Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cardiotocography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

[Computer-assisted analysis of intrapartum cardiotocodynagraphs].

OBJECTIVE: To develop a numerical index by quantifying characteristic cardiotocography parameters in order to determine the intrauterine state of the fetus sub partu with sufficient accuracy to improve the diagnostic potential of cardiotocography. This score is then computerized for offline and online analysis. METHODS: The last 120 minutes of 406 directly recorded intrapartal cardiotocograms (CTG) were evaluated with a magnifying glass on the basis of conventional criteria. The mean basal frequency, the amplitude and the oscillation frequency of each individual baseline minute, the decelerations with depth, duration and type classification as well as the accelerations were determined. The Apgar score and the measurements of blood gases in the umbilical arterial and venous blood served as outcome parameters. The actual pH in the umbilical artery (UA) was the key variable. The newly developed CTG score was converted into a complex programming language after meticulous statistical testing and prepared for offline and online use. RESULTS: A score which is based on the CTG characteristics basal frequency level, baseline fluctuation and total decelerations area was developed on the basis of about 40 000 baseline minutes and more than 8 000 analysed decelerations from 406 fetuses which were all vaginal deliveries with a rate of acidosis (pH,UA < 7.100) of 9.8 % (deliberate selection). This score correlates highly significantly (r = -0.5752) with the actual umbilical arterial pH (p < 0.001). The correlation with the Apgar score (1 min) is r = -0.398, p < 0.001. The positive likelihood ratio (score 9) is 11.0 (95 % confidence interval 7.4-16.5) indicating that the test is very reliable. The score could be prepared for offline analysis of electronically registered CTGs with the assistance of a mathematician, so that the obstetrician's "eye work" can be dispensed with entirely. This program written in "C" also enables online evaluation of fetal heart rate patterns over time and a representation of the output parameters with acoustic and optical warning display options appropriate for the delivery room. CONCLUSIONS: Quantitative registration of fetal heart rate phenomena during delivery can be accomplished successfully by means of a score. The score correlates highly significantly with the actual pH value (UA) and the Apgar score (1 min). It is suitable both for offline and online analysis of intrapartal CTGs, and offers the prospect of quantitative fetal online monitoring.

Apgar Score↗

[Influence of antenatal acupuncture on cardiotocographic parameters and maternal circulation - a prospective study].

BACKGROUND: Acupuncture as a non-evidence-based therapy modality is widely used in obstetrics prior to and during delivery. Thus far, only few studies investigated the impact of acupuncture on obstetric surveillance parameters like cardiotocography. The aim of this study was to control the effect of clearly-defined acupuncture on CTG parameters. PATIENTS AND METHODS: 61 low-risk singleton pregnancies between 30 + 0 and 39 + 6 weeks of gestation were prospectively treated with acupuncture at GV 20 and ST 36 bilaterally for the purpose of maternal relaxation by the same investigator under CTG control. Before (Phase 1), during (Phase 2) and after (Phase 3) treatment the cardiotocogram was recorded. Controlled parameters of outcome were the Fisher score, uterine activity (Phase 1, 2, 3) and maternal blood pressure and pulse before (Phase 1) and after (Phase 2) administration of acupuncture. In a matched control group, 60 pregnant women were monitored by an identical scheme without application of acupuncture and the same outcome parameters were recorded. RESULTS: : The CTG analysis revealed a statistically significant increase of the Fisher score as well as uterine activity which tended to trace back to pretherapeutic initial values. The systolic maternal blood pressure was found to show a statistically significant decrease while diastolic blood pressure and pulse frequency remained unchanged. In the control group, the comparison of phase 1 vs. phase 2 showed a statistically significant increase of the Fischer score and uterine activity. During phase 3 the Fischer score further increased in contrast to a statistically significant slight reduction of uterine activity. Maternal systolic blood pressure measured at the end of phase 2 was found to be statistically reduced while diastolic blood pressure and pulse remained unchanged. The extent of the systolic blood pressure reduction was markedly higher in the acupuncture group as compared to the control group. CONCLUSIONS: Antenatal acupuncture as a reflex therapy for the purpose of maternal relaxation seems to exert an influence on short-term alterations of the fetal activity (transient increase in terms of Fischer score) with reversibly increased uterine activity as detected by cardiotocography. Also, a slight reduction of the maternal blood pressure seems to be effected. The phenomena recorded in the control group (relaxation without supportive acupuncture treatment) revealed to be partially concordant (reversibly increased uterine activity, mild maternal reduction of systolic blood pressure) and partially discordant (persisting increase of Fischer score) as compared with the acupuncture group. Acupuncture seems not only to have a psychological, but also a short-term somatic effect with direct influence on maternal and fetal circulation parameters. Other established surveillance parameters and different points of acupuncture should be studied to further elucidate the underlying interaction as well as the duration of this effect.

Acupuncture↗

Evaluation of non-reassuring fetal heart rate patterns with fetal pulse oximetry combined with vibratory acoustic stimulation.

OBJECTIVE: To determine the value of fetal pulse oximetry and vibratory acoustic stimulation in the presence of non-reassuring fetal heart rate patterns during labor. DESIGN: Prospective study in women monitored by cardiotocography and fetal pulse oximetry during labor. MATERIALS AND METHODS: During a period of 18 months, 907 consecutive parturients in labor were monitored by cardiotocography. Out of these women, 63 were selected on the basis of a non-reassuring fetal heart rate tracing during the first stage of labor. In these cases, fetal pulse oximetry was applied. Vibratory acoustic stimulation was applied in fetuses without spontaneous reactivity in order to evaluate the fetal status. RESULTS: Our cases were classified into three groups, according to the lower fetal oxygen saturation levels, from the time of oximetry application until delivery. Group A consisted of 29 cases where fetal oxygen saturation levels were > or = 41%, group B (20 cases) with fetal oxygen saturation of 31-40% and group C (14 cases) with levels of < 30%. Spontaneous reactivity was observed in 15 fetuses of group A and seven of group B, while no case of reactivity was noted in group C. Vibratory acoustic-induced reactivity was associated with low fetal oxygen saturation levels. The mean umbilical artery pH levels were 7.29 +/- 0.051 in group A, 7.21 +/- 0.057 in group B and 7.04 +/- 0.05 in group C. CONCLUSION: Fetal pulse oximetry should be indicated not only in fetuses without any reactivity but also in those with induced reactivity, after the application of vibratory acoustic stimulation.

Acoustic Stimulation↗

Impact of oxytocin discontinuation on fetal heart rate and uterine contractility: A pre-specified ancillary analysis embedded within a randomized trial.

INTRODUCTION: Oxytocin is widely used to augment uterine contractions during labor. However, its use has been associated with fetal heart rate (FHR) abnormalities and neonatal morbidity, which may be reduced by discontinuing oxytocin during labor. We aimed to assess the impact of oxytocin discontinuation at the onset of the active phase of labor on FHR patterns and uterine contractility. MATERIAL AND METHODS: This study is a pre-specified ancillary analysis of the STOPOXY trial, a multicenter, randomized, open-label, controlled superiority trial conducted in 21 French maternity units between January 2020 and January 2022, which aimed to assess the impact of oxytocin discontinuation during active labor on neonatal morbidity. Participants who received oxytocin before 4&#x2009;cm dilation were randomly assigned (1:1) to either oxytocin discontinuation or oxytocin continuation. For the present analysis, we included women from the per-protocol discontinuation group of the parent trial. Inclusion was restricted to the six centers with electronic cardiotocography storage where valid cardiotocography recordings were available for at least 1&#x2009;h before and 1&#x2009;h after oxytocin discontinuation. Using a paired before-and-after design, FHR parameters (classified according to FIGO criteria) and uterine activity were compared during the 60&#x2009;min preceding versus the 60&#x2009;min following oxytocin discontinuation by independent obstetricians blinded to neonatal outcomes. Changes in FHR pattern were categorized as no change, improvement, or deterioration. RESULTS: 284 women fulfilled the eligibility criteria. Following oxytocin discontinuation, mean FHR increased (135 vs. 137.5&#x2009;bpm; p&#x2009;<&#x2009;0.002) and FHR variability significantly changed (p&#x2009;=&#x2009;0.010), with a lower rate of reduced variability (3.9% vs. 2.5%) and a higher rate of normal variability (48.2% vs. 53.3%). The proportion of tracings with decelerations significantly decreased (64.1% vs. 48.6%; p&#x2009;<&#x2009;0.001). Uterine activity decreased, with fewer uterine contractions (4.0 vs. 3.5 contractions per 10&#x2009;min; p&#x2009;<&#x2009;0.001). CONCLUSIONS: Among women receiving oxytocin during early labor, discontinuation at the onset of the active phase was associated with improved FHR patterns and reduced uterine activity, suggesting a lower fetal stress and tachysystole. Further studies are needed to assess whether these changes affect labor management or maternal experience.

Humans↗

A randomised controlled trial of simple compared with complex antenatal fetal monitoring after 42 weeks of gestation.

OBJECTIVE: To compare the impact on perinatal outcome of two different protocols for antenatal fetal monitoring after 42 weeks gestation. DESIGN: A prospective randomised controlled trial. SETTING: Liverpool Maternity Hospital. SUBJECTS: One hundred and forty-five women with singleton, uncomplicated pregnancies after 42 weeks of gestation. INTERVENTIONS: Random allocation to fetal monitoring by either: 1. a modified biophysical profile comprising of computerised cardiotocography, amniotic fluid index, and assessment of fetal breathing, tone and gross body movements; or 2. standard cardiotocography and maximum pool depth. OUTCOME MEASURES: Cord pH at delivery, number of abnormal monitoring tests, intrapartum management, mode of delivery and neonatal outcome. RESULTS: There were significantly more abnormal antenatal monitoring results in the modified biophysical profile group (47.2% vs 20.5%; odds ratio = 3.5, 99% CI = 1.3-9.1). There were no differences in cord blood gases, neonatal outcome, or in outcomes related to labour and delivery between the two groups, but a trend towards more obstetric interventions in the modified biophysical profile group was noted. Amniotic fluid volume after 42 weeks was more likely to be labelled as abnormal with amniotic fluid index than with maximum pool depth (44.4% vs 15.1%; odds ratio = 4.5, 99% CI = 1.6-12.8). CONCLUSIONS: The results suggest that after 42 weeks fetal monitoring with the modified biophysical profile does not improve pregnancy outcome as measured by umbilical cord pH, but is more likely to yield an abnormal result. The higher incidence of abnormal monitoring results in the modified biophysical profile group was likely to be caused by different methods of amniotic fluid assessment in the modified biophysical profile group (amniotic fluid index) and simple monitoring group (maximum pool depth). The use of amniotic fluid index as a test of fetal wellbeing in prolonged pregnancy may lead to more obstetric interventions with, as yet, unclear impact on the perinatal outcome.

Adult↗

A randomised comparison between amniotic fluid index and maximum pool depth in the monitoring of post-term pregnancy.

OBJECTIVE: To compare the impact of two different ultrasound methods for assessing amniotic fluid volume on the incidence of obstetric interventions in post-term pregnancies. DESIGN: A prospective randomised controlled trial. SETTING: Liverpool Women's Hospital. PARTICIPANTS: Five hundred women with singleton, uncomplicated pregnancies with gestational age > or = 290 days. INTERVENTIONS: Random allocation to fetal monitoring by either: 1. amniotic fluid index and computerised cardiotocography, or 2. maximum pool depth and computerised cardiotocography. MAIN OUTCOME MEASURES: Primary: caesarean section. Secondary: the number of abnormal monitoring tests, induction of labour, intrapartum management and neonatal outcome. RESULTS: The number of abnormal amniotic fluid indices was significantly higher than the number of abnormal maximum pool depths (10% vs 2.4%; OR 4.51, 95% CI 1.82-11.21; P = 0.0008) which resulted in more inductions for abnormal post-term monitoring in the amniotic fluid index group (14.8% vs 8.4%; OR 1.89; 95% CI 1.07-3.33; P = 0.0362) and more intrapartum electronic fetal monitoring (94.4% vs 88.4%; OR 2.21; 95% CI 1.13-4.29; P = 0.0255). There were no other statistically significant differences in outcomes related to labour and delivery, but there was a trend towards more caesarean sections in the amniotic fluid index group (18.8% vs 13.2%), in particular caesarean sections for fetal distress (8% vs 4%). There were no perinatal deaths and no statistically significant differences in perinatal outcome between the two groups. CONCLUSIONS: Published reference ranges for amniotic fluid index overestimate the number of abnormal results in post-term pregnancies. Their use, when compared with maximum pool depth, is likely to increase the number of obstetric interventions with, as yet, an uncertain impact on perinatal mortality and morbidity. It is possible that antepartum fetal assessment in pregnancies where the risk of adverse perinatal outcome is very low may cause, rather than prevent morbidity.

Adult↗

The development and evaluation of a computer-assisted teaching programme for intrapartum fetal monitoring.

OBJECTIVE: The development and evaluation of a computer-assisted teaching programme of cardiotocography and acid-base balance. DESIGN: Randomised controlled trial. PARTICIPANTS: One hundred and seventeen midwifery and obstetric staff at Derriford Hospital, Plymouth. METHODS: The obstetricians and midwives were randomly allocated to use the teaching programme, either early or late. The late group (control) used the teaching programme three months after the early group. To assess the effect of the teaching programme, participants were tested on four occasions over eight months by a multiple choice questionnaire. Two questionnaires on ease of use were also completed. MAIN OUTCOME MEASURES: Multiple choice questionnaire scores and opinion questionnaire results. RESULTS: The mean score in the early group improved from 50-8% (test 1, pre-teaching programme) to 70.2% (test 2, post-teaching programme). The mean score in the control group was 50.3% (test 1) and 54.8% (test 2). Knowledge was retained up to seven months. CONCLUSIONS: The teaching programme was effective in improving knowledge of acid-base balance and cardiotocography and can be used by all staff whilst on duty on the labour ward.

Acid-Base Equilibrium↗

Antepartum cardiotocographic surveillance of patients with diminished fetal movements.

Over a 9-year period, 2,601 women had antenatal cardiotocography (CTG) performed after reporting diminished fetal movements. This series represented 5.6% of the total hospital population and 16.1% of those having antenatal CTG performed. The perinatal mortality rate (0.8%) and major fetal malformation rate (2.2%) were lower than in the hospital population (1.1% and 4.5% respectively). The incidence of abnormal CTG tracings was lower in the 1,390 women with diminished movements alone (6.4%) compared with the 1,211 who had additional antenatal complications (10.2%, p less than 0.001). Likewise the incidences of critical fetal reserve CTG and perinatal mortality were significantly lower in the group without additional complications (0.3% and 0.5%) compared with those with additional complications (1.7% and 1.2% respectively). The 24 patients with critical fetal reserve CTG were promptly delivered (19 by Caesarean section) with favourable results in 19, cerebral palsy in 1, and 4 perinatal deaths - 2 of these deaths resulted from intrauterine hypoxia (table 3, Cases 12 and 15). There were 17 perinatal deaths in cases where the CTG was satisfactory (13) or showed reduced reserve (4); 9 of these were unavoidable as a result of major malformations or other lethal conditions. The other 8 deaths resulted from hypoxia, including 4 in pregnancies at or beyond 37 weeks' gestation (table 3, Cases 6-9), illustrating that delivery is warranted in women with diminished fetal movements when conditions are favourable even when the CTG is satisfactory. Cardiotocography is useful in the management of patients with diminished fetal movements.

Cardiotocography↗

Should assessment of amniotic fluid volume form an integral part of antenatal fetal surveillance of high risk pregnancy?

This study was conducted to evaluate the role of the Amniotic Fluid Index (AFI), used along with nonstress cardiotocography (NST) and fetal acoustic stimulation test (FAST), when required, in prediction of adverse pregnancy outcome. Over a 3-year period 565 pregnant women had antepartum fetal surveillance due to various high risk pregnancy factors and delivered within 7 days of the test. Antepartum fetal surveillance included nonstress cardiotocography together with estimation of AFI. Need for induction of labour, presence of meconium at rupture of membranes, Caesarean section for fetal distress, Apgar score at 5 minutes, need for neonatal endotracheal intubation, admission to neonatal special care unit and perinatal death were the main outcome measures. Nonreactive nonstress tests and Caesarean sections for fetal distress were more common and neonatal outcome was significantly poorer in patients with AFI < 5 cm than in those with higher AFI values. Of the 4 perinatal deaths in the group with AFI < 5 cm, 3 had a reactive NST within 7 days of fetal death. It is concluded that pregnancy outcome is often poor in the presence of very low AFI and in these cases a reactive NST loses its usual reassuring value. It is suggested that AFI estimation should be included as an integral part of antepartum fetal surveillance of high risk pregnancies.

Acoustic Stimulation↗

Original report. Fetal cardiographic monitoring during 1.5-T MR imaging.

OBJECTIVE: The aim of this report was to determine the feasibility of fetal cardiotocography during MR imaging and the safety of 1.5-T MR imaging on the basis of fetal heart activity and fetal movements. CONCLUSION: Fetal cardiotocography is feasible during MR imaging using modified standard equipment. The use of 1.5-T MR imaging appears to be safe and to have no negative short-term effects on the heart rate or movement incidence of healthy third-trimester fetuses under our experimental conditions.

Adolescent↗

Doppler velocimetry and non stress test in severe fetal growth restriction.

OBJECTIVE: The aim of our study was to evaluate the efficacy of Doppler velocimetry and cardiotocography in surveillance of the fetus affected by severe fetal growth retardation (FGR) and hence their capacity in predicting adverse perinatal outcome. This could therefore permit the timing of delivery thus reducing perinatal morbidity and mortality. METHODS: 53 women with high risk pregnancies, all suffering from various pathologies such as gestational hypertension, preeclampsia, HELLP syndrome, Antithrombin III deficit, and in whom FGR (fetal abdominal circumference < 2.5th percentile for gestational age) diagnosed between the 24th and 35th week of gestational age, were retrospectively enrolled in the study. Doppler velocimetry was carried out on the main vascular districts - both arterial [umbilical artery (UA), middle cerebral artery (MCA), aorta (Ao) and uterine artery] and venous [umbilical vein (UV), ductus venosus (DV), inferior vena cava (IVC)]. Also evaluated was the amniotic fluid index (AFI). Daily non stress tests (NST) were conducted at least thrice a day for an overall period of not shorter than 60 min. Also considered were the methods of delivery and the perinatal outcome, e.g. gestational age at birth, perinatal mortality, incidence resuscitation, etc. RESULTS: The 53 patients studied were subdivided into three groups on the basis of the initial velocimetric exam of the umbilical and uterine arteries. Group A was comprised of those with altered waveforms of the UA, Group B those with altered waveforms on the uterine artery while Group C contained those with altered waveforms both of the UA and uterine artery. The period of study for group C was on average six days (p < 0.05) while for groups A and B they were on average 10 and 22 days, respectively. Group C also presented higher incidences of altered waveforms in the venous compartment, i.e. absent or reversed end diastole (ARDEF) was observed in 89% of the cases versus 0% and 7.6% observed in Group A and B, respectively. Altered waveforms in the DV and pulsations in the UV were both observed in Group C while the same was not observed in either group A or B. The NST did not show any substantial difference between the groups - only as the appearance of decelerations present in over half the cases in all groups at the end of the study. Group C also presented higher incidences in adverse perinatal outcome as compared to groups A and B such as as low birth weight (868 g vs 1,324 g & 1,397 g, p < 0.001), neonatal resuscitation (52.6% vs 0% & 7.6% p = 0.001), longer periods of admission to neonatal intensive care unit (67 days vs 32 & 33 p < 0.001) and perinatal mortality (36% vs 0 & 0, p < 0.05). The velocimetric indices which appear to better predict perinatal mortality are those related to the venous compartment giving a diagnostic accuracy of 92.8% (KI > 0.75) in case of pulsations in the UV, 86.6% (KI > 0.75) with alterations on the DV, and of 78.5% (KI > 0.40) for those on the IVC. Cardiotocography revealed to be less capable in predicting perinatal mortality giving a diagnostic accuracy of 66.6% (KI > 0.40) with a non reactive, non variable NST. CONCLUSION: The data presented show that velocimetric modifications in the fetal venous compartment constitute a relevant prognostic sign in the prediction of perinatal mortality and neonatal resuscitation. The further the vessels compromised are from the heart, the higher is the relative risk for perinatal mortality, equal to 5.0 (95% C.I. = 0.61-40.9) with alterations on the IVC, of 8.2 (95% CI = 1.04-61.5) when they involve the DV, and of 18.0 (95% = 2.44-133) when pulsations are obtained on the UV.

Cardiotocography↗

[A technique of continuous medical image digital restoration].

OBJECTIVE: To set up a new technique of continuous medical image digital restoration for electronic record management. METHODS: According to Freeman's chain-code principle, 92 fetal cardiotocography were scanned, thinned, trailed, and chain-coded by computer system. RESULTS: 92 paper-recorded cardiotocography, were transformed to digital data and saved by computer, 23 parameters were produced, which could be used in further study. CONCLUSION: Capacity of a restoring instrument can be greatly saved since the using of digitalized restoration, so that more useful data can be stored in doctor's workstation. Digitalized data can be much easier used in electronic record management, for convenient studies research.

Cardiotocography↗

[Usefulness of the examination of fetal blood oxygen saturation (FSpO2) and fetal heart rate (FHR) as a prognostic factor of the newborn outcome].

OBJECTIVES: Cardiotocography has become the standard for fetal monitoring in labor. False-positive findings during electronic fetal heart rate monitoring may were not associated with neonatal acidemia. Because of the poor specificity of fetal heart rate monitoring in predicting fetal distress, new methods are being investigated as a way to improve the accuracy of assessing the infant's condition during labor. DESIGN: The aim of this study was to determinate the efficiency of fetal blood oxygen saturation (FSpO2) and computer analysis of the fetal heart rate (Co-CTG) in the late 1-st stage of labor as a prognostic factor of newborn acidemia. MATERIALS AND METHODS: Total 62 subjects were studied. During labors and deliveries fetal oxygen saturation was continuously recorded, with use of Nellecor N-400 fetal pulse oximeter and continous CTG were performed by Hewlett Packard 50A. Transdermal fetal oxygen saturation measurements and CTG results obtained during the labors was analyzed using MONAKO system (ITAM Zabrze). The results were compared with the values of pH and base deficit in the umbilical artery measured just after delivery. RESULTS: The sensitivity, specificity, negative, positive predictive values and Youden factor based on FHR and FSpO2, for prognosis of neonatal acidosis were: 65%, 80%, 16%, 97.5% 60% and 0.135 respectively FHR; and 100%, 60%, 100%, 96.8% and 0.968 respectively FSpO2. CONCLUSIONS: 1. The examination of fetal blood oxygen saturation in the labor is a useful prognostic factor of the newborn outcome. 2. The best predictive value for intrapartum fetal asphyxia with metabolic acidosis was found when fetal pulse oximetry is added to cardiotocography.

Acidosis, Respiratory↗

[Fetal monitoring for anesthesiologists].

Several monitoring methods for the fetus are presented, the knowledge of which is appropriate for anesthesiologists active in the field of obstetrics. A distinction is made between external, indirect methods for monitoring when the amniotic sac is intact and internal, direct methods employed when the sac has ruptured. Particular emphasis is placed on cardiotocography (CTG), which is an obligatory method of routine monitoring during the late period of cervical dilatation and expulsion. It registers the reaction of fetal heart rate to parturition and labor, and represents a good indirect measure of both uteroplacental blood flow and fetal cardiac reserve. Criteria of evaluation for cardiotocograms are presented on the basis of guidelines elaborated by the Standard Committee on Cardiotocography (Chairman: Prof. Dr. H. Rüttgers). These enable the status of the fetus to be evaluated with differentiation. An inevitable sign of fetal well-being is a normal baseline with a rate between 120 and 160 beats/min, normal microfluctuation, and oscillations between 5 and 25/min with absent variable or late decelerations. Warning signs are restricted microfluctuation, elevated baseline, variable decelerations, and clinical passage of meconium. Suspicious signs are a baseline between 100-119 and 161-170 beats/min, respectively, decreased oscillation amplitude, and protracted decelerations over as much as 2 min.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Echocardiographic evaluation of fetal arrhythmias.

When during routine prenatal care, the auscultation++ of the fetal heart beat reveals an abnormal rate or rhythm, two things are needed: 1) the accurate diagnosis of the arrhythmia, and 2) the hemodynamic impact of the rhythm disturbance on the fetus. In Poland, external cardiotocography is the most widely Supported in part by the American Heart Association, Delaware Affiliate, Grant = 41161 available diagnostic system used by obstetricians, but it records only the mean heart rate or the instantaneous heart rate. Cardiotocography is therefore useful only in identifying tachycardia or bradycardia. The most frequent tape of fetal arrhythmia is an irregular rhythm, especially premature contractions (1, 15, 18). We believe that any disturbance in fetal cardiac condition should be evaluated more fully by fetal echocardiography.

Arrhythmias, Cardiac↗

Fetal grasping of the umbilical cord and perinatal outcome.

This study assessed perinatal outcome in pregnancies with accidentally diagnosed fetal grasping of the umbilical cord (FGUC) on ultrasonography (US) in late gestation as a possible cause of fetal hypoxia due to mechanical occlusion of umbilical circulation. In this retrospective clinical study, routine antenatal US examination revealed FGUC from 32 to 41 weeks of gestation in seven normal single pregnancies. Upon FGUC findings, fetal condition was followed up every second day by repeat US findings of FGUC, and then by Doppler parameters of fetoplacental circulation measurement of resistance index in umbilical artery (URI) and middle cerebral artery (CRI), and cardiotocography (CTG), and perinatal outcome (peripartal cardiotocography, 5-min Apgar score, umbilical arterial blood pH, occurrence of meconium amniotic fluid, need of additional treatment at neonatal intensive care unit (NICU), and mode of pregnancy termination (cesarean section, forceps or vacuum extraction-VE for hypoxia). After delivery, neonatal neurosonography and neonatal complications related to pregnancy or birth were evaluated. All URI values were increased, resulting from persistent FGUC and elevated umbilical arterial RI. CRI showed great oscillations in the values for gestational age and decreased CRI. In two cases, cerebral/umbilical ratio was less than 1, indicating initial vasocentralization as a fetal compensatory mechanism for hypoxia. In these cases, a pathological peripartal CTG and pH 7.23, indicative of preacidosis, were verified. All children were discharged from NICU as healthy, free from neurological lesions, with the exception of the latter, who had dystonia syndrome and mild motor deficit as a sign of peripartal hypoxia. Although it probably belongs to normal reflexes, intermittent FGUC should be US controlled. Persistent FGUC should be considered pathological for its possible hypoxic effect and umbilical circulation obstruction. These pregnant women should be hospitalized and closely monitored, as in part confirmed by the present study.

Adult↗

[Do we have to monitor foetal heart rate during general anesthesia?].

We present a case of an emergency Caesarean section due to misinterpretation of the cardiotocography (CTG) trace during general anaesthesia for treatment of dental abscess. Following failure of the dental abscess treatment under local anaesthesia, a 29-year-old female in the 36th week of a twin pregnancy was to undergo general anaesthesia. Foetal well-being was monitored with ultrasonographic evaluations of foetal heart rate. During surgery, senior obstetrician recorded a lack of beat-to-beat variability of the cardiotocography trace. The CTG pattern was interpreted as foetal distress and an emergency Caesarean section was performed under general anaesthesia. That was probably due to general anaesthesia. Then, two infants were extracted without neonatal distress necessitating intubation. This case report underlines the risk to misread an intraoperative CTG monitoring and if the CTG monitoring is normal before anaesthesia, reduced foetal beat-to-beat variability with a normal baseline heart rate during general anaesthesia is probably normal.

Adult↗