Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Telescopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

The fragment R collision: W. M. Keck telescope observations of SL9.

The W. M. Keck telescope was used to observe the impact of comet Shoemaker-Levy 9 (SL9) fragment R at a wavelength of 2.3 micrometers on 21 July 1994. The data showed three outbursts. The first flash lasted about 40 seconds and was followed 1 minute after its peak by a second flash that lasted about 3 minutes. A third, longer lasting flare began 6 minutes after the first flash and lasted for 10 minutes. At its maximum brightness, the flare outshone Jupiter. The two short flashes are probably associated with the initial meteor trail and the subsequent fireball, respectively. The bright flare occurred when the impact site rotated into view. These data show that the explosion ejected material at least 1300 kilometers above the visible cloud tops. The luminosity of the impact site during the long bright flare was probably maintained by the release of gravitational potential energy, as this material fell back onto the lower atmosphere.

Atmosphere↗

Lower extremities: MR angiography with a unilateral telescopic phased-array coil.

In a comparison of conventional and magnetic resonance (MR) angiography of the lower extremities, MR imaging was performed with extremity and body coils and a unilateral six-coil telescopic phased-array coil. In one of seven volunteers, average signal-to-noise ratio was 140% higher with the latter (p < .01), only three of five stations were necessary, and examination time was decreased 50%. In the four patients, correlation in findings was 100%.

Adult↗

Diagnostic value of telescoping plugged catheters in mechanically ventilated patients with bacterial pneumonia using the Metras catheter.

A new guiding technique, Metras catheter (MC), for blindly introducing a telescoping plugged catheter (TPC) was applied to 25 mechanically ventilated patients with suspected bacterial pneumonia (BPN). Results obtained with TPC-MC were compared with those obtained with TPC using a conventional fiberoptic bronchoscope (FB) in random order. The diagnosis of BPN was definitely confirmed in 18 patients. In 7 patients, all TPC samples (MC and FB) were sterile, and a diagnosis other than BPN was proved. In the former group, colony-forming units equal to or greater than 10(3)/ml of one or more microorganisms were obtained in 61% of TPC-MC and in 66% of TPC-FB samples. These percentages increased to 64 and 71%, respectively, when 4 patients with previous antibiotic treatment were excluded from the study group. Agreement was observed between microorganisms cultured from both TPC samples in 11 of 18 patients with proved BPN (61%). Complete disparity was seen only in 2 patients (11%). Two patients developed a self-limiting hemoptysis after the TPC procedure (MC and FB, respectively). We conclude that TPC-MC is both a sensitive and specific technique for the diagnosis of BPN in mechanically ventilated patients. Because the diagnostic value of TPC-MC is similar to that of TPC-FB, we propose that the MC be used in patients receiving mechanical ventilation when the FB is not available. The simplicity and lower cost of this new system are important advantages to be considered over the fiberoptic bronchoscope.

Adult↗

Diagnostic value of quantitative cultures of bronchoalveolar lavage and telescoping plugged catheters in mechanically ventilated patients with bacterial pneumonia.

We compared the diagnostic value of quantitative cultures of bronchoalveolar lavage (BAL) and telescoping plugged catheter (TPC) samples in 34 nonimmunocompromised, mechanically ventilated (MV) patients with suspected bacterial pneumonia. A control group of seven "noninfected" MV patients was also studied. In 92% of patients with bacterial pneumonia (32 of 34), simple endotracheal aspiration samples recovered one or more microorganisms. Both BAL and TPC samples cultured colony-forming units (cfu) greater than or equal to 10(3)/ml of one or more microorganisms in 56% (19 of 34) of patients. TPC and BAL culture results agreed on 88.5% (54 of 61) of the recovered microorganisms. Sterile TPC and BAL cultures agreed on 80% (4 of 5) of the cases. Microorganisms cultured from blood samples were also cultured from BAL and TPC specimens. Culture results from the two techniques completely disagreed in only one case (3%). In the control group, one TPC and two BAL cultures yielded microorganisms in cfu greater than or equal to 10(3)/ml. Specificities of BAL and TPC were 71 and 86%, respectively, whereas specificity of endotracheal aspiration was only 14%. Both the bacterial index obtained by TPC and BAL, as well as the quantitative cultures, correlated moderately well (r = 0.78 and 0.72, respectively, p less than 0.001 for both correlations). BAL and TPC results caused changes of antibiotic treatment in 11 of 23 survivors. Neither BAL nor TPC caused complications. Our results demonstrate that BAL and TPC diagnose bacterial pneumonia in MV patients with similar accuracy. Culture results from both techniques showed excellent qualitative and reasonable quantitative agreement.

Adult↗

Diagnosis of nosocomial pneumonia in mechanically ventilated patients. Comparison of a plugged telescoping catheter with the protected specimen brush.

Protected samples of lower respiratory tract secretions processed by quantitative culture techniques are recommended to diagnose nosocomial bacterial pneumonia in intubated, mechanically ventilated patients. To evaluate the accuracy of a simple and inexpensive sampling device in this setting, we compared quantitative cultures of paired single-sheathed plugged telescoping catheter (PTC) and protected specimen brush (PSB) samples in 55 patients during 78 suspected episodes of nosocomial pneumonia. PTC and PSB samples were taken in randomized order, and patients were also randomized to have PTC samples taken "blindly" or via a fiberoptic bronchoscope. Fifteen PSB and 27 PTC samples were culture positive (greater than or equal to 10(3) cfu/ml). The two sampling procedures gave similar results in 58 (74%) episodes. A major discrepancy occurred in 20 episodes, including six false negatives of PSB in episodes of proved pneumonia, four possible false positives of PSB, and 10 possible false positives of PTC (three of which rapidly evolved towards overt pneumonia). The sensitivity and specificity of PTC were 100 and 82.2%, and those of PSB were 64.7 and 93.5%, respectively. Blinded or directed PTC samples had similar concordance with PSB samples taken via bronchoscopy. We conclude that PTC is at least as accurate as PSB in the bacteriologic diagnosis of nosocomial pneumonia in intubated patients, and that its use can result in substantial cost savings, especially when fiberoptic bronchoscopy is not otherwise indicated.

Bacterial Infections↗

Video laryngoscopy using a rigid telescope and video home system color camera. A useful office procedure.

A simple but reliable method of videotaping the larynx using the Nagashima rigid laryngoscope (telescope) and a low-cost home video color camera is described. Video laryngoscopy using this technique is a useful office procedure. The video material obtained was of high quality and of great value for teaching, voice analysis, preoperative and postoperative evaluation and documentation of various laryngeal disorders.

Laryngoscopy↗

Comparison of new telescopic video microlaryngoscopic and standard microlaryngoscopic techniques.

A new approach to microlaryngeal surgery using a specially designed video microlaryngoscope with a rigid endoscopic telescope and an attached video camera was introduced by Kantor et al in 1990. The ability to video document and perform surgery of the larynx by viewing a high-resolution television image was demonstrated. This method was recommended over the standard microscopic technique for increased visibility with greater depth of field, unimpeded instrument access, instant documentation, and superior teaching value. The authors tried this new method and the standard microscopic technique at the same sitting on a series of patients. This paper will compare these two different techniques and discuss their advantages and disadvantages. Although the new method has many advantages, the standard microscopic technique remains as a valuable method in laryngeal surgery.

Adult↗

Telescopic myringotomy and tube application.

Otoendoscopy is a new technique in otological surgery. The traditional surgery for otitis media with effusion (OME) is myringotomy and tube insertion using an operating microscope. In 45 children and five adults presenting to our department with otitis media with effusion, rigid endoscopic myringotomy and grommet tube insertion were performed using 2.7 mm diameter and 0 degree and 30 degrees angle telescopes under general anaesthesia for children and local anaesthesia for adults. The use of rigid endoscopes provides a large field of view, that is of excellent resolution and fidelity of colour as well as giving good side views. It can be performed in the out-patient clinic with little inconvenience to the patient and minimal risks.

Adult↗

Use of operating telescopes with multifocal corrective lenses.

Many older practitioners who wear spectacles with multifocal lenses for surgery work have been told that they cannot use flip-up magnifying telescopes with these owing to the difficulty of positioning them over the appropriate part of the lens and therefore must resort to normal bifocals. They thereby lose the advantages of clear vision at all distances which multifocals give. This article describes a way of overcoming this problem.

Dentistry, Operative↗

Static load test performance of a telescoping structure for an automatically deployable ROPS.

The automatically deployable ROPS was developed as part of an innovative project to provide passive protection against overturn fatality to operators of new tractors used in both low-clearance and unrestricted-clearance tasks. The primary objective of this phase of the research was to build a telescoping structure that would prove that a ROPS can be built that will (1) reliably deploy on signal, (2) rise in a sufficiently short amount of time, (3) firmly latch in its deployed position, and (4) satisfy SAE J2194 testing requirements. The two-post structure had previously been found to meet deployment time criteria, and design analyses indicated that neither the slip-fit joint nor the latch pins would fail at test loading. Four directions of static loading were applied to the structure to satisfy SAE requirements. For the series of static loading tests, the raised structure was found to maintain a protective clearance zone after all loads were applied. The structure is overly stiff and should be redesigned to increase its ability to absorb ground-impact energy. Results of dynamic tests and field upset tests are reported in companion articles. The next phase of development is to optimize the structure so that it will plastically deform and absorb energy that would otherwise be transferred to the tractor chassis.

Accidents, Occupational↗

Adaptive optics with four laser guide stars: correction of the cone effect in large telescopes.

We study the performance of an adaptive optics (AO) system with four laser guide stars (LGSs) and a natural guide star (NGS). The residual cone effect with four LGSs is obtained by a numerical simulation. This method allows the adaptive optics system to be extended toward the visible part of the spectrum without tomographic reconstruction of three-dimensional atmospheric perturbations, resolving the cone effect in the visible. Diffraction-limited images are obtained with 17-arc ms precision in median atmospheric conditions at wavelengths longer than 600 nm. The gain achievable with such a system operated on an existing AO system is studied. For comparison, performance in terms of achievable Strehl ratio is also computed for a reasonable system composed of a 40 x 40 Shack-Hartmann wave-front sensor optimized for the I band. Typical errors of a NGS wave front are computed by use of analytical formulas. With the NGS errors and the cone effect, the Strehl ratio can reach 0.45 at 1.25 microm under good-seeing conditions with the Nasmyth Adaptive Optics System (NAOS; a 14 x 14 subpupil wave-front sensor) at the Very Large Telescope and 0.8 with a 40 x 40 Shack-Hartmann wave-front sensor.

Journal Article↗

Thermal forming of glass microsheets for x-ray telescope mirror segments.

We describe a technology to mass-produce ultrathin mirror substrates for x-ray telescopes of near Wolter-I geometry. Thermal glass forming is a low-cost method to produce high-throughput, spaceborne x-ray mirrors for the 0.1-200-keV energy band. These substrates can provide the collecting area envisioned for future x-ray observatories. The glass microsheets are shaped into mirror segments at high temperature by use of a guiding mandrel, without polishing. We determine the physical properties and mechanisms that elucidate the formation process and that are crucial to improve surface quality. We develop a viscodynamic model for the glass strain as the forming proceeds to find the conditions for repeatability. Thermal forming preserves the x-ray reflectance and scattering properties of the raw glass. The imaging resolution is driven by a large wavelength figure. We discuss the sources of figure errors, and we calculate the relaxation time of surface ripples.

Journal Article↗

Houghton anastigmatic telescope containing aspheric mirrors that allows corrector position as a free parameter.

A family of catadioptric telescopes is investigated, characterzied with two-element, full-aperture afocal corrector lenses and aspherical, focusing, primary mirrors or primary-secondary mirror combination. Third-order aberration and design equation are provided for anastigmatic systems in which corrector position must be a free parameter, forcing the consideration of aspherics on the mirrored surfaces.

Journal Article↗

Numerical wave optical analysis of microlens array telescopes and comparison with experimental results.

We present a numerical wave optical model to describe the complex behavior of coaxial and decentered microlens-array-based telescopes illuminated by an incoherent angular spectrum of plane waves. With the use of this model we have been able to observe major performance differences between Galilean and Keplerian setups, which to our knowledge were not described before. The results of the simulations are compared with experimental results; the images of multimode fiber end faces are characterized with respect to transfer efficiency and intensity distribution. The results are also explained by use of modified existing analytical models.

Journal Article↗

Testing and applicability of the UPC-ZEBRA interferometer as a phasing system in segmented-mirror telescopes.

In segmented-mirror telescopes, wave-front discontinuities caused by segment misalignment are a major problem because they severely degrade optical performance. While angular misalignments are usually measured with deflectometric wave-front sensors (e.g., Shack-Hartmann sensors), a number of techniques have been proposed for the measurement of vertical discontinuities (pistons). In earlier papers we presented an instrument called UPC-ZEBRA that uses a novel interferometric technique to measure piston error during the daytime with an uncertainty of 5 nm within a 30-microm range. Here we present the most representative results obtained during the testing stage and a detailed analysis of error sources. The main modifications to be introduced for the instrument's use as a phasing calibration system are also outlined.

Journal Article↗

Broadband, static wave-front generation: Na-Ag ion-exchange phase screens and telescope emulation.

We test the statistical properties of static, atmospherelike wave fronts in glass that allow repeatable testing of astronomical adaptive optics instrumentation. The technology is mask-structured ion exchange (MSI) in glass and has significant advantages over other transmissive technologies. The screens are easy to clean, are insensitive to ambient temperature changes, and have high optical-to-near-infrared transmission. However, the effective coherence length (r0) on each of the fabricated screens is systematically too large or, equivalently, the fabricated aberrations are too weak. Despite this strong caveat, the screens appear to be quite useful: Long-exposure point-spread functions have realistic shapes, and power spectrum indices closely match those of the computer-generated wave fronts. Most significant, stacking screens with similar r0 values reduced r0 by the amount predicted by turbulence theory. The refractivity of MSI screens remains unmeasured. Finally, we present our design of an optical system that emulates the key characteristics of the Very Large Telescope, made to contain glass phase screens and to mimic an array of stars for multiconjugate adaptive optics system testing.

Journal Article↗

Wind-flow measurement over the Subaru Telescope.

Wind flows over the 8.2-m Subaru Telescope at Mauna Kea in Hawaii were analyzed with a correlation method. Three or four wind flows were detected from our measurements. Spatial and temporal resolution of the wind-flow analysis across the 8.2 m pupil were investigated experimentally. A three-dimensional spatiotemporal-frequency analysis was also applied to the wind-flow data.

Journal Article↗

Implementation of field lens arrays in beam-deflecting microlens array telescopes.

Laterally displaceable microlens array telescopes allow for variable and fast beam deflection. The generation of spurious light usually leads to a reduction of transfer efficiency with increasing displacement. We present the introduction of an array of field lenses on the back side of a recollimating microlens array that results in a reduced deflection angle dependency of transfer efficiency. A paraxial matrix formalism is used to prove the theoretical elimination of spurious light by use of a field lens array. The fabrication of well-aligned double-sided lens arrays by UV replication is discussed. Measurements of transfer efficiency with and without the use of field lens arrays are compared with the results of numerical wave-optic simulations.

Journal Article↗