Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

[Computed radiography in X-ray examination of stomach: evaluation by phantom experiments and clinical studies].

The usefulness and clinical applicability of computed radiography (FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an originally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS radiography in X-ray examination of the stomach regarding both the detectability and visual conspicuity of the lesion. In view of the other advantages of FCR, it can safely replace conventional FS radiography in X-ray examination of the stomach.

Humans↗

[Digital image intensification radiography in endoscopic retrograde cholangiopancreatography].

The standard in ERCP is the use of the conventional radiography system. Digital radiography system are very seldom used in ERCP, and then mostly by digital luminescence radiography. In this study we report our experience with digital image amplification radiography (DIAR) in ERCP. We examined 53 patients of clinical routine aged from 21 to 90 years. During the ERCP we used the X-ray statues and the real-time exposures. At the end of an examination the image post-processing followed. Both conventional and digital image amplification radiography needed the same examination conditions. The special X-ray protection (special lead-shields) used at digital ERCP did not hinder the examination. The DIAR provided at least the same amount of information as conventional radiography. An advantage of DIAR is the possibility of image post-processing such as contrast change, zooming, etc., and the digital archiving and communication. The examination time was reduced by about 30% as compared conventional ERCP, resulting in a reduction of the X-ray exposure time for the patients. The disadvantages of DIAR can surely be compensated by a high ERCP-rate.

Adult↗

Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

The aim of this study was to compare the sensitivity and specificity of digital chest radiography alone with digital chest radiography combined with dual-energy chest radiography in the detection of small non-calcified pulmonary nodules. Standard and dual-energy radiographs were obtained with a flat-panel digital chest system. Four radiologists reviewed digital posteroanterior chest radiographs in random order either alone or in conjunction with dual-energy soft tissue and bone images. Twenty patients with a total of 59 pulmonary nodules (median 0.5 cm, range 0.3-2.5 cm) confirmed by computed tomography (HU < or =100) were included. A level of confidence for each diagnosis was documented using a rating scale of 1-5. Brunner and Langer's test was performed for statistical analysis. Subgroup analysis was performed for nodules greater than 1 cm, 1-0.5 cm, and <0.5 cm. For posteroanterior chest radiography, sensitivity was 33%, positive predictive value 83%, specificity 81%, and negative predictive value 30%. Review in conjunction with dual-energy images resulted in a sensitivity of 42%, positive predictive value 88%, specificity 85%, and negative predictive value 34%. The increase of nodule detection overall as well as for different size categories was significant (p<0.05). The increase of the confidence level rating was also significant (p<0.001). Dual energy added to standard posteroanterior chest radiography significantly improves the sensitivity, specificity, and confidence in detection of small non-calcified pulmonary nodules.

Humans↗

[Image quality and exposure dose in digital projection radiography].

PURPOSE: Comparison of the imaging capabilities of storage phosphor (computed) radiography and flat plate radiography with conventional film-screen radiography to find new strategies for quality and dose management, i. e., optimizing imaging quality and dose depending on the imaging method and clinical situation. MATERIALS AND METHODS: Images of a CDRAD-phantom, hand-phantom, abdomen-phantom and chest-phantom obtained with different exposure voltages (50 kV, 73 kV, 109 kV) and different speeds (200, 400, 800, 1600) were processed with various digital systems (flat plate detector: Digital Diagnost [Philips]; storage phosphors: ADC-70 [Agfa], ADC-Solo [Agfa], FCR XG 1 [Fuji]) and a conventional film-screen system (HT100G/ Ortho Regular [Agfa]). RESULTS: The evaluation of CDRAD images found the flat plate detector system to have the highest contrast detectability for all dose levels, followed by the FCR XG 1, ADC-Solo and ADC-70 systems. Comparison of the organ-phantom images found the flat plate detector system to be equal to film-screen radiography and especially to storage phosphor systems even for low exposure doses. CONCLUSIONS: Flat plate radiography systems demonstrate the highest potential for high image quality when reducing the exposure dose. Depending on the system generation, the storage phosphor systems also show an improved image quality, but the possibility of a dose reduction is limited in comparison with the flat plate detector system.

Hand↗

Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: comparison with storage phosphor radiography at different exposures by using a chest phantom.

PURPOSE: To compare the exposure dose requirements and performance of a portable indirect flat-panel detector for pediatric use in the depiction of catheters, simulated pulmonary nodules, and simulated interstitial lung disease with those of storage phosphor radiography. MATERIALS AND METHODS: Catheters and simulated nodules and subtle interstitial lung disease (miliary, reticular, linear, and ground-glass patterns) were superimposed over an anthropomorphic chest phantom. Images were obtained with different exposures corresponding to simulated speeds of 400 and 800 with a portable flat-panel detector and printed on hard copies. These images were compared with those from storage phosphor radiography at a simulated speed of 400, which is typically used in pediatric radiology. Four independent readers recorded 7200 observations per pattern (for a total of 600 statistically independent observations), and these observations were subjected to receiver operating characteristic (ROC) analysis. Differences were considered significant at a P value of .05. RESULTS: Catheters over obscured chest areas, nodules 10 mm or smaller and larger than 10 mm over lucent lung, nodules 10 mm or smaller over obscured chest areas, and miliary and linear patterns over lucent lung showed higher areas under the ROC curve (A(z)) with the flat-panel detector at 400 and 800 digital speed compared with storage phosphor radiography. A(z) values for reticular and ground-glass patterns with the flat-panel detector were equal to or less than those with storage phosphor radiography. These differences, however, were not statistically significant. CONCLUSION: In the detection of catheters, nodules, and almost all interstitial lung disease, A(z) values were higher with the portable flat-panel detector than with storage phosphor radiography at equivalent and reduced speeds. These results suggest that the portable flat-panel detector could be used with reduced exposure dose in pediatric patients.

Analysis of Variance↗

Ultrasonography of the metatarsophalangeal joints in rheumatoid arthritis: comparison with magnetic resonance imaging, conventional radiography, and clinical examination.

OBJECTIVE: To compare ultrasonography (US) with magnetic resonance imaging (MRI), conventional radiography, and clinical examination in the evaluation of bone destruction and signs of inflammation in the metatarsophalangeal (MTP) joints of patients with rheumatoid arthritis (RA). METHODS: Two hundred MTP joints of 40 patients with RA and 100 MTP joints of 20 healthy control subjects were assessed with B-mode US, contrast-enhanced MRI, conventional radiography, and clinical examination for signs of bone destruction and joint inflammation. RESULTS: With MRI considered the reference method, the sensitivity, specificity, and accuracy of US for the detection of bone erosions were 0.79, 0.97, and 0.96, respectively, while the corresponding values for radiography were 0.32, 0.98, and 0.93. The sensitivity, specificity, and accuracy of US for the detection of synovitis were 0.87, 0.74, and 0.79, while for clinical examination, the corresponding values were 0.43, 0.89, and 0.71. Erosive disease was identified in 26 patients by US, compared with 20 patients by MRI and 11 patients by radiography. Evaluation by US indicated signs of inflammation in 36 patients, while MRI and clinical examination revealed signs of inflammation in 31 patients and 20 patients, respectively. US and MRI volume-based gradings of synovitis showed intraclass correlation coefficients of 0.56-0.72 (P < 0.0001). The MRI and radiographic visualizations of US-detected bone changes were closely related to their size-based gradings on US. CONCLUSION: US enables detection and grading of destructive and inflammatory changes in the MTP joints of patients with RA. By comparison with MRI, US was found to be markedly more sensitive and accurate than clinical examination and conventional radiography. Considering the early and frequent involvement of the MTP joints, evaluation of these joints by US may be of major clinical importance in RA.

Adult↗

Routine daily chest radiography is not indicated for ventilated patients in a surgical ICU.

OBJECTIVE: To determine a) if clinical examination can accurately predict radiological change and b) if routine chest radiography is efficacious. DESIGN: All mechanically ventilated patients admitted to the Surgical Intensive Care Unit over a 4-week period were enrolled into the study. A physical examination was undertaken by two clinicians to predict significant (radiographic features which alter management) and insignificant (radiographic features which do not alter management) changes. The radiographs were then reviewed by a radiologist who noted any changes from previous radiographs. The clinical findings were then correlated with the radiographical findings. SETTING: The study was conducted in a 16-bedded Surgical Intensive Care Unit which admits approximately 800 patients per year. The majority of these patients require mechanical ventilation. PATIENTS AND PARTICIPANTS: All patients who required mechanical ventilation were included. Thirty-four patients were studied. The patients were young adults admitted primarily following trauma with a low incidence of pre-existing disease. INTERVENTIONS: There were no interventions in this study. MEASUREMENTS AND RESULTS: One hundred sixty-four radiographs were evaluated. Both examiners were efficient in predicting significant changes (sensitivity of 93 and 97%), but less efficient at predicting insignificant changes (sensitivity of 74 and 70%). Two significant radiographical changes were missed on clinical examination: one catheter malposition and one pneumothorax, representing a yield from radiography of 1%. A 52% reduction in the number of radiographs would have resulted if the need for radiography had been determined by clinical examination. CONCLUSIONS: Clinical examination can effectively predict the need for radiography. Routine chest radiography is, therefore, not indicated for ventilated patients in our Surgical Intensive Care Unit.

Adult↗

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans↗

Frequency of chest radiography and abdominal ultrasound in the Netherlands: 1999-2003.

Chest radiography and abdominal ultrasound are two widely used diagnostic imaging techniques in Western societies. However, little is known about the frequency of these examinations and its determinants. The aim of this descriptive study was to provide detailed information on the number of chest radiography and abdominal ultrasound examinations by age, gender, referring physician and ethnicity. We used data of approximately 3,000,000 sick fund insured persons of the Health Insurance Company Agis in The Netherlands from 1999 to 2003. We calculated annual numbers and corresponding 95% confidence intervals for different age, gender and ethnicity categories. The mean age of the population was 38+/-22 years and 46% were male. Chest radiographs were ordered in 130 per 1000 persons per year and abdominal ultrasound examinations in 39 per 1000 persons per year; these frequencies did not change noticeable over the five-year period. Chest radiography was performed more often in males (156 vs. 109 per 1,000 persons/year in females; p < 0.05) and abdominal ultrasound more often in females (43 vs. 34 per 1000 persons/year in males; p < 0.05). Frequencies were highest in persons aged 70-79 years. Compared to medical specialists, general practitioners more frequently referred younger patients and females, especially for abdominal ultrasound. Up to the age of 60 years the frequencies of both chest radiography and abdominal ultrasound were higher in Turks and Moroccans compared to other persons. In conclusion, this study showed marked differences in the frequencies of chest radiography and abdominal ultrasound according to age, gender and ethnicity in The Netherlands.

Abdomen↗

Chest radiography for the diagnosis of acute aortic syndrome.

PURPOSE: We sought to assess the diagnostic accuracy of routine chest radiography for the acute aortic syndrome (dissection, intramural hematoma, penetrating ulcer, or nondissecting aneurysm). METHODS: During a 6-year period, 216 patients (143 men, 73 women; mean [+/- SD] age, 58 +/- 17 years) underwent chest radiography for suspected acute aortic syndrome. Chest films were re-evaluated blindly for aortic disease, based on an overall impression using standard criteria such as widening of the aortic contour and mediastinal shadow. Findings were matched to tomographic images, anatomical inspection, or both, as the criterion standard; aortic disease was confirmed in 109 (50%) of the patients. RESULTS: Chest radiography had a sensitivity of 64% (70/109) and a specificity of 86% (92/107) for aortic disease. Sensitivity was 67% (38/57) for overt aortic dissection, 61% (22/36) for nondissecting aneurysm, and 63% (10/16) for intramural hemorrhage or penetrating ulcer. However, sensitivity was lower for pathology confined to the proximal aorta (47% [21/45]) than for disease involving distal aortic segments (77% [49/64]). A receiver operating characteristic curve analysis of aortic diameters failed to identify a threshold for the diagnosis of aortic disease. CONCLUSION: Chest radiography is of limited value for diagnosing the acute aortic syndrome, particularly for conditions confined to the ascending aorta. Since a definitive diagnosis is required in any patient with clinically suspected acute aortic syndrome, routine chest radiography should be replaced by tomographic aortic imaging.

Acute Disease↗

Prevalence of negative chest radiography results in the emergency department patient with decompensated heart failure.

STUDY OBJECTIVE: Although chest radiography is quick and inexpensive, previous research suggests that it is often misleading in emergency department (ED) patients with decompensated heart failure, resulting in misdiagnosis and inappropriate treatment. This study determines the rate of negative chest radiography results in patients found to have disease and the potential contribution of negative findings to a diagnosis discordant with heart failure by an emergency physician. METHODS: We used data from the Acute Decompensated Heart Failure National Registry (ADHERE), a registry of patients with a primary hospital discharge diagnosis of heart failure. We compared initial ED admitting diagnosis to the criterion standard of a hospital discharge diagnosis of heart failure and related these to radiographic findings of heart failure (interstitial edema, pulmonary edema, or vascular congestion, as determined by a staff radiologist) for patients first treated in the ED. The proportion of patients with a non-heart failure ED diagnosis and the diagnostic sensitivity of radiographic findings of heart failure are calculated. RESULTS: There were 85,376 patients with chest radiograph results and an ED admitting diagnosis. Overall, there were 15,937 patients with no signs of congestion on ED chest radiography, giving a negative rate of 18.7% (95% confidence interval [CI] 18.4% to 18.9%). The proportion of patients with an ED non-heart failure admitting diagnosis was higher in patients with a negative chest radiograph result (23.3%; 95% CI 22.6% to 23.9%) than in patients with a positive chest radiograph result (13.0%; 95% CI 12.7% to 13.2%). CONCLUSION: Approximately 1 of every 5 patients admitted from the ED with acute decompensated heart failure had no signs of congestion on chest radiography. Patients lacking signs of congestion on ED chest radiography were more likely to have an ED non-heart failure diagnosis than patients with signs of congestion. Clinicians should not rule out heart failure in patients with no radiographic signs of congestion.

Aged↗

Implementing evidence-based guidelines for radiography in acute low back pain: a pilot study in a chiropractic community.

OBJECTIVE: To evaluate the ability of a systematic educational intervention strategy to change the plain radiography ordering behavior of chiropractors toward evidence-based practice for patients with acute low back pain (LBP). DESIGN: A quasi-experimental method was used comparing outcomes before and after the intervention with those of a control community. SETTING: Two communities in southern Ontario. DATA SOURCE: Mailed survey data on the management of acute LBP. Outcome Measures Plain radiography use rates for acute LBP based on responses to mailed surveys. RESULTS: Following the intervention, there was a 42% reduction in the self-report need for plain radiography for uncomplicated acute LBP (P <.025) and a 50% reduction for patients with acute LBP < 1 month (P <.025) in the intervention community. There was no significant change in the self-report need for plain radiography in the control community (P >.05). CONCLUSIONS: The educational intervention strategy used in this study appeared to have an effect in reducing the perceived need for plain radiography in acute LBP.

Adult↗

Domiciliary radiography: an important service?

General practitioners' (GP) perceptions, comparative costs and potential influence on patient management of a domiciliary radiography service were reviewed. A postal questionnaire was sent to 159 local GPs, 130 of whom responded. Seventy-one per cent of respondents had requested domiciliary radiography in the previous year and 79% felt loss of the service could potentially be detrimental. Although 98% recognized that a chest X-ray was a suitable domiciliary radiography examination, 6% thought that a barium swallow could be adequately carried out with domiciliary equipment. Forty-nine per cent perceived a need for a domiciliary ultrasound service. Sixty-three per cent believed that domiciliary radiography was cheaper than return ambulance transport with departmental examination, although estimates showed a domiciliary visit to cost 82 pounds versus 60 pounds for a departmental visit. A retrospective review of 50 consecutive domiciliary radiography examinations showed that elderly and immobile patients were imaged most frequently. Malignancy was diagnosed in 14%, infection in 26% and a fracture in 14%. Overall there was an anticipated management change in 50% of patients.

Adult↗

Long-term costs after gastroenterology consultation with endoscopy versus radiography in dyspepsia.

A randomized clinical trial assessed the medical costs during 6 months after the evaluation of dyspepsia by gastroenterology consultation with esophagogastroduodenoscopy versus barium radiography. Primary care physicians entered patients whose dyspepsia responded incompletely to empiric therapy or recurred. The consultation/endoscopy group (N = 32) was similar (p greater than 0.23) to the radiography group (N = 34) regarding age, gender, physician visits, and costs of all dyspepsia drugs and H2 blockers during 6 months before evaluation. Most patients had non-ulcer dyspepsia. Costs during the succeeding 6 months (consultation/endoscopy versus radiography groups) were physician visits ($33.1 +/- 14.5 vs. $114.2 +/- 23.3, p less than 0.005); radiologic procedures ($70.5 +/- 37.3 vs. $67.6 +/- 22.5, p greater than 0.30); all dyspepsia drugs ($30.4 +/- 10.0 vs. $100.1 +/- 36.8, p = 0.08); H2 blockers ($25.4 +/- 9.5 vs. $96.0 +/- 34.7, p = 0.06); and total cost ($134.0 +/- 43.8 vs. $435.3 +/- 93.9, p = 0.006). The higher total cost in the radiography group was partly due to the referral of 7 patients (21%) for gastroenterology consultation due to persistent dyspepsia, 6 of whom had endoscopy versus the performance of radiography in 0 of the 32 consultation/endoscopy patients (p less than 0.025). Dyspepsia self-ratings were similar.

Adult↗

Assessment of external root resorption using digital subtraction radiography.

Digital subtraction radiography was investigated for its capability to detect and quantify experimentally produced external root resorptive defects in teeth. Using a long source to object X-ray technique and E-speed film, serial radiographs of teeth with artificial lesions in a dry human skull (soft tissue simulated) were obtained. Receiver operating characteristic analysis was used to evaluate the diagnostic performance for each imaging system (conventional versus subtraction). To explore the quantitative assessment potential of digital subtraction radiography, images were produced after sequential demineralization by HCl. The acid solution was analyzed for calcium concentration by atomic absorption spectrophotometry. Three-dimensional histogram quantification for each subtracted image was performed. In overall performance for detecting experimentally produced external root resorption, digital subtraction radiography was found to be significantly superior to conventional radiography. In addition, digital subtraction radiography can provide quantification of experimentally produced external root resorptive defects.

Humans↗

Selective indications for thoracic and lumbar radiography in blunt trauma.

STUDY OBJECTIVE: To determine indications for thoracolumbar radiography. DESIGN: Case series with prospective data collection. SETTING: Level I trauma center. PARTICIPANTS: Blunt-trauma victims more than 12 years old who underwent routine thoracic and lumbar radiography according to institutional protocol. Patients were classified as group 1, not able to be evaluated clinically (Glasgow Coma Scale score of less than 13, intoxication, intubation, or cervical neurologic deficit); and group 2, able to be evaluated clinically. RESULTS: Twenty-four of 319 patients sustained 25 thoracic or lumbar fractures. Seven of 136 group 1 patients and 17 of 183 group 2 patients had fractures. Eight of 17 patients with pain and 9 of 17 with tenderness had fractures (P = .001). No group 2 patients without pain, tenderness, thoracic or lumbar neuro-deficit, or major distracting injury, including cervical fracture, had fractures. The negative predictive value of pain and tenderness was 95%. Five of 46 patients with spinal fractures at any level had multiple fractures. CONCLUSION: Blunt-trauma victims who cannot be evaluated clinically should undergo thoracolumbar radiography. Routine radiography may be unnecessary in asymptomatic patients who can be evaluated clinically and who do not have neurologic deficits or distracting injuries. Spinal fracture at any level mandates complete spinal radiography.

Adolescent↗

Information content and clarity of radiologists' reports for chest radiography.

RATIONALE AND OBJECTIVES: We systematically characterized the information provided by chest radiography reports on a nationally representative sample of 822 elderly patients hospitalized in 297 acute-care hospitals in five states who had an admission diagnosis of congestive heart failure, acute myocardial infarction, or pneumonia. METHODS: We studied the content of radiography reports, including mention of the type or adequacy of radiography; the presence or absence of a prior radiograph; comments about bones, the aorta, the mediastinum, and pleura and notation of the laterality of findings; and the presence of diagnosis. Two physicians reviewed each patient's report, and a third assigned the final rating when they disagreed. RESULTS: Our analysis found wide variation in content of chest radiography reports, extensive variation in terms used to identify the presence or absence of abnormal findings, and a large degree of uncertainty in what was found. CONCLUSION: With most hospitals introducing new information systems in response to technological advances and the need to generate more formal hospitalwide reports, the time is right to improve the quality of chest radiography reporting.

Aged↗

Quantitative digital subtraction radiography for the determination of small changes in bone thickness: an in vitro study.

OBJECTIVE: The objective of this study was to determine the ability of quantitative digital subtraction radiography to detect small changes in bone thickness adjacent to tooth roots. STUDY DESIGN: A series of cortical or cancellous bone slices with a 50 microm-stepwise increasing thickness were attached to 4 porcine mandible sections covering buccal and interproximal "defect" regions. Standardized radiographs were quantitatively evaluated for radiographic density changes with the use of digital subtraction radiography. Furthermore, all radiographs were conventionally evaluated by 10 clinicians. The Wilcoxon signed-rank test and the Mann-Whitney U test were used for statistical analysis (alpha = 0.05). RESULTS: A high linear correlation was found between the actual thickness of bone slices and radiographic density changes (cortical bone: r2 = 0.89 to 0.99; cancellous bone r2 = 0.61 to 0.86, p < or = 0.001). A certain increase in bone thickness caused a 3 times higher increase in radiographic density for cortical bone than for cancellous bone (p < or = 0.05). The detection limits of digital subtraction radiography were 200 microm for cortical and 500 microm for cancellous bone, whereas the detection limits of conventional radiography were 600 microm and 2850 microm, respectively. CONCLUSIONS: This in vitro study demonstrated a very high correlation between the objective, quantitative assessment of subtle changes in alveolar bone by digital subtraction radiography and the true changes in bone thickness.

Absorptiometry, Photon↗