Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Increased protein yields from Escherichia coli using pressure-cycling technology.

Sample preparation is critical to the success of two-dimensional gel electrophoresis and other analytical methods. Pressure-cycling technology (PCT) uses alternating cycles of high and low pressure to induce cell lysis. Cell suspensions were placed in PULSE Tubes and subjected to alternating cycles of high and low pressure in a Barocycler instrument. each cycle consisted of 20 sec at 35,000 psi followed by 20 sec at ambient pressure. For the bacterium Escherichia coli, PCT extracted 14.2% more total protein than was extracted using a standard bead mill. Image analysis of two-dimensional gels revealed 801 protein spots in the PCT lysate, compared to 760 protein spots in the bead mill lysate.

Biotechnology↗

[Determination of major volatile components in suhexiang wan (storax pill) using analytical supercritical fluid extraction (SFE)].

A new method based on the off-line coupling of analytical SFE and GC has been developed for qualitative and quantitative analysis of major volatile components in Suhexiang Wan, a Chinese patent medicine. The factors affecting extraction efficiency were examined to seek the optimal operating parameters. Quantitative recovery (90%) was achieved with 20 ml CO2 in ca 1 h using a self-designed analytical SFE system. Compared with the conventional methods, the SFE as an alternative technique for sample preparation will be most useful in the quality control of Chinese patent medicine.

Benzoates↗

Pesticide multiresidue analysis of 303 compounds using supercritical fluid extraction.

Compared to generally used solvent extraction methods, supercritical fluid extraction (SFE) with carbon dioxide has the advantages of automation and simple operation in preparing samples for pesticide residue analysis. This report is the outcome of our evaluation of the practicality of SFE for the preparation of samples for pesticide residue analysis. We studied the recovery of 303 compounds with several crops by a simultaneous analytical method of SFE, cartridge column purification, followed by GC/MS determination. We achieved 70 to 120% recovery for more than 80% of the examined compounds.

Journal Article↗

Determination of lead in bone tissues by axially viewed inductively coupled plasma multichannel-based emission spectrometry.

A new procedure for determining low levels of lead in bone tissues has been developed. After wet acid digestion in a pressurized microwave-heated system, the solution was analyzed by inductively coupled plasma multichannel-based emission spectrometry. Internal standardization using the Co 228.615 nm reference line was chosen as the optimal method to compensate for the matrix effects from the presence of calcium and nitric acid at high concentration levels. The detection limit of the procedure was 0.11 microg Pb g(-1) dry mass. Instrumental precision at the analytical concentration of approximately 10 microg l(-1) ranged from 6.1 to 9.4%. Precision of the sample preparation step was 5.4%. The concentration of lead in SRM 1486 (1.32+/-0.04 microg g(-1)) found using the new procedure was in excellent agreement with the certified level (1.335+/-0.014 microg g(-1)). Finally, the method was applied to determine the lead in various fish bone tissues, and the analytical results were found to be in good agreement with those obtained through differential pulse anodic stripping voltammetry. The method is therefore suitable for the reliable determination of lead at concentration levels of below 1 microg g(-1) in bone samples. Moreover, the multi-element capability of the technique allows us to simultaneously determine other major or trace elements in order to investigate inter-element correlation and to compute enrichment factors, making the proposed procedure particularly useful for investigating lead occurrence and pathways in fish bone tissues in order to find suitable biomarkers for the Antarctic marine environment.

Animals↗

Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

Body Fluids↗

High-sensitivity capillary electrophoresis determination of inorganic anions in serum and urine using on-line preconcentration by transient isotachophoresis.

Concentrations of inorganic anions, both as individual species and biotransformation products, in physiological fluids are of strong concern in clinical studies. To date, analytical methodologies have either required different analytical procedures to determine these analytes in plasma and urine, or extensive sample preparation, or unconventional and often expensive detection schemes, or both. A simple and sensitive capillary electrophoresis (CE) method with direct UV detection was developed for the simultaneous determination of iodide, bromide and nitrate in human plasma and urine, with a special focus on reliable quantification of the trace serum iodide. With the latter objective, the method incorporates a transient isotachophoresis (tITP) procedure enabling an efficient on-line preconcentration of iodide (limit of detection, 1.4 microg l(-1)) as well as other moderately mobile analytes that fall into the tITP range. The analyses of both types of biofluids were performed using an acidic electrolyte system composed of 0.25 mol l(-1) sodium chloride and 7.5 mmol l(-1) cetyltrimethylammonium chloride at pH 2.2 and 0.5 mol l(-1) 2-(N-morpholino)ethanesulfonate (pH 6.0) as terminating electrolyte. Relative standard deviations (R.S.D.) below 3.0% and 9.2% were obtained for within-day and between-day precision, respectively. Resolution and quantification of oxalic acid was also feasible under optimized tITP-CE conditions. Sample preparation required only ultrafiltration (serum) and dilution (urine). A number of plasma and urine samples were evaluated with this assay and the iodide, bromide and nitrate concentrations were in the expected clinical concentration ranges.

Anions↗

Validity of human nails as a biomarker of arsenic and selenium exposure: A review.

Human nail clippings have been used in recent epidemiological studies as a routine bioindicator of arsenic and selenium exposure. To ensure sound application of this biomarker, however, it is important to consider properties and scientific knowledge pertaining to validation of this particular tool. In this review, the use of human nails to measure exposure to arsenic and selenium is discussed in the context of the biomarker validation framework. Literature related to both analytical procedures and intrinsic characteristics of the biomarker is reviewed. Specifically, the followings are addressed: sample collection and preparation methods, establishment of the exposure-biomarker relationship, intraindividual variability and reproducibility of measurements, and biomarker-disease investigations. Drawing from a rapidly growing body of literature, current knowledge of these biomarker validation steps is assessed. Therefore, this review brings attention to the important issue of biomarker validation, laying the framework for future studies measuring elemental composition of nails.

Arsenic↗

[Occupational exposure to antineoplastic drugs in a hospital setting: biological and environmental monitoring].

OBJECTIVE: To estimate the occupational exposure of hospital personnel handling antineoplastics drugs using a highly sensitive and specific analitycal method in biological and environmental samples. DESIGN: To develop analitycal methods for the biological and environmental monitoring of more than one substance. SETTING: Five departments of the Policlinico Sant'Orsola-Malpighi (Bologna, Italy) involved in the preparation and administration of antineoplastic drugs. PARTICIPANTS: 50 nurses handling antineoplastics drugs. MAIN OUTCOME MEASURES: Evaluation of the occupational exposure of hospital personnel handling and administering anticancer drug cocktails. RESULTS: 19 of 50 subjects were positive to biological monitoring. Three were positive for MTX only, 11 for CP only and 5 subjects were positive for both. Urinary MTX levels ranged from 0.3 to 2.0 ppb, CP ranged fom 0.06 to 10.0 ppb. Wipe tests showed a higher contamination on the hoods working tray (where drugs are prepared), suggesting that the organization layout can affect the surface contamination level. Samples from each department resulted positive for at least one of three drugs. CONCLUSIONS: The analytical methods developed allow sensitive and specific determination of indicators of internal and external dose. Biological monitoring is of primary importance for assessing the real espoxure of hospital personnel during the preparation and administration of the drugs. Environmental monitoring stresses the importance to observe the Guidelines for standard operating procedures and the importance of protective disposables to reduce exposure and the associated health risk.

Antineoplastic Agents↗

A simple and rapid HPLC/UV method for the simultaneous quantification of theophylline and etofylline in human plasma.

A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%. A linear dynamic range of 100-10,000 ng/mL for both theophylline and etofylline was established. This HPLC method was validated with between-batch precision of 2.2-6.0 and 1.4-3.7% for theophylline and etofylline, respectively. The between-batch accuracy was 94.3-98.0 and 95.4-98.2%, respectively. Stability of theophylline and etofylline in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and rugged enough to be used in pharmacokinetic studies.

Chromatography, High Pressure Liquid↗

Determination of atrazine and its metabolites in mouse urine and plasma by LC-MS analysis.

Atrazine is a herbicide widely used on agricultural commodities. Existing analytical methods to analyze atrazine and its metabolites in biological matrices have various drawbacks. Thus, further development of such methods will be needed to correlate the growing number of toxicological effects associated with atrazine exposure with the concentrations of this compound and its metabolites in plasma, urine, and tissues. The purpose of this study was to develop a broad and sensitive LC-MS method for the analysis of atrazine and its metabolites in mouse urine and plasma. We were able to simultaneously measure atrazine and its major mammalian metabolites, which include didealkyl atrazine, desisopropyl atrazine, desethyl atrazine, atrazine-glutathione conjugate, and atrazine-mercapturate, using preparation procedures that used small sample volumes of plasma and urine (0.25 and 0.5 ml, respectively). Furthermore, derivatization of analytes prior to analysis was unnecessary. This method was used to analyze plasma and urine samples following single in vivo oral exposures of a limited number of mice to atrazine (doses, 5-250 mg/kg body weight) to demonstrate the utility of this LC-MS method. The data obtained from this study suggest that atrazine is rapidly metabolized in mice. Didealkyl atrazine was the most abundant metabolite detected in the urine and plasma samples (approximately 1000 microM in 24-h urine and approximately 100 microM in plasma following the highest dose of atrazine), with lesser quantities of mono N-dealkylated metabolites and thio conjugates of atrazine observed. We also used this methodology in a preliminary study of cytochrome P450-catalyzed metabolism of atrazine in vitro. The results obtained in this study suggest that this method will be a useful tool for the determination of atrazine and its metabolites in future pharmacokinetic studies and for the subsequent development and refinement of biologically based models of atrazine disposition.

Animals↗

[Automated analysis for determination of PCBs in fish].

An automated analytical method for determination of polychlorinated biphenyls (PCBs) in fish was developed using supercritical fluid extraction (SFE) in combination with an automated sample preparation instrument (Prep) and GC/MS. By incorporating basic alumina with the sample in the extraction process, and optimizing the amount of carbon dioxide used, fish lipid was selectively reduced. The extract was cleaned up on a Florisil cartridge with Prep. The method was evaluated using naturally contaminated tissues and by comparison of automated analytical method results with those obtained by the conventional method. Mean recovery of PCBs from 3 kinds of fish including hairtail, mackerel and yellowtail were 69.8%, 90.2% and 81.1%, respectively. This method is less laborious and requires far less organic solvent than the conventional method, but produced comparable results.

Animals↗

Melatonin receptor agents: synthesis, resolution by HPLC on polysaccharides chiral stationary phases, absolute configuration, and pharmacology of the enantiomers of (+/-)-N-[[2[(7-fluoro-1,2,3,4-tetrahydronaphthalen-1-yl)ethyl]acetamide.

In order to obtain milligram amounts of the enantiomers of tetrahydronaphthalenic derivative 5 to be tested for binding to the melatonin sites, preparative HPLC employed a mobile phase consisting of n-hexane-alcohol and a silica-based cellulose tris-methylbenzoate (Chiralcel OJ) using isocratic conditions and multiple repetitive injections. The preparative separation was optimized by adjusting the sample size from a scale-up of the analytical method. The enantiomeric elution order was reversed by the change from the carbamate type phase (Chiralcel OD-H) to the benzoate type phase (Chiralcel OJ) in analytical mode. The optical rotation and the circular dichroism spectra of the single enantiomers were determined after separation. The absolute stereochemistry of the two enantiomers of (+/-)-N-[2-(7-fluoro-1,2,3,4-tetrahydronaphthalen-1-yl)ethyl]acetamide 5 was established by X-ray crystallographic analysis. The purity obtained was sufficient for a first screen of their biochemical properties: the (-)-(S) enantiomer shows more affinity for melatonin receptors MT1, MT2 and is responsible of the selectivity towards MT2.

Cell Line↗

Chromatographic and electrophoretic methods for Lingzhi pharmacologically active components.

Lingzhi is the Chinese name given to the Ganoderma family of mushrooms, which was considered the most valuable medicine in ancient China and was believed to bring longevity, due to its mysterious power of healing the body and calming the mind. Today, Lingzhi is still widely revered as a valuable health supplement and herbal medicine worldwide, as studies (mostly conducted in China, Korea, Japan and the United States) into the medicinal and nutritional values of Lingzhi revealed that it does indeed contain certain bioactive ingredients (such as triterpenes and polysaccharides) that might be beneficial for the prevention and treatment of a variety of ailments, including important diseases such as hypertension, diabetes, hepatitis, cancers, and AIDS. As research into the biological activities of Lingzhi, as well as the quality assurance and quality control of Lingzhi products, require the isolation/purification of active ingredients from Lingzhi, followed by subsequent analytical and/or preparative separations, the present review summarizes the various chromatographic and electrophoretic methods (as well as sample pretreatment methods) typically employed to achieve such extraction/separation procedures.

Alkaloids↗

Cross-section analysis of organic light-emitting diodes.

The 'lift-out' technique using a focused ion beam microscope was applied to prepare cross-sectional specimens of organic light-emitting diodes for use in transmission electron microscopy. The focused ion beam equally thins the organic/inorganic hybrid devices despite the difference in material hardness of the compounds. This allowed to overcome preparation difficulties of conventional techniques such as ion thinning or ultra-microtomy. Two different samples were prepared and studied by both conventional transmission electron microscopy and analytical electron microscopy to display some of the investigation possibilities which become available with this sample preparation method.

Aluminum↗

Simplified detection of quaternary ammonium compounds by gas chromatography.

An analytical method for the measurement of quaternary ammonium compounds in biological fluids has been developed. Samples are prepared by forming the corresponding iodides, which are extracted and isolated. The residue is taken into n-hexane or into water and part of the solution obtained is injected onto the gas chromatograph where thermal degradation takes place. The methyl iodide released is measured by a 63Ni electron capture detector. This method is quite sensitive and detects with good reliability and reproducibility as little as 10(-14) mole quaternary ammonium compound.

Body Fluids↗

Methamphetamine impurity profiling using a 0.32 mm i.d. nonpolar capillary column.

Classification of seized methamphetamine by impurity profiling can provide very useful information in criminal investigations of drug traffic routes, sources of supply and relationships between seizures. The aim of this study is to improve and develop an analytical method for detecting impurities such as starting materials and by-products in illegally prepared methamphetamine.HCl samples. A 50mg sample of methamphetamine.HCl was dissolved in 1 ml of buffer solution (four parts 0.1M phosphate buffer pH 7.0 and one part 10% Na2CO3). Impurities were extracted with 0.5 ml of ethyl acetate containing four internal standards (ISs) (n-decane, n-pentadecane, n-nonadecane and n-hexacosane) and analyzed by gas chromatography (GC) using a flame ionization detector (FID) on a DB-5 capillary column (0.32 mmi.d. x 30 m, film thickness 1.0 microm). The use of a middle-bore column offered better separation of the impurity peaks. The correction of the retention times of impurity peaks with four ISs made peak identification very accurate for subsequent data processing. Twenty-four characteristic peaks were selected for comparison and similarity and/or dissimilarity between samples, and the data were evaluated by the Euclidean distance of the relative peak areas after logarithmic transformation. The results indicate that the present method would be useful for methamphetamine impurity profiling.

Chromatography, Gas↗

Metabolic acidosis: separation methods and biological relevance of organic acids and lactic acid enantiomers.

Metabolic acidosis can result from accumulation of organic acids in the blood due to anaerobic metabolism or intestinal bacterial fermentation of undigested substrate under certain conditions. These conditions include short-bowel syndrome, grain overfeeding of ruminants and, as recently reported, severe gastroenteritis. Measuring fermentation products such as short-chain fatty acids (SCFAs) and lactic acid in various biological samples is integral to the diagnosis of bacterial overgrowth. Stereospecific measurement of D- and L-lactic acid is necessary for confirmation of the origin and nature of metabolic acidosis. In this paper, methods for the separation of SCFAs and lactic acid are reviewed. Analysis of the organic acids involved in carbohydrate metabolism has been achieved by enzymatic methods, gas chromatography, high-performance liquid chromatography and capillary electrophoresis. Sample preparation techniques developed for these analytes are also discussed.

Acidosis, Lactic↗

Integrity profiling of high throughput screening hits using LC-MS and related techniques.

Integrity profiling of HTS hits is valuable for verification of the hit identity and purity. This provides early discovery researchers with more confident SAR theories. Methodology for integrity profiling of HTS hits must be high throughput, consume little material, and selectively provide structure-based data. Analytical techniques that can be utilized for integrity profiling methods are reviewed for their appropriateness in sample preparation, component separation, detection, purity quantitation, identity confirmation, and follow-up.

Chromatography, Liquid↗