Ipsilateral dislocation of the shoulder and elbow joints with contralateral comminuted humeral fracture.

Ipsilateral dislocation of the shoulder and elbow joints is a rare and complex injury. During the last 25 years, only 3 cases have been reported in the literature. We report a 50-year-old woman who suffered ipsilateral elbow and shoulder dislocation with contralateral comminuted humeral fracture. Both shoulder and elbow joints were reduced, but the elbow was dislocated subsequently at follow-up. The reduction in the elbow was stabilized by a Kirschner wire that was removed at 3 weeks, and the elbow was then stable. A U-shaped coaptation splint was applied for the contralateral comminuted humeral fracture. At 6 months, she had acquired a nearly full range of motion of both shoulder and elbow with complete healing in the contralateral humerus. Although rare and complex, ipsilateral shoulder and elbow dislocation, which is the result of a high-energy trauma, can be treated conservatively.

Elbow Joint↗

Capitellocondylar total elbow replacement. A long-term follow-up study.

Fifty-one capitellocondylar elbow replacements were inserted in forty-one patients between 1976 and 1986. Thirty-nine patients had rheumatoid arthritis and two had traumatic osteoarthrosis. The average age of the patients at the time of the operation was fifty-six years (range, twenty-one to seventy-seven years). Thirty-one patients who had thirty-nine retained elbow prostheses had an average length of follow-up of 6.5 years (range, two to thirteen years). Flexion improved an average of 20 degrees; extension, 4 degrees; pronation, 22 degrees; and supination, 36 degrees. Relief of pain was complete in 85 per cent of the thirty-nine elbows, and in 15 per cent there was only mild pain. Noteworthy postoperative complications in the original fifty-one elbows included infection in four elbows (8 per cent), dislocation in three (6 per cent), and ulnar neuropathy in sixteen (31 per cent). Three elbows were revised: one for a humeral fracture, one for recurrent dislocation, and one for aseptic loosening. Aseptic loosening was evident on radiographs of two elbows; one patient was completely asymptomatic, and one had mild pain with deformity. The Souter zonal radiographic assessment system for identification of radiolucencies at the bone-cement interface was utilized; there was no significant difference in radiolucencies between ulnar components backed with metal and those that were not backed with metal. Kaplan-Meier cumulative survivorship analysis demonstrated that a functional prosthesis was retained in 88 per cent of the elbows at 1.4 years postoperatively and in 83 per cent at 5.5 years.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Grip strength: effects of testing posture and elbow position.

This study was designed to determine the effect of testing posture and elbow position on grip strength. A hand dynamometer was used to measure the grip strength of 61 subjects (26 female and 35 male) in four positions: (1) sitting with elbow in 90 degree flexion, (2) sitting with elbow in full extension, (3) standing with elbow in 90 degree flexion, and (4) standing with elbow in full extension. The four experimental conditions were randomized, and standardized instructions were followed. A two-factor (gender and treatment) repeated measures ANOVA was used to determine any significant difference in grip strength between the sexes and the experimental (treatment) conditions. The result of the ANOVA revealed a significant F-ratio for gender and treatment main effects. Scheffé post hoc analysis revealed that males had higher (p less than .01) grip strength than females at all the testing postures and elbow joint angles, and that there was a significant (p less than .05) difference between the grip strength measured in subjects sitting with the elbow in 90 degree flexion and standing with the elbow in full extension. The findings suggest the need for clinicians to maintain standard testing conditions while measuring grip strength.

Adolescent↗

Elbow injuries in athletes. A review.

Elbow injuries are becoming more common as increasing numbers of people participate in throwing and racquet sports. The understanding and treatment of elbow injuries is becoming more sophisticated in conjunction with better noninvasive and invasive diagnostic techniques. The majority of injuries to the elbow in the athlete are chronic, overuse injuries. These injuries are the result of repetitive intrinsic or extrinsic overload, or both, resulting in microrupture of soft tissue such as ligament or tendon. In children, apophyses, being the weakest link in the immature musculoskeletal system, are susceptible to stress injuries. Elbow injuries are most commonly caused by valgus stress, from throwing or axial compression, resulting in increased force absorbed by the medial elbow. With repetitive valgus stress, patients may develop chondromalacia, loose bodies in the posterior or lateral compartments, injury to the ulnar collateral ligament, myotendinous injury to the flexor-pronator muscle group, osteochondritis dissecans, or ulnar neuritis. The purpose of this paper is to (1) define the significance of elbow injuries in athletics, (2) review the anatomy and biomechanics of the elbow, and (3) discuss the prevention and treatment of elbow injuries.

Athletic Injuries↗

Biomechanics of the elbow and forearm.

The elbow joint functions as a link between the shoulder and wrist providing an exceptional amount of stability and motion. The elbow joint should not be considered a simple hinge joint; rather there are important out-of-plane motions that affect implant design and surgical reconstruction of the elbow. Forearm rotation, which occurs as the radius wraps around the ulna, guided by the soft tissues at the wrist and elbow joints, also contributes to upper extremity mobility. Force transmission in the forearm is a complex interaction of the radius, ulna, and interosseous membrane. Forces at the wrist affect the transmission of force through the forearm to the elbow joint. During some activities, forces at the elbow joint can reach several times body weight. These motion, stability, and force interactions allow for the forearm's function. It should be recognized that an event at the elbow joint affects the forearm and the wrist, and conversely injury or disease at the wrist joint can affect the elbow.

Biomechanical Phenomena↗

The radiological diagnosis of posttraumatic effusion of the elbow joint and its clinical significance: the 'displaced fat pad' sign.

Alterations occur in the radiological appearance of the soft tissues after injury to the elbow joint. These are due to displacement of the intra-articular fat pads by capsular distension when an effusion is present. A prospective study of 89 consecutive elbow injuries was undertaken in an attempt to assess the usefulness and reliability of these changes in the diagnosis of minor elbow injuries and the assessment of their clinical progress. In 61 elbows (69 per cent) there was no radiological evidence of an effusion and no evidence of bony injury. All quickly returned to normal. In 28 elbows (31 per cent) radiological evidence of an effusion was present. Twenty-three (80 per cent) of these were also found to have a fracture in, or adjacent to the elbow joint. In 9 elbows the fracture could not be seen on the initial radiographs. Because of the presence of an effusion, repeat radiographs were taken and a fracture discovered. The presence of an effusion was associated with an increase in the time required for full recovery.

Adipose Tissue↗

[Endoprosthesis implantation in the elbow joint].

Previously used total elbow prostheses were mainly constrained hinged implants. Their early clinical results were favourable but they failed due to a high rate of loosening already a few years after implantation. The cause for the early loosening was the great forces across the elbow joint which were directly transmitted to the prosthesis-bone interface in these implants. Therefore, these implants were abandoned. Afterwards, unlinked, semiconstrained or non-constrained resurfacing devices were introduced. In these devices, the soft tissues constrain the joint and therefore absorb part of the transmitted forces. The rates of loosening were significantly improved and rarely the cause of early failure. But resurfacing implants require intact condyles and collateral ligaments. These implants can, therefore, only be used in a limited number of indications, and postoperative instabilities are known complications. The currently most frequently used device is the semiconstrained Coonrad-Morrey prosthesis. It is a floppy hinge which allows valgus-varus and rotational laxities. Therefore, a part of the forces across the elbow joint are absorbed by the soft tissues. The loosening rate is not a clinical problem any more, and is with 4% 10 years after implantation (rheumatoid arthritis) similar to that of total hip or knee replacement. Furthermore, this device is stabilised with a small anterior flange to the anterior cortex of the humeral shaft. Condyles and collateral ligaments are therefore not necessary neither for short nor for long-term stability. The Coonrad-Morrey total elbow prosthesis can therefore be used for almost every indication, such as severe destruction of the elbow joint and even in case of complete loss of the distal humerus. The long-term outcome with this prosthesis for the treatment of rheumatoid arthritis is favourable with 96% of very good and good results. Function is restored with an average flexion of 131 degrees, a mean loss of extension of 28 degrees, and an unrestricted pronation and supination. The rate of complications for patients with rheumatoid arthritis is 10%. Similarly, the results for Coonrad-Morrey total elbow replacement for posttraumatic arthrosis are favourable with 83% of satisfactory results. Most patients consider their elbow as improved compared to preoperatively, but pain relief is obtained only in three quarters of the patients. The rate of complications is high with 30%, indicating the total elbow replacement is contraindicated for strenuous labour and sports activities.

Arthritis, Rheumatoid↗

Comparison of visual and objective quantification of elbow and shoulder movement in children with obstetric brachial plexus palsy.

BACKGROUND: The Active Movement Scale is a frequently used outcome measure for children with obstetric brachial plexus palsy (OBPP). Clinicians observe upper limb movements while the child is playing and quantify them on an 8 point scale. This scale has acceptable reliability however it is not known whether it accurately depicts the movements observed. In this study, therapist-rated Active Movement Scale grades were compared with objectively-quantified range of elbow flexion and extension and shoulder abduction and flexion in children with OBPP. These movements were chosen as they primarily assess the C5, C6 and C7 nerve roots, the most frequently involved in OBPP. Objective quantification of elbow and shoulder movements was undertaken by two-dimensional motion analysis, using the v-scope. METHODS: Young children diagnosed with OBPP were recruited from the Royal Children's Hospital (Melbourne, Australia) Brachial Plexus registry. They participated in one measurement session where an experienced paediatric physiotherapist facilitated maximal elbow flexion and extension, shoulder abduction and extension through play, and quantified them on the Active Movement Scale. Two-dimensional motion analysis captured the same movements in degrees, which were then converted into Active Movement Score grades using normative reference data. The agreement between the objectively-quantified and therapist-rated grades was determined using percentage agreement and Kappa statistics. RESULTS: Thirty children with OBPP participated in the study. All were able to perform elbow and shoulder movements against gravity. Active Movement Score grades ranged from 5 to 7. Two-dimensional motion analysis revealed that full range of movement at the elbow and shoulder was rarely achieved. There was moderate percentage agreement between the objectively-quantified and therapist-rated methods of movement assessment however the therapist frequently over-estimated the range of movement, particularly at the elbow. When adjusted for chance, agreement was equal to chance. CONCLUSION: Visual estimates of elbow and shoulder movement in children with OBPP may not provide true estimates of motion. Future work is required to develop accurate, clinically-acceptable methods of quantifying upper limb active movements. Since few children attained full range of motion, elbow and shoulder movement should be monitored and maintained over time to reduce disability later in life.

Journal Article↗

Pressure loss in elbow pipes of unplasticized polyvinyl chloride.

In the ductwork of local exhaust systems, 90 degrees elbow pipes (JIS K 6739) are commonly used to alter the direction of airflow; thus, are important components of polyvinyl chloride (PVC) ducts. Pressure loss in 90 degrees PVC elbow pipes was investigated by measuring static pressure, and the characteristics of airflow was determined. First, a linear decrease in static pressure was observed at points of the downstream side beyond a distance of 10 times the diameter (10d) from the flanged round opening of the smooth VU ducts (JIS K6741). The linear decrease was also observed at points of the downstream side located at distances of greater than 30d from the elbow pipe. Coefficients of loss in the PVC elbow pipes were found to be constant for the Reynolds numbers ranging from 3.38 x 10(4) to 5.96 x 10(5) for all diameters examined, and a chart of pressure loss was constructed with these coefficients. The coefficients of loss in PVC elbow pipes were not equivalent to those of metal stamped elbows for any R/d. However, the differences in the coefficients between the metal stamped elbow and the PVC elbow were smaller with larger R/d values.

Equipment Design↗

[Experiences with the GSB (Geschwend-Scheier-Bähler) III total endoprosthesis in the elbow joint].

Studies on the results with elbow prostheses published in the seventies reported on marked problems such as high loosening rates and instabilities of the joints. However, enormous progresses in elbow replacements have been made in the meantime. Therefore, we analyzed the results of the GSB III-elbow-prostheses that were implanted in our department for 9 years. Between January 1, 1987 and April 1995 at our department 34 total elbow replacements were performed in 32 patients. In this study, we reviewed 25 patients with elbow replacements both clinically and radiologically. The clinical outcome was rated according to the score of INGLIS and PELLICI. The mean follow-up time was 3.7 years. Our follow up examination revealed a total complication rate of 22%. Septic prosthesis loosening with explantation of the prostheses occurred in 3 patients resulting in a prosthesis survival-rate of 88%. However, clinical assessment revealed 80% excellent or good results. While the range of motion could only be improved to a small degree, a marked reduction of the preoperative pain could be achieved. Patients were satisfied with the outcome of the operation in 97%. Although the results of total elbow arthroplasties cannot be compared with those of hip or knee arthroplasties, in selected patients with rheumatoid arthritis and osteoathrosis the use of elbow replacements proved to be a successful procedure with satisfactory results. The implantation of elbow prostheses should mainly be considered when debilitating pain, strongly limited range of motion and instability of the joint are the main problems.

Arthritis, Rheumatoid↗

Throwing injury of the elbow: assessment with gradient three-dimensional, fourier transform gradient-echo and short tau inversion recovery images.

We assessed MR findings of throwing injuries occurring in the elbow joint using three-dimensional Fourier transform (3DFT) and short tau inversion recovery (STIR) images. MR images of 63 elbows in 63 male patients aged from 10 to 32 years (mean age, 15 years 11 months) suffering from throwing injury were visually analyzed. The sequences used for the study were axial 3DFT and coronal STIR. Full-thickness tears were demonstrated in 34 elbows and undersurface tears of the ulnar collateral ligament (UCL) were demonstrated in five elbows. Thirty loose bodies were detected in 14 elbows. Cartilaginous damage due to osteochondral injury was depicted in 21 elbows. Multiplanar reformatted images using the 3DFT data set were useful for assessing torn UCLs, intraarticular loose bodies, and capitellar fragments. Full-thickness tears and undersurface tears of the UCL could be differentiated with STIR images. 3DFT and STIR sequences depict various aspects of throwing injuries occurring in the elbow.

Adolescent↗

Magnetic resonance imaging of the elbow. Part I: normal anatomy, imaging technique, and osseous abnormalities.

Part I of this comprehensive review on magnetic resonance imaging of the elbow discusses normal elbow anatomy and the technical factors involved in obtaining high-quality magnetic resonance images of the elbow. Part I also discusses the role of magnetic resonance imaging in evaluating patients with osseous abnormalities of the elbow. With proper patient positioning and imaging technique, magnetic resonance imaging can yield high-quality multiplanar images which are useful in evaluating the osseous structures of the elbow. Magnetic resonance imaging can detect early osteochondritis dissecans of the capitellum and can be used to evaluate the size, location, stability, and viability of the osteochondritis dissecans fragment. Magnetic resonance imaging can detect early stress injury to the proximal ulna in athletes. Magnetic resonance imaging can detect radiographically occult fractures of the elbow in both children and adults. Magnetic resonance imaging is also useful in children to further evaluate elbow fractures which are detected on plain-film radiographs.

Adult↗

Fracture and nonunion of the olecranon in total elbow arthroplasty.

BACKGROUND: While fracture and nonunion of the olecranon have been reported in patients undergoing total elbow arthroplasty, little information exists about the management and outcome of these cases. METHODS: Twenty-four patients (twenty-five elbows) were studied; fifteen (sixteen elbows) with rheumatoid arthritis and nine with post-traumatic elbow disorders. Twenty-three of the twenty-five elbows presented with an olecranon fracture or nonunion prior to the reported arthroplasty. During arthroplasty the olecranon fragment was initially treated by tension band in sixteen elbows, excision in four, suture fixation in two and three with stable fibrous union were left alone. RESULTS: At an average follow-up of 66 months (range, 18 to 242), there were twelve excellent, nine good, three fair and one poor results. The mean pre-operative Mayo Elbow Performance Score improved from 42 (range, 20 to 62) points pre-operatively to 86 (range, 50 to 100) points post-operatively (p < 0.001). Of the eighteen patients undergoing an attempt at union, nine (50%) obtained osseous union, eight (45%) developed a stable fibrous union and one patient underwent subsequent excision of the fragment due a superficial infection (5%). Fifteen of twenty-one could extend the hand above the head against gravity. CONCLUSION: A functional arc of motion and satisfactory clinical outcome can be achieved with osseous or a stable fibrous nonunion.

Adult↗

Upper-limb surface electro-myography at maximum supination and pronation torques: the effect of elbow and forearm angle.

Forearm pronation and supination, and increased muscular activity in the wrist extensors have been both linked separately to work-related injuries of the upper limb, especially humeral epicondylitis. However, there is a lack of information on forearm torque strength at ranges of elbow and forearm angles typical of industrial tasks. There is a need for strength data on forearm torques at different upper limb angles to be investigated. Such a study should also include the measurement of muscular activity for the prime torque muscles and also other muscles at possible risk of injury due to high exertion levels during tasks requiring forearm torques.Twenty-four male subjects participated in the study that involved maximum forearm torque exertions for the right arm, in the pronation and supination directions, and at four elbow and three forearm rotation angles. Surface EMG (SEMG) was used to evaluate the muscular activity of the pronator teres (PT), pronator quadratus (PQ), biceps brachi (BB), brachioradialis (BR), mid deltoid (DT) and the extensor carpi radialis brevis (ECRB) during maximum torque exertions. Repeated measures ANOVA indicated that both direction and forearm angle had a significant effect on the maximum torques (p<0.05) while elbow angle and the interactions were highly significant (p<0.001). The results revealed that supination torques were stronger overall with a mean maximum value of 16.2 Nm recorded for the forearm 75% prone. Mean maximum pronation torque was recorded as 13.1 Nm for a neutral forearm with the elbow flexed at 45 degrees. The data also indicated that forearm angle had a greater effect on supination torque than pronation torque. Supination torques were stronger for the mid-range of elbow flexion, but pronation torques increased with increasing elbow extension. The strength profiles for the maximum torque exertions were reflected in the EMG changes in the prime supinators and pronators. In addition, the EMG data expressed as the percentage of Maximum Voluntary Electrical activity (MVE), revealed high muscular activity in the ECRB for both supination (26-43% MVE) and pronation torques (17-55% MVE). The results suggest that the ECRB acts as a stabiliser to the forearm flexors for gripping during pronation torques depending on forearm angle, but acts as a prime mover in wrist extension for supination torques with little effect of elbow and forearm angle. This indicates a direct link between forearm rotations against resistance and high muscular activity in the wrist extensors, thereby increasing stress on the forearm musculo-skeletal system, especially the lateral epicondyle.

Adult↗

Imaging overuse injury of the elbow in professional team handball players: a bilateral comparison using plain films, stress radiography, ultrasound, and magnetic resonance imaging.

The purpose of this study was to compare the manifestations of elbow stress due to repetitive valgus forces between the dominant and the non-dominant elbow in 40 uninjured elite team handball players using plain films, stress radiographs, ultrasound, and MRI examination. On comparative plain films generalized bony hypertrophy manifested by increased humeral diameter, and cortical hypertrophy of the humeral shaft of the dominant extremity was observed in all players. A significantly greater difference in medial joint space opening between stressed and unstressed elbows was measured in the dominant elbow compared with the non-dominant elbow (0.41 +/- 0.59 mm). The ultrasonographic findings showed statistically significant bilateral differences in the thickness of the flexor-pronator tendon (0.90 +/- 0.56 mm), extensor tendon (0.96 +/- 0.50 mm), triceps tendon (0.69 +/- 0.27 mm), and medial collateral ligament (0.47 +/- 0.24 mm): the values were systematically higher on the dominant side. US examination showed intra-articular effusions in 67% and small loose bodies in 33.3% of the players, exclusively in dominant elbows. MRI showed joint effusion in the same subjects as US, but loose bodies were only detected in half of the cases found by ultrasound. This study demonstrates that repetitive stress on the dominant extremities of handball players is responsible for physiologic and pathologic changes in the dominant elbow.

Adolescent↗

Elbow instability: the orthopedic approach.

In recent years significant progress has been made in the diagnosis and treatment of elbow instability. Elbow instability represents a spectrum from the acute traumatic dislocation to chronic laxity resulting in transient joint subluxation. In general, acute elbow dislocations represent the second most common joint dislocation in the adult population and the most common joint dislocation in the pediatric age group. This manuscript reviews the anatomy of the elbow joint as it relates to elbow instability. It then discusses the mechanism and classification of elbow instability and outlines treatment options available for acute and chronic elbow instability.

Elbow Joint↗

Reverse pedicled lateral arm flap for reconstruction of posterior soft-tissue defects of the elbow.

Posterior soft-tissue defects of the elbow are difficult to reconstruct by conventional techniques such as closure by approximation or skin graft. An ideal technique should be an easy and reliable one-stage procedure that provides predictable surgical results with regard to elbow function and cosmesis. This report details our experience in 7 patients who underwent a one-stage procedure for coverage of the posterior elbow employing the reverse pedicled lateral arm flap. All flaps survived and all patients were able to resume full range of motion of the elbow joint at the 6-month follow-up. Complications included forearm paraesthesia in 3 patients and conspicuous scarring in a young female patient. We emphasize two valuable refinements in surgical technique including measuring posterior elbow defect in full flexion and postoperative elbow extension splinting. In trauma-related defects of the posterior elbow, a preoperative angiogram is important before raising this flap.

Adolescent↗

Classification and evaluation of recurrent instability of the elbow.

The clinical presentation, diagnosis, radiographic features, mechanism, pathologic changes, and treatment of elbow instability are understood better now. Elbow instability can be classified according to five criteria: (1) the timing (acute, chronic or recurrent); (2) the articulation(s) involved (elbow versus radial head); (3) the direction of displacement (valgus, varus, anterior, posterolateral rotatory); (4) the degree of displacement (subluxation or dislocation); and (5) the presence or absence of associated fractures. Posterolateral rotatory instability is the most common pattern of elbow instability, particularly that which is recurrent. Posterolateral rotatory instability can be considered a spectrum consisting of three stages according to the degree of soft tissue disruption. Patients typically present with a history of recurrent painful clicking, snapping, clunking, or locking of the elbow and careful examination reveals that this occurs in the extension portion of the arc of motion with the forearm in supination. There are four principle physical examination tests. The most sensitive is the lateral pivot-shift apprehension test, or posterolateral rotatory apprehension test, just as the anterior apprehension test of the shoulder is the most sensitive test for a patient with shoulder instability. Next is the lateral pivot-shift test, or posterolateral rotatory instability test. Reproducing the actual subluxation and the clunk that occurs with reduction usually can be accomplished only with the patient under general anesthesia or occasionally after injecting local anesthetic into the elbow. The third test is the posterolateral rotatory drawer test, which is a rotatory version of the drawer or Lachman test of the knee. The final test is the stand up test as reported by Regan. The patient's symptoms are reproduced as he or she attempts to stand up from the sitting position by pushing on the seat with the hand at the side and the elbow fully supinated. A lateral stress radiograph can show the rotatory subluxation.