surfaces. The in vitro wettability conditions bracket those believed to exist on vaginal epithelium in vivo. Six commercial vaginal gels were studied: three polyacrylic acid-based (PAA) and three cellulose-based. Our research group uses these gels in complementary human in vivo studies and other in vitro experimental analyses; this study is a first step in linking the in vivo and in vitro measurements. Coating by PAA gels was different from cellulose-based gels: the former exhibited yield stresses, which prevented initial gel shape from deforming during sliding. Coating flows of cellulose gels depended upon surface wettability. The slipping rates of the PAA gels ranked inversely with fitted yield stress values. The coating flow rates of the cellulose gels (hydrophilic surface) did not correlate with consistency index, but ranked inversely with the shear-thinning index. This study introduces a simple methodology for comparing trial formulations and relating their flows to gel constituents and physical properties. It also suggests differences in coating by current commercial gels.

Administration, Intravaginal↗

Platelet adhesion and activation on a shielded plasma gradient prepared on polyethylene.

Contact of blood with foreign materials evokes thrombogenic effects to an extent determined partly by the wettability of the biomaterials surface. Tools to study blood response towards a variation in materials wettability with minimal variation in chemistry are "gradient surfaces". However, most gradients have been prepared by diffusion or density immersion techniques, which results in a limited gradient range. Through glow discharge with partial shielding, gradients on polymers were prepared over a length of 5 cm, which facilitated studies to platelet adhesion on separate gradient sections. On polyethylene, advancing water contact angles varied from 90 degrees to 40 degrees, with a hysteresis of 30 degrees. ESCA indicated an increasing incorporation of oxygen towards the hydrophilic end. To examine the role of materials wettability on the activation of adhering platelets, sections of shielded plasma gradients were incubated in anticoagulated whole human blood. Fewer platelets adhered to the hydrophobic end, but those platelets were more activated than those on the hydrophilic end, as judged from their morphology and exposure of GpIIb-IIIa complex. However, partly related to the increased binding of platelets, the clotting activation after platelet deposition was highest on the hydrophilic end. Concluding, this new technique results in a large gradient range, which facilitates studies of formed blood elements in relation to the wettability. Platelets are more activated on hydrophobic polyethylene, while on moderate hydrophilic polyethylene more platelet adhesion and activation of the clotting system occurs.

Biocompatible Materials↗

Controllable water permeation on a poly(N-isopropylacrylamide)-modified nanostructured copper mesh film.

Water permeation is important for various applications in industry, agriculture, and daily life. However, most research mainly focuses on the static wettability on different surfaces, and the dynamic properties of the micro- and nanostructure-enhanced responsive wettability is lacking. And the relevant application research is rare, which still remains a challenge. Herein we report the temperature-controllable water permeation on a poly(N-isopropylacrylamide)-modified nanostructured copper mesh film. At low temperatures (below 25 degrees C), the film shows good water permeability because of the highly hydrophilic nature, and as a result, the water can easily penetrate through the film. At high temperatures (above 40 degrees C), it is impermeable to water because of the superhydrophobicity and the large negative capillary effect induced by the micro- and nanostructures. The excellent controllability of water permeation on this film may be convenient for use in many processes including filtration, water/oil separation, and so on. A detailed investigation indicates that the special nanostructures and the appropriate size of the microscale mesh pores not only influence the static contact angles of the mesh film, but also, more importantly, greatly improve the dynamic properties of wettability at different temperatures simultaneously, which plays a crucial role in the excellent controllability over water permeation on this film. This work may also provide interesting insight into the design of novel functional devices that are relevant to surface wettability.

Journal Article↗