Measurement of mucosal capillary hemoglobin oxygen saturation in the colon by reflectance spectrophotometry.

BACKGROUND: Advances in optical and computer technology have enabled the development of a device that uses white-light reflectance spectrophotometry to measure capillary hemoglobin saturation in intestinal mucosa during colonoscopy. METHODS: Studies were performed with the colon oximeter in anesthetized animals and patients undergoing colonoscopy. RESULTS: Mean (SD) mucosal hemoglobin saturation in the normal colon was 72% (3.5%). In an animal model, ischemia induced by arterial ligation and hypoxemia via hypoxic ventilation each resulted in a decrease of over 40% in the mucosal saturation. In patients with colon polyps, ischemia induced by epinephrine injection, stalk ligation with a loop, or clipping of the polyp stalk each resulted in a decrease of over 40% in the mucosal saturation (p < 0.02). In contrast, saline solution injection did not decrease the mucosal saturation. CONCLUSIONS: A novel device for measuring capillary hemoglobin saturation in intestinal mucosa during colonoscopy is capable of providing reproducible measurements in normal patients and clearly detects dramatic decreases in saturation with ischemic and hypoxic insults.

Aged↗

Oxidation process of bovine heart ubiquinol-cytochrome c reductase as studied by stopped-flow rapid-scan spectrophotometry and simulations based on the mechanistic Q cycle model.

Stopped-flow rapid-scan spectrophotometry was employed to study complicated oxidation processes of ubiquinol-cytochrome c reductase (QCR) that was purified from bovine heart mitochondria and maximally contained 0.36 mol of ubiquinone-10/mol of heme c1. When fully reduced QCR was allowed to react with dioxygen in the presence of cytochrome c plus cytochrome c oxidase, the oxidation of b-type hemes accompanied an initial lag, apparently low potential heme bL was oxidized first, followed by high potential heme bH. Antimycin A inhibited the oxidation of both b-type hemes. The oxidation of heme c1 was triphasic and became biphasic in the presence of antimycin A. On the other hand, starting from partially reduced QCR that was poised at a higher redox potential with succinate and succinate-cytochrome c reductase, the b-type hemes were oxidized immediately without a lag. When the ubiquinone content in QCR was as low as 0.1 mol/mol heme c1 the oxidation of the b-type hemes was almost suppressed. As the Q-deficient QCR was supplemented with ubiquinol-2, the rapid oxidation of b-type hemes was restored to some extent. These results indicate that a limited amount of ubiquinone-10 found in purified preparations of QCR is obligatory for electron transfer from the b-type hemes to iron-sulfur protein (ISP) and heme c1. The characteristic oxidation profiles of heme bL, heme bH, and heme c1 were simulated successfully based on a mechanistic Q cycle model. According to the simulations the two-electron oxidation of ubiquinol-10 via the ISP and heme c1 pathway, which is more favorable thermodynamically than the bifurcation of electron flow into both ISP and heme bL, does really occur as long as heme bL is in the reduced state and provides ubiquinone-10 at center i. Mechanistically this process takes time, thus explaining the initial lag in the oxidation of the b-type hemes. With the partially reduced QCR, inherent ubisemiquinone at center i immediately oxidizes reduced heme bH thus eliminating the lag. The mechanistic Q cycle model consists of 56 reaction species, which are interconnected by the reaction paths specified with microscopic rate constants. The simulations further indicate that the rate constants for electron transfer between the redox centers can be from 10(5) to 10(3) s-1 and are rarely rate-limiting. On the other hand, a shuttle of ubiquinone or ubiquinol between center o and center i and the oxidation of heme c1 can be rate-limiting. The interplay of the microscopic rate constants determines the actual reaction pathway that is shown schematically by the "reaction map." Most significantly, the simulations support the consecutive oxidation of ubiquinol in center o as long as both heme bL and heme bH are in the reduced state. Only when heme bL is oxidized and ISP is reduced can SQo donate an electron to heme bL. Thus, we propose that a kinetic control mechanism, or "a kinetic switch," is significant for the bifurcation of electron flow.

Animals↗

Determination of beryllium, cadmium, and tellurium in animal tissues using electronically excited oxygen and atomic absorption spectrophotometry.

A method using electronically excited oxygen for destruction of organic matter and atomic absorption spectrophotometry for the determination of beryllium, cadmium and tellurium in animal tissues is presented. Samples are solubilized in dilute aqua regia after being subjected to an oxygen plasma, low-temperature (less than 190 degrees C) ashing system for 20 to 30 hours. Recovery data from spiked NBS freeze-dried bovine liver indicate a quantitative determination for the three elements. Limits of detection in micrograms of element per milliliter of solubilized sample solution are: beryllium, 0.05; cadmium 0.05; and tellurium, 0.50. Beryllium, cadmium, and tellurium assay data are reported for the fresh tissues of albino rats exposed to inorganic chemicals by oral or intraperitoneal routes. The tissues analyzed include: adrenal, brain, femur, heart, kidney, liver, lung, mesenteric lymph node, pancreas, prostate, seminal vesicle, spleen, testicle, and tracheal-bronchial lymph node.

Adrenal Glands↗

Light element abundance in brain nuclei using energy dispersive x-ray analysis and atomic absorption spectrophotometry.

A comparative study of light element (congruent to ion) abundance in isolated brain nuclei, using atomic absorption (AA) spectrophotometry and the scanning electron microscope mode of energy dispersive x-ray analysis (EDXA), demonstrated similar statistical trends in the abundance of Na, Mg, and K at 0 time and at 4 min of total brain ischemia. The obtained correlation strengthens the validity of the comparison of quantitative and semi-quantitative procedures. The EDXA technique represents a new approach to the study of ionic shifts in brain ischemia that may prove useful in other areas of brain research as well.

Animals↗

Determination of selenium in tissues, serum, and blood of wild rodents by graphite furnace atomic absorption spectrophotometry.

Selenium (Se) levels were determined in liver, kidney, blood, and serum of wild rodents using graphite furnace atomic absorption spectrophotometry. A simple wet digestion technique was used to prepare samples for analysis. Nickel nitrate was used to suppress volatilization of Se during the char stage. Compared to existing techniques this greatly reduces the effort and time required for sample preparation and allows use of the graphite furnace atomic absorption technique for Se determination.

Animals↗

Higher-order derivative spectrophotometry in environmental analytical chemistry.

Higher-order derivative spectrophotometry (HODS) is a very good tool for the fine-resolution of spectra and other electric signals. This method allows one to separate superimposed curves for quantitative measuring. In the following, examples are given for the estimation of pollutants in water, air and soils which demonstrate the advantages of the HODS. This also applies to difficult problems in environmental analytical chemistry. In detail, we discuss the simultaneous estimation of aniline and phenol in waste water, the quantitative determination of PCP in polluted drinking water, phenol in turbid samples, the identification of aromatic amides and phenols in air after absorption in solvents and, last but not least, the study of Ni2+ adsorbed on bentonite powder.

Air Pollutants↗

Zeeman effect electrothermal atomic absorption spectrophotometry with matrix modification for the determination of arsenic in urine.

Arsenic was determined in urine by electrothermal atomic absorption spectrophotometry using Zeeman Effect background correction and after matrix modification with 5% nickel nitrate. Mean recovery of urine samples spiked with 100 micrograms . L-1 dimethylarsinic acid was 97.9 micrograms . L-1. Within-run CV was 2.4%, between-run CV was 7.3% and the detection limit was determined to be 10.0 micrograms . L-1. The method can be used for the rapid screening of urine samples for elevated arsenic levels.

Arsenic↗

Determination of organic matter in grinding sludges by UV spectrophotometry.

The aim of this paper is to determinate the total organic matter content of grinding sludges by a simple and fast methodology based on a solvent extraction followed by a UV spectrophotometry analysis. Several UV spectra exploitation methods are used. The multiwavelength deconvolution procedure provides quantitative results in good accordance with those obtained by a gravimetric method, possibly underestimated and enables a separate quantification of the cuttings fluids and the lubricants in the sludges. The normalisation procedure and the search of isobestic points provide important qualitative information on the evolution and on the composition of the oils used in metal processing. Therefore, this study is a first step for the development of a tool for the characterisation of organic matter in grinding sludges.

Hydrocarbons↗

Study of the impact of mechanical treatments on wastewater solids by UV spectrophotometry.

The aim of this paper is, from the perspective of improvement of Total Suspended Solids (TSS) measurement by UV spectrophotometry, to study the influence of two pretreatments on the UV responses of urban wastewater (sonication and mechanical grinding). The study of optical properties evolution the different phenomena involved and show mechanical grinding as a potential pre-treatment is prosed. Mechanical grinding is applied to samples characterised by different TSS concentration and particle size distributions in order to test its feasability. Results show the limit of the pretreatment and the difficulty of exploiting the UV response of urban wastewater for TSS characterization and estimation.

Mechanics↗

Normal chromium levels in urine and blood of Japanese subjects determined by direct flameless atomic absorption spectrophotometry, and valency of chromium in urine after exposure to hexavalent chromium.

Two hundred and thirty one urine and 20 blood samples of Japanese subjects from 4 geographic areas without known chromium pollution were assayed for chromium by direct flameless atomic absorption spectrophotometry. Normal chromium level in urine of Japanese subjects was 0.41 microg/L on an average. Urine level was less than 0.8 microg/L for all age and sex groups. Chromium levels in 2 hour urines did not correlate with those in 24 hours urine. Blood level of chromium was 2.9 ng/mL. A rabbit given an oral administration of 100 mg hexavalent chromium excreted 8.2 mg in 15 days after administration. No hexavalent chromium could be detected in urine. Ninety percent of the urinary excretion occurred within 2 days of administration.

Adolescent↗

Using difference spectrophotometry to study the influence of different ions and buffer systems on drug protein binding.

Difference spectrophotometry was used to investigate the effect of different ions and buffer systems on the binding of the anti-inflammatory drug tenoxicam to human serum albumin (HSA). Chloride anions, as well as sodium cations, were found to decrease the binding affinity. The effect of chloride ions was greater on the primary binding constant K1, while sodium ions had a greater effect on the secondary binding constant K2. The number of binding sites n1 and n2 were not affected except at 0.12% HSA, for which the presence of sodium ions halved n2. Potassium ions significantly increased K1. The presence of potassium instead of sodium ions increased binding affinity at lower HSA concentrations. The number of binding sites n1 and n2 were fewer in presence of potassium than in the presence of sodium ions except at 0.12% HSA. The divalent calcium and magnesium cations increased the binding affinity of HSA to tenoxicam, with a greater effect on K1. The effect of magnesium ions on K1 occurred when the MgCl2 concentration was increased to 3 and 9 mM, with the former seeming to be a critical concentration. The number of primary binding sites n1 was not affected by calcium ions, but was halved by 1 mM MgCl2. Both calcium and magnesium cations decreased n2, which was halved when the concentration of either cation was increased to 9 mM. The effect of buffer systems on tenoxicam binding to HSA was dependent on HSA concentration. The value of K1 was higher in Sorensen's phosphate buffer than in Tris [tris(hydroxymethyl) aminomethane HCl] buffer when the HSA concentration was 0.04% and 0.16%, while the reverse was observed at 0.08% and 0.12% HSA. The other binding parameters (K2, n1, and n2) were higher in Sorensen's phosphate than in Tris buffer. However; at certain HSA concentrations, the values of such parameters were comparable in both buffer systems.

Anti-Inflammatory Agents, Non-Steroidal↗

Analysis of some aromatic amines by means of derivative spectrophotometry.

Derivative spectrophotometry (DS) was applied for the determination of selected aromatic amines in two-compound mixtures. Following pairs were analysed: o- and m-toluidine, o- and p-toluidine, m- and p-toluidine; o- and m-phenylenediamine (PDA), o- and p-PDA, m- and p-PDA; p,p'-diaminodiphenylmethane (DADPMe) and p-toluidine. The developed method of DS was used as a complementary technique to HPLC with DAD detector as it allows the determination of compounds, which give a common peak in a chromatographic system.

Amino Acids, Aromatic↗

An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometry.

Factors affecting the accuracy of the in vivo measurement of cutaneous pigments and blood oxygenation by reflectance spectrophotometry have been examined. It was found that stray light, the amounts of haemoglobin and melanin, and the level of blood oxygenation all contributed to the measured reflectance and had to be taken into account when calculating quantitative indices of skin pigments. Measurements on isolated sheets of epidermis demonstrated that over 50% of normally incident radiation is transmitted in a forward direction within 17 degrees of the incident direction and approximately 20% is backscattered between 90 degrees and 180 degrees out of the sample, approximately 6.0% of it by specular reflection at the surface. The effective optical pathlength in suspensions of whole red cells was found to be 7% greater than in simple solutions containing the same concentration of haemoglobin.

Hemoglobins↗

The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid. It acts as container for a liquid solution with Intralipid, 60 micromol l(-1) haemoglobin and yeast. The solution was oxygenated using oxygen and then deoxygenated by the yeast. From the instrumental (Critikon 2020) algorithm, we found that with increasing scattering (0.5%, 1%, 1.5% and 2% Intralipid concentration) the reading was increasingly offset from the expected value of 0 micromol l(-1) by 55.7, 68.6, 76.5 and 80.4 micromol l(-1) (oxyhaemoglobin) and 16.0, 24.4, 29.6 and 31.7 micromol l(-1) (deoxyhaemoglobin). This reduced the range of the oxygen saturation reading from the expected 100% to 31.5, 21.1, 14.3 and 11.5%. Haemoglobin concentration changes were increasingly underestimated by a factor of two to four. For a second algorithm based on the diffusion approximation the offsets were smaller: oxyhaemoglobin 11.4, 17.8, 22.5 and 25.1 micromol l(-1) and deoxyhaemoglobin 1.3, 3.4, 5.2 and 6.0 micromol l(-1). The range of the oxygen saturation reading was higher: 41.3, 29.2, 23.4 and 16.6%. Concentration changes were underestimated by a factor of six to ten. This study demonstrates the need to develop algorithms which take into consideration anatomical structures.

Algorithms↗

A combination of microendoscopy and spectrophotometry allowing real-time analysis of microcirculatory parameters during in vivo observations.

A combination of microendoscopy (which is a modification of endoscopy with fine rigid endoscopes) and spectrophotometry (which analyses on line the remission spectra from the endoscopic picture) is presented. This setup allows the endoscopic in vivo observation of haemodynamics as well as simultaneous on line determination of intravascular haemoglobin oxygenation. Furthermore, the clearance of intravasally applied tracers can be analysed. Application, results and further evaluation of this new technique are demonstrated in the retinal vessels of the albino rabbit.

Animals↗

Electronic light microscopy combined with spectrophotometry allows real-time analysis of structures at the subcellular level.

A combination of microscopy (video-enhanced contrast microscopy) and spectrophotometry (which analyses online the spectra from the microscopic picture) is presented. This set-up allows the in vivo microscopic observation of cellular and subcellular structures as well as simultaneous online determination of cellular chromophores. To test our equipment we measured spectra of isolated red blood cells and NG 108-15 cells and correlated these spectra with the corresponding video-enhanced microscopic picture. By labelling specific cell organelles of astrocytes with in vivo fluorescent dyes, we visualized mitochondria and captured the corresponding spectra.

Animals↗

Tissue oxygen saturation measured by near infrared spectrophotometry correlates with arterial oxygen saturation during induced oxygenation changes in neonates.

The aim of this study was to compare quantitatively the changes in tissue oxygen saturation (TOS), determined by two algorithms (TOSc and TOSa) based on near-infrared spectrophotometry, to the changes in arterial oxygen saturation (SaO2) measured by pulse oximetry. TOSc is an algorithm derived by the manufacturer (Critikon) based on a modified Beer-Lambert law; TOSa, our own algorithm, uses the diffusion approximation of light transport for the semi-infinite boundary condition. Slow changes of more than 3% in SaO2 were carried out in 20 mechanically ventilated neonates by altering the inspired oxygen fraction. For each change the regression lines of TOSc versus SaO2, TOSa versus SaO2 and TOSc versus TOSa were calculatcd. For each infant the mcan slope, intercept and r2 of these lines were determined. In 18 preterm infants we obtained median 9.5 (range one to 13) measurements corresponding to a total of 166 measurements. The mean SaO2 was 91.6 (SD 2.3)%, TOSc was 64.7 (SD 7.2)% and TOSa was 71.4 (SD 11.0)%. Changes in TOSc and TOSa were strongly correlated to changes in SaO2 (r2 = 0.86 and r2 = 0.87). TOSc considerably but systematically underestimated the size of the change: delta TOSc = 0.49 delta SaO2. TOSa quantified changes reasonably correctly: delta TOSa = 0.90 delta SaO2. Changes in TOSc and TOSa were highly correlated (r2 = 0.98). These results are promising, but the large inter-individual variation requires further work.

Algorithms↗

Plasma hemoglobin determination by recording derivative spectrophotometry.

Recording derivative spectrophotometry (DS) is a technic for analyzing absorbance curves by measuring the derivative (slope) of those curves. The derivative is a mathematical function that enhances rapid changes of direction of a curve and suppresses slow changes. We are presenting a simple, rapid, and reproducible method for determining plasma hemoglobin concentration, even in the presence of bilirubin, myoglobin, or marked turbidity. No toxic reagents are used and, since the analysis is purely physicomathematic, the sample is not altered and can be used for additional tests.

Bilirubin↗