Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding.

Retrieval studies suggest that the loosening process of the cemented femoral components of total hip arthroplasties is initiated by failure of the bond between the prosthesis and the cement mantle. Finite element (FE) analyses have demonstrated that stem-cement debonding has stress-producing effects in the cement mantle. High interface friction, which corresponds to a degree of surface roughness, reduces these stresses. In experiments, however, debonded rough stems produced more cement damage than polished ones; in the Swedish Hip Register polished stems were clinically superior with respect to stems with a mat surface finish. The purpose of the present study was to investigate this contradiction. For this purpose, global and local FE models with debonded stem-cement interfaces were used to study the effects of prosthesis surface roughness on the cement stresses on a global scale and microscale, respectively. Similar to earlier numerical studies, the global FE model predicted that an increased surface roughness of the stem reduced the stresses in the cement mantle. The local model provided insight in the load-transfer mechanism on a microscale and could explain the experimental and clinical findings. The local cement peak stresses around the asperities of the surface roughness profile increased with increasing surface roughness and decreased again beyond a particular roughness value. Cement abrasion is caused by localized stresses in combination with micromotion. From this study it can be concluded that to minimize cement abrasion, debonded stems should either have a polished microstructure to minimize the local cement stresses or have a profiled macrostructure to minimize micromotions at the stem-cement interface.

Arthroplasty, Replacement, Hip↗

Early failure of an autologous pericardium aortic heart valve (ATCV) prosthesis.

BACKGROUND AND AIMS OF THE STUDY: The risk of reoperation due to calcific degeneration is the most important drawback of biological heart valves compared with mechanical prostheses. Concepts to mitigate calcification have been tested experimentally and clinically, but none has proven completely to prevent degeneration. METHODS: Renewed interest has involved the use of autologous pericardium for intraoperative construction of autologous aortic valves (ATCV). RESULTS: Of 10 ATCV implanted between 1994 and 1996, one was removed from an 84-year-old female 27 months after implantation because of severe valvular insufficiency. Eight months earlier, a broken spring of the stent system was detected radiographically, with normal valvular competence at echocardiography. Valve dysfunction was due to shrinkage of one leaflet. Measurement of tissue calcium by atomic absorption spectroscopy showed high levels in the shrunken leaflet compared with two intact leaflets (42.82 versus 0.51 and 2.42 mg Ca2+/g). Histology and immunohistology demonstrated extensive fiber degeneration without inflammation or immune reactions in the destroyed leaflet, and moderate fiber degeneration in intact leaflets. Scanning electron microscopy showed smooth surfaces in the normal leaflet and exposure of collagen in the degenerated leaflet in association with calcium deposition. CONCLUSIONS: In contrast to the outcome in animal studies, intraoperative tanning did not prevent tissue shrinkage in this case. Leaflet malfunction was associated with calcification. At present, the clinical use of valves constructed from autologous pericardium can not be recommended.

Aged↗

Early elective conversion for failing EVAR.

BACKGROUND: The aim of the study was to assess the long term results of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms at the Helsinki University Central Hospital 1996-2004 with a special emphasis on elective conversion procedures and their outcome. METHODS: Treatment results and follow-up data of all 110 elective EVAR procedures performed in our institution were gathered prospectively and evaluated. RESULTS: Conversion to open surgery was performed in 23 (21%) of 110 EVAR patients. 30-day mortality after elective stent-graft deployment was 0% as it was also on elective conversions (n = 20). Secondary elective conversions were performed due to infection in two and after failing stent-graft treatment in 12 patients. Six of the conversions were performed primarily. Three urgent conversions (3% overall) were performed: two of these patients died, corresponding to an overall mortality of 9% (2/23) in all conversions. Five-year aneurysm-related mortality after EVAR among patients with elective conversion was 0% and 19% in patients with secondary procedures other than elective conversions. CONCLUSIONS: As conversions seem to be hazardous only when performed in urgent situations, elective conversion could be an alternative treatment method in complex failing first-generation stent-grafts as it may reduce mortality associated with urgent conversions or repeated attempts to maintain graft integrity with endovascular procedures.

Aged↗

Girdlestone resection arthroplasty following failed surgical procedures.

We retrospectively reviewed 43 patients who had undergone Girdlestone resection arthroplasty of the hip after failed total hip replacement or failed operations for hip trauma between 1990 and 2002. The indications were peri-prosthetic infection, aseptic loosening, recurrent dislocation and failed internal fixation for femoral neck fractures. Twenty-five patients died with an overall mortality of 58%. Out of 18 survivors, four patients had a prosthesis re-implanted and were excluded from the study. In 14 surviving patients followed-up for a mean of 44.5 months, the average age was 76 years. Adequate pain relief was achieved in 12 patients and infection was controlled in all. They all needed walking aids. The overall patient satisfaction was 10/14. We observed that patients who had had resection arthroplasty following failed operations for hip trauma had a higher mortality than those for failed total hip arthroplasty. Girdlestone arthroplasty is still a viable option to salvage irretrievably failed hips presenting technical difficulties in medically compromised patients. Limb shortening and the inevitable need for a walking aid should be clearly explained to patients during the consenting process in order to avoid unrealistic expectations.

Aged↗

Failure of a knee prosthesis accelerated by shedding of beads from the porous metal surface.

A 61-year-old man who received a porous-metal-coated knee implant returned eight months later with chronic synovitis, instability, and loosening of his artificial joint. Subsequently, metal beads were detected in the joint space and soft tissues and were also embedded in the articulating surface of the tibial component. There was scoring of the tibial surface, and polyethylene wear particles were noted in the synovial and fibroconnective-tissue membranes, which had formed beneath the tibial component. Many particles were seen inside giant cells and macrophages. Failure in this case was probably accelerated by the granulomatous response in the soft tissue to wear particles. There was osteolysis rather than new bone growth at the interface with the tibial component. Analysis indicated that poor bead-bonding strength may have initiated the problem. Careful appraisal of the outcome from use of beaded porous-metal-coated devices and assurance of their adequate bonding strength are essential for further progress.

Foreign Bodies↗

Amputation after failed total knee arthroplasty.

From 1983 to 1992, nine above-knee amputations were performed in eight patients for complications after total knee arthroplasty. The mean time from the initial knee replacement to amputation was 9.7 years. The average age of the four men and four women was 72 years. Eight knees had chronic infection and one had intractable pain after four revision attempts for aseptic loosening. Most patients had two revision arthroplasties after the original implant. In this series, the common factors that lead to amputation were multiple revision attempts in the presence of chronic infection, severe bone loss, and intractable pain. Earlier consideration of arthrodesis rather than multiple revision attempts is recommended to avoid such a poor outcome.

Aged↗

[Serum cobalt and serum chromium level in 2 patients with chronic renal failure after total hip prosthesis implantation with metal-metal gliding contact].

PURPOSE: The influence of chronic renal failure on serum cobalt and serum chromium in two patients with metal-on-metal bearing (Metasul) and cementless total hip arthroplasty (Alloclassic) is investigated. METHODS: Serum cobalt and serum chronium levels were determined in the postoperative course using atomic absorption spectrometry. RESULTS: Maximum values are found to be more than 100-fold elevated when compared to the reported median serum cobalt concentrations in patients with the same prosthesis type and no known renal disease. CONCLUSION: Chronic renal failure seems to be responsible for the marked elevation of serum cobalt and serum chromium. CLINICAL RELEVANCE: Despite evidence of adverse health reactions, a possible effect of long-term cobalt and chromium loading cannot be neglected. In our opinion, metal-on-metal bearings in THA should not be inserted in patients with chronic renal failure. Follow-up investigations (serum cobalt, serum chromium, serum creatinine, BUN, echocardiography) should be performed at short intervals.

Adult↗

Wear particles.

Particulate and ionic debris resulting from in vivo degradation of total joint replacement components are recognized as major factors limiting the longevity of the joint reconstruction and the overall success of the procedure. Particulate and ionic wear and corrosion debris have been associated with a locally aggressive biologic response that can lead to synovitis, periprosthetic bone loss, and aseptic loosening of the implants. Furthermore, concerns exist regarding the systemic dissemination of prosthetic debris, including potential effects resulting from end-organ retention. The long-term success of total disc arthroplasty may well depend, at least in part, on the ability to minimize implant debris generation and the subsequent local and systemic response.

Arthroplasty, Replacement↗

Long-term clinical performance of Sorin tilting-disc mechanical prostheses in the mitral and aortic position.

OBJECTIVE: Analyzing the long term performance of sorin tilting-disc mechanical prostheses. EXPERIMENTAL DESIGN: Retrospective patient-oriented study. The total follow-up was 460.2 patient-years. Follow-up data was obtained from the patients themselves or from their relatives. SETTING: Department of Cardiovascular Surgery in a general community hospital. PATIENTS: Seventy four patients undergoing valve replacement with Sorin tilting-disc mechanical prostheses between May, 1982 and July 1991. INTERVENTIONS: Thirty one of those patients underwent isolated mitral valve replacement (MVR) and 43 isolated aortic valve replacement (AVR). MEASURES: The incidence of the different complications is expressed as linearized rates. Actuarial analysis was performed with the Kaplan-Meier method. RESULTS: Linearized rates for MVR and AVR for the different complications (events per 100 patient-years) were, respectively: Late mortality: 4.5 +/- 1.6 and 1.8 +/- 0.8; Thromboembolism: 3.4 +/- 1.4 and 1.1 +/- 0.6; Anticoagulant-related hemorrhage: 2.8 +/- 1.3 and 0.3 +/- 0.3; Prosthetic endocarditis: 1.1 +/- 0.8 and 0.7 +/- 0.5; Non-structural dysfunction: 0.5 +/- 0.5 and 1.1 +/- 0.6; Reoperation: 1.1 +/- 0.8 and 0.3 +/- 0.3. Actuarial probabilities of freedom from the different complications were, respectively, at 13 years follow-up for MVR and 12 years follow-up for AVR, the following: Late mortality: 45.7 +/- 12.4% and 70.3 +/- 7.9%; Thromboembolism: 74.6 +/- 10.8% and 90.7 +/- 5.1%; Anticoagulant-related hemorrhage: 79.4 +/- 11.6% and 97.3 +/- 2.7%; Prosthetic endocarditis: 92.7 +/- 4.9% and 91.2 +/- 6.4%; Non-structural dysfunction: 95.6 +/- 4.3% and 88.2 +/- 6.6%; Reoperation: 83.6 +/- 11.8% and 97.3 +/- 2.7%. All valve-related mortality and morbidity: 42.2 +/- 11.0% and 56.7 +/- 8.6%. There was no instances of prosthetic structural failure. CONCLUSIONS: The Sorin mechanical prosthesis presents a good durability and its performance in the long term is comparable to other tilting-disc devices of the same generation.

Actuarial Analysis↗

Revision of failed total shoulder arthroplasty.

The complexity of revision shoulder surgery remains a supreme challenge for the experienced shoulder surgeon. The difficulty of surgery is often accompanied by unpredictable patient cooperation during the postoperative rehabilitation program. Recognition of the problems associated with the failed shoulder arthroplasty is necessary for successful revision surgery. Numerous reconstructive techniques are necessary for restoration of soft tissue and bony deficiencies. Component revision is often necessary in treating component loosening or glenohumeral instability. Glenoid component removal may be necessary in the presence of severe rotator cuff insufficiency or marked glenoid bone deficiency. Humeral revision is most predictably treated with methylmethacrylate fixation. Humeral fractures associated with humeral arthroplasty are most successfully treated surgically, except in those instances where a long oblique or spiral fracture is not associated with prosthetic loosening. Deep infection is most predictably treated by extensive debridement, parenteral antibiotics, and delayed exchange of the components. The success of revision shoulder arthroplasty is often unpredictable, with 60% of revisions offering satisfactory pain relief and restoration of function. Critical to the success of revision arthroplasty is the status of the soft tissues, particularly the anterior deltoid and rotator cuff.

Anti-Bacterial Agents↗

Accuracy of disincorporation for identification of vascular graft infection.

OBJECTIVE: The presence or absence of prosthetic graft incorporation with surrounding tissue was assessed relative to bacterial culture results, using enhanced microbiologic culture techniques. DESIGN: Criterion standard. SETTING: University and Veterans Affairs hospital. PATIENTS: Prosthetic samples were removed from 113 aortofemoral, extra-anatomic, infrainguinal, and hemoaccess sites at the time of vascular reoperative surgery. Harvested grafts were sonicated. Density of organisms was determined by quantitative culture. MAIN OUTCOME MEASURES: The culture result was predicted from the status of prosthetic incorporation or disincorporation as determined at surgery. For purposes of this study, any bacterial growth represented graft infection. RESULTS: Cultures positive for bacteria were obtained from 31 sites; cultures with no growth, from 82. Thirty-one of the 113 sites were disincorporated, of which 23 yielded cultures positive for bacteria, and eight, no growth. The remaining 82 sites were well incorporated, of which 74 yielded cultures negative for bacteria, and eight, bacterial growth. Sixteen (14%) incorrect predictions were noted. The concurrence of disincorporation and a culture positive for bacteria relative to all culture-positive grafts (sensitivity) was 74%. The concurrence of incorporation and cultures negative for bacteria relative to all culture-negative grafts (specificity) was 90% in prostheses implanted for longer than 2 weeks; in prostheses implanted for longer than 12 weeks, specificity was 97%. CONCLUSIONS: The surgical finding of incorporation or disincorporation accurately predicted the culture result in 89% of the sites. Disincorporation correlated with presence of bacteria in 71%; incorporation reliably excluded the presence of bacteria in 97%.

Aorta↗

Revision hip arthroplasty in patients with a history of previous malignancy.

BACKGROUND AND OBJECTIVES: The potential association between implants and malignancy has been discussed in the literature, but never as a cause of loosening of joint arthroplasty. METHODS: The records of all patients who underwent revision arthroplasty at our institution between 1992 and 1995 were reviewed. RESULTS: Among 93 patients who underwent revision hip arthroplasties, 11 (11.8%) had a history of previous malignancy. At surgery, in 2 of these patients, metastasis was found to be the cause of loosening in the affected hip. CONCLUSIONS: When revision hip arthroplasty is considered, patients with a history of malignancy require attenuated pre-, intra-, and postoperative workup. Management algorithm in such cases is proposed.

Aged↗

Voice restoration after laryngectomy: experience with the Blom-Singer extended-wear indwelling tracheoesophageal voice prosthesis.

BACKGROUND: The Blom-Singer tracheoesophageal voice prosthesis has undergone continuous design modifications during the last 18 years to make it more effective, anatomically compatible, and easier to use. This evolution continues with the recent introduction of an indwelling-style voice prosthesis intended for use by individuals who are unable or disinclined to use a self-removable-style voice prosthesis. The a priori self-lifespan goal of the indwelling prosthesis was 180 days. METHODS: The present investigation describes the experience of 81 consecutive participants who used a total of 206 indwelling voice prosthesis. Selection criteria included total laryngectomy and either primary (n = 35) or secondary (n = 46) tracheoesophageal puncture. All participants had external-beam radiotherapy either pre- or postlaryngectomy. Specifically, lifespan of the prosthesis, the effects and clinical management of fungal colonization, and participant satisfaction with this style prosthesis were studied. RESULTS: A prosthesis use rate of 90% was observed. Group 1 prostheses (without fungal colonization and without Nystatin therapy) exhibited a lifespan significantly longer than did group 2 prostheses (with fungal colonization and prior to Nystatin therapy) (sample mean [mean] = 185.6 days versus 80.6 days; p < .05). Group 3 prostheses (following Nystatin therapy) also exhibited a lifespan significantly longer than that of group 2 prostheses (mean = 156.1 days versus 80.6 days; p < .05). Lifespans of group 1 and group 3 prostheses were not significantly different (p < .05). CONCLUSIONS: The extended-wear, indwelling voice prosthesis achieved its a priori lifespan goal of 180 days (6 months) with almost uniform patient preference and without risk of increased complications. When fungal colonization was present. Nystatin therapy significantly prolonged prosthesis lifespan.

Adult↗

Tuberculous and foreign-body granulomatous reactions involving a total knee prosthesis.

This case report describes loosening of a right knee prosthesis and represents the first report of the simultaneous occurrence of 2 granulomatous processes involving a prosthetic joint. Microscopic examination of the tissue revealed areas of foreign-body granulomas and areas of necrotizing granulomas and caseation. Acid-fast bacilli cultures were positive for Mycobacterium tuberculosis. The pathophysiology of implant loosening following an inflammatory reaction to components of prosthetic materials is discussed. Also discussed is the occurrence of infectious complications and rarity of tuberculous infections associated with prosthetic implants.

Aged↗

Biofilm formation and design features of indwelling silicone rubber tracheoesophageal voice prostheses--an electron microscopical study.

After total laryngectomy, voice can be restored with a silicone rubber tracheoesophageal voice prosthesis. However, biofilm formation and subsequent deterioration of the silicone material of the prosthesis will limit device life by impairing valve function. To simulate the natural process of biofilm development under dynamic nutrient conditions, a modified Robbins device was used to evaluate the biofilm-related valve dysfunction of the Groningen, Provox2, Blom-Singer indwelling, and VoiceMaster voice prostheses. Obstruction of the semicircular slit-valved Groningen prosthesis leading to increased airway resistance was caused not only by a buildup of deposits on the esophageal flange and valve hat, but also by accumulation of deposits on the semicircular valve seating. The hinged flap valved Provox2 and indwelling Blom-Singer prostheses failed to close sufficiently because of biofilm formation on the valve seating. The esophageal flange of the VoiceMaster prosthesis was affected, but the tripod structure of the ball valve was fully colonized up to the titanium sleeve, which interfered with proper valve opening and closure. These findings on biofilm formation could be used for the further development and modification of critical design features of voice prostheses to facilitate tracheoesophageal speech.

Bacterial Adhesion↗

White blood cell scintigraphy with monoclonal antibodies in the study of the infected endoprosthesis.

Forty-three patients with suspected infection of a hip or a knee prosthesis were studied with white blood cell scintigraphy (WBC), using technetium-99m (n = 37) or iodine-123 (n = 6) labelled monoclonal mouse antibody (MoAb). Previously, all patients had undergone skeletal scintigraphy, which was performed as a three-phase study in 33 cases. The final diagnosis was established by open surgery, histology and culture in 37 cases, by puncture and culture in 3 cases, and by clinical follow-up of at least 6 months in 3 cases. Eighteen prostheses were infected, 25 uninfected. The delayed phase of skeletal scintigraphy had a sensitivity of 92%, a specificity of 24% and an accuracy of 48% in the detection of infection. The perfusion and blood pool activity of the three-phase bone scan had a sensitivity of 67%, a specificity of 71% and an accuracy of 70%. The diagnostic value of WBC was sensitivity 89%, specificity 84% and accuracy 86%. WBC with 99m-Tc-MoAb is easy to perform and always available. Its diagnostic accuracy is similar to conventional WBC scintigraphy with either indium-111 or technetium-99m.

Adult↗