Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TOMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Computed tomography and magnetic resonance tomography findings in children operated for anal atresia.

Computerised tomography and magnetic resonance tomography were performed in nine faecally incontinent patients more than eight years after rectoplasty for high imperforate anus. No statistically significant correlation was found between function, i.e. degree of faecal incontinence, and anatomical findings. Thus, in spite of a detailed demonstration of the post-operative anatomy, the information does not seem to be directly applicable in indicating a way to reoperate for faecal incontinence in this group of patients.

Adolescent↗

[Computed tomography, magnetic resonance tomography and echocardiography in hypertrophic cardiomyopathy].

The value of echo-cardiography, CT and magnetic resonance tomography was evaluated in 10 patients with hypertrophic cardiomyopathy. Echocardiography made the diagnosis in most cases. The diagnostic criteria depended on functional and morphological changes. CT and magnetic resonance can show thickening in the myocardium, either symmetrical or asymmetrical. Magnetic resonance tomography provides excellent demonstration of the myocardium and accurate delineation of the degree of hypertrophy. It is well suited for measuring cardiac wall thickness.

Adolescent↗

Feasibility of three-dimensional optical coherence tomography and optical Doppler tomography of malignancy in hamster cheek pouches.

OBJECTIVE: Hamster cheek pouches (HCP) with various degrees of 9,10-dimethyl-1,2-benzanthracene (DMBA)-induced dysplasia and malignancies were imaged with OCT/ODT in vivo and in vitro to assess the potential for three-dimensional high-resolution optical localization of airway malignancy. BACKGROUND DATA: Optical coherence tomography (OCT)/optical doppler tomography (ODT) provide potential capability for real-time in vivo high-resolution (2-20 microm) cross-sectional imaging of tissues and spatially resolved blood flow in microvasculature for pathology diagnostics. METHODS: DMBA was applied to the right side of the cheek pouch (HCP), and mineral oil (control) to the left side three times weekly for 10-18 weeks in Syrian Golden Hamsters using a standard protocol for malignancy induction. HCP were imaged in vivo with OCT/ODT as well as in vitro post-excision, using a prototype 1310-nm broadband superluminescent diode-based OCT/ODT device constructed in our laboratory. Three-dimensional images were constructed, and compared to standard and three-dimensional histology hematoxylin and eosin staining. RESULTS AND CONCLUSION: OCT imaging offered exceptional resolution of the HCP to depths of 1-2 mm and confirmed ability to detect dysplasia and malignancy. Three-dimensional OCT images were readily constructed, allowing visualization of extent and localization of tumor margins. ODT demonstrated increased vascularity in the area of neoplasia. OCT/ODT is a promising new technology for oral airway diagnostics.

Animals↗

Assessment of reversible myocardial dysfunction in chronic ischaemic heart disease: comparison of contrast-enhanced cardiovascular magnetic resonance and a combined positron emission tomography-single photon emission computed tomography imaging protocol.

AIMS: The aim of the study was to compare, in patients with chronic ischaemic cardiomyopathy, contrast-enhanced cardiovascular magnetic resonance (ce-CMR) imaging and a combined (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and (99m)Tc-sestamibi single-photon emission computed tomography (SPECT) protocols for the prediction of functional recovery after revascularization, as assessed by cine CMR. METHODS AND RESULTS: Twenty-nine patients with ischaemic cardiomyopathy (ejection fraction 32 +/- 10%) were investigated with ce-CMR and PET/SPECT. For the assessment of global and regional functions, cine CMR was performed at baseline and at 6 months follow-up. For ce-CMR, the segmental extent of hyperenhancement (SEH) was quantitated, and for PET/SPECT, different viability categories were defined according to a validated quantitative protocol. Functional improvement was related to the SEH by ce-CMR, as well as to the viability categories by PET/SPECT. Sensitivity and specificity for the prediction of functional recovery at follow-up was 97 and 68% for ce-CMR and 87 and 76% for PET/SPECT. The positive predictive value was identical for both techniques (73%). However, ce-CMR achieved a higher negative predictive value (93 vs. 77%, respectively), indicating that ce-CMR may be superior to PET/SPECT for the identification of segments unlikely to recover function after revascularization. Both methods had a similar yield in the prediction of global functional improvement. CONCLUSION: ce-CMR is comparable with a PET/SPECT imaging protocol for the prediction of regional and global functional improvement after revascularization. However, ce-CMR may be superior to nuclear imaging for the identification of segments that are unlikely to recover function at follow-up.

Chronic Disease↗

Physiologic uterine uptake of FDG during menstruation demonstrated with serial combined positron emission tomography and computed tomography.

F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) has been used extensively to stage, restage, and follow neoplastic disease. However, focal accumulation of FDG may cause false-positive results in certain physiologic conditions. In this report, a unique PET and computed tomography (CT) combination scan helped define physiologic accumulation of FDG in the uterus during menstruation in a 40-year-old woman with a history of rectal melanoma and possible recurrent disease. An initial PET study, performed during menstruation, was followed immediately by a PET-CT scan, which showed marked accumulation of FDG in the posterior pelvis, localized to a retroverted uterus. An FDG PET-CT scan repeated 2 weeks later confirmed resolution of this "lesion." Thus, combined PET-CT correctly differentiated physiologic FDG uptake in a retroverted uterus from recurrent rectal melanoma. This case shows that physiologic FDG accumulation in the uterus should be considered when focal FDG accumulation is observed in the pelvis in women of reproductive age.

Adult↗

Evaluation of the hepatic artery in potential donors for living donor liver transplantation by computed tomography angiography using multidetector-row computed tomography: comparison of volume rendering and maximum intensity projection techniques.

PURPOSE: To compare the volume rendering (VR) and maximum intensity projection (MIP) computed tomography angiography (CTA) techniques using multidetector-row CT for hepatic artery evaluation of potential donors for living donor liver transplantation (LDLT). METHOD: Over a 9-month period, CTA using multidetector-row CT and conventional angiography was performed in 62 consecutive potential donors for LDLT. Acquisition of arterial phase scans was initiated within 5 seconds after reaching enhancement of the descending aorta up to 70 HU as measured by a bolus-tracking technique (collimation = 1.25 mm, table speed = 7.5 mm, reconstruction interval = 0.625 mm). Postprocessing was performed on a commercially available workstation. Computed tomography angiography images of the hepatic artery were made using the VR and MIP techniques. A total of 10 to 30 images of various planes were generated to reveal the origins and branching patterns of hepatic arteries. With a 2-week interval, two reviewers separately evaluated CTA using VR and MIP techniques, specifically evaluating anatomic variations and hepatic arterial conspicuity. The results of conventional angiography were considered to represent the gold standard. The difference in postprocessing time between the two techniques was statistically analyzed by the Student t test, and the differences in arterial conspicuity and in the identified number of the hepatic artery to segment IV of the liver were analyzed by the chi2 test. RESULTS: Two CT examinations (3%) were technically inadequate for generating CTA because of respiratory motion artifact. The average times for postprocessing of VR and MIP images were 8.1 +/- 3.8 minutes and 5.0 +/- 0.7 minutes, respectively. Variations of hepatic arterial anatomy were present in 19 patients (32%) on conventional angiography. In 8 patients (13%), there was discrepancy in the variations of hepatic arterial anatomy between the two techniques: MIP was correct in 7 patients, and VR was correct in 1 patient. The dominant artery supplying segment IV was identified in 51 patients (85%) with MIP and in 39 patients (65%) with VR. There was no significant difference in conspicuity of the hepatic arteries using either the MIP or VR technique. CONCLUSION: In CTA techniques using multidetector-row CT, MIP is superior to VR for the hepatic arterial evaluation of potential LDLT donors in terms of depicting anatomic variations and postprocessing time.

Adolescent↗

Back pain in adolescents: assessment with integrated 18F-fluoride positron-emission tomography-computed tomography.

The aim of the present study was to assess the ability of a novel bone imaging technique to diagnose accurately the cause for back pain as an isolated and presenting complaint in adolescents. An integrated 18F-fluoride positron-emission tomography-computed tomography (PET-CT) study was performed at the same setting without changing the patients' position, followed by generation of fused images of functional and anatomical data. Fifteen subjects were included in the study. The interpretation of PET-CT fused images was based on increased 18F-fluoride uptake and the corresponding CT-located abnormality. Ten patients had positive findings that included 4 cases of spondylolysis (3 of them active), 3 frank fractures (2 of the transverse process and 1 of the facet), 2 osteoid osteomas, 1 osteitis pubis, 1 sacroiliitis, and 2 herniated disks. Three patients presented 2 coexisting pathologies. Treatment was tailored based on final diagnosis. In 5 patients, in whom no abnormality was identified, the back pain resolved spontaneously. The 18F-fluoride PET-CT can detect spinal lesions with high diagnostic accuracy in adolescents with back pain. Considering the associated costs and radiation exposure, it should be used at present only in cases of long-standing and disabling back pain in which other imaging modalities were inconclusive.

Adolescent↗

Increase of accuracy in intraoperative navigation through high-resolution flat-panel volume computed tomography: experimental comparison with multislice computed tomography-based navigation.

HYPOTHESIS: High-resolution imaging, as provided by flat-panel-based volume computed tomography (fpVCT), could increase navigation accuracy and could therefore improve image-guided procedures or make novel navigated surgery concepts possible. BACKGROUND: Intraoperative navigation is an accepted tool in head and neck surgery. However, its use is limited in the lateral cranial base because of its low surgical accuracy. Surgical accuracy is substantially influenced by the resolution of the underlying data set. The fpVCT offers a resolution of nearly two times higher than multislice computed tomography (MSCT). Target registration error (TRE), as a measurement for surgical navigation accuracy, should decrease when navigation is based on fpVCT data sets. METHODS: An acrylic glass phantom with 37 fiducial points was scanned in a current MSCT and in an experimental fpVCT. Both data sets were imported in an optical navigation system. Five fiducial points were used for registration, and seven points were used for measuring TRE. The distance between the indicated pointer tip and the corresponding fiducial point in data set was measured as TRE. Registration and TRE measurement were repeated five times for each computed tomographic data set. Average TREs were calculated, and results were compared using t-test. RESULTS: The average TRE using MSCT (0.82 mm [standard deviation, 0.35 mm]) was significantly higher than that using fpVCT (0.46 mm [standard deviation, 0.22 mm]) (p < 0.01). CONCLUSION: Submillimeter surgical navigation accuracy is possible using high-resolution fpVCT. This could be highly beneficial in cranial base surgery navigation.

Humans↗

Diagnostic utility of positron emission tomography-computed tomography for predicting malignancy in cystic neck masses in adults.

OBJECTIVES: Combined positron emission tomography and computed tomography (PET-CT) is used for the diagnostic evaluation and staging of squamous cell carcinoma of the head and neck (SCCHN). By superimposing anatomic localization of CT with the physiologic data of PET, occult primary and metastatic neoplasms might be identified. Because the diagnostic algorithm for cystic neck masses in adults often overlaps with the work-up of cancer of unknown primary site, we evaluated the utility of PET-CT scans to identify the presence of malignancy and the location of primary tumor. STUDY DESIGN: Single-institution retrospective case review series. METHODS: We reviewed the PET-CT imaging of cystic neck masses occurring in five patients over 40 years of age with significant risk factors for SCCHN and correlated this information with histopathology. RESULTS: In each patient in our series, the PET portion of a combined PET-CT was misleading, whereas the CT examination was more suggestive of the correct pathology. Ultimately, clinical judgment and endoscopic evaluation, guided by CT findings, were most valuable for distinguishing malignant versus benign processes and identifying the primary tumor sites. CONCLUSIONS: PET-CT may not be a reliable modality for identifying malignancy in adults with suspicious cystic neck masses. A thorough clinical evaluation by an experienced head and neck surgeon, in conjunction with contrast-enhanced CT, may be sufficient to facilitate the optimal management of such patients.

Adult↗

Usefulness of a saline flush for intravenous 3-dimensional computed tomography portography using multidetector-row helical computed tomography.

PURPOSE: To evaluate the clinical usefulness of a saline flush technique in improving the imaging quality of 3-dimensional computed tomography portography (3D-CTP). METHODS: To evaluate liver metastases, 58 patients were divided into 2 groups undergoing 3D-CTP with or without a saline flush. The computed tomography (CT) values of the right portal vein (RPV), left portal vein (LPV), main portal vein (MPV), and right hepatic parenchyma (RHP) were assessed. Maximum intensity projection (MIP) 3D-CTP images were evaluated by vessel visualization. RESULTS: Higher mean CT attenuation values in the RPV, LPV, MPV, and RPV-RHP were observed in the saline flush group and were statistically significant (P = 0.04, P = 0.03, P = 0.01, and P = 0.04, respectively). The difference in imaging quality between 2 groups was statistically significant (P = 0.04). In segment VIII, the ability to depict the segmental branches was significantly higher when the saline flush technique was used (P = 0.03). CONCLUSIONS: The saline flush technique increases the CT attenuation values of the portal vein and the difference in values between the portal vein and the tissue around it and improves the MIP imaging quality of 3D-CTP.

Contrast Media↗

The identification of mandible fractures by helical computed tomography and panorex tomography.

The introduction of computed tomography (CT) in 1972 revolutionized the radiographic evaluation of patients who have experienced trauma. However, panoramic tomography (PT) continued to be superior in sensitivity to CT in the identification of mandible fractures and has been considered the gold standard for the past 3 decades. In 1989, a faster, higher-resolution spiral or helical CT (HCT) became widely available, and its efficacy in multiplanar evaluation and diagnosis of fractures of the upper two thirds of the face has been well established. The sensitivity of this new-generation HCT in comparison to PT in the detection of mandible fractures has not been determined. The purpose of this study was to compare the sensitivity, physician interpretation error, and interphysician agreement of HCT and PT in the identification of mandible fractures. The number and anatomical location of mandible fractures identified by HCT and PT was not significantly different. However, the number and location of 96% of fractures identified by HCT was agreed on by neuroradiologists compared with only 91% of fractures identified by PT. Furthermore, the interphysician agreement when no fracture was identified was 96% by HCT versus only 81% by PT. In conclusion, HCT has enhanced imaging quality, equivalent sensitivity in identification of fractures, decreased interpretation error, and greater interphysician agreement in the identification of mandible fractures. HCT has surpassed PT as the current gold standard for the radiographic evaluation and diagnosis of mandible fractures.

Humans↗

Integrated 18F-fluorodeoxyglucose positron emission tomography and computerized tomography in endodermal sinus tumor.

Application of an in-line positron emission tomography and computerized tomography (PET-CT) in endodermal sinus tumor (EST) is described in this study. CASE 1: A young female with massive ascites postovarian mass resection had elevated alpha-fetoprotein (AFP) serum levels. Following a positive PET-CT study with increased (18)F-fluorodeoxyglucose (FDG) uptake, a CT-guided core biopsy of a peritoneal mass was performed. EST was diagnosed histologically. The patient was disease free after chemotherapy. Follow-up PET-CT was negative in keeping with no viable tumor tissue. CASE 2: A large pelvic mass diagnosed histologically as primarily EST was removed in a teenage patient with elevated AFP levels. PET-CT showed diffuse abdominal spread of FDG uptake, suggesting extensive peritoneal seeding. The patient was disease free after chemotherapy. Follow-up PET-CT was negative. EST is an FDG-avid tumor. PET-CT delineated the prechemotherapy tumor extent adequately ruled out the presence of residual tumor after a successful treatment.

Adolescent↗

Measuring red blood cell flow dynamics in a glass capillary using Doppler optical coherence tomography and Doppler amplitude optical coherence tomography.

Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler amplitude optical coherence tomography (DAOCT), a novel extension of DOCT. Velocity profiles and concentration distributions of normal and rigidified in vitro red blood cell suspensions are shown to vary as functions of mean flow velocity, cell concentration, and cell rigidity. Deviation from the parabolic velocity profile expected for Pouseille flow is observed for both rigid and normal cells at low flow rates. Axial red cell migration both toward and away from the tube axis is observed for both rigid and normal cells as a function of flow velocity. Good agreement is found between our measurements, and theoretical expectations.

Blood Flow Velocity↗

Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction algorithms: ART, SIRT, Landweber iteration (LWB), the generalized Landweber iteration (GLWB), the steepest descent method (STP), as well as iterative filtered backprojection (IFBP) reconstruction algorithms: Chang's method, Walters' method, and a modified iterative MAP. The framework provides an effective tool to systematically study conventional iterative algebraic algorithms and IFBP algorithms. Based on this framework, conventional iterative algebraic algorithms and IFBP algorithms are generalized. It is shown from the algebraic point of view that IFBP algorithms are not only excellent methods for correction of attenuation (either uniform or nonuniform) but are also good general iterative reconstruction algorithms (they can be applied to either attenuated or attenuation-free projections and converge very fast). The convergence behavior of iterative algebraic algorithms is discussed and insight is drawn into the fast convergence property of IFBP algorithms. A simulated PET system is used to evaluate IFBP algorithms and LWB in comparison with the maximum likelihood estimation via expectation maximization algorithm (MLE-EM) and the filtered backprojection (FBP) algorithm. The simulation results indicate that for both attenuation-free projection and attenuated projection cases IFBP algorithms have a significant computational advantage over LWB and MLE-EM, and have performance advantages over FBP in terms of contrast recovery and/or noise-to-signal ratios (NSRs) in regions of interest.

Algorithms↗

Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography.

BACKGROUND: Electron beam computed tomography (EBCT) and multislice computed tomography (MSCT) are both suitable for non-invasive identification of coronary stenoses. OBJECTIVE: To compare intravenous coronary EBCT angiography (EBCTA) and MSCT angiography (MSCTA) with regard to image quality and diagnostic accuracy. METHODS: EBCTA was done using an Imatron C-150 XP scanner in 101 patients following a standard protocol (slice thickness 3 mm, overlap 1 mm, acquisition time 100 ms, prospective ECG trigger). For MSCTA in a different set of 91 patients (using a Siemens Somatom Plus4VZ scanner), the whole volume of the heart was covered in a spiral technique by four simultaneous detector rows. Using retrospective ECG gating, the raw data were reconstructed in (mean (SD)) 215 (12) axial slices acquired in diastole (slice thickness 1.25 mm, overlap 0.5 mm, acquisition time 250 ms/slice). RESULTS: With EBCTA, 76% of predetermined coronary segments in a nine segment model could be assessed with diagnostic image quality, and with MSCTA, 82%. A low contrast to noise ratio with EBCTA, and the presence of motion artefacts with MSCTA were the main reasons for inadequate image quality. Using conventional angiography as the gold standard, 77% of stenoses of > 50% could be identified correctly with EBCTA and 82% with MSCTA. Significant stenoses were correctly ruled out in 93% of segments with EBCTA, and in 96% of segments with MSCTA. The average contrast to noise ratio was higher with MSCTA than with EBCTA (9.4 v 6.5; p < 0.001). CONCLUSIONS: EBCTA and MSCTA show similarly high levels of accuracy for determining and ruling out significant coronary artery stenoses. MSCTA is capable of providing good image quality in more coronary segments than EBCTA because of its better contrast to noise ratio and higher spatial resolution. Motion artefacts seen at heart rates of > 75 beats/min and a higher radiation exposure are the main limitations of MSCTA.

Coronary Angiography↗

Angio-computed tomography and dynamic computed tomography in staging of renal cell carcinoma.

Dynamic computed tomography and angio-tomography combine criteria generated by CT with those of angiography and are advocated by the author to improve staging of renal cell carcinoma. Dynamic CT was performed in 29 patients and angio-CT in 12 patients in this group. Rapid acquisition of data permits generation of a CT section in intervals of 1 to 6 seconds, which in turn reflects arterial, capillary, and venous transit of contrast medium through tissues. The propensity for dense enhancement of renal cell carcinoma makes possible positive identification of tumor elements. This feature proved accurate for the assessment of local extension of renal neoplasms in all 29 patients, involvement of the renal vein by tumor in 9/10, involvement of the inferior vena cava by tumor in 6/6, and involvement of regional nodes by tumor in 6/8.

Adenocarcinoma↗

Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography.

BACKGROUND: The purpose of the present study was to assess the diagnostic performance of attenuation-corrected (AC) stress 99mTc-sestamibi cardiac single-photon emission computed tomography (SPECT) for the identification of coronary heart disease (CHD). METHODS AND RESULTS: With a triple-detector SPECT system with a 241Am transmission line source, simultaneous transmission/emission tomography (TCT/ECT) was performed on 60 patients with angiographic coronary disease and 59 patients with < or = 5% likelihood of CHD. Iteratively reconstructed AC stress 99mTc-sestamibi perfusion images were compared with uncorrected (NC) filtered-backprojection images. Normal database polar maps were constructed from AC and NC images for quantitative analyses. From the low-likelihood patients, the visual and quantitative normalcy rates increased from 0.88 and 0.76 for NC to 0.98 and 0.95 for AC (P < .05). For the detection of CHD, the receiver operating characteristic curves for the AC images demonstrated improved discrimination capacity (P < .05), and sensitivity/specificity values increased from 0.78/0.46 (NC) to 0.84/0.82 (AC) with visual analysis and from 0.84/0.46 (NC) to 0.88/0.82 (AC) with quantitative analysis. For localization of stenosed vessels, visual and quantitative sensitivity values were 0.51 and 0.63 for NC and 0.64 and 0.78 for AC images (P < .05), respectively. CONCLUSIONS: TCT/ECT myocardial perfusion imaging significantly improves the diagnostic accuracy of cardiac SPECT for the detection and localization of CHD. Clinical use of TCT/ECT imaging deserves serious consideration.

Coronary Angiography↗

Failure of follow-up gallium single-photon emission computed tomography and fluorine-18-fluorodeoxyglucose positron emission tomography to predict the deterioration of a patient with cardiac sarcoidosis.

Although gallium-67-citrate (67Ga) scanning and single-photon emission computed tomography (SPECT) are useful in the assessment of disease activity in cardiac sarcoidosis, a patient with cardiac sarcoidosis in whom SPECT imaging with 67Ga failed to predict the deterioration in the clinical course is presented. A 53-year-old woman diagnosed with cardiac sarcidosis had 67Ga scanning and 67Ga SPECT, both of which showed abnormal high uptake. After treatment with corticosteroid, there was an apparent improvement in the 67Ga SPECT findings, and the dose of the corticosteroid was reduced. Subsequently, the disease activity of the cardiac sarcoidosis was thought to be well controlled, because abnormal uptake was not found on repeat 67Ga SPECT. However, 4 years after initial diagnosis, thinning at the basal ventricular septal wall and complete atrioventricular block were noted. Despite repeating the evaluation with 67Ga SPECT and additional fluorine-18-fluorodeoxyglucose positron emission tomography (18FDG PET) after discovering this progression, neither of these examinations showed any abnormality. Unfortunately, in this patient, the disease activity of cardiac sarcoidosis was underestimated by the diagnostic imaging modalities.