Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “quantification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Quantification of Cryptosporidium parvum oocysts in mouse fecal specimens using immunomagnetic particles and two-color flow cytometry.

Although single-color flow cytometry has been shown to be more sensitive than fluorescence microscopy for the quantification of Cryptosporidium parvum oocysts, this method has not been optimized. Monoclonal antibody OW50, specific to the cell wall of oocysts, was conjugated to superparamagnetic particles, to fluorescein isothiocyanate, and to r-phycoerythrin. The oocysts were then double stained with the fluorochrome-labeled OW50 and were placed in tubes with known numbers of highly fluorescent polystyrene beads, allowing quantification of the oocysts without dependence on acquired sample volume by flow cytometry. Data from 2-color flow cytometry using logical gating of the oocysts and beads showed a linear relationship between dilutions of a purified oocyst suspension and the mean numbers of oocysts detected (r2 = 1.00). An average of 15 purified oocysts/ml were counted in a dilution with a theoretical concentration of 12 oocysts/ml. Known numbers of purified oocysts were seeded into normal mouse fecal specimens, captured by OW50-labeled immunomagnetic particles, eluted with 5% potassium dichromate at low pH, and double stained with fluorochrome-labeled OW50. By flow cytometry, the mean recovery was 43.1% (+/-8.3%), and as few as 133 oocysts were detected. The captured and eluted oocysts were infective in neonatal BALB/c mice. This 2-color flow cytometry method, used in conjunction with the capture and elution of oocysts by and from immunomagnetic particles, provides a powerful tool for not only the quantification and purification of C. parvum oocysts from different sources but also for the characterization of oocysts in vitro and in vivo.

Animals↗

Rapid competitive PCR using melting curve analysis for DNA quantification.

A rapid competitive PCR method was developed to quantify DNA on the LightCycler. It rests on the quantitative information contained in the melting curves obtained after amplification in the presence of SYBR Green I. Specific hybridization probes are not required. Heterologous internal standards sharing the same primer binding sites and having different melting temperatures to the natural PCR products were used as competitors. After a co-amplification of known amounts of the competitor with a DNA-containing sample, the target DNA can be quantified from the ratio of the melting peak areas of competitor and target products. The method was developed using 16S rDNA fragments from Streptococcus mutans and E. coli and tested against existing PCR-based DNA quantification procedures. While kinetic analysis of real-time PCR is well established for the quantification of pure nucleic acids, competitive PCR on the LightCycler based on an internal standardization was found to represent a rapid and sensitive alternative DNA quantification method for analysis of complex biological samples that may contain PCR inhibitors.

Binding, Competitive↗

Real-time DNA quantification of nuclear and mitochondrial DNA in forensic analysis.

The rapid development of molecular genetic analysis tools has made it possible to analyze most biological materialfound at the scene of a crime. Evidence materials containing DNA quantities too low to be analyzed using nuclear markers can be analyzed using the highly abundant mtDNA. However, there is a shortage of sensitive nDNA and mtDNA quantification assays. In this study, an assay for the quantification of very small amounts of DNA, based on the real-time Taq-Man assay, has been developed. This analysis will provide an estimate of the total number of nDNA copies and the total number of mtDNA molecules in a particular evidence material. The quantification is easy to perform, fast, and requires a minimum of the valuable DNA extracted from the evidence materiaL The results will aid in the evaluation of whether the specific sample is suitable for nDNA or mtDNA analysis. Furthermore, the optimal amount of DNA to be used in further analysis can be estimated ensuring that the analysis is successful and that the DNA is retained for future independent analysis. This assay has significant advantages over existing techniques because of its high sensitivity, accuracy, and the combined analysis of nDNA and mtDNA. Moreover, it has the potential to provide additional information about the presence of inhibitors in forensic samples. Subsequent mitochondrial and nuclear analysis of quantified samples illustrated the potential to predict the number of DNA copies required for a successful analysis in a certain typing assay.

Cell Nucleus↗

Fully automated quantification of regional cerebral blood flow with three-dimensional stereotaxic region of interest template: validation using magnetic resonance imaging--technical note.

The previously reported three-dimensional stereotaxic region of interest (ROI) template (3DSRT-t) for the analysis of anatomically standardized technetium-99m-L,L-ethyl cysteinate dimer (99mTc-ECD) single photon emission computed tomography (SPECT) images was modified for use in a fully automated regional cerebral blood flow (rCBF) quantification software, 3DSRT, incorporating an anatomical standardization engine transplanted from statistical parametric mapping 99 and ROIs for quantification based on 3DSRT-t. Three-dimensional T2-weighted magnetic resonance images of 10 patients with localized infarcted areas were compared with the ROI contour of 3DSRT, and the positions of the central sulcus in the primary sensorimotor area were also estimated. All positions of the 20 lesions were in strict accordance with the ROI delineation of 3DSRT. The central sulcus was identified on at least one side of 210 paired ROIs and in the middle of 192 (91.4%) of these 210 paired ROIs among the 273 paired ROIs of the primary sensorimotor area. The central sulcus was recognized in the middle of more than 71.4% of the ROIs in which the central sulcus was identifiable in the respective 28 slices of the primary sensorimotor area. Fully automated accurate ROI delineation on anatomically standardized images is possible with 3DSRT, which enables objective quantification of rCBF and vascular reserve in only a few minutes using 99mTc-ECD SPECT images obtained by the RVR method.

Aged↗

Blood flow in the carotid arteries: quantification by using phase-sensitive MR imaging.

The feasibility of MR phase-sensitive imaging for the quantification of blood flow in the carotid arteries was studied in two normal volunteers and six patients with carotid artery and/or cerebrovascular disease. The technique consists of sensitizing the phase of the MR signal to blood flow velocity gated to different times in the cardiac cycle. Flow velocities and volumes were measured by using transverse planes in the common, internal, and external carotid arteries, and flow curves were generated. Measurements made by using flow phantoms correlated well with calculated results. The MR measurements yielded values between 250 and 580 ml/min for the total flow through each of the common carotid arteries in the two normal volunteers. Markedly reduced flow (about 50% below normal) was detected in a patient whose arteriogram showed severe occlusion of the internal carotid artery. In a second patient, who had a large frontal intracranial arteriovenous malformation noted by arteriography, the MR-quantified flow was abnormally high (about 1 liter/min). In the remaining four patients, the findings on phase-sensitive quantification were consistent with those expected from clinical and other laboratory studies (including arteriography and sonography). These preliminary findings suggest that MR phase mapping may be a feasible tool for the noninvasive quantification of carotid blood flow.

Adult↗

Quantification of bacteria in middle ear effusions.

Quantification of bacteria in various effusion materials (serous, sticky glue, mucopurulent and purulent) collected from 128 middle ears (96 patients) was performed. After sampling, the effusion material was immediately flushed onto a glass slide, stained with acridine orange and examined under a fluorescence microscope. Quantification of bacteria was performed as described. 93% of the serous (n = 28) and 61% of the sticky glue (n = 46) effusion materials contained no bacteria whatsoever. The infectious sticky glue material (n = 18) contained 2.0 x 10(5) (median value), mucopurulent effusion material (n = 24) 2.6 x 10(7) (median value) and purulent effusion (n = 30) 10(9) (median value) bacteria per ml effusion material. Direct microscopic examination of middle ear effusion material, including quantification of the bacteria involved, provides much information about the pathophysiology of the middle ear inflammation.

Adult↗

Ultrasound characterization and quantification of carotid atherosclerosis lesions.

The development of ultrasonography in vascular applications has entailed research of ultrasound parameters leading to precise the diagnosis and quantification of carotid lesions in routine. The use of recent colour Doppler imaging techniques (velocity or power encoding) is recommended as they allow a better definition of the lesions and recesses. At present, features of plaque that could be related to increased incidence of stroke are: echogenicity, with a more frequent observation of anechoic or hypoechoic lesions in the case of clinical signs; texture, with frequent haemorrhage; surface contour, with a high rate of ulcerations which were accompanied by stroke; plaque motion, with a significant alteration in plaque motility in symptomatic patients; progression or regression in size, with a faster progression of anechoic and hypoechoic plaques; an increase in plaque volume is associated with a greater risk of stroke; a significant relationship between the presence of "ulcers" and embolic activity. The quantification of stenosis degree could be made using velocity criteria and/or morphological criteria. Velocity criteria could be obtained at the site of the stenosis (direct criteria) or downstream the carotid stenosis using Duplex systems. Morphological criteria could be obtained using B-mode imaging or colour Doppler but this quantification remains difficult in case of diffuse carotid stenoses or very severe stenoses.

Arteriosclerosis↗

Flow injection analysis of intracellular beta-galactosidase in Escherichia coli cultivations, using an on-line system including cell disruption, debris separation and immunochemical quantification.

A continuous integrated process for on-line quantification of intracellular components has been developed. By applying the concept of expanded micro-beds in a flow injection system it was possible to first perform on-line cell disintegration followed by an on-line binding assay for quantification of a reporter protein (beta-galactosidase) from the cell interior. The disintegration process involved the use of an expanded bed with immobilised lysozyme followed by ultrasonic treatment in a flow-through cell. The cell debris does not interfere in the binding assay as it is carried out in an expanded bed. The time for an assay cycle is at present approx. 35 min. This integrated system can be used for quantification of proteins down to at least 10(-7) mol/L.

Calibration↗

Quantification of carotid stenoses using 3D morphometer, CT angiography and conventional angiography.

BACKGROUND: The aim of this study is to compare the performances of 3D morphometer (M3D) regarding the quantification of extracranial carotid stenoses with selective 2D conventional angiography (reference technique) and spiral CT scan. METHODS: It is a prospective study, including 15 patients (mean age 75) presenting a symptomatic carotid lesion detected via duplex Doppler to be operated. Patients had to hold their breath for 20 seconds. Twenty-nine carotid bifurcations were studied by means of M3D and 2D conventional angiography (15 patients). Only 10 patients (19 bifurcations) underwent a CT scan. The measures were performed on a visual display unit by measuring the pixels as per the NASCET technique. Diameters (MIP technique) and surfaces (reformated axial slices) were measured. RESULTS: With MIP technique, a good correlation was found 20 times in 29 (69%) (overestimation: n=8/29) between M3D and angiography, but only in 9 of 19 cases (47%) between CT scan and angiography. Unlike with M3D, the slices re-oriented with CT scan gave better correlations: 15 times in 19 (79%). With the CT scan, the measures were impossible 8 times on MIP technique, and twice on reformated slices for calcified tight stenoses. Therefore, the quantification by means of spiral CT scan is easier by planimetry on slices. CONCLUSIONS: The reliability of these 3D explorations regarding quantification remains uncertain. The use of a morphometer, provided that technical adaptations are made, could replace selective sequences in multiple incidences that become accessible in the post-treatment period, with an acquisition field larger than the one of the CT scan.

Aged↗

Quantification of Alzheimer amyloid beta peptides ending at residues 40 and 42 by novel ELISA systems.

BACKGROUND: The amyloid beta (Abeta) peptide is a key molecule in the pathogenesis of Alzheimer's disease. Reliable methods to detect and quantify soluble forms of this peptide in human biological fluids and in model systems, such as cell cultures and transgenic animals, are of great importance for further understanding the disease mechanisms. In this study, the application of new and highly specific ELISA systems for quantification of Abeta40 and Abeta42 (Abeta peptides ending at residues 40 or 42, respectively) in human cerebrospinal fluid (CSF) are presented. MATERIALS AND METHODS: Monoclonal antibodies WO-2, G2-10 and G2-11 were thoroughly characterized by (SPOT) epitope mapping and immunoprecipitation/mass spectrometry. We determined whether aggregation affected the binding capacities of the antibodies to synthetic peptides and whether components of the CSF affected the ability of the antibodies to bind synthetic Abeta1-40 and Abeta1-42 peptides. The stability of Abeta40 and Abeta42 in CSF during different temperature conditions was also studied to optimize sample handling from lumbar puncture to Abeta assay. RESULTS: The detection range for the ELISAs were 20-250 pM. The intra-assay variations were 2% and 3%, and the inter-assay variations were 2% and 10% for Abeta40 and Abeta42, respectively. The antibodies specifically detected the expected peptides with equal affinity for soluble and fibrillar forms of the peptide. The presence of CSF obstructed the recognition of synthetic peptides by the antibodies and the immunoreactivity of endogenous CSF Abeta decreased with increasing storage time and temperature. CONCLUSIONS: This study describes highly sensitive ELISAs with thoroughly characterized antibodies for quantification of Abeta40 and Abeta42, an important tool for the understanding of the pathogenesis of Alzheimer's disease. Our results pinpoint some of the difficulties associated with Abeta quantification and emphasize the importance of using a well-documented assay.

Albumins↗

Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model.

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

Adult↗

Nonuniform transmission in brain SPECT using 201Tl, 153Gd, and 99mTc static line sources: anthropomorphic dosimetry studies and influence on brain quantification.

UNLABELLED: Nonuniform attenuation correction in brain SPECT can be done routinely by means of additional gamma transmission CT (TCT) measurements, using different commercially available line-source isotopes, 201Tl, 153Gd, and 99mTc are among the most commonly used isotopes, depending on practical and cost-effectiveness issues. We have measured additional radiation burden from static uncollimated brain SPECT transmission sources for these isotopes. The influence of the transmission isotope on brain quantification was also measured and compared with uniform attenuation correction for phantom and human data. Full iterative transmission and emission reconstruction were compared with filtered backprojection techniques. METHODS: Rod sources with 201Tl, 153Gd, and 99mTc were used on a triple-head gamma camera. Dosimetry was performed using LiF TLD-100 pellets and an anthropomorphic RANDO phantom. Effective dose equivalents were calculated on the basis of measured and extrapolated absorbed doses. For brain activity measurements, a Hoffman phantom was used. Images were corrected for scatter (triple-energy window) and were reconstructed by Chang attenuation correction and filtered backprojection as well as full iterative reconstruction (ordered-subsets expectation maximization [OSEM]). To study the effect of inhomogeneous bone attenuation, realistic measurements were performed on 10 young, healthy volunteers with 153Gd TCT. After stereotactic image realignment, a volume-of-interest analysis normalized to total counts was performed. RESULTS: Brain SPECT-TCT using 201Tl, 153Gd, and 99mTc produced total effective dose-rate equivalents of 50.3 +/- 11.2, 32.0 +/- 2.7, and 71.1 +/- 7.1 microSv/GBq x h, respectively, representing dose equivalents of 18.6, 11.9, and 26.3 microSv for a typical 20-min brain SPECT scan at maximal used source strength. Standardized quantification resulted in insignificant differences between the isotopes and methods (Chang versus OSEM) used for nonuniform correction. Iterative reconstruction enhanced image contrast and provided more accurate gray-to-white matter ratios. Between nonuniform and uniform attenuation with an optimized attenuation coefficient, slight central discrepancies were found for volunteer studies. Significantly lower intersubject variation was found for nonuniform corrected values in infratentorial and posterior brain regions. CONCLUSION: Brain transmission scanning using 201Tl, 153Gd, or 99mTc results in limited effective radiation dose equivalents compared with the typical radiation burden. Relative brain perfusion quantification is not significantly different for the various nonuniform TCT isotopes. Iterative reconstruction improves gray-to-white contrasts but has no significant influence on brain perfusion semiquantification. Nonuniform attenuation correction decreases intersubject variability in the posterior brain regions that were compared, which may lead to improved sensitivity toward clinical applications.

Adult↗

Molecular quantification of response to therapy and remission status in TEL-AML1-positive childhood ALL by real-time reverse transcription polymerase chain reaction.

Although TEL-AML1 positivity [translocation t(12;21)(p13;q22)], detected in 20-25% of initial childhood acute lymphoblastic leukemia (ALL), has been associated with an excellent prognosis, its positive predictive value is insufficient for appropriate treatment stratification considering reported prevalence in relapsed ALL (3-28%). Molecular quantification of response to therapy by PCR-based methods has been shown to improve risk assessment. Here, we report on the sensitive quantification of leukemia-specific TEL-AML1 fusion transcript levels normalized to beta-actin expression (sensitivity threshholds, 10(-5)) by a novel real-time reverse transcription-PCR (RQ-RT-PCR) based on fluorescent TaqMan technique providing early and rapid evidence on the treatment efficacy of children with initial or relapsed TEL-AML1+ ALL enrolled in frontline or relapse trials of the Berlin-Frankfurt-Münster (BFM)-Study Group. In initial ALL, TEL-AML1/beta-actin decrease was > or =10(5)-fold in 50% of patients after induction therapy (day 33) and stayed TEL-AML1-negative throughout therapy, which suggested high sensitivity of leukemic cells to antineoplastic therapy. The remaining patients were still TEL-AML1+ before reintensification (ratios, 0.7 x 10(-2):10(-4)). In relapsed ALL, TEL-AML1/beta-actin decrease was generally less pronounced at corresponding time points, and conversion to TEL-AML1 negativity was observed in 40% of patients. Most notably, subsequent relapses occurred only among molecular poor responders, whereas all early responders remain in their second complete remission. In conclusion, real-time quantification of TEL-AML1/beta-actin kinetics distinguishes distinct molecular response groups, and provides indications capable of directing therapeutic interventions for patients with TEL-AML1+ ALL. Before considering modification of therapy, results should be interpreted cautiously taking into account the long duration of remission associated with TEL-AML1+ ALL.

Actins↗

Absolute quantification of regional myocardial uptake of 99mTc-sestamibi with SPECT: experimental validation in a porcine model.

UNLABELLED: We have evaluated a method for absolute in vivo quantification of 99mTc-sestamibi uptake in a porcine model of myocardial perfusion. METHODS: Correlated CT and radionuclide images were obtained from eight adult pigs using a combined CT-SPECT imaging system. In each case, the CT image is used to generate an object-specific attenuation map that is incorporated into an iterative algorithm for reconstruction and attenuation correction of the radionuclide image. Anatomic information available from the correlated CT image is used to correct the radionuclide image for partial-volume errors by mathematically modeling the radionuclide imaging process. A volume of interest, or template, that approximates the geometric extent of the myocardium is defined from the CT image. Once defined, the template is assigned unit activity and is mathematically projected using a realistic physical model of the radionuclide imaging process including nonideal collimation and object-specific attenuation. The template is then reconstructed from these projections to obtain a pixel-by-pixel partial-volume correction for the myocardium in the radionuclide image. The CT image is also used to delimit the anatomic boundaries of the myocardium for quantification of the radionuclide images. The pixel intensities in the corrected radionuclide image are calibrated in units of activity concentration (MBq/g) and compared with the ex vivo activity concentration measured directly from the excised myocardium. RESULTS: Without corrections, the measured in vivo activity concentration in the porcine myocardium was only 10% of the true value. Correcting for object-specific attenuation improved the accuracy of this measurement but resulted in values that were still only 42% of the true value. By correcting for both attenuation and partial-volume errors, we were able to achieve absolute quantification with an accuracy error near 10%. CONCLUSION: We have shown that, by applying object-specific attenuation corrections and suitable partial-volume corrections, absolute regional activity concentration can be measured accurately in the porcine myocardium.

Animals↗

Quantification of histochemical staining by color deconvolution.

OBJECTIVE: To develop a flexible method of separation and quantification of immunohistochemical staining by means of color image analysis. STUDY DESIGN: An algorithm was developed to deconvolve the color information acquired with red-green-blue (RGB) cameras and to calculate the contribution of each of the applied stains based on stain-specific RGB absorption. The algorithm was tested using different combinations of diaminobenzidine, hematoxylin and eosin at different staining levels. RESULTS: Quantification of the different stains was not significantly influenced by the combination of multiple stains in a single sample. The color deconvolution algorithm resulted in comparable quantification independent of the stain combinations as long as the histochemical procedures did not influence the amount of stain in the sample due to bleaching because of stain solubility and saturation of staining was prevented. CONCLUSION: This image analysis algorithm provides a robust and flexible method for objective immunohistochemical analysis of samples stained with up to three different stains using a laboratory microscope, standard RGB camera setup and the public domain program NIH Image.

Algorithms↗

Rapid quantification of human ABCA1 mRNA in various cell types and tissues by real-time reverse transcription-PCR.

BACKGROUND: The ABCA1 gene encodes for a member of subfamily A of the ATP-binding cassette transporters that plays an important role in cellular export of cholesterol and phospholipids; therefore, quantification of the ABCA1 mRNA is critical in many studies related to its expression and regulation by metabolic factors, nutritional status, and new antiatherogenic drug candidates. We developed a rapid, sensitive, specific, and reproducible real-time reverse transcription-PCR (RT-PCR) method for detection and quantification of ABCA1 transcripts in total RNA isolated from cultured human cells and tissues. METHODS: To quantify ABCA1 mRNA, we generated a calibration curve from serial dilutions of in vitro-transcribed RNA corresponding to an amplified ABCA1 cDNA 205-bp fragment (homologous calibrator). Two pairs of fluorescent hybridization probes were used to detect the ABCA1 and porphobilinogen deaminase (PBGD) mRNAs; the latter served as an internal control. PCR was performed as real-time amplification of ABCA1 mRNA in 100 ng of total RNA isolated from various human tissues, and cultured cells were calculated from the calibration curve. In addition, normalized values of target (ABCA1/PBGD ratio) were calculated. RESULTS: Using this method, we quantified ABCA1 transcripts in various human tissue samples as well as in monocytes, THP-1 cells, fibroblasts, and adipocytes. We demonstrated ABCA1 mRNA up-regulation during human adipocyte and monocyte differentiation. In addition, we examined the effect of cholesterol loading and deloading on ABCA1 expression in monocytes, THP-1 cells, and fibroblasts. CONCLUSIONS: Our RT-PCR assay allows the specific and highly reproducible detection and quantification of minute amounts of human ABCA1 mRNA. This new method is more accurate, more informative, and less laborious than the classic RT-PCR methods and Northern blot; it therefore could simplify all studies on ABCA1 mRNA expression.

ATP Binding Cassette Transporter 1↗

[An approach for comparative quantification of myocardial blood flow (O-15-H2O-PET), perfusion (Tc-99m-tetrofosmin-SPECT) and metabolism (F-18-FDG-PET)].

AIM: In the present study a new approach has been developed for comparative quantification of absolute myocardial blood flow (MBF), myocardial perfusion, and myocardial metabolism in short-axis slices. METHODS: 42 patients with severe CAD, referred for myocardial viability diagnostics, were studied consecutively with 0-15-H2O PET (H2O-PET) (twice), Tc-99m-Tetrofosmin SPECT (TT-SPECT) and F-18-FDG PET (FDG-PET). All data sets were reconstructed using attenuation correction and reoriented into short axis slices. Each heart was divided into three representative slices (base, midventricular, apex) and 18 ROIs were defined on the FDG PET images and transferred to the corresponding H2O-PET and TT-SPECT slices. TT-SPECT and FDG-PET data were normalized to the ROI showing maximum perfusion. MBF was calculated for all left-ventricular ROIs using a single-compartment-model fitting the dynamic H2O-PET studies. Microsphere equivalent MBF (MBF_micr) was calculated by multiplying MBF and tissue-fraction, a parameter which was obtained by fitting the dynamic H2O-PET studies. To reduce influence of viability only well perfused areas (> 70% TT-SPECT) were used for comparative quantification. RESULTS: First and second mean global MBF values were 0.85 ml x min-1 x g-1 and 0.84 ml x min-1 x g-1, respectively, with a repeatability coefficient of 0.30 ml x min-1 x g-1. After sectorization mean MBF_micr was between 0.58 ml x min-1 x ml-1 and 0.68 ml x min-1 x ml-1 in well perfused areas. Corresponding TT-SPECT values ranged from 83% to 91%, and FDG-PET values from 91% to 103%. All procedures yielded higher values for the lateral than the septal regions. CONCLUSION: Comparative quantification of MBF, MBF_micr, TT-SPECT perfusion and FDG-PET metabolism can be done with the introduced method in short axis slices. The obtained values agree well with experimentally validated values of MBF and MBF_micr.

Coronary Circulation↗

An activity quantification method based on registration of CT and whole-body scintillation camera images, with application to 131I.

UNLABELLED: This article presents a new method for conjugate view activity quantification for 131I-labeled monoclonal antibody distribution. METHODS: The method is based on the combined use of images from 3 modalities: whole-body (WB) scintillation camera scanning, WB transmission scanning using 57Co, and CT. All images are coaligned using a recently developed program for the registration of WB images. Corrections for attenuation, scatter, and septal penetration are performed in image space. Compensation for scatter and septal penetration is performed by deconvolution, using point-response functions determined from Monte Carlo simulations. Attenuation correction is performed by applying a patient-specific 364-keV narrow-beam attenuation map obtained by combining information from the CT and the transmission scan. A relationship is presented for the conversion of the CT numbers to mass density. The attenuation- and scatter-compensated image is converted from counts to activity using a sensitivity value that was determined for 364-keV photons in air. This activity projection image is then analyzed for the activity of volumes of interest (VOI) using 2-dimensional regions of interest (ROIs) that are determined from the CT study. The CT is first resliced into coronal slices, and a maximum-extension ROI is outlined that encloses the VOI. Compensation for background activity and overlapping organs is performed on the basis of total patient thickness in the projection line, and on precalculated organ- background thickness fractions. RESULTS: Method evaluation was performed using data from both experimental measurements and Monte Carlo simulations. The use of an attenuation map derived directly from the CT study was also evaluated. For organ activity quantification, an accuracy of > or =10% was obtained. For small-diameter tumors, deviations were larger because of lack of correction for the background-dependent partial-volume effect. CONCLUSION: Registration of CT and WB scintillation camera images was successfully applied to improve activity quantification by the conjugate view method.

Antibodies, Monoclonal↗