Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “THROMBOELASTOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Efficacy of epsilon-aminocaproic acid in children undergoing cardiac surgery.

OBJECTIVE: To compare coagulation test results, blood loss, and blood product transfusions between patients receiving prophylactic epsilon-aminocaproic acid (EACA) and a control group matched for age, resternotomy, and surgery in children undergoing cardiac surgery. DESIGN: Nested case-control study. SETTING: University-affiliated, pediatric medical center. PARTICIPANTS: Same study period; 70 patients in EACA group and 70 patients in control group. INTERVENTIONS: Prophylactic EACA administered intravenously (load, 150 mg/kg, infusion; 30 mg/kg/h) to 70 patients at increased risk for bleeding (reoperation or Ross procedure). MEASUREMENTS AND MAIN RESULTS: Coagulation test values were measured before, during, and after cardiopulmonary bypass (CPB). Intraoperative blood loss, postoperative chest tube output, and allogenic blood product transfusions were recorded. Comparison of demographic and surgical data indicated close matching of the EACA and control groups. The EACA group ([median, 25th to 75th quartile] 15.6 mL/kg; 9.2 to 26.3 mL/kg) had less intraoperative blood loss than the control group (22.2 mL/kg; 14.3 to 36.3 mL/kg; p = 0.02). Postoperative chest tube output at 6 hours (p = 0.08), 12 hours (p = 0.07), and 24 hours (p = 0.08) was not significantly different between groups. Fewer EACA group patients required reexploration for bleeding (p < 0.05). There was no difference between groups in blood products transfused (in milliliters per kilogram or allogenic exposure per patient). Thromboelastography values (maximum amplitude [MA], whole blood clot lysis index at 30 minutes after MA) during CPB were better preserved in the EACA group. CONCLUSION: EACA reduced intraoperative blood loss but did not significantly decrease blood product transfusions. Lack of efficacy may be related to relative underdosing and should be further studied.

Adolescent↗

Oligochitosan derivatives bearing electron-deficient aromatic rings for adsorption of amitriptyline: implications for drug detoxification.

The objective of this work is the synthesis of water-soluble oligochitosan derivatives with electron deficient aromatic rings for selective and rapid adsorption of amitriptyline through pi-pi complexation. Oligochitosan was chemically modified under homogeneous conditions in dimethyl sulfoxide (DMSO). (1)H NMR, FT-IR, and MALDI-TOF were employed in characterization, confirming that the electron deficient aromatic rings were chemically attached to the backbone of oligochitosan. Thromboelastography (TEG) revealed functionalized oligochitosan derivatives did not affect blood clotting. (1)H NMR was also utilized to observe the aromatic-aromatic interaction between electron deficient aromatic rings on oligochitosan and electron rich aromatic rings in amitriptyline. The chemical shift variation of aromatic protons in oligochitosan derivatives was followed to monitor the aromatic-aromatic interaction. Upfield shift of aromatic protons on benzenesulfonyl and dinitrobenzenesulfonyl groups was observed upon the addition of amitriptyline, supporting the formation of pi-pi complexes through aromatic-aromatic interactions. Dinitrobenzenesulfonyl rings show a larger variation in chemical shift due to the presence of the electron deficient nitro groups.

Adsorption↗

The antithrombogenic potential of a polyhedral oligomeric silsesquioxane (POSS) nanocomposite.

We have developed a nanocomposite using a silica nanocomposite polyhedral oligomeric silsesquioxane (POSS) and poly(carbonate-urea)urethane (PCU) for potential use in cardiovascular bypass grafts and the microvascular component of artificial capillary beds. In this study, we sought to compare its antithrombogenicity to that of conventional polymers used in vascular bypass grafts so as to improve upon current patency rates, particularly in the microvascular setting. Using atomic force microscopy (AFM) and transmission electron microscopy (TEM), surface topography and composition were studied, respectively. The ability of the nanocomposite surface to repel both proteins and platelets in vitro was assessed using thromboelastography (TEG), fibrinogen ELISA assays, antifactor Xa assays, scanning electron microscopy (SEM), and platelet adsorption tests. TEG analysis showed a significant decrease in clot strength (one-way ANOVA, p < 0.001) and increase in clot lysis (one-way ANOVA, p < 0.0001) on the nanocomposite when compared to both poly(tetrafluoroethylene) (PTFE) and PCU. ELISA assays indicate lower adsorption of fibrinogen to the nanocomposite compared to PTFE (one-way ANOVA, p < 0.01). Interestingly, increasing the concentration of POSS nanocages within these polymers was shown to proportionately inhibit factor X activity. Platelet adsorption at 120 min was also lower compared to PTFE and PCU (two-way ANOVA, p < 0.05). SEM images showed a "speckled" morphologic pattern with Cooper grades I platelet adsorption morphology on the nanocomposite compared to PTFE with grade IV morphology. On the basis of these results, we concluded that POSS nanocomposites possess greater thromboresistance than PTFE and PCU, making it an ideal material for the construction of both bypass grafts and microvessels.

Adsorption↗

Surface modification of silica core-shell nanocapsules: biomedical implications.

In this article we present the synthesis of oil core silica shell nanocapsules with different shell thicknesses. The surface of the nanocapsules was modified with polyethyleoxide (PEO) and succinic anhydride. Two biomedical tests were then used to study the biocompatibility properties of these nanocapsules with different surface treatments, hemolysis and thromboelastography (TEG). PEO surface modification greatly reduced the damaging interactions of nanocapsules with red blood cells (RBCs) and platelets and attenuated particle size effects. It was found that the blood toxicity of charged particles increased with the acid strength on the surface. Experiments toward the assessment of detoxification of these nanocapsules in model drug overdose concentrations are currently underway.

Animals↗

Blood compatible carbon nanotubes--nano-based neoproteoglycans.

Although nanotechnology has provided a rich variety of nanomaterials (1-100 nm) for in vivo medical applications, the blood compatibility of all these nanobiomaterials is still largely unexamined. Here, we report the preparation of blood-compatible carbon nanotubes (CNTs) that potentially represent the building blocks for nanodevices having in vivo applications. Activated partial thromboplastin time (APTT) and thromboelastography (TEG) studies prove that heparinization can significantly enhance the blood compatibility of nanomaterials.

Biocompatible Materials↗

The interaction between primate blood and mouse islets induces accelerated clotting with islet destruction.

BACKGROUND: Mouse islets transplanted under the renal subcapsular space of cynomolgus monkeys are subject to a form of hyperacute rejection, the mechanism of which is unclear. As islets are in contact with whole blood at the time of transplantation, the effect of platelets and the coagulation cascade on islet destruction was assessed. METHODS: Coagulation was assessed using thromboelastography on citrated/recalcified human blood samples with freshly isolated C57/Bl6 mouse islets. A dynamic islet perifusion system was used to assess the effect of islets on blood cells and coagulation factors. Cytotoxicity was evaluated using (51)Cr labelled islets incubated with human blood and islet destruction was also evaluated using a histological grading system. Continuous PO(2) measurements were made in a static incubation system to assess the role of hypoxia in islet destruction. RESULTS: Mouse islets incubated in human blood induced accelerated coagulation and rapid consumption of platelets within 15 min. Within 1 h of incubation, 52% of mouse islets exposed to xenogeneic human blood showed features of severe damage with necrosis when compared with islets incubated in syngeneic blood. Specific lysis of the xenogeneic islets was demonstrable (Mean percentage lysis: 48%, P < 0.05 vs. control) after 4 h incubation in human blood. Oxygen levels remained constant at a level adequate to maintain islet viability in separate experiments. CONCLUSION: Mouse islets induce rapid activation of the clotting cascade and platelet consumption in vitro when exposed to human blood, which correlated with histological evidence of significant destruction demonstrable within 1 h of exposure to human or non-human primate blood. This in vitro model has features which appear to correlate with the islet destruction seen in vivo and could be a useful model for the study of the mechanisms underlying the rapid destruction of xenogeneic islets in primate recipients.

Animals↗

Dose dependent effect of aprotinin on rate of clot formation.

Forty-eight patients scheduled for elective cardiac surgery were randomly assigned to receive aprotinin in the following doses: 0.2 mg kg-1 (group A), 0.7 mg kg-1 (group B), 1 mg kg-1 (group C) and 1.4 mg kg-1 (group D). Clot formation was analysed by thromboelastography immediately after induction of anaesthesia and again 30 min after administration of aprotinin. Rate of clot formation was assessed using R (reaction time = rate of initial fibrin formation), K (clot formation time = rate of fibrin build-up and cross linking) and angle of clot formation (denoting speed at which solid clot forms). Strength of the clot was assessed by maximal amplitude of clot formation (MA) and % lysis after 30 and 60 min. Significant reduction of R and K times and increase in angle of clot formation was observed in groups A and B. This effect was not apparent in the other groups. In group D, an increase in R time was noted. These findings indicate a dose-dependent effect of aprotinin on rate of clot formation with an earlier clot formation at low doses.

Aged↗

Evaluation of the anticoagulant properties of aprotinin in vitro.

The interaction of aprotinin with normal coagulation was studied in blood samples obtained from 10 healthy subjects. Each sample was simultaneously tested in four different preparations: NaCl-treated blood: 0.03 mL 0.9% NaCl in 0.33 mL blood; aprotinin treated blood: 0.33 mL blood+aprotinin in 0.03 mL in aliquots to obtain a final blood concentration of respectively 50 KIU mL-1; 100 KIU mL-1 and 200 KIU mL-1. The coagulation process was analysed by thromboelastography. R-time, reflecting intrinsic coagulation, increased in a dose dependent manner between NaCl-treated and aprotinin-treated blood. These findings suggest a dose dependent impairment of intrinsic coagulation by aprotinin.

Anticoagulants↗

A retrospective survey of fibrinolysis as an indicator of poor outcome after cardiopulmonary bypass and a possible early sign of systemic inflammation syndrome.

A retrospective survey was undertaken of 142 adults who had undergone cardiac surgery with cardiopulmonary bypass. According to the manufacturer's instructions for thromboelastography, patients were identified as showing evidence of fibrinolysis if after coming off bypass the Ly30 index was > or =7.5%. In the 20 fibrinolytic patients, fibrinolysis was readily corrected by tranexamic acid but these patients needed more colloid and more vasopressor support than the non-fibrinolytic patients. There were three deaths, all in the fibrinolytic patients. It is possible that fibrinolysis is a marker for onset of systemic inflammation syndrome. It is recommended that, until the association between fibrinolysis and worse outcome is investigated further, patients showing fibrinolysis early after cardiopulmonary bypass should not be discharged too soon from intensive care.

Aged↗

An in vitro study comparing the effects of Hextend, Hespan, normal saline, and lactated ringer's solution on thrombelastography and the activated partial thromboplastin time.

OBJECTIVE: The purpose of this study was to determine if 6% HES 450/0.7 (hydroxyethyl starch 450/0.7) in normal saline (Hespan) and 6% HES 450/0.7 in lactated Ringer's solution (Hextend) have the same inhibition of the intrinsic coagulation pathway and platelet function. Multiple studies have suggested that 6% Hespan inhibits coagulation and increases chest tube drainage and transfusion requirements in cardiac surgical patients. There have been few studies of the effects of 6% Hextend, a relatively new plasma volume expander, on coagulation and the results thus far have been mixed. DESIGN: A prospective in vitro study. SETTING: A large academic medical center. PARTICIPANTS: Blood was collected from 30 healthy volunteers. Interventions : The blood was fractionated and diluted by 30% with Hextend, Hespan, normal saline, and lactated Ringer's solutions, with a native sample for a control. MEASUREMENTS AND MAIN RESULTS: Primary outcome measures were thromboelastography and activated partial thromboplastin time (APTT). For each of the TEG parameters, there was no difference between samples diluted with Hextend compared with Hespan (p > or = 0.112 in all cases). APTT did not differ significantly between samples diluted with Hextend compared with Hespan (p = 0.562). CONCLUSIONS: This prospective in vitro study suggests that Hextend and Hespan, hydroxyethyl starch 450/0.7 in different base solutions, exhibit the same effect on platelet function as measured by the TEG.

Adult↗

Influence of a new hydroxyethylstarch preparation (HES 130/0.4) on coagulation in cardiac surgical patients.

OBJECTIVE: To compare volume therapy with HES 130/0.4, a new hydroxyethylstarch (HES) solution with a gelatin-based fluid replacement strategy. DESIGN: Prospective, randomized, safety study. SETTING: Urban, university-affiliated hospital (single institution). PARTICIPANTS: Forty-two patients undergoing elective cardiac surgery. INTERVENTIONS: Patients were prospectively randomized into 2 groups: In group 1 (n = 21), gelatin was given perioperatively for volume support until the 1st postoperative day to keep the central venous pressure (CVP) between 10 and 14 mmHg; in group 2 (n = 21) HES 130/0.4 was administered using the same protocol as in group 1. MEASUREMENTS AND MAIN RESULTS: Standard coagulation variables and modified thromboelastography (TEG) were used. Using different activators for extrinsic and intrinsic activation and heparin inactivation by heparinase, the onset of coagulation (coagulation time), kinetics of clot formation (clot formation time), and maximum clot firmness were measured. Measurements were performed after induction of anesthesia (T0), at the end of surgery (T1), 4 hours after surgery (T2), and on the morning of the 1st postoperative day (T3). A total of 3310 +/- 810 mL of gelatin and 3070 +/- 570 mL of HES 130/0.4 were used in the 2 groups during the study period. The 2 groups did not differ with regard to postoperative bleeding or in use of packed red blood cells or fresh frozen plasma. Standard coagulation variables were similar between the 2 groups. All TEG variables were within the normal range at baseline. Coagulation time and clot formation time data were significantly elevated after surgery and in the intensive care unit, without showing specific differences between the 2 volume replacement groups. Intrinsic TEG and heparinase TEG clot formation times remained significantly higher until the end of the study period. No differences were seen between HES-treated and gelatin-treated patients. CONCLUSIONS: Volume replacement with the new HES preparation was as safe as gelatin-based volume replacement with regard to coagulation in cardiac surgical patients. HES 130/0.4 is an alternative plasma substitute to treat volume deficits.

Aged↗

Aprotinin reduces red blood cell transfusion in orthotopic liver transplantation: a prospective, randomized, double-blind study.

The effect of an aprotinin infusion on blood and blood product transfusion during adult primary orthotopic liver transplantation (OLT) was investigated in a prospective, randomized, double-blind study. Sixty-three patients were enrolled; 33 patients were administered an aprotinin regimen of a 1,000,000-KIU loading dose, followed by a 250,000-KIU/h infusion during surgery, and 30 patients were administered equivalent volumes of normal saline. Red blood cell (RBC) and blood product transfusion intraoperatively and for the first 24 hours postoperatively was by protocol. Intraoperative coagulation testing and thromboelastography (TEG; Hemoscope Corp, Skokie, IL) were performed. Intraoperative RBC transfusion was significantly less in the aprotinin group versus controls: median, 5 units (interquartile range [IQR], 3 to 9 units) versus 7 units (IQR, 5 to 16 units; P =.0016). No significant differences were found for intraoperative blood product transfusion or transfusion of RBCs or blood products in the 24-hour postoperative period. No significant differences were observed in intraoperative coagulation testing or TEG parameters. We conclude that aprotinin infusion reduces RBC transfusion requirements in OLT.

Adult↗

Aprotinin in orthotopic liver transplantation: evidence for a prohemostatic, but not a prothrombotic, effect.

Aprotinin reduces blood transfusion requirements in orthotopic liver transplantation (OLT). Concern has been voiced about the potential risk for thrombotic complications when aprotinin is used. The aim of this study is to evaluate the effects of aprotinin on the two components of the hemostatic system (coagulation and fibrinolysis) in patients undergoing OLT. As part of a larger, randomized, double-blind, placebo-controlled study, we compared coagulation (fibrinogen level, activated partial thromboplastin time [aPTT], prothrombin time, and platelet count) and fibrinolytic variables (tissue-type plasminogen activator [tPA] antigen and activity, plasminogen activator inhibitor activity, and D-dimer), as well as thromboelastography (reaction time [r], clot formation time, and maximum amplitude) in 27 patients administered either high-dose aprotinin (2 x 10(6) kallikrein inhibitor units [KIU] at induction, continuous infusion of 1 x 10(6) KIU/h, and 1 x 10(6) KIU before reperfusion; n = 10), regular-dose aprotinin (2 x 10(6) KIU at induction and continuous infusion of 0.5 x 10(6) KIU/h; n = 8), or placebo (n = 9) during OLT. Blood samples were drawn at seven standardized intraoperative times. Baseline characteristics were similar for the three groups. During the anhepatic and postreperfusion periods, fibrinolytic activity (plasma D-dimer and tPA antigen levels) was significantly lower in aprotinin-treated patients compared with the placebo group. Interestingly, coagulation times (aPTT and r) were significantly more prolonged in aprotinin-treated patients than the placebo group. No difference was seen in the incidence of perioperative thrombotic complications in the entire study population (n = 137). Aprotinin has an anticoagulant rather than a procoagulant effect. Its blood-sparing (prohemostatic) effect appears to be the overall result of a strong antifibrinolytic and a weaker anticoagulant effect. These findings argue against a prothrombotic effect of aprotinin in patients undergoing OLT.

Aprotinin↗

In vitro assessment of platelet function.

With the realization that the skin bleeding time is often an unreliable measure of platelet function, efforts have been made to identify ways to assess qualitative platelet dysfunction. Currently available techniques measure platelet adhesion, platelet aggregation, the ability of platelets to retard or stop flow through fibers, and the contribution of platelets to in vitro clot formation. Glass bead adhesion, which continues to be performed in some laboratories, is gradually being replaced by measures of platelet adhesion to filters composed of glass fibers, Dacron fibers, or collagen. In each instance, anticoagulated platelet-rich plasma or whole blood flows through the filter under a regulated pressure gradient. The amount of blood flowing through the filter versus time and/or the time to filter occlusion are measured. Recent developments in platelet aggregation have focused on whole blood and stagnation point flow aggregation techniques. Whole blood aggregation does not require blood sample processing and accommodates blood obtained from citrated vacutainer tubes. Stagnation point flow measures both platelet adhesion and aggregation and may be able to detect pathologically-enhanced platelet function. Global measures of hemostasis attempt to simultaneously evaluate the adequacy of fluid phase coagulation and platelet function. Currently available techniques include Thromboelastography, SonoClot Analyzer, Hemodyne Hemostasis Analyzer, PITT, and Hemostatometry. Although each of these technologies have been shown to provide interesting data in the research setting, the ability of any of these techniques to detect abnormal or clinical inadequate platelet function remains to be established.

Bleeding Time↗

Fibrinolytic therapy of deep vein thrombosis with continuous intravenous infusion of a recombinant tissue plasminogen activator.

Recombinant human rt-PA was administered to 22 patients with deep vein thrombosis at a dosage of 30 to 120 mg/day (0.5 to 1.76 mg/kg body weight/24 hr) over 2 to 10 days. rt-PA induced phlebographically documented substantial recanalization in 18 of 21 patients. The lowest dose of 0.5 mg/kg/24 hr tested here was thrombolytically effective, whereas a dose of 0.95 mg/kg/24 hours and more led to hemorrhagic complications and premature discontinuation of therapy in four of six patients. Blood clotting analysis did not reveal any substantial decrease in fibrinogen concentrations, whereas the euglobulin clot lysis time and thromboelastography demonstrated a systemic fibrinolytic effect. Therapy with rt-PA can thus be considered as an alternative and effective method of therapy in treatment of deep vein thrombosis. The results of this study show that even a dosage of lower than 0.5 mg/kg/24 hr might prove to be effective. Further studies would be required to show whether the fibrin specificity of rt-PA leads to a superiority of this fibrinolytic substance over the conventional thrombolytic agents, streptokinase and urokinase.

Blood Coagulation Tests↗

Platelet-dependent coagulation assays for factor VIII efficacy measurement after substitution therapy in patients with haemophilia A.

FVIII therapy for haemophilia A is safe and effective, with the problem of individually sufficient efficacy unsettled. Routine one-stage clotting assays and tests employing chromogenic substrates poorly detect individual haemostatic effects of FVIII due to artificial test conditions. In particular, the use of cell-free and diluted plasma samples neglect the crucial role of platelets for thrombin and fibrin formation. To optimize FVIII substitution therapy, we measured in 40 patients with severe to mild haemophilia A before and after FVIII substitution the FVIII activity in cell-free plasma samples using a one-stage clotting assay as well a chromogenic substrate assay and compared the data with those obtained with cell-based coagulation tests, i.e. thrombin generation in platelet-rich plasma (PRP) and thromboelastography (TEG) in samples of citrated whole blood (WB). To determine the maximum ex vivo haemostatic effect we added 1 unit/ml of FVIII to samples of PRP and WB and measured the maximum thrombin generation in the thrombin generation test (TGT) and the maximum clot firmness (MCF) in TEG. After FVIII substitution we observed a nearly linear relation between the individual FVIII activities administered to the patients and the activities measured in the plasma samples. However, data obtained with TGT and TEG revealed a high inter-individual variation and a very poor correlation to the administered FVIII activity. Actually, it could be shown that FVIII substitution yielding in a FVIII plasma activity of about 30% is sufficient to get an ex vivo haemostatic effect of more that 90% as measured by maximum thrombin generation and MCF. FVIII substitution up to a plasma activity of more than 90% did not further enhance the haemostatic effect. Our data clearly demonstrate that the haemostatic effect of FVIII is not only dependent on the activity that is measured in plasma but also depends on the interplay between coagulation and blood cells, in particular with platelets. The use of cell-based coagulation tests such us TGT or TEG may help to optimize FVIII therapy by determining the individual FVIII dosage that produces a maximum haemostatic effect.

Adult↗

Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery.

BACKGROUND: Using algorithms based on point of care coagulation tests can decrease blood loss and blood component transfusion after cardiac surgery. We wished to test the hypothesis that a management algorithm based on near-patient tests would reduce blood loss and blood component use after routine coronary artery surgery with cardiopulmonary bypass when compared with an algorithm based on routine laboratory assays or with clinical judgement. METHODS: Patients (n=102) undergoing elective coronary artery surgery with cardiac bypass were randomized into two groups. In the point of care group, the management algorithm was based on information provided by three devices, the Hepcon, thromboelastography and the PFA-100 platelet function analyser. Management in the laboratory test group depended on rapidly available laboratory clotting tests and transfusion of haemostatic blood components only if specific criteria were met. Blood loss and transfusion was compared between these two groups and with a retrospective case-control group (n=108), in which management of bleeding had been according to the clinician's discretion. RESULTS: All three groups had similar median blood losses. The transfusion of packed red blood cells (PRBCs) and blood components was greater in the clinician discretion group (P<0.05) but there was no difference in the transfusion of PRBCs and blood components between the two algorithm-guided groups. CONCLUSION: Following algorithms based on point of care tests or on structured clinical practice with standard laboratory tests does not decrease blood loss, but reduces the transfusion of PRBCs and blood components after routine cardiac surgery, when compared with clinician discretion. Cardiac surgery services should use transfusion guidelines based on laboratory-guided algorithms, and the possible benefits of point of care testing should be tested against this standard.

Aged↗

In vitro effects of local anaesthetics on the thromboelastographic profile of parturients.

BACKGROUND: Post-dural puncture headache can be an incapacitating complication of obstetric epidural analgesia/anaesthesia and early or prophylactic epidural blood patch (EBP) is one of the treatment options. Although local anaesthetic (LA) agents have been shown to have anticoagulation effects in vitro, peri-partum women are known to be hypercoagulable. We postulated that the presence of residual LA might not result in impaired haemostasis of the EBP in parturients. METHODS: Blood samples from 10 healthy term parturients were subjected to thromboelastography after the addition of four different LA (lidocaine, bupivacaine, levobupivacaine, and ropivacaine) preparations. RESULTS: There was a significant reduction in reaction (R) and coagulation (K) time (P<0.001, P<0.05) and an increase in alpha degrees angle (P<0.01) when comparing undiluted blood with the saline control group. Maximum amplitude (MA) and clot lysis (Ly30) did not change significantly despite the 50% dilution. The thromboelastographic parameters of all four LA-treated groups were no different from their saline controls and from each other. CONCLUSION: At clinical dosages, LA did not cause any hypocoagulable changes on the thromboelastographic profile of healthy parturients.

Amides↗