Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “deconvolution”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Deconvolution of infrequently sampled data for the estimation of growth hormone secretion.

In this paper, the deconvolution of infrequently and nonuniformly sampled data is addressed. A nonparametric technique is worked out that provides a smooth estimate of the unknown input signal and takes into account nonnegativity constraints. In spite of the size of the problem, efficient algorithms for solving the constrained optimization problem and computing confidence intervals are proposed. The new technique is used to estimate growth hormone (GH) secretion after repeated GH-releasing hormone (GHRH) administration from samples of blood concentration.

Adult↗

A deconvolution technique for improved estimation of rapid changes in ion concentration recorded with ion-selective microelectrodes.

In biological preparations, measurements of rapid, stimulus-evoked changes in ion concentration by ion-selective microelectrodes can be distorted by the limited bandwidth of these sensors. Techniques were developed to reconstruct the actual change in ion concentration using deconvolution of the electrode's output signal and the electrode's transfer function. In the vertebrate retina, a knowledge of the actual time course of a light-evoked increase in extracellular K+ concentration was used to provide a rigorous test of a hypothesis regarding the electrical origin of a clinically important component of the electroretinogram.

Animals↗

Three-dimensional blind deconvolution of ultrasound images.

Three-dimensional ultrasound images are blurred by the ultrasound pulse through the convolution between the 3-D tissue signal and the 3-D pulse. The blurring reduces the spatial resolution of the 3-D ultrasound images and, consequently, their diagnostic value. This paper presents a method for 3-D blind homomorphic deconvolution of medical 3-D ultrasound images to improve their spatial resolution. The blind estimate of the 3-D pulse is necessary because the pulse changes in spatial extent and frequency composition as it passes through the tissues and because the pulse is not separable in its spatial dimensions. The method was tested on a 3-D image of a phantom with anechoic spheres of known size in a uniform diffuse scattering matrix. The spheres were clearly better defined and had volumes much closer to the true volume in the deconvolved image than in the original image.

Biomedical Engineering↗

Absorption and in vivo dissolution of hydroxycholoroquine in fed subjects assessed using deconvolution techniques.

1. Nine healthy subjects each received three doses of 155 mg rac-hydroxychloroquine, as a tablet, an oral solution and by intravenous infusion, in a randomised cross-over design study, 30 min after a standard high fat breakfast. 2. Four methods of deconvolution were used to assess the absolute bioavailability of the tablet and oral solution doses. These were the delta function method, the staircase approximation method, and two least squares methods using a single first-order input and a sequential first-order input. The mean (+/- s.d.) fraction absorbed estimated by the four methods was 0.64 +/- 0.14 after the tablet and 0.87 +/- 0.30 after the oral solution. Wide intersubject variability was observed (0.50-0.91 for the tablet; 0.30-1.37 for the solution). 3. The mean (+/- s.d.) absorption half-life was 3.7 +/- 2.0 h for the tablet and 3.3 +/- 1.6 h for the solution, suggesting that absorption following the tablet dose was not rate-limited by dissolution. 4. The in vivo dissolution rate, extent of release and lag-time were determined using cube-root law and first-order input functions. Dissolution was found to be rapid, after a significant lag-time, but incomplete in some subjects. 5. The rate and extent of absorption was similar to that reported previously for fasted subjects. The lag-time before absorption commenced in fed subjects (1.65 +/- 0.46 h) showed a significant three-fold increase over that reported previously in fasting subjects (0.63 +/- 0.33 h), but this difference is not likely to be of clinical significance.

Administration, Oral↗

The application of deconvolution analysis to elucidate the pulsatile nature of growth hormone secretion using a variable half-life of growth hormone.

A deconvolution analysis model to calculate pituitary growth hormone (GH) secretion rate from measured serum GH concentration has been developed. This uses an iterative method of 'curve-stripping' based on an estimate of the half-life. The model has been applied to serum GH profiles and demonstrates that GH secretion occurs in discrete bursts with quiescent periods between secretory episodes, an 'on-off' phenomenon. The model can clearly dissect complicated concentration profiles such as the serum GH concentration response to growth hormone releasing hormone. The estimate was derived from calculating the half-life of serum GH in 10 subjects following an intravenous bolus injection of 50 mU of biosynthetic human growth hormone (b-hGH) and following infusions of the exogenous hormone (3 mU/kg/h) for 15, 30, 60 and 180 min. Endogenous GH secretion was suppressed by a continuous infusion of somatostatin (1-14). An asymptotic relationship between the duration of GH infusion and the GH half-life was established. A half-life of 15.3 min was achieved after exposure to GH for 60 min and a maximum half-life of 15.7 min after 180 min exposure.

Adolescent↗

The deconvolution of pyrolysis mass spectra using genetic programming: application to the identification of some Eubacterium species.

Pyrolysis mass spectrometry was used to produce complex biochemical fingerprints of Eubacterium exiguum, E. infirmum, E. tardum and E. timidum. To examine the relationship between these organisms the spectra were clustered by canonical variates analysis, and four clusters, one for each species, were observed. In an earlier study we trained artificial neural networks to identify these clinical isolates successfully; however, the information used by the neural network was not accessible from this so-called 'black box' technique. To allow the deconvolution of such complex spectra (in terms of which masses were important for discrimination) it was necessary to develop a system that itself produces 'rules' that are readily comprehensible. We here exploit the evolutionary computational technique of genetic programming; this rapidly and automatically produced simple mathematical functions that were also able to classify organisms to each of the four bacterial groups correctly and unambiguously. Since the rules used only a very limited set of masses, from a search space some 50 orders of magnitude greater than the dimensionality actually necessary, visual discrimination of the organisms on the basis of these spectral masses alone was also then possible.

Artificial Intelligence↗

Determination of microscopic dissociation constants of 3-hydroxy-alpha-(methylamino)methyl-benzenemethanol by a spectral deconvolution method.

Microscopic dissociation constants of 3-hydroxy-alpha-(methylamino)methyl-benzenemethanol have been calculated from the titration spectrophotomeric data (c = 3.8 x 10(-4) M. Ionic strength = 0.16; buffer system: H3BO3/KOH) by application of a spectral deconvolution method. The results found (pKa = 9.48; pKb = 9.71; pKc = 10.12 and pKd = 9.88) are in good concordance with those obtained from the conventional regression linear method (pKa = 9.45; pKb = 9.77; pKc = 10.14 and pKd = 9.81).

Chemical Phenomena↗

Handling non-negativity in deconvolution of physiological signals: a nonlinear stochastic approach.

A stochastic interpretation of Tikhonov regularization has been recently proposed to attack some open problems of deconvolution when dealing with physiological systems, i.e., in addition to ill-conditioning, infrequent and nonuniform sampling and necessity of having credible confidence intervals. However, the possible violation of the non-negativity constraint cannot be dealt with on firm statistical grounds, since the model of the unknown signal is compatible with negative realizations. In this paper, we propose a new model of the unknown input which excludes negative values. The model is embedded within a Bayesian estimation framework to calculate, by resorting to a Markov chain Monte Carlo algorithm, a nonlinear estimate of the unknown input given by its a posteriori expected value. Applications to simulated and real hormone secretion/pharmacokinetic problems are presented which show that this nonlinear approach is more accurate than the linear one. In addition, more realistic confidence intervals are obtained.

Algorithms↗

Removal of image intensifier veiling glare by mathematical deconvolution techniques.

X-ray images acquired with an image intensifier detector system suffer from veiling glare, a low-frequency degradation described by a point spread function (PSF). The PSF has two experimentally determined parameters unique to a given image intensifier. This information is utilized to deconvolve the degradation from digitally acquired images. Results demonstrate a significant increase in contrast ratio of high-contrast objects after deconvolution and image restoration.

Animals↗

Deconvolution techniques for removing the effects of chemical shift in 19F nuclear magnetic resonance imaging of perfluorocarbon compounds.

Nuclear magnetic resonance (NMR) imaging of perfluorocarbon (PFC) emulsions and neat liquids has shown potential for in vivo oxygen imaging in blood and organ tissue. PFC compounds exhibit complicated NMR spectra caused by chemical shifts and spin-spin couplings which can lead to artifacts and degraded spatial resolution of resulting NMR images. To correct for the chemical shift artifacts, the technique of spectral deconvolution has been applied to NMR imaging of PFC compounds. The temporal filter for this process can be directly applied to raw free induction decay data in projection reconstruction or to spin-echo data in two-dimensional Fourier transform imaging techniques. The effect of chemical shift artifacts was demonstrated through the NMR imaging of two PFC compounds (F-tributylamine and F-decalin) in phantoms. Methods are presented and demonstrated which allow the chemical shift artifacts to be removed and true images of the spatial distribution of the PFC's to be recovered.

Blood Substitutes↗

X-ray scatter removal by deconvolution.

The distribution of scattered x rays detected in a two-dimensional projection radiograph at diagnostic x-ray energies is measured as a function of field size and object thickness at a fixed x-ray potential and air gap. An image intensifier-TV based imaging system is used for image acquisition, manipulation, and analysis. A scatter point spread function (PSF) with an assumed linear, spatially invariant response is modeled as a modified Gaussian distribution, and is characterized by two parameters describing the width of the distribution and the fraction of scattered events detected. The PSF parameters are determined from analysis of images obtained with radio-opaque lead disks centrally placed on the source side of a homogeneous phantom. Analytical methods are used to convert the PSF into the frequency domain. Numerical inversion provides an inverse filter that operates on frequency transformed, scatter degraded images. Resultant inverse transformed images demonstrate the nonarbitrary removal of scatter, increased radiographic contrast, and improved quantitative accuracy. The use of the deconvolution method appears to be clinically applicable to a variety of digital projection images.

Computer Simulation↗

Deconvolution of detector size effect for small field measurement.

Parametrization of the small fields employed in stereotactic applications is a painstaking process involving extensive film dosimetry to achieve acceptable beam edge definition. Use of cylindrical or spherical detectors for profile measurements would simplify data acquisition but add a volume averaging artifact to beam edge definition. We demonstrate a simple approach to unfolding the chamber size artifact from measured small beam profiles using typical cylindrical chambers. In comparison with film measurements we have found good agreement when the detector response function is deconvoluted from the measured profiles, although the amount of correction needed is fairly minimal for the detectors studied.

Film Dosimetry↗

Inverse radiosurgery treatment planning through deconvolution and constrained optimization.

An inverse radiosurgery treatment planning approach is presented which calculates conformal dose distributions for small, irregularly shaped targets. Two general approaches have been suggested for solution of the inverse radiotherapy problem: explicit and implicit. Explicit methods are typically fast, but generally require geometric and/or dosimetric simplifications. Implicit methods have also been used, but are computationally expensive because they require iterative manipulation of each beam's individual elements. The method presented here incorporates an integrated approach in order to efficiently solve the inverse problem without requiring simplifications which may affect the accuracy of the final result. A deconvolution algorithm (explicit approach) is utilized to determine the intensity modulation function for multiple user-selected beam's eye views of the desired dose distribution. A simulated annealing algorithm (implicit approach) then optimizes each beam's macroscopic weight. Additionally, this method is fully three-dimensional and accurately models phantom scatter by incorporating Monte Carlo generated energy deposition kernels into the dosimetry process. Several small target structure examples are presented and applicability of this methodology to larger targets for general radiotherapy cases is addressed.

Algorithms↗

Synthetic aperture imaging using sources with finite aperture: deconvolution of the spatial impulse response.

A method for ultrasonic synthetic aperture imaging using finite-sized transducers is introduced that is based on a compact, linear, discrete model of the ultrasonic measurement system developed using matrix formalism. Using this model a time-domain algorithm for deconvolution of the transducer's spatial impulse responses (SIRs) is developed that is based on a minimum mean square error (MMSE) criterion. The algorithm takes the form of a spatiotemporal filter that compensates for the SIRs associated with a finite-sized transducer at every point of the processed image. A major advantage of the proposed method is that it can be used for any transducer, provided that its associated SIRs are known. This is in contrast to the synthetic aperture focusing technique (SAFT), which treats the transducer as a point source. The performance of the method is evaluated with simulations and experiments, performed in water using a linear phased array. The results obtained using the proposed method are compared to those obtained with a classical time-domain SAFT algorithm. For a finite aperture source, it is clearly shown that the resolution obtained using the proposed method is superior to that obtained using the SAFT algorithm.

Journal Article↗

An improvement in the range resolution of ultrasonic pulse echo systems by deconvolution.

Ultrasonic pulse echo systems are often limited in range resolution by the bandwidth of the piezoelectric transducer. Significant improvements in the range resolution of such systems can be obtained by minimizing the effects of the transducer's dynamic response on the overall pulse echo process. An approach to minimize the effects of the transducer is developed from linear system and impulse response techniques. In essence, the pulse echo voltage of interest is deconvolved with a pulse echo reference voltage which is obtained from an air/water interface in the nearfield of the transducer . A computer study of the pulse echo process and the deconvolution process is presented to illustrate the nature of the improvement in range resolution for several cases of interest. Finally, experimental results are presented to illustrate the improvement using commercially available transducers.

Transducers↗

Performance of some sparseness criterion blind deconvolution methods in the presence of noise

A comparison of the spareseness (simplicity) norm criterion blind deconvolution methods of Cabrelli and Wiggins is made in order to ascertain relative performance for underwater acoustic transient source signal estimation, especially in the presence of noise. Both methods perform well at high signal-to-noise ratios, producing source estimates that are significant improvements over the original received signal for classification purposes. At moderate and lower SNRs, the Cabrelli method tends to generate results that are superior to the Wiggins method. This is especially true for a damped sinusoid transient source, for which the Wiggins method fails completely at lower SNRs, while the Cabrelli method can still produce good source estimates.

Journal Article↗

Maximum a posteriori deconvolution of ultrasonic signals using multiple transducers

A new method for deconvolution of ultrasonic pulse-echo measurements employing multiple-transducer setup is proposed in the paper. An optimal way of estimating the material reflection sequence for a linear signal generation model using maximum a posteriori estimation is proposed. The method combines the measurements from a number of transducers covering different frequency bands yielding an optimal estimate of the reflection sequence. The main idea of this approach is to complement the information unavailable from one transducer in some frequency bands with the information from the other transducers. The method is based on the assumption that the measurements are performed using transducers with identical apertures and apodization, which are located exactly at the same position relative to the test object during the measurement. An error analysis presented in the paper proves that when the above assumptions are fulfilled, the proposed method, by utilizing more data for estimation, consistently yields more accurate reflection sequence estimates than the classical Wiener filter. Experimental evidence is presented using both simulated and real ultrasonic data as a verification of the correctness of the multiple-transducer model and the estimation scheme. An illustration of the advantages of the method is also given using real ultrasonic data.

Journal Article↗

Growth hormone secretory rates in children as estimated by deconvolution analysis of 24-h plasma concentration profiles.

The kinetics of growth-hormone (GH) distribution and elimination was estimated in five GH-deficient children who received 11 intravenous single injections of GH. The plasma disappearance data were analyzed in terms of a two-compartment model. The kinetic parameters obtained were then used in calculating the GH-secretory rate by a numerical deconvolution technique. A simple formula was derived for calculation of the cumulated secretion from the area under the concentration curve of 145 healthy children of various ages, heights, and stages of puberty. The estimated 24-h GH secretion increased with age, corresponding to a two- to fourfold increase during the adolescence period. The highest secretions were found in pubertal stages 3-4. In prepubertal children the heights correlated markedly with the secretion of GH (r = 0.83). Thus an indication of the range of the GH secretion in normal growing children is found, which is important to estimate substitution doses for treatment of GH-deficient children.

Activity Cycles↗