Nonuniform heating patterns of commercial electrodes for radiofrequency catheter ablation.

INTRODUCTION: Previous investigations of the biophysics of myocardial ablation using radiofrequency energy have focused mainly on the electrode-myocardial interface. Relatively little has been written about the overall function of commercial electrodes used for ablation. The purpose of this study was to evaluate the heating patterns of several commercial electrodes used for myocardial ablation. METHODS AND RESULTS: The specific absorption rate, a unit of measure proportional to the initial rate of rise of the temperature at the electrode-tissue interface and reflecting the energy deposition from the electrode, was measured during radiofrequency energy application at multiple points around each electrode. These measurements were combined to form a specific absorption rate pattern, which reflected the spatial pattern of energy deposition from the electrode. There was significant nonuniformity of the specific absorption rate pattern of each electrode evaluated. The proximal edge of the electrode and the curvature of the distal portion of the electrode were two sites of accentuated heating relative to the remaining portions of the electrode. The magnitude of this nonuniformity was similar between the 4-mm length electrodes of different manufacturers, but increased progressively in larger (5- and 8-mm length) electrodes. CONCLUSIONS: The heating patterns of commercial electrodes used for myocardial ablation are nonuniform. These data have implications for electrode design and utilization.

Catheter Ablation↗

Frequency-to-electrode allocation and speech perception with cochlear implants.

The hypothesis was investigated that selectively increasing the discrimination of low-frequency information (below 2600 Hz) by altering the frequency-to-electrode allocation would improve speech perception by cochlear implantees. Two experimental conditions were compared, both utilizing ten electrode positions selected based on maximal discrimination. A fixed frequency range (200-10513 Hz) was allocated either relatively evenly across the ten electrodes, or so that nine of the ten positions were allocated to the frequencies up to 2600 Hz. Two additional conditions utilizing all available electrode positions (15-18 electrodes) were assessed: one with each subject's usual frequency-to-electrode allocation; and the other using the same analysis filters as the other experimental conditions. Seven users of the Nucleus CI22 implant wore processors mapped with each experimental condition for 2-week periods away from the laboratory, followed by assessment of perception of words in quiet and sentences in noise. Performance with both ten-electrode maps was significantly poorer than with both full-electrode maps on at least one measure. Performance with the map allocating nine out of ten electrodes to low frequencies was equivalent to that with the full-electrode maps for vowel perception and sentences in noise, but was worse for consonant perception. Performance with the evenly allocated ten-electrode map was equivalent to that with the full-electrode maps for consonant perception, but worse for vowel perception and sentences in noise. Comparison of the two full-electrode maps showed that subjects could fully adapt to frequency shifts up to ratio changes of 1.3, given 2 weeks' experience. Future research is needed to investigate whether speech perception may be improved by the manipulation of frequency-to-electrode allocation in maps which have a full complement of electrodes in Nucleus implants.

Adult↗

Electricity production by Geobacter sulfurreducens attached to electrodes.

Previous studies have suggested that members of the Geobacteraceae can use electrodes as electron acceptors for anaerobic respiration. In order to better understand this electron transfer process for energy production, Geobacter sulfurreducens was inoculated into chambers in which a graphite electrode served as the sole electron acceptor and acetate or hydrogen was the electron donor. The electron-accepting electrodes were maintained at oxidizing potentials by connecting them to similar electrodes in oxygenated medium (fuel cells) or to potentiostats that poised electrodes at +0.2 V versus an Ag/AgCl reference electrode (poised potential). When a small inoculum of G. sulfurreducens was introduced into electrode-containing chambers, electrical current production was dependent upon oxidation of acetate to carbon dioxide and increased exponentially, indicating for the first time that electrode reduction supported the growth of this organism. When the medium was replaced with an anaerobic buffer lacking nutrients required for growth, acetate-dependent electrical current production was unaffected and cells attached to these electrodes continued to generate electrical current for weeks. This represents the first report of microbial electricity production solely by cells attached to an electrode. Electrode-attached cells completely oxidized acetate to levels below detection (<10 micro M), and hydrogen was metabolized to a threshold of 3 Pa. The rates of electron transfer to electrodes (0.21 to 1.2 micro mol of electrons/mg of protein/min) were similar to those observed for respiration with Fe(III) citrate as the electron acceptor (E(o)' =+0.37 V). The production of current in microbial fuel cell (65 mA/m(2) of electrode surface) or poised-potential (163 to 1,143 mA/m(2)) mode was greater than what has been reported for other microbial systems, even those that employed higher cell densities and electron-shuttling compounds. Since acetate was completely oxidized, the efficiency of conversion of organic electron donor to electricity was significantly higher than in previously described microbial fuel cells. These results suggest that the effectiveness of microbial fuel cells can be increased with organisms such as G. sulfurreducens that can attach to electrodes and remain viable for long periods of time while completely oxidizing organic substrates with quantitative transfer of electrons to an electrode.

Culture Media↗

Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode.

INTRODUCTION: Preservation of residual hearing in cochlear implant recipients has been demonstrated to be possible and provides the potential benefit of combined electric and acoustic auditory stimulation. A prototype 16-mm multichannel array has been designed to facilitate placement of 22 electrodes without damage to intracochlear structures. The electrode array is suitable for insertion via the round window membrane (RWM) or a small cochleostomy. AIM: To evaluate the insertion trajectory and the presence of trauma to intracochlear structures with the prototype electrode inserted by either the RWM or a scala tympani cochleostomy. MATERIALS AND METHODS: Eighteen fresh frozen human temporal bones were prepared for cochlear implantation using a standard transmastoid facial recess technique. Twelve electrodes were implanted at the University of Melbourne and 6 at the Medizinische Hochschule Hannover. In Melbourne fluoroscopy was used to monitor the insertions. Twelve prototype electrodes were inserted via the RWM. A further 6 electrodes were inserted via a small scala tympani cochleostomy. The cochleostomy was sited inferior to the RWM to avoid trauma to the basilar membrane and spiral ligament. Specimens were embedded and fixed with acrylic resin and the cochleae then examined histologically at 200-mum intervals using a grinding and polishing technique. RESULTS: Full insertion of the electrode was achieved without significant resistance in all RWM and cochleostomy specimens. In two RWM specimens fold-over of the electrode tip occurred, and in one specimen the electrode penetrated the spiral ligament to lie in an 'endosteal 'position. In one cochleostomy specimen the electrode was rotated within the cochlea to face laterally rather than towards the modiolus. The final electrode position differed for the two groups, with the electrodes inserted via the RWM lying in a more perimodiolar position along the first part of the basal turn. The average depth of insertion was 240 degrees for the RWM electrodes and 255 degrees for the cochleostomy electrodes. Histologic examination showed no damage in any specimen to the modiolus, osseous spiral lamina or basilar membrane. CONCLUSIONS: A prototype hearing preservation electrode array was inserted by either a RWM or a scala tympani cochleostomy without evidence of significant intracochlear trauma.

Basilar Membrane↗

An active electrode for biopotential recording from small localized bio-sources.

BACKGROUND: Laser bio-stimulation is a well-established procedure in Medical Acupuncture. Nevertheless there is still a confusion as to whether it works or the effect is just placebo. Although a plethora of scientific papers published, showing positive clinical results, there is still a lack of objective scientific proofs about the bio-stimulation effect of lasers used in Acupuncture. The objective of this work was to design and build a body surface electrode and an amplifier for biopotential recording from acupuncture points, considered here as small localized bio-sources (SLB). The design is aimed for studying SLB potentials provoked by laser stimulus, in search for objective proofs of the bio-stimulation effect of lasers used in Medical Acupuncture. METHODS: The active electrode presented features a new adjustable anchoring system and fractionation of the biopotential amplifier between the electrode and the cabinet's location. The new adjustable electrode anchoring system is designed to reduce the electrode-skin contact impedance, its variation and motion artifacts. That is achieved by increasing the electrode-skin tension and decreasing its relative movement. Additionally the sensing element provides local constant skin stretching thus eliminating the contribution of the skin potential artifact. The electrode is attached to the skin by a double-sided adhesive pad, where the sensing element is a stainless steel, 4 mm in diameter. The fractionation of the biopotential amplifier is done by incorporating the amplifier's front-end op-amps at the electrodes, thus avoiding the use of extra buffers. The biopotential amplifier features two selectable modes of operation: semi-AC-mode with a -3 dB bandwidth of 0.32-1000 Hz and AC-mode with a bandwidth of 0.16-1000 Hz. RESULTS: The average measured DC electrode-skin contact impedance of the proposed electrode was 450 kOmega, with electrode tension of 0.3 kg/cm2 on an unprepared skin of the inner forearm. The peak-to-peak noise voltage measured at the amplifier output, with input terminals connected to common, was 10 mVp-p, or 2 microVp-p referred to the input. The common-mode rejection ratio of the amplifier was 96 dB at 50 Hz, measured with imbalanced electrodes' impedances. The prototype was also tested practically and sample records were obtained after a low intensity SLB laser stimulation. All measurements showed almost a complete absence of 50 Hz interference, although no electrolyte gel or skin preparation was applied. CONCLUSION: The results showed that the new active electrode presented significantly reduced the electrode-skin impedance, its variation and motion artifact influences. This allowed SLB signals with relatively high quality to be recorded without skin preparation. The design offers low noise and major reduction in parts, size and power consumption. The active electrode specifications were found to be better or at least comparable to those of other existing designs.

Acupuncture Points↗

Ag-AgCl electrode noise in high-resolution ECG measurements.

The authors measured the noise and impedance from face-to-face Ag-AgCl electrode pairs, as well as the noise from Ag-AgCl electrodes placed on the human body surface, in the frequency band from 0.5 Hz to 500 Hz, which corresponds to high-resolution ECG measurements. Electrode noise and electrode impedance were measured simultaneously to compare electrode noise with the thermal noise from the real part of electrode impedance. The results show that electrode noise depends on electrode area, electrolytic gel, the patient, and the placement site. In the frequency band from 0.5 Hz to 500 Hz, root-mean-square electrode noise is typically less than 1 microV for electrodes placed face-to-face and ranges from 1 microV to 15 microV for electrodes on the body surface. The noise spectral density increases at low frequencies as 1/fa and it is always higher than the thermal noise from the real part of the electrode impedance. There is a high correlation between electrode dc offset voltage and electrode noise. Thus, offset voltage measurements allow identification of noise from low-noise electrodes.

Algorithms↗

[Comparison of microwave coagulation using a new type electrode with radiofrequency ablation in the liver of living animals].

In the present study, we compared microwave coagulation using a new type of electrode, a teflon-coated electrode that was developed in order to increase the area of coagulation, with radiofrequency ablation using a Radionics Cool-tip electrode inserted into the pig liver. Two Landrace male pig were put under general anesthesia. A microwave electrode (insulated area: 6 mm, teflon-coated electrode 16 G) and a radiofreqency (RF) electrode (Cool-tip RF single electrode 17 G) were passed through the surface of the livers of the pig. A thermometer was placed 1 cm from the tip of the electrode in order to measure the changes in the temperature of the area surrounding the electrode. In this study, the microwave setting was 80 W, and the RF pulse was set automatically. The coagulated and ablated areas of the liver were measured after 2.5, 5, and 10 minutes of energy delivery (n = 4). The diameter of the coagulated area of the liver following 2.5, 5 and 10 minutes of microwave exposure was 23.5 +/- 4.8 mm, 29.5 +/- 5.2 mm and 32.5 +/- 6.4 mm, respectively. On the other hand, the diameter of the ablated area of the liver following 2.5, 5 and 10 minutes of RF exposure was 18.5 +/- 4.1 mm, 24 +/- 7.8 mm and 28 +/- 4.9 mm, respectively. The mean temperature of the liver 1 cm from the microwave and RF electrodes (measured time: 2 minutes) was 69.6 degrees C and 56.3 degrees C. respectively (n = 12). Thus, the temperature of the area surrounding the microwave electrode was significantly higher than the temperature of the area surrounding the RF electrode (p = 0.0065). The teflon-coated microwave electrode achieved superior results to the Radionics Cool-tip electrode with respect to the diameter of the coagulated area and the temperature of the area in which the electrode was inserted, at the specified times.

Animals↗

Subthalamic stimulation for Parkinson disease: determination of electrode location necessary for clinical efficacy.

OBJECT: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) performed using intraoperative microelectrode recording (MER) to adjust electrode placement has become a widely used treatment for patients with advanced Parkinson disease (PD). Few studies have been conducted to examine the location of implanted electrodes relative to the intended target, and even fewer have been undertaken to investigate the degree to which variations in the location of these electrodes impacts their clinical efficacy. This study was performed to examine these issues. METHODS: The authors located 52 bilaterally implanted DBS electrode tips on postoperative magnetic resonance (MR) images obtained in 26 consecutive patients. Postoperative and preoperative planning MR images were merged to determine the DBS electrode tip coordinates relative to the midcommissural point. Surgical records listed the intended target coordinates for each DBS electrode tip. Clinical outcome assessment included the Unified PD Rating Scale (UPDRS) motor score at 1 year, standardized questionnaires, and routine follow-up visits. The mean difference between electrode tip location and intended target for all 52 electrodes was less than 2 mm in all axes. Only one electrode was farther than 3 mm from the intended target, and this was the only electrode that had to be replaced due to lack of clinical efficacy (lack of tremor suppression); its reimplantation 4 mm more medially provided excellent tremor control. High correlation coefficients indicate that the MR imaging analysis accurately determined the anatomical location of the electrode tips. Blinded videotape reviews of UPDRS motor scores comparing effects of stimulation in patients who were "on" and "off" medication identified subgroups in whom there was minimal and maximal stimulation response. Patients in these subgroups had no differences between the MR imaging-determined actual electrode tip location and its intended location. Similarly, improvements of dyskinesias and severity of symptoms encountered during the wearing-off period for the drug did not correlate with variations of electrode tip location. CONCLUSIONS: The findings in this study lead the authors to suggest that a DBS electrode placed anywhere within a 6-mm-diameter cylinder centered at the presumed middle of the STN (based on stereotactic atlas coordinates) provides similar clinical efficacy. Future studies may be warranted to evaluate prospectively the degree to which MER modification of the anatomically and/or image-determined target improves clinical efficacy of DBS electrodes.

Adult↗

A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques.

A sol-gel electrode and a coated wire ion-selective poly(vinyl chloride) membrane, based on thiosemicarbazone as a neutral carrier, were successfully developed for the detection of Cu (II) in aqueous solutions. The sol-gel electrode and coated electrode exhibited linear response with Nernstian slopes of 29.2 and 28.1 mV per decade respectively, within the copper ion concentration ranges 1.0 x 10(-5) - 1.0 x 10(-1) M and 6.0 x 10(-6) - 1.0 x 10(-1) M for coated and sol-gel sensors. The coated and sol-gel electrodes show detection limits of 3.0 x 10(-6) and 6.0 x 10(-6) M respectively. The electrodes exhibited good selectivities for a number of alkali, alkaline earth, transition and heavy metal ions. The proposed electrodes have response times ranging from 10-50 s to achieve a 95% steady potential for Cu2+ concentration. The electrodes are suitable for use in aqueous solutions over a wide pH range (4-7.5). Applications of these electrodes for the determination of copper in real samples, and as an indicator electrode for potentiometric titration of Cu2+ ion using EDTA, are reported. The lifetimes of the electrodes were tested over a period of six months to investigate their stability. No significant change in the performance of the sol-gel electrode was observed over this period, but after two months the coated wire copper-selective electrode exhibited a gradual decrease in the slope. The selectivity of the sol-gel electrode was found to be better than that of the coated wire copper-selective electrode. Based on these results, a novel sol-gel copper-selective electrode is proposed for the determination of copper, and applied to real sample assays.

Journal Article↗

Effects of electrode density and electrolyte spreading in dense array electroencephalographic recording.

OBJECTIVE: High-density EEG recording offers increased spatial resolution but requires careful consideration of how the density of electrodes affects the potentials being measured. Power differences as a function of electrode density and electrolyte spreading were examined and a method for correcting these differences was tested. METHODS: Separate EEG recordings from 8 participants were made using a high-density electrode net, first with 6 of 128 electrodes active followed by recordings with all electrodes active. For a subset of 4 participants measurements were counterbalanced with recordings made in the reversed order by drying the hair after the high-density recordings and using a fresh dry electrode net of the same size for the low-density recordings. Mean power values over 6 resting eyes open/closed EEG recordings at the 6 active electrodes common to both recording conditions were compared. Evidence for possible electrolyte spreading or bridging between electrodes was acquired by computing Hjorth electrical distances. Spherical spline interpolation was tested for correcting power values at electrodes affected by electrolyte spreading for these participants and for a subset of participants from a larger previous study. RESULTS: For both the complete set and the counterbalanced subset, significant decreases in power at the 6 common electrodes for the high-density recordings were observed across the range of the standard EEG bands (1-44 Hz). The number of bridges or amount of electrolyte spreading towards the reference electrode as evidenced by small Hjorth electrical distances served as a predictor of this power decrease. Spherical spline interpolation increased the power values at electrodes affected by electrolyte spreading and by a significant amount for the larger number of participants in the second group. CONCLUSIONS: Understanding signal effects caused by closely spaced electrodes, detecting electrolyte spreading and correcting its effects are important considerations for high-density EEG recordings. A combination of scalp maps of power density and plots of small Hjorth electrical distances can be used to identify electrodes affected by electrolyte spreading. Interpolation using spherical splines offers a method for correcting the potentials measured at these electrodes.

Adult↗

Sensitivity of recordings at sphenoidal electrode site for detecting seizure onset: evidence from scalp, superficial and deep foramen ovale recordings.

OBJECTIVES: Some authors have recently stressed that the position of the tip of sphenoidal electrodes plays a crucial role in their efficacy in detecting ictal onset. An opportunity to test this hypothesis is provided by recordings from the most superficial contacts of foramen ovale (FO) electrode bundles because these contacts are located at the FO, in a position equivalent to that of optimally located sphenoidal electrodes. To simplify wording, recordings obtained by superficial FO electrodes will hereafter be called sphenoidal recordings, although they have not been obtained with standard sphenoidal electrodes. The sensitivities of simultaneous scalp and sphenoidal recordings for detecting ictal onset have been compared with each other, and with a 'gold standard' provided by simultaneous deep intracranial FO recordings from the mesial aspect of the temporal lobe. METHODS: Three hundred and fourteen seizures obtained from 110 patients under telemetric presurgical assessment for temporal lobe epilepsy have been studied. Scalp electrodes included anterior temporal placements. All scalp electrodes were considered when identifying seizure onset but the anterior temporal electrodes were most frequently involved. RESULTS: Ictal onset time at sphenoidal and scalp recordings: initial ictal changes appeared simultaneously in scalp and sphenoidal recordings in 123 seizures (39.2%). Initial changes occurred earlier in sphenoidal recordings in 63 seizures (20.1%), whereas they were seen earlier on the scalp in 76 seizures (24.2%). Artefacts prevented the comparison between sphenoidal and scalp recordings in 16 seizures (5.1%) and no ictal changes were seen on the scalp and/or sphenoidal recordings in 36 seizures (11.5%). In most of the 63 seizures where ictal changes appeared earlier in sphenoidal recordings, a delayed ipsilateral scalp onset was seen as the signal amplitude increased or scalp changes could be identified retrospectively on the scalp with an onset which appeared simultaneous and ipsilateral to the initial sphenoidal changes. Sphenoidal recordings supplied additional information when compared to scalp recordings in only 22 seizures (7%): in 5 seizures with artefacts on the scalp, in 6 seizures with no changes on the scalp and in 11 seizures with discrepant laterality at onset. Congruence in laterality with respect to deep intracraneal FO recordings: of the 61 seizures with unilateral onset on the scalp, onsets at sphenoidal recordings and deep FO electrodes were ipsilateral in most cases. In only 3 of these 61 seizures (4.9%), sphenoidal recordings lateralized ipsilateral to the deep FO electrodes in the presence of a contralateral onset on the scalp. In 14 among the 122 seizures (11.5%) with bilateral asymmetrical onset on the scalp, sphenoidal recordings lateralized seizure onset ipsilateral to the deep FO electrodes in the presence of a contralateral scalp onset. Thus, when compared with scalp EEG, sphenoidal recordings increased laterality congruence with respect to deep FO electrodes in 17 seizures (5.4%). CONCLUSIONS: Extracranial electrodes located next to the FO at the sphenoidal electrode site yield an improvement over suitable surface electrodes in the identification of ictal onset in only 5.4-7% of seizures. Such improvement derives from the fact that the low amplitude signals often seen at seizure onset may show higher amplitude on sphenoidal than on scalp recordings.

Electroencephalography↗

CMUTS with dual-electrode structure for improved transmit and receive performance.

In this paper, we introduce capacitive micro-machined ultrasonic transducers (CMUTs) with electrically isolated multiple electrodes embedded in the same silicon nitride CMUT membrane. Some of the advantages of this structure are demonstrated using a dual-electrode CMUT with separate transmit and receive electrodes as an example. By locating the transmit electrodes near the edges of a rectangular CMUT membrane, the stable displacement range, hence the maximum pressure amplitude during transmit mode is increased without collapsing the membrane when operated within static collapse voltage range. In the receive mode, the center receive electrode is brought closer to the substrate by biasing the side electrodes, and a higher electromechanical transformer ratio is obtained at low direct current (DC) bias. Therefore, dual-electrode CMUT has an effectively larger gap as compared to conventional CMUT during transmit, and it has an effectively smaller gap during receive. Demonstrative experiments are performed on dual-electrode CMUTs with rectangular membranes with different side and center electrode sizes for transmit and receive measurements. By using the two 4-microm wide side electrodes and an 8-microm wide center electrode on a 20-microm wide membrane, a 6.8 dB increase in maximum output pressure is obtained with side electrode excitation as compared to conventional center electrode. Similarly, the receive performance improvement was demonstrated while reducing the DC bias requirements. Simple finite-element and equivalent circuit-based models were developed to successfully model the behavior of dual-electrode CMUTs. Simulations show that, with simple modifications, more than 10 dB overall sensitivity improvement is feasible with dual-electrode CMUTs with rectangular membranes.

Computer-Aided Design↗

Forward masking patterns produced by intracochlear electrical stimulation of one and two electrode pairs in the human cochlea.

Three psychophysical forward masking studies were conducted on a multichannel cochlear implant patient. The first study investigated the masking pattern produced by a bipolar electrode pair at different stimulus currents. It was found that the masking pattern for a single-masker bipolar electrode pair had a maximum located at an electrode position where the masker and probe coincided. The spread of the masking pattern was not symmetrical about the maximum. The amount of masking decreased very rapidly toward the apical direction and less rapidly toward the basal direction from the position of the maximum. As the stimulus current increased, the amount of masking at the maximum increased and the masking pattern broadened toward the base. The second study investigated the masking pattern produced by the activation of single bipolar electrode pairs with different spatial extents. The spatial extent of a bipolar electrode pair is defined as the distance between the apical and basal electrode members of the bipolar pair. With a small spatial extent (1.5 mm), the more basal electrode pairs (higher threshold and smaller dynamic range) produced broader masking patterns than the more apical electrode pairs (lower threshold and wider dynamic range), suggesting that there was more current spread at the basal region. With a larger spatial extent (4.5 mm), an additional secondary masking maximum was observed in the vicinity of the apical electrode member of the masker; this was observed only when the apical electrode member lay within the low-threshold apical region. The third study investigated the masking patterns produced by two loudness balanced bipolar masker electrode pairs activated within a stimulus period (inverse of the pulse repetition rate). The biphasic current pulses delivered to the two electrode pairs were nonoverlapping in time. It was found that, at any probe electrode position, the amount of masking produced by the two combined bipolar electrode pairs approximately followed the greater of the two maskings produced respectively by the two individual bipolar masker electrode pairs.

Cochlea↗

Implications of deep electrode insertion on cochlear implant fitting.

Using long Med-El Combi40+ electrode arrays, it is now possible to cover the whole range of the cochlea, up to about two turns. Such insertion depths have received little attention. To evaluate the contribution of deeply inserted electrodes, five Med-El cochlear implant users were tested on vowel and consonant identification tests with fittings with first one, two, and up to five apical electrodes being deactivated. In addition, subjects performed pitch-ranking experiments, using loudness-balanced stimuli, to identify electrodes creating pitch confusions. Radiographs were taken to measure each electrode insertion depth. All subjects used each modified fitting for two periods of about 3 weeks. During the experiment, the same stimulation rate and frequency range were maintained across all the fittings used for each individual subject. After each trial period the subject had to perform three consonant and three vowel identification tests. All subjects showed deep electrode insertions ranging from 605 degrees to 720 degrees. The two subjects with the deepest electrode insertions showed significantly increased vowel- and consonant-identification performances with fittings with the two or three most apical electrodes deactivated compared to their standard fitting with all available electrodes activated. The other three subjects did not show significant improvements in performance when one or two of their most apical electrodes were deactivated. Four out of five subjects preferred to continue use of a fitting with one or more apical electrodes deactivated. The two subjects with the deepest insertions also showed pitch confusions between their most apical electrodes. Two possible reasons for these results are discussed. One is to reduce neural interactions related to electrodes producing pitch confusions. Another is to improve the alignment of the frequency components of sounds coded by the electrical signals delivered to each electrode to the overall pitch of the auditory perception produced by the electrical stimulation of auditory nerve fibers.

Adult↗

Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation.

Histological studies have shown that the Melbourne/Cochlear electrode array lies along the outer wall of the scala tympani and is therefore some distance from the residual VIIIth nerve elements. In order to investigate the influence of electrode position on neural excitation we systematically varied the position of the electrode array within the cat scala tympani while recording electrically evoked auditory brainstem responses (EABRs). Using both normal hearing and long-term deafened animals, we observed significant reductions in EABR thresholds as the electrode array was moved from the outer wall towards the modiolus. Further threshold reductions were observed when the array was placed underneath the osseous spiral lamina (OSL) close to the peripheral dendrites. These changes were independent of the bipolar inter-electrode separation, and were observed over a wide range of cochlear pathologies varying from normal to a moderate spiral ganglion cell loss. Interestingly, the one animal exhibiting extensive neural loss showed no correlation between EABR threshold and electrode position. There was also a general decrease in the gradient of the EABR input-output function as the electrode array was moved closer to the neural elements. This was, however, only statistically significant when the electrode was positioned adjacent to the peripheral dendrites. Significant reductions in EABR threshold were also observed as the inter-electrode spacing of the bipolar electrodes was increased. The gradient of the EABR input-output function also increased with increasing inter-electrode spacing, although again, this was only significant when the electrode array was positioned close to the neural elements. The present results indicate that the optimum placement of a Melbourne/Cochlear electrode array is adjacent to the peripheral dendrites. However, such a site would be difficult to achieve in practice while minimizing insertion trauma. An array lying adjacent to the modiolus would be a safe alternative while ensuring a significant reduction in threshold compared with the existing site (outer wall). This placement should result in more localized neural excitation patterns, an increase in the number of bipolar electrodes available, together with an increase in their dynamic range. These changes may lead to further improvements in speech perception among cochlear implant patients.

Animals↗

Remediation and recovery of uranium from contaminated subsurface environments with electrodes.

Previous studies have demonstrated that Geobacter species can effectively remove uranium from contaminated groundwater by reducing soluble U(VI) to the relatively insoluble U(IV) with organic compounds serving as the electron donor. Studies were conducted to determine whether electrodes might serve as an alternative electron donor for U(VI) reduction by a pure culture of Geobacter sulfurreducens and microorganisms in uranium-contaminated sediments. Electrodes poised at -500 mV (vs a Ag/AgCl reference) rapidly removed U(VI) from solution in the absence of cells. However, when the poise at the electrode was removed, all of the U(VI) returned to solution, demonstrating that the electrode did not reduce U(VI). If G. sulfurreducens was present on the electrode, U(VI) did not return to solution until the electrode was exposed to dissolved oxygen. This suggeststhat G. sulfurreducens on the electrode reduced U(VI) to U(IV) which was stably precipitated until reoxidized in the presence of oxygen. When an electrode was placed in uranium-contaminated subsurface sediments, U(VI) was removed and recovered from groundwater using poised electrodes. Electrodes emplaced in flow-through columns of uranium-contaminated sediments readily removed U(VI) from the groundwater, and 87% of the uranium that had been removed was recovered from the electrode surface after the electrode was pulled from the sediments. These results suggest that microorganisms can use electrons derived from electrodes to reduce U(VI) and that it may be possible to remove and recover uranium from contaminated groundwater with poised electrodes.

Biodegradation, Environmental↗

An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes.

PURPOSE: To determine optimal parameters for bipolar radiofrequency ablation (RFA) using perfusion-cooled electrodes to create a large ablation volume in ex vivo bovine liver. MATERIAL AND METHODS: Three sets of RF experiments were performed using a 200-Watt generator and two 15-gauge perfusion-cooled or internally cooled electrodes in ex vivo bovine livers. In the first set of experiments, to find the ideal inter-electrode distance for creating large coagulation necrosis, 30 ablation lesions were created by bipolar RFAs at inter-electrode spacings of 3 cm, 4 cm, and 5 cm. In the second set of experiments, to explore the ideal duration of RF application, bipolar RFAs were performed for 10 min and 20 min. In the first and second experiments, 10 lesions were made for each condition with infusion of 6% hypertonic saline (HS) at 2 ml/min. In the third set of experiments, 10 ablation lesions were created by bipolar RFAs using internally cooled electrodes without HS infusion. The mean volume of those ablation lesions was then compared to that of the lesions created by bipolar RFA using perfusion-cooled electrodes in the second experiments. Tissue impedance, dimension, and shape of the ablated areas were compared in each condition. RESULTS: In the first set of experiments, bipolar RFA created a homogeneous oval or spherical-shaped ablation area between the electrodes at 3-5 cm spacing, but showed a more spherical-shaped lesion at 3 cm inter-electrode spacing than at 4 cm and 5 cm spacing. In the second set of experiments, RF energy delivered for 20 min created a larger dimension of coagulation necrosis than energy delivered for 10 min: 107.6 +/- 34 cm3 versus 59.5 +/- 27 cm3 (P<0.05). In addition, the mean volume of ablation regions obtained with bipolar RFA using the internally cooled electrode was 47.5+/- 17 cm3, which was significantly less than that with bipolar RFA using perfusion-cooled electrodes (P <0.05). CONCLUSION: Bipolar RFA using perfusion-cooled electrodes achieves homogeneous areas of coagulation necrosis between two electrodes, preferably at 3 or 4 cm inter-electrode distance for 20 min, and is better in creating large coagulation necrosis than bipolar RFA using internally cooled electrodes.

Analysis of Variance↗

Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance.

OBJECTIVE: The study investigated the hypothesis that threshold and comfortable levels recorded from cochlear implant patients would reduce, and dynamic range increase, as distance of the electrode from the modiolar wall (radial distance) decreases. Two groups of cochlear implant patients participated; one group using the Nucleus' 24 Contour electrode array, and one group using the Nucleus standard straight (banded) array. The Nucleus 24 Contour array has been shown in temporal bone studies to lie closer to the modiolus than the banded array. The relationship of electrode impedance and radial distance is also investigated. DESIGN: The study, conducted at three centers, evaluated 21 patients using the Contour array, and 36 patients using the banded array. For each patient, threshold, comfortable levels and dynamic range were measured at four time points. Common ground electrode impedance was recorded clinically from each patient, at time intervals up to 12 wk. An estimate of the radial distance of the electrode from the modiolus was made by analysis of Cochlear view x-rays. RESULTS: Threshold and comfortable levels were significantly lower for the Nucleus 24 Contour array than for the banded array. However, dynamic range measurements did not show the predicted increase. In a majority of subjects, a significant correlation was found between the estimated radial distance of the electrode from the modiolus and the measured threshold and comfortable levels. This trend was not observed for dynamic range. The analysis indicates that other factors than radial distance are involved in the resultant psychophysical levels. Clinical impedance measures (common ground) were found to be significantly higher for the Contour array. However, the electrodes on the Contour array are half-rings, which are approximately only half the geometric size of the full rings as electrodes of the standard array. When the geometric electrode area in the two array designs are normalized, the trends in the electrode impedance behavior are similar. CONCLUSIONS: The results support the hypothesis that the relationship between the radial distance of the electrode and the psychophysical measures are influenced by patterns of fibrous tissue growth and individual patient differences, such as etiology and neural survival. Impedance measures for the Nucleus 24 Contour electrode array were higher than the banded electrode array, but this is primarily due to the reduction in electrode surface area. The different outcomes in impedance over time suggest differences in the relative contributions of the components of impedance with the two arrays.

Acoustic Impedance Tests↗