Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Comparison of high-resolution echo-planar spectroscopic imaging with conventional MR imaging of prostate tumors in mice.

High spectral and spatial resolution (HiSS) MRI of rodent tumors has previously been performed using conventional spectroscopic imaging to obtain images with improved contrast and anatomic detail. The work described here evaluates the use of much faster echo-planar spectroscopic imaging (EPSI) to acquire HiSS data from rodent tumor models of prostate cancer. A high-resolution EPSI pulse sequence was implemented on a 4.7 T Bruker scanner. Three-dimensional EPSI data were Fourier-transformed along the k-space and temporal (free-induction decay) axes to produce detailed water and fat spectra associated with each small image voxel. The data were used to generate images of spectral parameters, e.g. peak-height images for each small voxel. Two variants of EPSI were performed; gradient-echo or spin-echo excitation with EPSI readout. These imaging methods were tested in commonly used rodent prostate cancers, including seven mice implanted with non-metastatic AT2.1 (n=3) and metastatic AT3.1 (n=4) prostate tumors on the hind leg, and 10 mice implanted with LNCaP prostate cancers in situ. The peak-height images derived from EPSI datasets provide more detailed tumor anatomy, improved signal-to-noise and contrast-to-noise ratios compared with the gradient-echo or spin-echo images at all echo times. The results suggest that HiSS MRI data from small animal models of prostate cancer can be acquired using EPSI, and that this approach improves imaging of heterogeneous tissue and vascular environments inside the tumors compared with conventional MR techniques.

Animals↗

Image compression for medical imaging systems.

The physical size of typical digital images, in terms of the number of bytes of data one image contains, is large; e.g., a 1024 X 1024 image with 8 bits of data per pixel contains a megabyte of data. To transmit many such images over a network, sometimes over low-capacity phone lines to remote sites, or to store large numbers of images over a long period of time as part of the medical records for patients, the need for image compression arises to alleviate these large demands for image data storage and transmission capacity. This paper discusses image compression in terms of the information theory upon which it is based. The two basic categories of algorithms for implementing image compression are presented along with considerations for image quality and accuracy, which are of primary importance to the medical imaging community.

Diagnostic Imaging↗

Use of automated image registration to generate mean brain SPECT image of Alzheimer's patients.

UNLABELLED: The purpose of this study was to compute and compare the group mean HMPAO brain SPECT images of patients with senile dementia of Alzheimer's type (SDAT) and age matched control subjects after transformation of the individual images to a standard size and shape. METHODS: Ten patients with Alzheimer's disease (age 71.6 +/- 5.0 yr) and ten age matched normal subjects (age 71.0 +/- 6.1 yr) participated in this study. Tc-99m HMPAO brain SPECT and X-ray CT scans were acquired for each subject. SPECT images were normalized to an average activity of 100 counts/pixel. Individual brain images were transformed to a standard size and shape with the help of Automated Image Registration (AIR). Realigned brain SPECT images of both groups were used to generate mean and standard deviation images by arithmetic operations on voxel based numerical values. Mean images of both groups were compared by applying the unpaired t-test on a voxel by voxel basis to generate three dimensional T-maps. X-ray CT images of individual subjects were evaluated by means of a computer program for brain atrophy. RESULTS: A significant decrease in relative radioisotope (RI) uptake was present in the bilateral superior and inferior parietal lobules (p < 0.05), bilateral inferior temporal gyri, and the bilateral superior and middle frontal gyri (p < 0.001). The mean brain atrophy indices for patients and normal subjects were 0.853 +/- 0.042 and 0.933 +/- 0.017 respectively, the difference being statistically significant (p < 0.001). CONCLUSION: The use of a brain image standardization procedure increases the accuracy of voxel based group comparisons. Thus, intersubject averaging enhances the capacity for detection of abnormalities in functional brain images by minimizing the influence of individual variation.

Aged↗

Impact of image size on effectiveness of digital imaging systems.

Radiologists detect small diagnostic signals in radiographic film images by altering the distance between the eye and the image, effectively zooming in on a particular detail. Details thus enlarged are more perceptible to the viewer. Considering that conventional film images are nearly life-size, the potential for increasing the detection of small signals in this manner is high. Digital images, however, presented in video format are usually smaller than life-size, sometimes more than 50% smaller. While local enlargements using computer-based imaging systems are extremely useful, the radiologist cannot examine a whole, life-size image. The importance of the latter in the diagnostic process is revealed in detection studies using the same images of a chest phantom with small nodular inclusions, in different size formats. A clear positive correlation exists between overall image size and the detection of signals that are of a diagnostically-relevant size. While it is widely accepted that image fidelity is an important determinant in the clinical acceptability of digital radiography, digital image displays should also be large enough to display life-size images.

Humans↗

An image processing system for digital chest X-ray images.

This paper investigates the requirements for image processing of digital chest X-ray images. These images are conventionally recorded on film and are characterised by large size, wide dynamic range and high resolution. X-ray detection systems are now becoming available for capturing these images directly in photoelectronic-digital form. In this report, the hardware and software facilities required for handling these images are described. These facilities include high resolution digital image displays, programmable video look up tables, image stores for image capture and processing and a full range of software tools for image manipulation. Examples are given of the application of digital image processing techniques to this class of image.

Computers↗

A statistical method for evaluation quality of medical images: a case study in bit discarding and image compression.

Many studies have been performed on quality evaluation for subtle differences in medical images. However, only limited success has been achieved. In this paper, medical images were prior manipulated by denoising, lossy compression and filtering. The Moran statistics is then applied to extract spatial information of images and using Kolmogorov-Smirnov (KS) test to determine whether the manipulated and original images differ significantly. Results show that on average discarding 1-2 bits in T1 and CR images or 2-3 bits in T2 and body CT images are indistinguishable. This method is also applied to a reconstructed MR, body CT image and an electronic SMPTE (Society of Motion Picture and Television Engineer) phantom from lossy image compression software. Compression ratios of 16:1 for a MR image, 8-9:1 for a cropped body CT image, 7:1 and 5:1 for high- and low-resolution regions in electronic phantom is proved undifferentiated from original. The proposed method is useful for complementing the human visual system, to optimize the performance of image compression technique.

Data Interpretation, Statistical↗

Comparing elastographic strain images with modulus images obtained using nanoindentation: preliminary results using phantoms and tissue samples.

Conventional elastography involves quasistatic mechanical compression (external or internal) of the tissue under ultrasonic insonification to obtain radiofrequency (RF) A-lines before and after compression. Cross-correlation of the pre- and postcompression A-lines results in displacement images with axial gradients that produce the strain images (strain elastograms). Though the strain elastograms show structural similarities to the modulus images, they are not related in a simple way to the modulus images because the strains depend on both modulus and geometry of the materials being deformed. Therefore, a quantification of the similarities between the strain and modulus images may enhance the interpretation confidence of strain elastograms in depicting tissue structure. To demonstrate similarities between modulus images and strain elastograms, a feasibility study of using nanoindentation to obtain modulus images of thin slices of tissue and tissue-mimicking phantoms (agar-gelatin mixtures) was performed first, with encouraging results. This was followed by a comparison of modulus images and strain elastograms obtained from the same sample slices. The experimental results indicated that, under certain experimental conditions, it is feasible to perform quantitative comparisons between strain images (using elastography) and modulus images. A good visual, as well as quantitative, correspondence between structures in the modulus and strain images could be obtained at a 3-mm scale.

Agar↗

T1-weighted images with ECG gating using partial flip angle spin-echo imaging.

ECG-gated spin-echo imaging can reduce vascular artefacts compared with spin-echo scans without gating. However, this method produces poor T1-weighted images because the repetition time (TR) is limited by the heart rate. We investigated the value of low flip angle spin-echo imaging for increasing T1-dependent contrast when using ECG gating. Using computer simulation, the predicted contrast increased with decreasing the flip angle, and the effect was almost saturated at a flip angle of around 40 degrees. With the application of this flip angle, the identical image contrast as a T1-weighted image (TR = 400 ms) can be obtained within the heart rate range of 65 to 75 beats/min. For clinical evaluation, the tissue contrast index values ((signal intensity in the lesion-signal intensity in the muscle)2 x 100/signal intensity in the muscle) obtained by conventional spin-echo and low flip angle spin-echo imaging were compared in 17 patients. The contrast index of low flip angle spin-echo images (74.0 +/- 52.0) was significantly higher than that of conventional spin-echo images (40.9 +/- 35.9). Thus, ECG-gated low flip angle spin-echo imaging provided better T1-dependent contrast than conventional ECG-gated spin-echo imaging. This method may be especially useful for Gd-DTPA-enhanced magnetic resonance imaging.

Aged↗

MRI-FLAIR images of the head show corticospinal tract alterations in ALS patients more frequently than T2-, T1- and proton-density-weighted images.

In some patients with amyotrophic lateral sclerosis (ALS), T2-weighted and proton-density-weighted magnetic resonance imaging (MRI) shows hyperintense or hypointense signals at the corticospinal tract. Fluid-attenuated inversion recovery (FLAIR) sequences increase the sensitivity of MRI to detect cortical and subcortical tissue changes. In 31 ALS patients and 33 controls, we studied the frequency and the extent of signal abnormalities in FLAIR images compared to T2-, T1- and proton-density-weighted images. Hyperintense signals at the corticospinal tract were significantly more frequent in FLAIR images than in all other tested sequences. In FLAIR images of ALS patients only, distinct hyperintense signals at the subcortical precentral gyrus (five patients), the centrum semiovale (eight patients), the crus cerebri (nine patients) and the pons (four patients) as well as mild hyperintense signals in the medulla oblongata (three patients) were seen. More frequently, but not exclusively in ALS patients, FLAIR images showed mild hyperintense signals at the subcortical precentral gyrus (15 patients vs. 1 control). Quantitative analysis confirmed the significant difference between ALS patients and controls at the subcortical precentral gyrus in FLAIR images. In T1-weighted images, the corticospinal tract at the capsula interna was hypointense in significantly more controls than ALS patients. Also this difference was confirmed in the quantitative analysis. Similar to previous results, MR image alterations did correlate poorly to clinical data of upper motor neuron affliction.MR images of the head, including FLAIR images, provide additional information regarding corticospinal tract involvement in ALS patients. Because of an overlap with physiological findings, they have to be interpreted cautiously, with the exception of hyperintense signals at the subcortical precentral gyrus.

Adult↗

Magnetic resonance imaging: utility as a molecular imaging modality.

Significant scientific effort has gone into the deconvolution and understanding of complex biological systems. These efforts have yielded much information about the molecular changes that are causative or arise as a result of disease. Molecular imaging is a relatively newer field that is attempting to use these molecular data to generate images that report on changes in gene expression. It has been demonstrated that generating images based on molecular differences rather than anatomical differences between tissues has resulted in more sensitive detection of diseased tissues and has allowed imaging of drug efficacy against particular drug targets. This chapter discusses the application of magnetic resonance imaging (MRI) to molecular imaging. It begins with a review of the basis for magnetic resonance image generation and how manipulation of different parameters of the system can be applied to molecular imaging. It then specifically reviews some of the problematic areas for magnetic resonance application to molecular imaging and how these can be resolved by manipulating the magnetic resonance system, altering magnetic resonance probe characteristics, or exploiting the biology to be imaged. It concludes with several examples demonstrating the utility of MRI to generate high-resolution, noninvasive images of molecular events occurring in vivo.

Animals↗

Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging.

PURPOSE: The development of the first prototype active matrix flat-panel imager (AMFPI) capable of radiographic and fluoroscopic megavoltage operation is reported. The signal and noise performance of individual pixels is empirically quantified. Results of an observer-dependent study of imaging performance, using a contrast-detail phantom, are detailed and radiographic patient images are shown. Finally, a theoretical investigation of the zero-frequency detective quantum efficiency (DQE) performance of such imagers, using a cascaded systems formalism, is presented. METHODS AND MATERIALS: The imager is based on a 508-microm pitch, 26 x 26 cm2 array which detects radiation indirectly via an overlying copper plate + phosphor screen converter. RESULTS: Due to its excellent optical coupling, the imager exhibits sensitivity superior to that of video-based systems. With an approximately 133 mg/cm2 Gd2O2S:Tb screen the system is x-ray quantum-noise-limited down to approximately 0.3 cGy, conservatively, and extensions of this behavior to even lower doses by means of reduced additive electronic noise is predicted. The observer-dependent study indicates performance superior to that of conventional radiotherapy film while the patient images demonstrate good image quality at 1 to 4 MU. The theoretical studies suggest that, with a 133 mg/cm2 Gd2O2S:Tb screen, the system would provide DQE performance equivalent to that of video-based systems and that almost a factor of two improvement in DQE is achievable through the incorporation of a 400 mg/cm2 screen. CONCLUSION: The reported prototype imager is the first megavoltage AMFPI having performance characteristics consistent with practical clinical operation. The superior contrast-detail sensitivity of the imager allows the capture of high-quality 6- and 15-MV images at minimal dose. Moreover, significant performance improvements, including extension of the operational range up to full portal doses, appear feasible. Such capabilities could be of considerable practical benefit in patient localization and verification.

Aged↗

Imaging freely moving subjects using continuous interleaved orthogonal magnetic resonance imaging.

Magnetic resonance imaging has shown increasing clinical utility for the diagnosis of abnormalities in fetal development. MRI is not yet as effective for fetal imaging as ultrasound because of the difficulty of imaging freely moving subjects. We describe a design approach to overcome this difficulty. By interleaving orthogonal images of a subject, it is possible to rapidly and interactively localize the scan plane in a moving subject and confirm image plane orientation relative to the subject. We derive the equations necessary to optimize the tip angles for the acquisition of the orthogonal images so as to minimize artifact in the main image despite the long T1 of a fluid environment (e.g., amniotic fluid). To fully utilize the orthogonal images for rapid localization, it is critical to minimize the delay between acquisition and display, and to avoid segmented reconstruction techniques that are commonly used in high frame rate imaging. We demonstrate that this approach can be used to perform interactive scan plane localization on a moving subject and can obtain high temporal resolution images while confirming the image plane orientation relative to the subject.

Algorithms↗

Quantitative split dose thallium-201 imaging with exercise: a technique for obtaining rest and exercise perfusion images in one setting and markedly reducing the study time.

In the current study, a technique for performing serial thallium imaging after two separate tracer injections was applied to exercise thallium imaging, thus allowing the acquisition of rest and exercise images within 1 hour. Twenty-four patients with and 10 patients without significant coronary artery disease were studied. One mCi of thallium-201 was injected intravenously and imaging was performed at rest in three projections. The patient was then stressed and an additional 1 mCi of thallium injected during exercise. Images in the same three projections were collected. After computer realignment, the rest image was subtracted from the exercise image to produce an image representing perfusion during exercise. All 24 patients with coronary artery disease had a positive study, while 9 of 10 without disease had a negative study. The images were then interpreted using a computer method designed to quantitate regional myocardial thallium distribution and redistribution. With quantitative interpretation, 23 of 24 patients with coronary disease had a positive study, while only 1 without disease had a positive study. With qualitative interpretation, 39 (89%) of 44 stenosed coronary arteries demonstrated thallium defects in corresponding myocardial segments, while 54 (93%) of 58 nonstenosed coronary arteries did not. With quantitative interpretation, 38 (86%) of 44 stenosed coronary arteries demonstrated thallium defects in corresponding myocardial segments, while 53 (91%) of 58 nonstenosed coronary arteries did not. A split dose thallium imaging technique that allows imaging before and immediately after exercise, thus markedly reducing the study time, has been validated.

Adult↗

Imaging end-stage kidney disease in adults. Low-field MR imaging with magnetization transfer vs. ultrasonography.

PURPOSE: To 1) assess the potential of magnetization transfer (MT)-weighted MR imaging to improve the often poor visibility of native kidneys in patients with a renal transplant; and 2) compare low-field MR imaging and ultrasonography (US) for imaging these fibrotic kidney remnants. MATERIAL AND METHODS: Seventy-two native kidneys of 36 patients were prospectively evaluated with US and MR. In low-field (0.1 T) MR imaging, T1-, T2- and MT-weighted sequences were used. MT-weighted images were compared with T2-weighted images in their ability to delineate the kidneys from their surroundings whereas US and MR were compared for detection of renal cysts and possible solid tumors. RESULTS: MT-weighted images proved superior to conventional T2-weighted images in producing contrast between the kidney remnants and their fatty surroundings. Although US revealed a few small renal cysts that were not seen at MR images, no statistical difference was found between the two modalities in this respect. CONCLUSION: MT imaging, due to its unique protein-specific signal depression, offers significantly improved visualization and delineation of end-stage kidneys. US, because its better availability and cost-benefit ratio, remains the method-of-choice compared to low-field MR imaging in detecting cysts in multicystic kidneys. MR investigation is helpful in selected patients and may be used as an alternative.

Adult↗

MnDPDP for MR imaging of the liver. Results of an independent image evaluation of the European phase III studies.

PURPOSE: To evaluate the diagnostic efficacy of mangafodipir trisodium (MnDPDP, Teslascan) as a new contrast agent for MR imaging of the liver based on an independent evaluation of the MR images from the European phase III studies. MATERIAL AND METHODS: MR imaging of the liver was done at 0.5-2.0 T in 17 European centres and included T1-weighted spin-echo and gradient-echo sequences before and after administration of MnDPDP to patients at a dose of 5 mumol/kg b.w. T2-weighted images were also obtained in all cases before the i.v. injection of the agent. Images of a total of 592 patients were evaluated by 4 independent experienced radiologists who were not involved in the on-site clinical trials. RESULTS: Statistically significantly more lesions were detected (p = 0.0014) in MnDPDP-enhanced T1-weighted MR images than in unenhanced images. T1-weighted gradient-echo sequences were found to be superior to T1-weighted spin-echo sequences after injection of MnDPDP. The post-contrast images were found to be statistically significantly superior to the pre-contrast images in confidence in the presence of a lesion (p < or = 0.0001), quality of lesion delineation (p < or = 0.0001), lesion conspicuity (p < or = 0.0001) and in the confidence in the diagnosis of a lesion (p = 0.001). CONCLUSION: This independent evaluation of the European phase III trials confirmed the superiority of MnDPDP-enhanced MR images over unenhanced images for lesion detection and characterization.

Adult↗

Multiple-slice spin lock imaging of head and neck tumors at 0.1 Tesla: exploring appropriate imaging parameters with reference to T2-weighted spin-echo technique.

RATIONALE AND OBJECTIVES: Spin lock imaging has been shown to be useful in characterizing head and neck tumors. The purposes of this study were to explore and develop multiple-slice spin lock gradient-echo (SL-GRE) sequences for head and neck imaging and to compare the tumor contrast on SL images to spin-echo (SE) T2-weighted images at 0.1 T. METHODS: On the basis of measured relaxation times of tumors and head and neck tissues, the authors evaluated with signal equations the effect of imaging parameters on tissue contrast produced by the SL-GRE sequence. In the clinical study, 34 patients with pathologically verified head and neck tumors were imaged with multiple-slice SL-GRE (repetition time 1500 ms/echo time 30 ms) out-of-phase fat/water sequences and compared with T2-weighted SE (repetition time 1500 ms/echo time 120 ms) sequences. The conspicuity of tumors was evaluated by calculating the contrast-to-noise ratios (CNRs). RESULTS: The combination of a short echo time of 30 ms and the length of locking pulses in the range of 10 to 35 ms produced optimal CNRs for head and neck tumor imaging. The measured CNRs and subjective evaluation for tumor detection were satisfactory with both imaging sequences. However, the CNRs between tumors and salivary gland tissues were significantly greater with the SL sequence than with the T2-weighted sequence. CONCLUSIONS: The multiple-slice SL-GRE technique provides image contrast comparable to that of SE T2-weighted imaging for head and neck tumors at 0.1 T. With short locking pulse lengths and echo times, wide anatomic coverage and reduced motion and susceptibility artifacts can be achieved. The out-of-phase SL technique is useful in imaging salivary gland tumors.

Head and Neck Neoplasms↗

Comparison of contrast-enhanced magnetization transfer imaging and contrast-enhanced fat saturation T1-weighted imaging in nasopharyngeal carcinoma.

OBJECTIVE: The objective of this study was to evaluate the efficacy of contrast-enhanced magnetization transfer (CEMT) imaging in the study of nasopharyngeal carcinoma (NPC). METHODS: The contrast-to-noise ratio (CNR) of CEMT images was compared with the CNR of contrast-enhanced fat-saturation (CEFS) T1-weighted images in locoregional tumors and adenopathies of 50 patients with pathologically proven NPC. RESULTS: The CEMT images showed higher CNRs than CEFS images of local nasopharyngeal regions. The mean CNRs of the precontrast T1-weighted, CEFS, and CEMT images were 4.9, 15.4, and 21.2, respectively. There was a statistically significant difference (p < 0.01) in the CNRs of CEFS and CEMT images. In considering images of nodal metastasis, the mean values in these three groups were 0.7, 16.8, and 19.7, respectively, with the difference (p < 0.05) between CEFS and CEMT being statistically significant. CONCLUSIONS: The CEMT image with a larger CNR is superior to the CEFS image in detecting locoregional NPC. CEMT can be useful in imaging patients with possible small tumors and local recurrences.

Adolescent↗

Comparison of 99mTc ciprofloxacin, 99mTc white blood cell and three-phase bone imaging in the diagnosis of hip prosthesis infections: improved diagnostic accuracy with extended imaging time.

The purpose of this study was to compare the utility of 99mTc labelled ciprofloxacin (Infecton) imaging with the 99mTc white blood cell and three-phase bone imaging procedures for identifying hip prosthesis infection. We studied 30 symptomatic patients in whom infection was confirmed in eight and excluded in 22 cases based on clinical and microbiological findings. 99mTc ciprofloxacin images were obtained at 1, 4 and 24 h after the injection of the tracer, and the data were compared to those obtained from 99mTc leukocyte and three-phase bone imaging. The 99mTc ciprofloxacin imaging correctly identified all true infections. In 13 (59%) of the non-infected patients, non-specific uptake of 99mTc ciprofloxacin was found in the 1-h and 4-h images, which disappeared, however, in the 24-h images. When the early and late 99mTc ciprofloxacin images were compared, the specificity was found to improve from 41% to 95%, positive predictive value from 38% to 89%, and the diagnostic accuracy from 57% to 97%. The accuracy of the conventional 99mTc leukocyte imaging was 90%. Dynamic bone imaging also yielded abnormal findings in all the infected patients although also in 23% of the non-infected patients. Current data indicate that 99mTc ciprofloxacin is a useful method for confirming hip prosthesis infection. The diagnostic efficiency of this method is improved when the imaging time is extended to 24 h post-injection of the tracer.

Adult↗