Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Quartz”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes.

An ultrasensitive method for the detection of the cholera toxin (CT) using electrochemical or microgravimetric quartz crystal microbalance transduction means is described. Horseradish peroxidase (HRP) and GM1-functionalized liposomes act as catalytic recognition labels for the amplified detection of the cholera toxin based on highly specific recognition of CT by the ganglioside GM1. The sensing interface consists of monoclonal antibody against the B subunit of CT that is linked to protein G, assembled as a monolayer on an Au electrode or an Au/ quartz crystal. The CT is detected by a "sandwich-type" assay on the electronic transducers, where the toxin is first bound to the anti-CT-Ab and then to the HRP-GM1-ganglioside-functionalized liposome. The enzyme-labeled liposome mediates the oxidation of 4-chloronaphthol (2) in the presence of H2O2 to form the insoluble product 3 on the electrode support or the Au/quartz crystal. The biocatalytic precipitation of 3 provides the amplification route for the detection of the CT. Formation of the insulating film of 3 on the electrode increases the interfacial electron-transfer resistance, Ret, or enhances the electrode resistance, R', parameters that are quantitatively derived by Faradaic impedance measurements and chronopotentiometric analyses, respectively. Similarly, the precipitate 3 formed on the Au/quartz crystal results in a mass increase on the transducer that is reflected by a decrease in the resonance frequency of the crystal. The methods allow the detection of the CT with an unprecedented sensitivity that corresponds to 1.0 x 10(-13) M.

Biosensing Techniques↗

Simultaneous quartz crystal microbalance impedance and electrochemical impedance measurements. Investigation into the degradation of thin polymer films.

The reproducible degradation of thin polymer films in the presence of an analyte or a reaction product of an analyte has potential applications in the development of highly sensitive, disposable biosensors. In this study, a novel combination of quartz crystal microbalance (QCM) and electrochemical impedance spectroscopy (EIS) has been developed to monitor the degradation of thin polymer films. Unlike a conventional QCM, the instrument described here allows rapid in situ measurement of quartz crystal impedance spectra. Simultaneously, classical electrochemical impedance spectra are measured in situ, affording the polymer film capacitance and bulk resistance. The combination of QCM impedance and classical EIS provides a wealth of information about the process of degradation of thin polymer films such as mass variation, swelling, delamination, viscoelasticity, and pore formation. Three different systems have been analyzed with this experimental setup; in two of the systems, polymer degradation was promoted by hydrolytic enzymes, and in the third one by a pH change. The results obtained show that the degradation of these three systems follows very different mechanisms. It is also underlined how the complementary information obtained by the two techniques allows a detailed description of the dissolution process.

Biosensing Techniques↗

Detection of folate binding protein with enhanced sensitivity using a functionalized quartz crystal microbalance sensor.

In this report, we describe the development of a quartz crystal microbalance biosensor for detection of folate binding protein (FBP). Using a simple folate-BSA conjugate adsorbed onto a Au-coated quartz sensor, a detection limit of 30 nM was achieved. Binding of FBP to the sensor surface could be blocked at concentrations as high as 1 microM with a 100-fold excess of folic acid, indicating the specificity of the folate-FBP interaction and the absence of nonspecific binding to the functionalized surface. Moreover, capture could be achieved in the presence of blood serum, making the assay amenable to the analysis of bodily fluids. Further signal enhancement based on an anti-FBP antibody and protein-A-coated gold nanosphere sandwich assay extended the detection limit to 50 pM (approximately 3 orders-of-magnitude improvement). Given the overexpression of FBP in certain malignancies and inflammatory disorders, we expect the methodology described here to be useful to detect FBP as a possible biomarker for disease diagnosis.

Antibodies↗

Hydration and energy dissipation measurements of biomolecules on a piezoelectric quartz oscillator by admittance analyses.

By using a 27-MHz piezoelectric quartz oscillator connected with a vector network analyzer, we obtained resonance frequency decreases (-DeltaFwater) and energy dissipation increases (DeltaDwater) during binding of biotinylated bovine serum albumin, biotinylated ssDNA, biotinylated dsDNA, and biotinylated pullulan to a NeutrAvidin-immobilized 27-MHz quartz crystal microbalance (QCM) plate in aqueous solution, as well as in the wet air phase (98% humidity, -DeltaFwet and DeltaDwet) and in the dry air phase (-DeltaFair and DeltaDair). -DeltaFwater indicates the total mass of the molecule, bound water, and vibrated water in aqueous solutions. -DeltaFwet indicates the total mass of the molecule and bound water. -DeltaFair simply shows the real mass of the molecule on the QCM. In terms of results, (-DeltaFwet)/(-DeltaFair) values indicated the bound water ratios per unit biomolecular mass were on the order of pullulan (2.1-2.2) > DNAs = proteins (1.4-1.6) > polystyrene (1.0). The (-DeltaFwater)/(-DeltaFair) values indicated the hydrodynamic water (bound and vibrated water) ratios per unit biomolecular mass were on the order of dsDNA (6.5) > ssDNA = pullulan (3.5-4.4) > proteins (2.4-2.5) > polystyrene (1.0). Energy dissipation parameters per unit mass in water (DeltaDwater/(-DeltaFair)) were on the order of pullulan > dsDNA > ssDNA > proteins > polystyrene. Energy dissipation in the wet and dry air phases (DeltaDwet and DeltaDair) were negligibly small, which indicates even these biomolecules act as elastic membranes in the air phase (without aqueous solution). We obtained a good linear relationship between [(-DeltaFwater)/(-DeltaFair) - 1], which is indicative of hydration and DeltaDwater/(-DeltaFair) of proteins. The aforementioned values suggest that the energy dissipation of proteins was mainly caused by hydration and that proteins themselves are elastic molecules without energy dissipation in aqueous solutions. On the contrary, plots in cases of denatured proteins, DNAs, and pullulans were relatively deviant toward the large hydration and energy dissipation from the theoretical line as perfect elastic materials, meaning that the large energy dissipation occurs because of viscoelastic properties of denatured proteins, linear DNAs, and pullulans in the water phase, in addition to energy dissipation due to the hydration of molecules. These two parameters could characterize various biomolecules with structural properties in aqueous solutions.

Air↗

Sensing of acetylcholine by a tricomponent-enzyme layered electrode using faradaic impedance spectroscopy, cyclic voltammetry, and microgravimetric quartz crystal microbalance transduction methods.

A three-enzyme layered assembly on Au electrodes or Au-quartz crystals, consisting of horseradish peroxidase, HRP, choline oxidase, ChO, and acetylcholine esterase, AChE, is used to sense acetylcholine by the HRP-mediated oxidation of 3,3',5,5'-tetramethylbenzidine, TMB (1), by H2O2, and the formation of the insoluble product (2) on the respective transducers. The analyte-substrate, acetylcholine, is hydrolyzed by AChE to choline that is oxidized by ChO and O2 to yield the respective betaine and H2O2. The amounts of generated H2O2 and the resulting insoluble product on the transducers correlate with the concentration of acetylcholine in the samples. The formation of the insoluble product (2) on electrode supports is followed by faradaic impedance spectroscopy that probes the increased interfacial electron-transfer resistance upon the formation of 2, and by cyclic voltammetry that reflects electron-transfer barriers upon the formation of the precipitate. The frequency of the Au-quartz crystal decreases as a result of the accumulation of the insoluble precipitate. The amount of insoluble product formed on the transducers is controlled by the concentration of acetylcholine and by the time interval of biocatalyzed precipitation. The generation of the insoluble product provides a means to amplify the sensing processes. Acetylcholine concentrations corresponding to 1 x 10(-5) M are easily sensed by the different transducers.

Acetylcholine↗

A quartz crystal microbalance method for rapid detection and differentiation of shiga toxins by applying a monoalkyl globobioside as the toxin ligand.

A simple globobiosyl (Gb2) ceramide mimic carrying a monoalkyl chain (C18) was applied for a monolayer Langmuir-Blodgett (L-B) technique to detect Shiga toxins (Stxs) by a quartz crystal microbalance (QCM) method. The artificial glycolipid, synthesized from penta-O-acetyl-D-galactopyranose via a conventional glycosidation pathway, was developed at the air-water surface for the formation of the monolayer film. Then, the film was transferred onto a QCM cell surface modified with alkanethiols. Upon the addition of each of Stx-1 and Stx-2, the decrease of frequency reached saturation within 45 min at a few nanogram order per quartz cell. Binding constants (Ka) estimated for each of Stx-1 and Stx-2 showed little difference between the two toxins. On the other hand, in the presence of an artificial acrylamido Gb2 copolymer as a competitive inhibitor, the two toxins showed a large difference in the binding behavior to the L-B monolayer.

Binding, Competitive↗

Quartz crystal microbalance: a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface.

The quartz crystal microbalance (QCM) is a simple, cost effective, high-resolution mass sensing technique, based upon the piezoelectric effect. As a methodology, the QCM evolved a solution measurement capability in largely analytical chemistry and electrochemistry applications due to its sensitive solution-surface interface measurement capability. The technique possesses a wide detection range. At the low mass end, it can detect monolayer surface coverage by small molecules or polymer films. At the upper end, it is capable of detecting much larger masses bound to the surface. These can be complex arrays of biopolymers and biomacromolecules, even whole cells. In addition, the QCM can provide information about the energy dissipating properties of the bound surface mass. Another important and unique feature of the technique is the ability to measure mass and energy dissipation properties of films while simultaneously carrying out electrochemistry on solution species or upon film systems bound to the upper electrode on the oscillating quartz crystal surface. These measurements can describe the course of electropolymerization of a film or can reveal ion or solute transport within a film during changes in the film environment or state, including the oxidation state for an electroactive film driven by the underlying surface potential. The past decade has witnessed an explosive growth in the application of the QCM technique to the study of a wide range of molecular systems at the solution-surface interface, in particular, biopolymer and biochemical systems. In this report, we start with a brief historical and technical overview. Then we discuss the application of the QCM technique to measurements involving micellar systems, self-assembling monolayers and their phase transition behavior, molecularly imprinted polymers, chemical sensors, films formed using the layer-by-layer assembly technique, and biopolymer films and point out the utility of the electrochemical capabilities of the technique to characterizing film properties, especially electroactive polymer films. We also describe the wide range of surface chemistries and attachment strategies used by investigators to bring about surface attachment and multi-layer interactions of these thin film systems. Next we review the wide range of recent applications of the technique to: studies of complex biochemical and biomimetic systems, the creation of protein and nucleic acid biosensors, studies of attached living cells and whole cell biosensor applications. Finally, we discuss future technical directions and applications of the QCM technique to areas such as drug discovery.

Biopolymers↗

Quartz crystal microbalance measurement of self-assembled micellar tubules of the amphiphilic decyl ester of D-tyrosine and their enzymatic polymerization.

Amphiphilic decyl derivatives of D-tyrosine self-assemble into long rodlike or tubular aggregate structures in aqueous buffered solution. In this report we demonstrate the novel use of the quartz crystal microbalance (QCM) to measure the presence in solution, and subequent enzymatic polymerization, of long rodlike monomer aggregates of the decyl ester of D-tyrosine (DEDT) as a function of their formation and increasing surface binding level as pH values increase from 3 to 7. From these data, using the Sauerbray equation to calculate the effective elastic mass surface binding of deprotonated DEDT aggregates, a pKapp of 8.3 is obtained for the DEDT alpha-NH2 group protonation-deprotonation and subsequent aggregation equilibrium. Furthermore, once aggregates are bound to the QCM surface, we initiate and subsequently monitor enzymatic polymerization of the DEDT monomers by horseradish peroxidase through the measurement of significant changes in the quartz crystal frequency and motional resistance. Following the onset of polymerization, the viscoelastic properties of the bound monomer aggregates change. A final polymerized state is achieved in which the altered physical properties of the polymerized rodlike aggregates make the solution immediately above the QCM surface-solution interface behave as a Newtonian fluid, producing a nearly pure viscosity-density energy dissipative effect on the measured crystal frequency and motional resistance values.

Biotechnology↗

Effects of quartz addition on the mechanochemical dechlorination of chlorobiphenyl by using CaO.

Grinding a mixture of 3-chlorobiphenyl (BP-Cl) and CaO with or without the addition of quartz was conducted in air by a planetary ball mill to investigate the mechanochemical dechlorination of BP-Cl. The dechlorinating reaction proceeds with an increase in grinding time, and over 99% of BP-Cl is decomposed at 360 min. Washing the ground sample with different solvents results in different products. Addition of quartz to the grinding mixture facilitates dechlorination efficiency, especially in the case of a high weight ratio of BP-Cl to CaO.

Biomechanical Phenomena↗

Scanning electrochemical microscopy in combination with piezoelectric quartz crystal impedance analysis for studying the growth and electrochemistry as well as microetching of poly(o-phenylenediamine) thin films.

The combination of scanning electrochemical microscopy (SECM) with piezoelectric quartz crystal impedance (PQCI) analysis was proposed as a novel multiparameter method for investigating the cyclic voltammetric growth of poly(o-phenylenediamine) (PoPD) thin films at Au electrodes in aqueous solutions of various pH values and the potentiostatic microetching (localized degradation) of these films in 0.10 mol/L aqueous H2SO4 for comparative examinations on polymer porosity and stability. Two potential-sweep ranges, -0.4 to 0.9 (I) and 0 to 0.9 (II) V versus SCE, and four solutions, acidic (A, 0.20 mol/L H2SO4 + 0.10 mol/L Na2SO4; B, 0.10 mol/L H2SO4 + 0.20 mol/L Na2SO4), neutral (C, 0.10 mol/L PBS + 0.20 mol/L Na2SO4, pH 7.2), and alkaline (D, 0.20 mol/L NaOH + 0.20 mol/L Na2SO4) aqueous solutions, were selected for PoPD growth. The pH increase for the polymerization solution increased the molar percentage of polyaniline-like chains in PoPD, as quantified from the current peaks at approximately 0.6 V versus a saturated calomel electrode (SCE) for the oxidation of -NH2 groups in as-prepared PoPD (grown from solutions C and D) during their redox switching in 0.10 mol/L aqueous H2SO4 for the first time. The unusual PQCI responses observed at negative potentials (potential range I) in the first several potential cycles during the cyclic voltammetric growth of PoPD in acidic and neutral solutions have been reasonably explained as being due to the precipitation/dissolution of the poorly soluble phenazinehydrine charge-transfer complexes developed during redox switching of oligomers for the first time, which brought about much less compact PoPD films and their higher degradability than those grown in the same solution but over potential range II. SECM, scanning electron microscopy (SEM), and piezoelectric quartz crystal (PQC) frequency were used to estimate the sizes of etched microscale spots. In addition, the x-, y-, or z-axis movement of a Pt microelectrode of 25-mum diameter near the PQC electrode was found to influence negligibly the PQCI responses in 1.0 mol/L aqueous Na2SO4 containing K4Fe(CN)6 up to 0.10 mol/L, and a new protocol of dynamically electrodepositing silver microwires via the chemical-lens method was proposed for examining the local mass-sensitivity distribution on the PQC surface.

Electrochemistry↗

Quantitative FT-IRRAS spectroscopic studies of the interaction of avidin with biotin on functionalized quartz surfaces.

The interaction of avidin with biotin was studied on functionalized quartz surfaces terminated with 3-aminopropyltrimethoxysilane (3-APTMS), 2,2'-(ethylenedioxy)bis(ethylenediamine) (DADOO), and fourth-generation amine-terminated polyamidoamine (G4-NH2 PAMAM) dendrimers with the use of Fourier transform infrared reflection-absorption spectroscopy (FT-IRRAS). In particular, the molecular recognition ability of these surfaces was quantified through FT-IRRAS in combination with the use of an alkyne dicobalt hexacarbonyl probe coupled with avidin. The degree of nonspecific adsorption of avidin was determined by exposure of the amine-terminated and/or biotinylated surfaces to solutions of biotin-saturated avidin. The results indicate that the biotinylated 3-APTMS layer exhibits a very low specific binding capacity for avidin (on the order of 0.15 pmol of avidin/cm2) and substantial nonspecific adsorption. Both the binding capacity and the specificity were greatly improved when the 3-APTMS layer on quartz was modified through serial chemisorption of glutaraldehyde (GA), DADOO, and/or G4-NH2 PAMAM dendrimer layers. Among these layers, the biotinylated G4-NH2 PAMAM dendrimer layer exhibited the highest capacity for avidin binding (2.02 pmol of avidin/cm2) with a specificity of approximately 90%. This effect can be attributed to the efficient packing/ordering of the binding dendrimer layer, leading to a more dense and better organized layer of biotin headgroups on the subsequent biotinylated surface.

Avidin↗

Quartz crystal microbalance studies of the contact between soft, viscoelastic solids.

Mechanical contact between a viscoelastic lens and a viscoelastic film has been probed by means of a quartz crystal microbalance operated in the impedance analysis mode. The frequency shift induced by the formation of the contact decreases with increasing film thickness because of the finite penetration depth of the acoustic shear wave. The dependence of frequency and bandwidth on film thickness and contact area is described within a sheet-contact model, which can be employed to quantitatively analyze mechanical contact in a wide range of materials problems. The model was tested by bringing a quartz crystal coated with an elastomeric gel into contact with a hemispherical cap of a similar gel. Both gels consisted of the thermoreversible gel Kraton G swollen in mineral oil. The experiments support the model well.

Biomechanical Phenomena↗

Structure of anionic phospholipid coatings on silica by dissipative quartz crystal microbalance.

The adsorption of anionic phospholipids on silica was investigated by the dissipative quartz crystal microbalance (QCM) technique. Liposomes composed of 1 mM 80:20 mol % of 1-palmitoyl-2-oleyl-sn-glycero-3-phosphatidylcholine (POPC)/phosphatidic acid, POPC/phosphatidylglycerol, or POPC/phosphatidylserine in N-(2-hydroxyethyl)piperazine-N'-(2-ethanesulfonic acid) buffer at pH 7.4 (with or without 3 mM of CaCl2) were examined. We have previously demonstrated that similar phospholipid coatings can be used in capillary electrochromatography as a stationary phase for the separation of analytes. In this work, we focus on the formation of the coatings and on the type of lipid structure formed on silica. The QCM investigation comprised qualitative results based on changes in frequency and resistance, and quantitative modeling of the obtained results. The latter was performed using the dissipative QCM, which measures the quartz crystal impedance, combined with equivalent circuit analysis. A previously developed coating and cleaning procedure for phospholipid-coated fused silica capillaries was adopted in this study, and the same silica-coated crystal was used throughout the QCM study. We will demonstrate in this work that the type of lipid structure formed on silica, that is, a rather rigid supported lipid bilayer or a viscoelastic supported vesicle layer (SVL), is highly dependent on the lipid and solvent composition. We also show for the first time that the modeling of the dissipative QCM data can be used to extract a more quantitative picture of an adsorbed SVL, because, so far, published studies have merely used the QCM data in a qualitative sense.

Adsorption↗

Quantitative analysis of tethered vesicle assemblies by quartz crystal microbalance with dissipation monitoring: Binding dynamics and bound water content.

To implement the molecular recognition properties of membrane proteins for applications including biosensors and diagnostic arrays, the construction of a biomimetic platform capable of maintaining protein structure and function is required. In this paper, we describe a tethered phospholipid vesicle assembly that overcomes the major limitations of planar supported lipid bilayers and alternative biomimetic membrane platforms and characterize it using quartz crystal microbalance with dissipation monitoring (QCM-D) and fluorescence microscopy. We provide evidence of a one-step mechanism for bilayer formation and monitor the subsequent adsorption and binding of streptavidin, vesicles, and streptavidin-coated microspheres. For all three species, we identify a critical surface density above which a significant amount of coupled interstitial water contributes to the response of the quartz resonator in a phenomenon similar to dynamic coupling due to surface roughness. A Sauerbrey-type analysis is sufficient to accurately interpret the QCM-D results for streptavidin binding if water is treated as an additional inertial mass, but viscoelastic models must be invoked for vesicle and microsphere binding. Additionally, we present evidence of vesicle flattening, possibly enhanced by a biotin-mediated membrane-membrane interaction.

Crystallization↗

Contact studies of weakly compressed PEG brushes with a quartz crystal resonator.

A quartz crystal resonator was used to characterize the contact of an elastomeric polymer membrane with a grafted poly(ethylene glycol) (PEG) brush in an aqueous environment. A two-layer model of the acoustic impedance of the system was used to measure the brush thickness before and after contact with the membrane. This model was further extended to include multiple layers, allowing characterization of other monomeric density profiles along the brush thickness. The polymer brush maintains a hydrated layer between the membrane and the quartz crystal surface, the thickness of which could be determined to within 1 nm. We show that the technique is very well suited for studying the properties of highly hydrated layers with thicknesses between 0 and 100 nm at low contact pressures corresponding to a very weak compression of the PEG brush.

Crystallization↗

Measurements of fast fluctuations of viscoelastic properties with the quartz crystal microbalance.

The quartz crystal microbalance (QCM) was used to study the variability of acoustic properties of living cells on the sub-second time scale. A confluent cell layer of rat cardiac myocytes was grown onto the electrode of quartz crystal resonator. The cell layer performed periodic, synchronous contractions at a rate of about 1.5 Hz. In order to monitor these rather fast changes in the state of the cells, the QCM was operated in a "fast mode", which allows sampling of the shift of the resonance frequency and energy dissipation with a rate of up to 100 Hz. The contractions were clearly reflected in periodic variations of the resonance frequency and the bandwidth. The rate of the contractions, in particular, could be easily detected in this way. Building on the rate of contraction, the setup can be used to monitor the response of the cell layer to heart stimulating drugs like isoproterenol. Depending on the concentration of isoproterenol, the beat rate was found to increase by up to a factor of two.

Biofilms↗

Wireless excitation of quartz crystals immersed in an aqueous fluid.

A novel toroidal coil geometry able to induce remote acoustic waves in quartz crystals has been evaluated for the development of (bio)sensors. Remote acoustic generation in air was obtained for two alternative toroidal coils, with corresponding electrical impedance changes of 40 Omega for a PDMS- and 140 Omega for a ferrite-supported toroid respectively. It was found that the range of remote acoustic generation relative to the spiral coil standard was much improved, increasing the axial separation of their resonant sensing element from 0.1 mm to 20 mm, thereby allowing electromagnetic wave penetration across glass walls and fluid media to be utilised. Consideration of the transduction mechanism, along with measured cyclic changes in acoustic signal as a function of rotation, indicated that the large PDMS toroidal coil produced an asymmetric electric field. It was shown for the first time that a quartz crystal blank fully immersed in an aqueous fluid could support chemically sensitive shear acoustic standing waves that were excited and detected remotely. A signal to noise ratio of 30 ratio 1 at 20.13 MHz was achieved by placing a ferrite supported toroidal coil on the lower side of a glass beaker containing a 12 x 0.25 mm AT crystal blank and 1 mL of water. This discovery allows wireless shear acoustic wave measurements to be performed with total separation between the electronic detection system and assays undertaken in fluidic systems.

Acoustics↗