Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

A gene-specific DNA sequencing chip for exploring molecular evolutionary change.

Sequencing by hybridization (SBH) approaches to DNA sequencing face two conflicting constraints. First, in order to ensure that the target DNA binds reliably, the oligonucleotide probes that are attached to the chip array must be >15 bp in length. Secondly, the total number of possible 15 bp oligonucleotides is too large (>4(15)) to fit on a chip with current technology. To circumvent the conflict between these two opposing constraints, we present a novel gene-specific DNA chip design. Our design is based on the idea that not all conceivable oligonucleotides need to be placed on a chip--only those that capture sequence combinations occurring in nature. Our approach uses a training set of aligned sequences that code for the gene in question. We compute the minimum number of oligonucleotides (generally 15-30 bp in length) that need to be placed on a DNA chip to capture the variation implied by the training set using a graph search algorithm. We tested the approach in silico using cytochrome-b sequences. Results indicate that on average, 98% of the sequence of an unknown target can be determined using the approach.

Algorithms↗

Children's Interview for Psychiatric Syndromes (ChIPS).

OBJECTIVE: To describe the development and summarize the psychometric properties of the Children's Interview for Psychiatric Syndromes (ChIPS). METHOD: ChIPS is a highly structured interview designed for use by trained lay interviewers in children aged 6-18 years. It screens for 20 Axis I disorders as well as psychosocial stressors. Questions use simple language and short sentence structure to enhance subject comprehension and cooperation. The interview is based on DSM-IV and results are presented in a concise, easy-to-interpret manner. There are both child and parent versions. The psychometric properties of each version were studied. RESULTS: A series of 5 studies has demonstrated the validity of the DSM-III, DSM-III-R, and DSM-IV versions of the ChIPS as well as the validity of the P-ChIPS (parent version). Administration time is relatively brief, averaging 49 minutes for inpatients, 30 minutes for outpatients, and 21 minutes for a community-based sample. CONCLUSIONS: ChIPS can be used as a screening instrument to maximize a clinician's efficiency, as a diagnostic instrument in clinical research, and as a training instrument to help mental health professionals learn psychiatric diagnosis. It can also be used in epidemiological research.

Adolescent↗

The Child Report Form of the CHIP-Child Edition: reliability and validity.

BACKGROUND: There is increasing recognition of the importance of obtaining children's reports of their health, but significant challenges must be overcome to do so in a systematic, population-based manner. OBJECTIVE: The objective of this study was to present the initial tests of the Child Report Form of the Child Health and Illness Profile-Child Edition (CHIP-CE/CRF), a self-report health status instrument for children 6 to 11 years old. METHODS: Three studies iteratively evaluated revisions of the CHIP-CE/CRF in 4 geographic locations in the United States. Children (N=1708) whose families represent the low to middle socioeconomic strata and predominant U.S. racial/ethnic groups were involved. RESULTS: The final CHIP-CE/CRF includes 5 domains: Satisfaction (with self and health), Comfort (emotional and physical symptoms and limitations), Resilience (positive activities that promote health), Risk Avoidance (risky behaviors that influence future health), and Achievement (of social expectations in school and with peers). The internal consistency and test-retest reliability of the domains are good to excellent, with a definite age gradient such that younger children's responses are less reliable although still acceptable. Validity is supported through criterion and construct validity tests and structural analyses. Standard scores (mean, 50; standard deviation, 10) were established. CONCLUSIONS: Health status can be reliably and validly assessed directly from children 6 to 11 years old on the CHIP-CE/CRF. In combination with the CHIP-AE, self-reported health status can now be obtained from youth 6 to 18 years old using a consistent conceptual framework. This can greatly improve the precision and comparability of health assessments of youth, enhancing the validity of outcome research and longitudinal studies across childhood and adolescence.

Adaptation, Psychological↗

Perforated silicon nerve chips with doped registration electrodes: in vitro performance and in vivo operation.

An in vitro model was developed for the study of signal transduction between a Cu-wire, miming a neural signal source, and recording electrodes on perforated silicon chips. Phosphorous doped electrodes were used to achieve an all silicon device. The model was used to study signal amplitude as a function of the spatial position, and distance to the signal source. Recordings of the signal crosstalk to neighboring electrodes on the chips were made. It was found that the amplitude decreased by a factor of two at a distance of 50 microns between the electrode surface and the signal source. The chip electrode signal crosstalk was found to be 6 dB using an external reference electrode. Improvements were accomplished with an on chip reference electrode giving a crosstalk suppression of 20 dB. Impedance analysis showed that doped silicon electrodes displayed similar characteristics as Cu-electrodes at frequencies above 3 kHz. Sieve electrodes were implanted in the rat sciatic nerve and following a 10-week nerve regeneration period the dorsal and ventral (L5) roots in the spinal cord were stimulated. Compound action potentials were recorded via the chip. Stimulating the regenerated sciatic nerve via the sieve electrode also induced lower leg muscle contraction activity.

Action Potentials↗

Dynamic ion channel activation scheduling in patch clamp on a chip.

In 2002, Fertig et al. made a remarkable invention: the first successful demonstration of a patch clamp on a chip--a planar quartz-based biological chip that contains up to several hundred ion channels. This patch-clamp chip can be used in massively parallel screens for ion channel activity, thereby providing a high-throughput screening tool for drug discovery efforts. In this paper, we propose computationally efficient dynamic stochastic scheduling algorithms for activating individual ion channels in the patch-clamp chip. By formulating the ion channel activation scheduling problem as a partially observed Markov decision process with a multiarmed bandit structure, near-optimal dynamic scheduling for activation of the individual channels is achieved to optimize the information gained from the patch-clamp chip. Numerical examples using state-of-the-art algorithms developed recently in artificial intelligence and operations research are presented to illustrate these dynamic ion channel (macromolecule) activation scheduling algorithms.

Algorithms↗

A simple and reliable assay for detecting specific nucleotide sequences in plants using optical thin-film biosensor chips.

Here we report the adaptation and optimization of an efficient, accurate and inexpensive assay that employs custom-designed silicon-based optical thin-film biosensor chips to detect unique transgenes in genetically modified (GM) crops and SNP markers in model plant genomes. Briefly, aldehyde-attached sequence-specific single-stranded oligonucleotide probes are arrayed and covalently attached to a hydrazine-derivatized biosensor chip surface. Unique DNA sequences (or genes) are detected by hybridizing biotinylated PCR amplicons of the DNA sequences to probes on the chip surface. In the SNP assay, target sequences (PCR amplicons) are hybridized in the presence of a mixture of biotinylated detector probes and a thermostable DNA ligase. Only perfect matches between the probe and target sequences, but not those with even a single nucleotide mismatch, can be covalently fixed on the chip surface. In both cases, the presence of specific target sequences is signified by a color change on the chip surface (gold to blue/purple) after brief incubation with an anti-biotin IgG horseradish peroxidase (HRP) to generate a precipitable product from an HRP substrate. Highly sensitive and accurate identification of PCR targets can be completed within 30 min. This assay is extremely robust, exhibits high sensitivity and specificity, and is flexible from low to high throughput and very economical. This technology can be customized for any nucleotide sequence-based identification assay and widely applied in crop breeding, trait mapping, and other work requiring positive detection of specific nucleotide sequences.

Alleles↗

Early expression of SCIN and CHIPS drives instant immune evasion by Staphylococcus aureus.

Chemotaxis inhibitory protein of staphylococci (CHIPS) and Staphylococcal complement inhibitor (SCIN) are small, excreted molecules that play a crucial role in the staphylococcal defence against the human innate immune system. Here we show that they both counteract crucial acute responses of our immune system such as complement activation, neutrophil chemotaxis and neutrophil activation. By studying gene expression via promoter-green fluorescent protein fusions, Northern blots and protein expression analyses, we show that SCIN and CHIPS are produced during the early (exponential) growth stages. Although the SCIN and CHIPS genes are expressed simultaneously, they are differently regulated by various Staphylococcus aureus regulatory loci. However, the sae locus is crucial for upregulation of both SCIN and CHIPS. This is the first study that presents the expression of two extracellular S. aureus proteins early during growth. Because SCIN and CHIPS are both efficient modulators of neutrophil chemotaxis, phagocytosis and killing, their early expression is necessary for efficient modulation of the early immune response.

Antigens, Bacterial↗

Biomedical applications of protein chips.

The development of microchips involving proteins has accelerated within the past few years. Although DNA chip technologies formed the precedent, many different strategies and technologies have been used because proteins are inherently a more complex type of molecule. This review covers the various biomedical applications of protein chips in diagnostics, drug screening and testing, disease monitoring, drug discovery (proteomics), and medical research. The proteomics and drug discovery section is further subdivided to cover drug discovery tools (on-chip separations, expression profiling, and antibody arrays), molecular interactions and signaling pathways, the identification of protein function, and the identification of novel therapeutic compounds. Although largely focused on protein chips, this review includes chips involving cells and tissues as a logical extension of the type of data that can be generated from these microchips.

Animals↗

A custom-built insulin resistance gene chip.

OBJECTIVES/AIM: Microarray (gene chip) technology offers a powerful new tool for analyzing the expression of large numbers of genes in many experimental samples. The aim of this study was to design, construct, and use a gene chip to measure the expression levels of key genes in metabolic pathways related to insulin resistance. METHODS: We selected genes that were implicated in the development of insulin resistance, including genes involved in insulin signaling; glucose uptake, oxidation, and storage; fat uptake, oxidation, and storage; cytoskeletal components; and transcription factors. The key regulatory genes in the pathways were identified, along with other recently identified candidate genes such as calpain-10. A total of 242 selected genes (including 32 internal control elements) were sequence-verified, purified, and arrayed on aldehyde-coated slides. RESULTS: Where more than 1 clone containing the gene of interest was available, we chose those containing the genes in the 5' orientation and an insert size of around 1.5 kb. Of the 262 clones purchased, 56 (21%) were found to contain sequences other than those expected. In addition, 2 (1%) did not grow under standard conditions and were assumed to be nonviable. In these cases, alternate clones containing the gene of interest were chosen as described above. The current version of the Insulin Resistance Gene Chip contains 210 genes of interest, plus 48 control elements. A full list of the genes is available at http://www.hbs.deakin.edu.au/mru/research/gene_chip_tech/genechip_three.htm/. CONCLUSIONS: The human Insulin Resistance Gene Chip that we have constructed will be a very useful tool for investigating variation in the expression of genes relevant to insulin resistance under various experimental conditions. Initially, the gene chip will be used in studies such as exercise interventions, fasting, euglycemic-hyperinsulinemic clamps, and administration of antidiabetic agents.

Base Sequence↗

PHYSICS: Toward Atom Chips.

As a novel approach for turning the peculiar features of quantum mechanics into practical devices, researchers are investigating the use of ultracold atomic clouds above microchips. Such "atom chips" may find use as sensitive probes for gravity, acceleration, rotation, and tiny magnetic forces. In their Perspective, Fortagh and Zimmermann discuss recent advances toward creating atom chips, in which current-carrying conductors in the chips create magnetic microtraps that confine the atomic clouds. Despite some intrinsic limits to the performance of atom chips, existing technologies are capable of producing atom chips, and many possibilities for their construction remain to be explored.

Journal Article↗

Use of the DNA flow-thru chip, a three-dimensional biochip, for typing and subtyping of influenza viruses.

Influenza A viruses, which are further subtyped on the basis of antigenic differences in external hemagglutinin and neuraminidase glycoproteins, and influenza B viruses are prominent among the viral causes of respiratory diseases and can cause a wide spectrum of illness. Each year these viruses are responsible for recurrent epidemics, frequently in association with genetic variation. There is a requirement for sensitive and rapid diagnostic techniques in order to improve both the diagnosis of infections and the quality of surveillance systems. A new three-dimensional biochip platform (Flow-Thru Chip; MetriGenix) was used to develop a rapid and reliable molecular method for the typing and subtyping of influenza viruses. Oligonucleotide probes immobilized in microchannels of a silicon wafer were selected to recognize multiple fragments of the influenza A virus matrix protein gene; the influenza B virus NS gene; the H1, H3, and H5 hemagglutinin genes; and the N1 and N2 neuraminidase genes. Biotinylated amplicons resulting from either multiplex or random reverse transcription-PCR were hybridized to arrayed oligonucleotides on the influenza virus chip before they were stained with horseradish peroxidase-streptavidin and were imaged by use of a chemiluminescent substrate. The chip analysis procedure, from the time of pipetting of the sample into the chip cartridge to the time of analysis of the results, was performed in less than 5 h. The random PCR exhibited a higher level of performance than the multiplex PCR in terms of the specificity of product hybridization to the influenza virus chip. Analysis of influenza A viruses (H1N1, H3N2, H1N2, and H5N1) and influenza B viruses showed that this microarray-based method is capable of the rapid and unambiguous identification of all types and subtypes of viruses by use of random PCR products. The redundancy of the probes designed for each gene selected yielded an additional criterion of confidence for the subtyping of viruses which are known for antigenic variations in some of their components.

Base Sequence↗

Human red cell aquaporin CHIP. I. Molecular characterization of ABH and Colton blood group antigens.

Blood group antigens are structural variants in surface carbohydrate or amino acid polymorphisms on extracellular domains of membrane proteins. The red cell water channel-forming integral protein (Aquaporin CHIP) is a homotetramer with only one N-glycosylated subunit, however no CHIP-associated blood group antigens have yet been identified. Immunoblotting, monosaccharide composition analysis, and selective glycosidase digestions revealed that the CHIP-associated oligosaccharide contains ABH determinants and resembles a band 3-type glycan that cannot be cleaved from intact membranes by Peptide:N-glycosidase F. The molecular structure of the Colton antigens was previously unknown, but CHIP was selectively immunoprecipitated with anti-Coa or anti-Co(b). The DNA sequence from Colton-typed individuals predicted that residue 45 is alanine in the Co(a+b-) phenotype and valine in the Co(a-b+) phenotype. The nucleotide polymorphism corresponds to a PflMI endonuclease digestion site in the DNA from Co(a-b+) individuals. These studies have defined antigens within two blood group systems on CHIP: (a) an ABH-bearing polylactosaminoglycan attached to a poorly accessible site in the native membrane; and (b) the Colton antigen polymorphism which may permit the identification of rare individuals with defective water channel expression.

ABO Blood-Group System↗

Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano-gold immunological amplification and silver staining method.

BACKGROUND: Viral hepatitis due to hepatitis B virus and hepatitis C virus are major public health problems all over the world. Traditional detection methods including polymerase chain reaction (PCR)-based assays and enzyme-linked immunosorbent assays (ELISA) are expensive and time-consuming. In our assay, a protein chip assay using Nano-gold Immunological Amplification and Silver Staining (NIASS) method was applied to detect HBV and HCV antibodies rapidly and simultaneously. METHODS: Chemically modified glass slides were used as solid supports (named chip), on which several antigens, including HBsAg, HBeAg, HBcAg and HCVAg (a mixture of NS3, NS5 and core antigens) were immobilized respectively. Colloidal nano-gold labelled staphylococcal protein A (SPA) was used as an indicator and immunogold silver staining enhancement technique was applied to amplify the detection signals, producing black image on array spots, which were visible with naked eyes. To determine the detection limit of the protein chip assay, a set of model arrays in which human IgG was spotted were structured and the model arrays were incubated with different concentrations of anti-IgG. A total of 305 serum samples previously characterized with commercial ELISA were divided into 4 groups and tested in this assay. RESULTS: We prepared mono-dispersed, spherical nano-gold particles with an average diameter of 15 +/- 2 nm. Colloidal nano-gold-SPA particles observed by TEM were well-distributed, maintaining uniform and stable. The optimum silver enhancement time ranged from 8 to 12 minutes. In our assay, the protein chips could detect serum antibodies against HBsAg, HBeAg, HBcAg and HCVAg with the absence of the cross reaction. In the model arrays, the anti-IgG as low as 3 ng/ml could be detected. The data for comparing the protein chip assay with ELISA indicated that no distinct difference (P > 0.05) existed between the results determined by our assay and ELISA respectively. CONCLUSION: Results showed that our assay can be applied with serology for the detection of HBV and HCV antibodies rapidly and simultaneously in clinical detection.

Hepacivirus↗

The design of a gene chip for functional immunological studies on a high-quality control platform.

We have created an immunology-related microarray chip containing primarily known genes with well-studied functional properties. By looking at known genes rather than expressed sequence tags, we hope to gain a better understanding of immunological pathways and how they work. The immunology gene chip contains genes from the following functional categories: T cell genes; B cell genes; dendritic cell genes; chemokine and cytokine genes; apoptosis genes; cell cycle genes; cell interaction genes; general hematology and immunology genes; and adhesion genes. We have also developed a novel three-color cDNA array platform in which arrays are directly visualized before hybridization, which allows us to select only high-quality chips for our experiments. In an effort to provide quantitative quality control for each array element as well as the entire chip, we have developed Matarray, a software package for image processing and data acquisition. With Matarray, we have built a quantitative data filtering and normalization scheme that has proved to be more efficient than the existing methods. The list of immunology chip genes is available from the authors.

Chemokines↗

Alternative effects of the ubiquitin-proteasome pathway on glucocorticoid receptor down-regulation and transactivation are mediated by CHIP, an E3 ligase.

The ubiquitin/proteasome-dependent protein degradation pathway (UPP) is responsible for the accelerated down-regulation of glucocorticoid receptor (GR) levels in cells subjected to chronic glucocorticoid exposure. Whereas hormone-dependent down-regulation of GR operates in most cells, the receptor is not down-regulated after long-term glucocorticoid treatment of either cultured embryonic hippocampal neurons or the HT22 hippocampal cell line. In this report, we show that stable overexpression of the carboxy terminus of heat shock protein 70-interacting protein (CHIP) E3 ligase can restore hormone-dependent down-regulation of GR in HT22 cells. Proteasome inhibitor studies establish that ubiquitylated GR can be efficiently engaged with the proteasome upon CHIP overexpression, unlike the case in parental HT22 cells. In addition to its impact on GR down-regulation, CHIP overexpression alters the coupling between the UPP and GR transactivation. Unlike other steroid receptors whose transactivation properties are typically reduced upon proteasome inhibition, GR transactivation in HT22 cells and other cell lines is enhanced upon proteasome inhibition. However, in HT22 cells overexpressing CHIP, proteasome inhibition leads to a reduction in GR transactivation activity. Thus, the divergent response of a single transactivator (i.e. GR) to the UPP can be dictated by CHIP, an E3 ligase that also functions as a proteasome-targeting factor.

Animals↗

Three-dimensional optoelectronic stacked processor by use of free-space optical interconnection and three-dimensional VLSI chip stacks.

We present a demonstration system under the three-dimensional (3D) optoelectronic stacked processor consortium. The processor combines the advantages of optics in global, high-density, high-speed parallel interconnections with the density and computational power of 3D chip stacks. In particular, a compact and scalable optoelectronic switching system with a high bandwidth is designed. The system consists of three silicon chip stacks, each integrated with a single vertical-cavity-surface-emitting-laser-metal-semiconductor-metal detector array and an optical interconnection module. Any input signal at one end stack can be switched through the central crossbar stack to any output channel on the opposite end stack. The crossbar bandwidth is designed to be 256 Gb/s. For the free-space optical interconnection, a novel folded hybrid micro-macro optical system with a concave reflection mirror has been designed. The optics module can provide a high resolution, a large field of view, a high link efficiency, and low optical cross talk. It is also symmetric and modular. Off-the-shelf macro-optical components are used. The concave reflection mirror can significantly improve the image quality and tolerate a large misalignment of the optical components, and it can also compensate for the lateral shift of the chip stacks. Scaling of the macrolens can be used to adjust the interconnection length between the chip stacks or make the system more compact. The components are easy to align, and only passive alignment is required. Optics and electronics are separated until the final assembly step, and the optomechanic module can be removed and replaced. By use of 3D chip stacks, commercially available optical components, and simple passive packaging techniques, it is possible to achieve a high-performance optoelectronic switching system.

Journal Article↗

Microarray-based detection of bacteria by on-chip PCR.

In this chapter, a protocol called on-chip polymerase chain reaction (PCR) is presented for the deoxyribonucleic acid (DNA) microarray-based detection of bacterial target sequences. On-chip PCR combines, in a single step, the conventional amplification of a target with a simultaneous, nested PCR round intended for target detection. While freely diffusible primers are deployed for amplification, the nested PCR is initiated by oligonucleotide primers bound to a solid phase. Thus, on-chip PCR allows the single-step amplification and characterization of a DNA sample as a result of separation in liquid and solid-phase reactions. In contrast to conventional PCR, the reaction is performed directly on the flat surface of a glass slide that holds an array of covalently attached nested primers. The bacterial target DNA is amplified and probed using primers identifying either species-specific sequence regions of ribosomal DNA or unique bacterial target genes, such as virulence or resistance factors. The microarray is produced using standard spotting equipment with an array layout containing a high number of replicates. Fluorescence scanning of on-chip PCR slides allows the rapid detection of the target of interest. The protocol described herein will show how on-chip PCR can be used to detect and precisely identify DNA of bacterial origin.

Animals↗

Imaging neuronal seal resistance on silicon chip using fluorescent voltage-sensitive dye.

The electrical sheet resistance between living cells grown on planar electronic contacts of semiconductors or metals is a crucial parameter for bioelectronic devices. It determines the strength of electrical signal transduction from cells to chips and from chips to cells. We measured the sheet resistance by applying AC voltage to oxidized silicon chips and by imaging the voltage change across the attached cell membrane with a fluorescent voltage-sensitive dye. The phase map of voltage change was fitted with a planar core-coat conductor model using the sheet resistance as a free parameter. For nerve cells from rat brain on polylysine as well as for HEK293 cells and MDCK cells on fibronectin we find a similar sheet resistance of 10 MOmega. Taking into account the independently measured distance of 50 nm between chip and membrane for these cells, we obtain a specific resistance of 50 Omegacm that is indistinguishable from bulk electrolyte. On the other hand, the sheet resistance for erythrocytes on polylysine is far higher, at approximately 1.5 GOmega. Considering the distance of 10 nm, the specific resistance in the narrow cleft is enhanced to 1500 Omegacm. We find this novel optical method to be a convenient tool to optimize the interface between cells and chips for bioelectronic devices.

Cell Culture Techniques↗