Comparison of the Brucella Standard Agglutination Test with the ELISA IgG and IgM in patients with Brucella bacteremia.

The presumptive diagnosis of Brucellosis is based on a high or rising antibody titer measured by the Brucella Standard Agglutination Test (SAT). This tests does not discriminate between the immunoglobulin classes (IgG and IgM). The purpose of this study was to compare the diagnostic value of SAT with Brucella Enzyme Linked Immunosorbent Assay (ELISA) IgG and IgM tests in patients with Brucella bacteremia. Over a one-year period, we had 68 patients with clinical features suggestive of Brucellosis who had positive blood cultures for Brucella species. Sera were obtained from all of the patients as well as a control group of 70 healthy military personnel who were blood donors and had no symptoms of Brucellosis. Patients and blood donors originated from the same referral population. All the sera were tested by SAT and ELISA. All the 70 controls had a negative SAT. The sensitivity and specificity of the SAT test for the bacteremic patients were 95.6% and 100.0% respectively, while that of the ELISA IgG were 45.6% and 97.1%, and that of the ELISA IgM were 79.1% and 100.0% respectively. The sensitivity and specificity of either IgG or IgM positivity were 94.1% and 97.1% respectively. Assuming that the population prevalence of active Brucellosis in Saudi Arabia (SAT >or=1:320) is 5%, the positive and negative predictive values of SAT were 100% and 99.7% respectively; of ELISA IgG they were 45.2% and 97.1%; and of ELISA IgM they were 100% and 98.9%. When both the ELISA IgG and IgM were combined, the positive and negative predictive values were 63% and 99.6% respectively. In patients with Brucella bactremia, the sensitivity of either ELISA IgM or IgG were lower than SAT, however, combining IgM and IgG had similar sensitivity and specificity to SAT. The positive predictive value of SAT and IgM is satisfactory.

Agglutination Tests↗

Comparison of A60 and three glycolipid antigens in an ELISA test for tuberculosis.

OBJECTIVES: To compare the diagnostic usefulness in tuberculosis of the serodiagnostic enzyme-linked immunosorbent assay (ELISA) kit A60 (Anda Biologicals, Strasbourg, France) and of our domestic ELISA based on three purified cell wall glycolipid antigens. METHODS: The presence and concentrations of IgG and IgM anti-A60 antibodies and anti-LOS, anti-DAT and anti-PGLTb1 antibodies against the glycolipid antigens were determined by ELISA in 50 HIV-seronegative and 46 HIV-seropositive patients, with documented active tuberculosis. The specificity of these ELISAs was determined with use of sera from 50 healthy blood donors, 29 patients with non-mycobacterial pulmonary diseases and 24 HIV-positive patients with disseminated Mycobacterium avium infection. RESULTS: With a calculated cut-off for each antigen and immunoglobulin that gave a specificity higher than or equal to 98%, the cumulative ELISA results showed that only 36.5% of the patients with tuberculosis had a positive response in the A60 test, as compared with 84.4% who showed a response to the three glycolipid antigens (p<0.001). This striking difference persisted when the cumulative sensitivities were calculated according to the HIV status of the patients and the localization of tuberculosis. The anti-A60 antibody (IgG and IgM) levels and the degree of sensitivity of the ELISA for detection of A60 antigen were always lower in HIV-positive patients with pulmonary and extrapulmonary tuberculosis than in HIV-negative patients with tuberculosis. The sensitivity of A60 ELISA was further decreased in HIV-positive patients with low CD4+ lymphocytes counts, in contrast to the results with the three glycolipid antigens. CONCLUSIONS: These results show the limitations of the A60 ELISA, and confirm the potencies of the glycolipid antigens in serodiagnosis of tuberculosis in HIV-positive and HIV-negative patients.

Journal Article↗

Evaluation of a commercial ELISA for detecting Norwalk-like virus antigen in faeces.

A commercially available enzyme immunoassay, the IDEIA Norwalk-like virus (NLV) enzyme linked immunosorbent assay (ELISA; Dako Cytomation, Ely, UK) for detecting NLV antigen in faecal samples and determining the NLV genogroup was evaluated. The performance of the ELISA was compared with that of electron microscopy and the reverse transcription polymerase chain reaction by testing a panel of faecal samples collected from patients involved in outbreaks of gastroenteritis. When compared with reverse transcription-polymerase chain reaction (RT-PCR), the ELISA had a sensitivity and specificity of 55.5 and 98.3%, respectively. This compares with a sensitivity and specificity for EM of 23.9 and 99.2%, respectively. The sensitivity and specificity of the ELISA for determining the aetiology of a Norwalk virus-like outbreak, based on two or more positive samples within an outbreak, were 52.2 and 100% when two samples were collected from an outbreak and 71.4 and 100% when six or more samples were collected. The ELISA correctly identified the NLV genogroups of viruses previously characterised by partial DNA sequencing. The ELISA is a suitable alternative to the preliminary screening by EM for investigating outbreaks of gastroenteritis. Outbreaks, negative by ELISA should be examined by RT-PCR in order to detect strains non-reactive in the assay and virus strains from representative ELISA positive outbreaks should be characterised fully to allow the genetic diversity of NLVs co-circulating in the population to be described.

Antigens, Viral↗

Field evaluation of a dot-ELISA for the detection and differentiation of trypanosome species in infected tsetse flies (Glossina spp.).

A rapid, visually read, dot-ELISA developed for the detection and differentiation of trypanosome species in tsetse flies (Glossina spp.), was field tested alongside the standard fly dissection method on a range in south eastern Kenya. Of 104 G. pallidipes dissected, 2 were found to be infected with trypanosomes in their midguts. By the dissection method the infecting trypanosome species could not be identified, as both flies had no salivary gland infections. However, using the dot-ELISA, the 2 flies were shown to be infected with Trypanosoma congolense in their midguts. The midguts of an additional 6 (5.8%) of the 104 G. pallidipes tested positive for T. congolense int he dot-ELISA, even though no trypanosomes were seen on dissection. The infection rate for this fly species as determined using the dot-ELISA, therefore, was 7.7% for T. congolense in midgut infections compared to 1.9% identified by fly dissection. The salivary glands and mouthparts of the 6 additional tsetse flies identified by dot-ELISA were all negative as determined by the 2 techniques. None of 390 G. longipennis flies dissected and examined for trypanosomes in the midgut, salivary glands and mouthparts was shown, by this method, to be infected. Using the dot-ELISA, however, 17 (4.4%) of the flies tested positve for T. congolense in the midgut, whilst the salivary glands and mouthparts of the same flies were negative. Thus, the dot-ELISA appears to be more sensitive than the fly dissection method under field conditions. Moreover, the dot-ELISA can be performed in the field without electricity. It is simple to perform, and was not affected by high ambient temperatures (22-32 degrees C), or by contamination of reactants with dust.

Animals↗

ELISA for monitoring lipid oxidation in chicken myofibrils through quantification of hexanal-protein adducts.

The objectives of this study were to optimize a monoclonal competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) for hexanal detection, optimize solubilization and alkylation procedures for the formation of hexanal-protein adducts, and compare the ability the CI-ELISA, thiobarbituric acid reactive substances assay (TBARS), and a solid-phase microextraction-gas chromatography-mass spectrometry (GC/MS-SPME) method for monitoring lipid oxidation in freeze-dried chicken protein. Freeze-dried myofibrils with added methyl linoleate (0.6 mmol/g of protein) were stored at 50 degrees C at two water activities (a(w) = 0.30 and 0.75) for 5 days. Hexanal was measured by GC/MS-SPME and CI-ELISA, and malonaldehyde by TBARS. At an a(w) of 0.30, 34.7 and 39.7 microg of hexanal/g of myofibril were detected by GC/MS-SPME and CI-ELISA, respectively, after 4 days of storage. At an a(w) of 0.75, 39.8 and 61.1 microg of hexanal/g of myofibril were detected by GC/MS-SPME and CI-ELISA, respectively, after 4 days of storage. The CI-ELISA was well correlated with the GC/MS-SPME (r = 0.78) and TBARS (r = 0.87) methods. The correlation of the hexanal-specific CI-ELISA to both GC/MS-SPME and TBARS verified the ability of the CI-ELISA to be used as an index of lipid oxidation, offering the convenience for use in a kit to be utilized within a food-processing facility.

Aldehydes↗

The use of an oral fluid immunoglobulin G ELISA for the detection of Helicobacter pylori infection in children.

BACKGROUND: Enzyme linked immunosorbent assay (ELISA) evaluation of oral fluid immunoglobulin G (IgG) antibodies to Helicobacter pylori is a unique approach for both epidemiological studies and the diagnosis of infection, especially in children. The use of oral fluid sampling to evaluate specific H. pylori IgG antibodies has advantages over serum, including reduced biohazard risk and noninvasive collection. Oral fluid sampling is fast and involves minimal patient discomfort. Since children facilitate transmission of H. pylori infection, a simple, accurate, noninvasive diagnostic test is necessary for large epidemiologic studies. The aim of our study was to evaluate a new oral fluid ELISA for detection of IgG antibodies to H. pylori in children. MATERIALS AND METHODS: We compared this new oral fluid ELISA with the HM-CAPTM serum ELISA and gastric biopsy histology using 779 oral fluid samples from children collected at 11 clinical sites across the United States. This cohort included 315 children symptomatic for abdominal pain and 464 asymptomatic. All samples were evaluated in a double blind manner. The oral fluid ELISA demonstrated a sensitivity of 76.2% and a specificity of 94.0% in children 2 months old to 201/2 years, as compared with the HM-CAPTM serologic assay. The assay's sensitivity improved to 81.3% in children aged 5 or greater and the specificity remained at 94.0%. When compared with gastric biopsy histology in the same age group, the oral fluid ELISA demonstrated a sensitivity of 71.7% and a specificity of 90.4%. RESULTS: This new oral fluid ELISA is moderately sensitive and offers a very specific method for detecting H. pylori infection in older children, but it is of little value in children under the age of 5 years. CONCLUSIONS: Overall, we conclude that this oral fluid ELISA does not appear to be a helpful clinical tool for the diagnosis of H. pylori infection in children.

Adolescent↗

Clinical evaluation of a capture ELISA for detection of proteinase-3 antineutrophil cytoplasmic antibody.

Detection of antineutrophil cytoplasmic antibodies (ANCA) has become a useful tool in the diagnosis of Wegener's granulomatosis and microscopic polyangiitis. However, the results obtained with indirect immunofluorescence (IIF) and by ELISA for ANCA demonstration do not always correlate. A possible explanation for this finding could be that proteins are denatured during the process of antigen purification or during coating onto the solid phase. To avoid this possibility, a monoclonal antibody to PR3 that is precoated on the plate can be used. In the present study we have used the monoclonal antibody (MoAb) 4A3 for the capture of PR3 in an ELISA, and a clinical evaluation of the diagnostic properties of the new capture ELISA has been made. The sensitivity of the capture PR3-ANCA ELISA was 85% in a material of c-ANCA positive sera. A specificity of 90% was obtained in analyses from patients having various forms of glomerulonephritis. There was a significantly higher diagnostic sensitivity of the capture PR3-ANCA ELISA (85%) compared to c-ANCA by IIF (58%) in patients with Wegener's granulomatosis with renal involvement. Capture PR3-ANCA and direct ELISA for MPO-ANCA together gave a diagnostic sensitivity of 98%, versus 75% using IIF. In conclusion, the capture PR3-ANCA ELISA seems to be a valuable tool in the diagnosis of Wegener's granulomatosis with renal involvement. Preliminary data suggest that the technique may have an advantage over direct ELISA for PR3-ANCA, as well as in the follow-up of c-/PR3-ANCA associated vasculitides. However, further prospective studies are needed to clarify this premise.

Antibodies, Antineutrophil Cytoplasmic↗

Anti-transglutaminase IgA ELISA: clinical potential and drawbacks in celiac disease diagnosis.

BACKGROUND: Since the identification of tissue transglutaminase (tTG) as the antigen for the anti-endomysial antibodies (EMA), several antigen-specific immunoassays have been reported for celiac disease (CD) screening. A first objective was to evaluate the suitability for CD screening of three different IgA tTG ELISAs, two of them based on guinea pig liver tTG (gp-tTG) (an in-house ELISA with a partially purified extract and a commercial ELISA with purified gp-tTG antigen) and a third recombinant human tTG (rh-tTG) ELISA. The results are compared with EMA and with the final clinical diagnosis. A second objective was to analyze antibody reactivities in those patients with anti-tTG and EMA discrepancies. METHODS: ELISA and EMA tests were used to measure IgA anti-tTG levels in sera from 259 patients (107 had CD and 72 had Type I diabetes mellitus). RESULTS: The purified gp-tTG ELISA was highly sensitive (97.7%) and specific (98.8%) in the detection of CD, almost equaling EMA. Rh-tTG ELISA did not improved the sensitivity of EMA, but its specificity was slightly superior. Immunoblot analysis with partially purified gp-tTG extract, the antigen most frequently used for anti-tTG detection, showed that the majority of false positives were due to IgA reactivities to contaminant proteins present in the liver antigenic extract. This low specificity was particularly problematic in diabetics. CONCLUSION: Purified tTG ELISAs, either with purified guinea pig liver or recombinant human antigens, can be used as quantitative and observer-independent alternatives to the traditional and time-consuming EMA in the screening of CD.

Blotting, Western↗

Quantitative liquid-phase chemiluminescence ELISA: detection of subtle epitope differences in HuIFN-beta.

We have developed a new liquid-phase, chemiluminescence-enhanced, inhibition ELISA (LP-CEI-ELISA) to explore the binding sites recognized by two neutralizing monoclonal antibodies (mAb) against recombinant human IFN-(beta)ser (rHuIFN-(beta)ser). In this assay, the initial antigen-antibody reaction occurs in solution under more physiologic conditions than in a standard solid-phase ELISA. Subsequently, the reaction mixture is applied to a membrane that is exposed to a second, peroxidase-labeled mAb, chemiluminescent reagents are added, and the membrane is photographically recorded. Competitive inhibition of binding of a second, labeled mAb by the first mAb decreases the signal detected. Two well-characterized mAb A1 and A7, have been shown to recognize distinct epitopes on rHuIFN-(beta)ser and to neutralize its antiviral and antiproliferative activity (Proc. Natl. Acad. Sci. USA 88, 4040-4044, 1991). In conventional solid-phase ELISA, mAb A1 does not inhibit the binding of A7 to rHuIFN-(beta)ser, but we observed partial inhibition in the new liquid-phase assay. In contrast, A7 did not inhibit the binding of A1, consistent with the solid-phase ELISA results. This observation suggests that in the LP-CEI-ELISA, A1 and A7 may recognize epitopes differently than in solid-phase assays. Thus, the LP-CEI-ELISA, which is simple, sensitive, and quantifiable, appears also to be able to detect subtle, conformational differences of epitopes not evident in a standard solid-phase ELISA.

Binding, Competitive↗

Validation of a microtiter plate ELISA for screening of postmortem blood for opiates and benzodiazepines.

The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for opiates and benzodiazepines for screening of postmortem blood. Ninety postmortem whole blood specimens were obtained from drug-involved deaths which had been screened and confirmed positive for opiates and/or benzodiazepines. Forty negative specimens were obtained from non-opiate-involved deaths. Specimens were tested using the Neogen Opiates Group and Neogen Benzodiazepines Group microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of opiates and benzodiazepines encountered in medical examiner specimens. True positive, true negatives, false positives, and false negatives were determined and graphed for the ELISA results against gas chromatography-mass spectrometry (GC-MS), gas chromatography-nitrogen-phosphorus detection and case histories. From these graphs and the ROC curves, the optimal cut-off for the Neogen Opiates Group ELISA was found to be between 20 and 50 ng/mL morphine equivalents and the optimum cut-off for the Neogen Benzodiazepines Group ELISA was between 20 and 50 ng/mL temazepam equivalents. The Neogen Opiates Group ELISA had a sensitivity of 95.2% +/- 2.7% and a specificity of 92.2% +/- 3.4% versus GC-MS at a cut-off of 20-ng/mL cut-off and a sensitivity of 88.8% +/- 3.9% and specificity of 96.8% +/- 2.1% versus GC-MS at a 50-ng/mL morphine equivalents cut-off. The Neogen Benzodizepines Group ELISA had a sensitivity of 100% +/- 1.3% and a specificity of 94.6% +/- 2.9% versus GC-MS (20-ng/mL temazepam equivalents cut-off) and a sensitivity of 95.8% +/- 2.5% and specificity of 98.2% +/- 1.8% versus GC-MS at a 50-ng/mL cut-off.

Antibodies↗

Rapid enzyme-linked immunosorbent assay (ELISA) for the detection of IgG antibodies against Micropolyspora faeni and Thermoactinomyces vulgaris.

A rapid ELISA was developed for the detection of specific IgG against Micropolyspora faeni and Thermoactinomyces vulgaris and compared with counterimmunoelectrophoresis (CIE) in twenty-seven patients with suspected farmer's lung disease (FLD). Seventeen patients had precipitins to M. faeni or T. vulgaris or both, and ten had no precipitins. The optimum conditions for each step in the ELISA were determined: pre-equilibration of reagents at 37 C and vigorous agitation during incubation enabled the total test time required for the procedure to be reduced to 4 hr. A serum dilution of 10-fold produced good differentiation between CIE-positive and -negative sera. Little correlation was seen between CIE and ELISA for either M. faeni or T. vulgaris antigens in tests with sera from patients with precipitins: high readings were often recorded in ELISA where no precipitins had been detected with the same antigen. Positive-negative discrimination of unknown sera in ELISA was achieved through the inclusion of CIE-positive and -negative reference sera in each test run. Thirteen CIE-positive sera were classed as positive in ELISA with the M. faeni antigen while eight of thirteen CIE-positive sera were positive in ELISA with the T. vulgaris antigen. For both antigens, four CIE-negative sera were recorded as positive in ELISA.

Antibodies, Anti-Idiotypic↗

Major immunoreactive domains of human ribosomal P proteins lie N-terminal to a homologous C-22 sequence: application to a novel ELISA for systemic lupus erythematosus.

The aim of this study was to identify immunoreactive domains on human ribosomal P0, P1 and P2 proteins, other than the C-22 peptide, to develop a novel ELISA using a combination of these proteins and to compare this ELISA with one using the C-22 peptide. Human recombinant P0, P1, P2 and mutant P0 lacking the homologous C-22 peptide (N-P0) were produced in bacteria and tested by ELISA and immunoblotting using sera from 48 patients with systemic lupus erythematosus (SLE), 48 with an unrelated inflammatory disorder (Crohn's disease) and 47 healthy controls. ELISA with P0, P1 and P2, premixed at equimolar concentrations, gave higher OD readings than each protein tested individually. Eighteen SLE sera tested positive by ELISA with premixed P0, P1, P2 but only 3 tested positive with the C-22 peptide. Twenty-two SLE sera reacted positively, as determined by immunoblotting, with 5 different P protein combinations: P1P2, P0P1P2, P1, P0P1, P0 and P1. Only sera reactive with all three P proteins reacted with the C-22 peptide, with absent or minimal reactivity with N-P0. Native antigens yielded sensitivity (6/48, 13%) similar to the C-22 peptide assay. An ELISA with premixed P1 and P2 gave higher OD values than the arithmetic means with P1 or P2. Fifteen SLE patients had antibodies to double stranded (ds)-DNA, of which 6 also had antibodies to P0P1P2 by ELISA but 12 reactive with P0P1P2 did not have discernable ds-DNA antibodies. Ribosomal P autoantibodies react mainly with epitopes N-terminal to a homologous C-22 peptide. An ELISA with premixed P0, P1 and P2 has 5-fold greater sensitivity (38%) for SLE than an assay with the conventional C-22 peptide (7%). The combined sensitivity for SLE for antibodies to P0P1P2 and ds-DNA is 56%, higher than C-22 and ds-DNA, 38%. Only one of the SLE patients had neuropsychiatric lupus.

Amino Acid Sequence↗

Enhanced sensitivity of a second generation ELISA for antibody to hepatitis C virus.

A second generation ELISA for combined detection of antibodies to three hepatitis C virus (HCV) recombinant proteins, i.e. C100, C33c and core, was compared with a first generation anti-HCV ELISA in which only antibodies to C100 are detected. The results of the ELISAs were evaluated in 225 haemophilia patients (panel A) and 44 patients with non-A, non-B (NANB) hepatitis (panel B). HCV infection was established by cDNA-polymerase chain reaction (PCR) (in panel B only) and by studying the anti-HCV reaction patterns in 4 separate ELISAs for detection of antibodies to the recombinant proteins C100, C33c, core and a combination of two synthetic peptides sp67/65 derived from the C100 region. The sensitivity for the detection of HCV infection had increased from 0.92[95% confidence interval (CI): 0.87-0.95] to 1.00 (95% CI: 0.89-1.00) in haemophiliacs and from 0.84 (95% CI: 0.66-0.95) to 1.00 (95% CI: 0.89-1.00) in NANB hepatitis patients when the second generation ELISA was used instead of the first generation ELISA. Concurrently the chance of a false negative result was reduced in panel A and B from 0.37 to 0 and from 0.28 to 0, respectively. Analysis of anti-HCV reaction patterns revealed that 172 of 206 (83.5%) anti-HCV ELISA-reactive haemophilia patients had antibodies to all 4 antigens tested. In the NANB hepatitis patients 18 of 31 (58.1%) anti-HCV ELISA-reactive subjects reacted with 4 antigens. In the PCR tested panel of NANB hepatitis patients 2 subjects who showed antibody reactivity to only one antigen and 5 patients with reactivity to 2 antigens were PCR-positive.(ABSTRACT TRUNCATED AT 250 WORDS)

Antigens, Viral↗

Verification of sensitivity and specificity of group a rotavirus detection in piglets faeces with monoclonal blocking ELISA methods.

Monoclonal antibodies to group A rotavirus Vp6 protein were prepared and used for verification of three blocking enzyme-linked immunosorbent assay (ELISA) modifications to detect rotavirus A. Selected competitive blocking ELISA (CB-ELISA) and electron microscopy (EM) were used for examination of 194 field faecal samples of piglets affected with diarrhoea. Rotavirus was detected in 43 samples (22.2%) by CB-ELISA method, whereas in 26 (13.4%) samples by EM examination. However, of 26 samples positive by EM, rotavirus A was detected by CB-ELISA in 19 (73.1%) samples; indicating the share of group A rotavirus in all cases of gastroenteritis caused by rotavirus. The sensitivity and specificity of the CB-ELISA was verified both by inclusion of control samples containing transmissible gastroenteritis virus (TGEV) and porcine epidemic diarrhoea virus (PEDV) in each analysis and by comparative examination of samples with the commercial ELISA kit. The CB-ELISA sensitivity was positively affected by examination of samples in the presence of chelating agent.

Animals↗

Detection of serum antibodies against Chlamydia pneumoniae by ELISA.

Chlamydia pneumoniae causes pneumonia and other respiratory infections in children, adolescents and adults. We tried to evaluate the diagnostic value of detection of serum antibodies by ELISA for C. pneumoniae infections in Japanese children. Serum IgG, IgA and IgM antibodies to C. pneumoniae were determined by the microimmunofluorescence (MIF) test. Serum IgG and IgA antibodies were also determined by ELISA test kits. Results obtained by ELISA were compared with those obtained by MIF test. IgG antibody to C. pneumoniae was detected in 135 (39.5%) by ELISA and in 125 (36.5%) by MIF out of 342 sera from Japanese infants and children without respiratory infections (aged from 2 months old to 15 years old). IgA antibody to C. pneumoniae was detected in 129 (37.7%) by ELISA and in 117 (34.2%) by MIF out of 342 sera tested. Of 342 specimens 113 were IgG-positive by ELISA and MIF (sensitivity: 90.4%, specificity: 89.9%, r = 0.853). Of 342 sera 28 had IgG antibody titers of 1:256 and none had titers 1:512 or higher by MIF. Of 28 infants and children a total of nine were less than 4 years of age. On the other hand, of 342 specimens 99 were IgA-positive by ELISA and MIF (sensitivity: 84.6%, specificity: 86.7%, r = 0.769). Of 342 sera 16 had IgA antibody titers of 1:256 or higher by MIF. Of 16 infants and children, ten were less than 4 years of age. ELISA had excellent sensitivity and specificity relative to MIF test for detection of IgC and IgA antibodies to C. pneumoniae. It was suggested that C. pneumoniae infection in Japanese infants and children under 4 years of age was not infrequent.

Adolescent↗

An ELISA for the detection of anergic tuberculous cattle.

An enzyme-linked immunosorbent assay (ELISA) for bovine antibody to antigens in unheated Mycobacterium bovis culture filtrate was standardised against a reference serum from an experimentally infected cow. Two Northern Territory herds with a total of 561 cattle were tested. All cattle reacting in the caudal fold tuberculin test, those giving strong reactions in the ELISA and those with visible lesions of tuberculosis were subjected to a detailed bacteriological examination. Of the 19 cattle which yielded isolates of M. bovis, only 4 were positive to the tuberculin test. Serum samples from 5 cattle gave ELISA values greater than 7.0 units. None of these 5 reacted in the tuberculin-test and 2 had no visible lesions. Of the 10 remaining cattle from which M. bovis was isolated, 3 had ELISA values between 6.5 and 7.0 units and were also without visible lesions. The ELISA values for the remaining 7 infected cattle ranged down to 4.6 units. Forty cattle yielded no M. bovis on culture of their tissues. They included 7 which were reactors in the tuberculin test and 23 with ELISA values of 7.0 units or more. The evident low specificity and sensitivity of the ELISA make it of little value as an alternative to the tuberculin test, but it can detect some anergic cattle at the cost of increasing the number of false positive reactors. This may be acceptable in some circumstances and would justify the use of the ELISA as a complement to the tuberculin test or to an in vitro assay of T-cell immunity. In the 2 Northern Territory herds described, the removal of 5 of the anergic cattle would have required a cull of 28 animals of 5% of the total. A cut off value of 6.5 units would have eliminated 3 more, but at the cost of culling 80 animals or nearly 15% of the cattle. Even so, 7 cattle from which M. bovis was isolated would have remained undetected by either test.

Animals↗

Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen 1 in both forms of ELISA, but two failed to react with antigen 2 in the standard ELISA and three failed to react with this antigen in the rapid method. Thirteen AGDD-negative sera were also negative in both forms of ELISA. The rapid ELISA provides a sensitive and reproducible test for routine serological investigation of allergic aspergillosis.

Antibodies, Fungal↗

Plasma glycocalicin as a source of GPIbalpha in the von Willebrand factor ristocetin cofactor ELISA.

We have previously demonstrated that the von Willebrand factor ristocetin cofactor activity (VWF:RCo), used in the diagnosis of vonWillebrand disease (VWD), can be accurately determined via ELISA by measuring the ristocetin-induced binding of VWF to a captured recombinant fragment of GPIbalpha (rfGPIbalpha, AA 1-289) (Vanhoorelbeke et al., Thromb Haemost 2000; 83: 107-13). This ELISA is more reliable than the currently used platelet agglutination test. Normal plasma contains relatively high concentrations of glycocalicin, a proteolytic fragment of GPIbalpha. We therefore studied whether non-purified plasma glycocalicin can replace rfGPIbalpha in our ELISA. Of 42 anti-GPIbalpha monoclonal antibodies (MAbs) capable of binding plasma glycocalicin, only one MAb captured glycocalicin in a spatial orientation exposing the VWF-binding site in glycocalicin, allowing a specific and dose-dependent ristocetin-mediated VWF-binding. Intra- and interassay variability were comparable with those for the rfGPIbalpha based VWF:RCo ELISA. The VWF:RCo activity of plasma from 33 normal individuals, 19 type 1, 16 type 2A, 9 type 2B, 8 type 2M and 7 type 3VWD patients was determined with this ELISA and allowed a clear identification of VWD patients. Furthermore, determination of the VWF:RCo/VWF:Ag ratio resulted in the discrimination between type 1 and type 2 VWD patients. Results for the glycocalicin based and the rfGPIbalpha based VWF:RCo ELISAs were in good agreement (r=0.943). There was also a good correlation between the glycocalicin based ELISA and the standard platelet agglutination test (r=0.963). In conclusion, to diagnose VWD, a VWF:RCo ELISA based on antibody immobilized plasma glycocalicin can be performed reliably.

Diagnosis, Differential↗