Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyglactin 910”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Regenerative periodontal surgery with non-resorbable and biodegradable barriers: results after 24 months.

The aim of the present study was to compare the effects of guided tissue regeneration (GTR) with non-resorbable (ePTFE) and biodegradable barriers (Polyglactin 910). 23 patients provided 29 pairs of similar contralateral periodontal defects (12 pairs of interproximal intrabony lesions, 11 pairs of degree II and 6 pairs of degree III furcation defects). Each defect was randomly assigned to treatment with either non-resorbable (control [c]) or biodegradable (test [t]) devices. At baseline, 6, 12, 18, and 24 months after surgery, clinical measurements (PlI, GI, PPD, PAL-V, PAL-H) were performed. Standardized radiographs were obtained at baseline 12 and 24 months postsurgically. On the radiographs, the linear distances from the cemento-enamel junction (CEJ) to the alveolar crest (AC) and from the CEJ to bottom of the bony defect (BD) were measured using a computer-assisted analysing method (LMSRT). Both treatments revealed a significant (p<0.05) PPD reduction [all defects: -2.97 +/- 1.90 mm (t), -2.21 +/- 1.73 mm (c); intrabony defects: -4.00 +/- 1.96 mm (t), -3.00 +/- 1.87 mm (c); degree II furcations: -2.67 +/- 0.97 mm (t), -2.08 +/- 1.54 mm (c)], PAL-V gain [all defects: 2.02 +/- 1.83 mm (t), 1.18 mm +/- 1.50 (c); intrabony defects: 3.45 +/- 1.48 mm (t), 1.95 +/- 1.64 mm (c); degree II furcations: 1.33 +/- 0.94 mm (t), 0.92 +/- 1.47 mm (c)], PAL-H gain [degree II furcations: 2.22 +/- 0.94 mm (t), 1.86 +/- 0.60 mm (c)], and radiographic changes [CEJ-AC: -0.56 +/- 1.98 mm (t), -0.06 +/- 1.19 mm (c); CEJ-BD: 2.10 +/- 1.92 mm (t), 1.24 +/- 2.04 mm (c)] after 24 months. For degree III furcations, neither statistically significant PPD reduction nor PAL-V gain was observed. Similar clinical and radiographic results were found 12 and 24 months after surgical treatment using either non-resorbable or biodegradable barriers. More favorable results concerning PAL-V gain in interproximal intrabony defects could be observed with biodegradable barriers after 24 months than using nonresorbable membranes. Whereas interproximal intrabony lesions and degree II furcation defects responded favorably to GTR therapy, through-and-through furcations must be looked upon as a contraindication for this regenerative technique. Based on the results of the present study, the use of biodegradable barriers in GTR may be recommended and, thereby, a surgical re-entry to remove nonresorbable barriers can be avoided.

Adult↗

Skin closure at laparoscopy.

STUDY OBJECTIVE: To discern the best method of wound closure after laparoscopy based on patient acceptability of pain, complications, and cosmetic result. DESIGN: Randomized, prospective study. SETTING: A university-affiliated hospital. PATIENTS: Fifty-four women. Interventions. The women received interrupted 3-0 nylon sutures, subcuticular 3-0 polyglactin 910 sutures, or adhesive strips for skin closure. At the umbilical port site the rectus sheath was closed with a single 0 polyglactin suture and then one of the three materials for skin closure. The lateral ports were closed with a combination of these materials, allowing each patient to act as her own control. MEASUREMENTS AND MAIN RESULTS: Pain was significantly less in wounds closed by subcuticular technique than in those closed by either transcutaneous suture or adhesive strips. This was seen for the 5-mm, 10-mm, and umbilical port sites. There was no statistically significant difference in the rate of reported complications or patient satisfaction between subcuticular and transcutaneous wound sites. CONCLUSION: We believe these results support subcuticular methods of wound closure after laparoscopic procedures.

Dermatologic Surgical Procedures↗

Hydroxyapatite implant wrapping materials: analysis of fibrovascular ingrowth in an animal model.

PURPOSE: To compare the influence of seven currently available spherical orbital implant wraps on host fibrovascularization of a hydroxyapatite (HA) orbital implant. METHODS: Five groups of 3 (15 total) adult male New Zealand albino rabbits underwent enucleation with placement of a 12-mm HA implant wrapped in high-porosity expanded polytetrafluoroethylene (e-PTFE), processed bovine pericardium, or processed human pericardium, sclera, or fascia lata. Magnetic resonance imaging before and after the intravenous administration of gadolinium-diethylenetriamine pentaacetic acid (DTPA, 0.1 mol/kg) was performed immediately before exenteration. Five rabbits (one with each of the different implant wraps) were killed at 4, 8, and 12 weeks, and the operated socket was exenterated. Histopathologic sections of the implants were then compared with the results of our previous study using polyglactin 910 mesh and autologous sclera as HA orbital implant wraps. RESULTS: Complete fibrovascularization of all the implants occurred by 12 weeks; however, HA implants wrapped with sclera, polyglactin mesh, and e-PTFE appeared to undergo more rapid fibrovascularization than spheres wrapped with other materials. CONCLUSIONS: Although all of the implant wraps studied may be suitable substitutes for donor sclera, we prefer polyglactin mesh because it is readily available, inexpensive, and without risk of transmissible diseases.

Animals↗

[A study of the applicability of biological adhesives to the reinsertion of an external ocular muscle in rabbits--I experiment I--measurements of duration of procedures, and clinical and histopathologic studies].

PURPOSE: To measure the duration of the operation, the strength of tissue adhesion, and to perform a clinical and histopathological study of ocular reinsertion of superior rectus muscles of rabbits with four different tissue adhesives, as an alternative to the use of polyglactin suture in strabismus surgeries. METHODS: One hundred New Zealand rabbits were used for two experiments: I-A and I-B, with fifty rabbits for each experiment. These groups were further divided into five groups of ten rabbits (twenty eyes), which were subjected to the removal of the superior rectus muscle of both eyes, either with suture (control) or tissue adhesive: polyglactin 910, 6-0 suture and tissue adhesives made of fibrin, cyanoacrylate, albumin-glutaraldehyde and gelatine-resorcinol-formaldehyde-glutaraldehyde. The rabbits in experiment I-A were subjected to dynamometry for ten minutes following repositioning of the muscle. The rabbits in experiment I-B were subjected to clinical evaluation and to histopathologic evaluation. RESULTS: Better performance of the tissue adhesives in relation to the time taken to carry out the surgery was observed. None of the adhesives met the parameters used for strength, that is, in some cases the reinserted muscle did not resist to the application of forces up to 100 gf. The clinical and histopathologic evaluations showed that only the fibrin adhesive presented a better performance than the polyglactin suture while the other results were worse than those of the controls (suture). CONCLUSION: It was observed that the adhesives studied are not suitable for strabismus surgeries.

Animals↗

The efficacy of absorbable suture for microvascular anastomoses.

Although microvascular anastomoses are routinely performed with nonabsorbable sutures, a foreign body reaction can be stimulated that acts as a nidus for inflammation, infection, and possible thrombosis. Absorbable sutures should be able to diminish this reaction. There are sparse data describing the use of absorbable sutures for both arterial and venous anastomoses. This investigation compares standard microvascular anastomotic technique using nonabsorbable 10-0 sutures (nylon) with absorbable 10-0 sutures (polyglactin 910), using a previously reported tubed superficial epigastric flap model in rats. Patency rates and histologic responses are compared at intervals of 3 days and 1, 2, 8 and 12 weeks postoperatively. Arterial and venous patency rates were similar for both materials (overall nonabsorbable, 85.9%; overall absorbable, 84.4%). A somewhat increased inflammatory response was noted in the arterial absorbable group at 1 week and in both the venous and arterial nonabsorbable groups at 8 and 12 weeks postoperatively. The later finding most probably represents the continued presence of the nylon sutures. The incidence of intraluminal thrombosis was greater for nonabsorbable suture, occurring in two arterial and four venous anastomoses, compared with only one absorbable suture venous anastomosis. We conclude that nonabsorbable suture is as efficacious as standard absorbable material in both arterial and venous microanastomoses with the potential benefit of diminished foreign body reaction.

Absorption↗

Monofilament versus multifilament absorbable sutures for abdominal closure.

This study compares monofilament continuous absorbable sutures with multifilament interrupted absorbable sutures for abdominal closure. Before closure of an abdominal incision, 988 patients were randomized to receive either a monofilament polyglyconate (Maxon) or a multifilament polyglactin 910 (Vicryl) suture. At 1 year after operation, 684 patients (69 per cent) were examined for the presence of incisional hernia, sinus and other wound-healing problems; 179 (18 per cent) had died and 125 (13 per cent) did not attend for follow-up. Incisional hernia occurred in 8 per cent of patients receiving monofilament continuous sutures compared with 6 per cent of those having multifilament interrupted closure (P not significant). Wound dehiscence occurred in 1 per cent of both groups. The mean time for suturing was 7.1 min for monofilament continuous and 8.7 min for multifilament interrupted sutures (P < 0.001). It is concluded that closure of an abdominal incision can be effected by a monofilament continuous absorbable suture more quickly than by multifilament interrupted absorbable sutures without an increased risk of wound dehiscence or incisional hernia.

Abdominal Muscles↗

In vitro biocompatibility evaluation of poly(3-hydroxybutyrate-co-4-hydroxybutyrate) copolymer in fibroblast cells.

Among the various biomaterials available for tissue engineering and therapeutic applications, microbial polyhydroxyalkanoates offer the most diverse range of thermal and mechanical properties. In this study, the biocompatibility of poly(3-hydroxybutyrate-co-4-hydroxybutyrate) [P(3HB-co-4HB); containing 50 mol % of 4-hydroxybutyrate] copolymer produced by Delftia acidovorans was evaluated. The cytotoxicity, mode of cell death, and genotoxicity of P(3HB-co-4HB) extract against V79 and L929 fibroblast cells were assessed using MTT assay, acridine orange/propidium iodide staining, and alkaline comet assay, respectively. Our results demonstrate that P(3HB-co-4HB) treated on both cell lines were comparable with clinically-used Polyglactin 910, where more than 60% of viable cells were observed following 72-h treatment at 200 mg/mL. Further morphological investigation on the mode of cell death showed an increase in apoptotic cells in a time-dependent manner in both cell lines. On the other hand, P(3HB-co-4HB) at 200 mg/mL showed no genotoxic effects as determined by alkaline comet assay following 72-h treatment. In conclusion, our study indicated that P(3HB-co-4HB) compounds showed good biocompatibility in fibroblast cells suggesting that it has potential to be used for future medical applications.

Animals↗

The use of absorbable sutures in laser-assisted microvascular anastomoses.

The efficacy of the laser in performing microvascular anastomoses has been well established in the laboratory using a number of wavelengths. These studies have concluded that laser-assisted microvascular anastomoses are at least comparable to, if not superior to, ordinary suture techniques. The advantages have been the diminished foreign body reaction that occurs as a consequence of using only a few stay sutures to hold the vessels in approximation while the laser bonding is performed, as well as the rapidity of the surgery. We have already shown that absorbable sutures (polyglactin 910) are as efficacious as standard nonabsorbable sutures (nylon) in both arterial and venous microanastomoses. The current study was undertaken to see if the foreign body reaction could be diminished even further by the use of absorbable 10.0 sutures and compare these findings to laser-assisted microvascular anastomoses performed with nonabsorbable sutures. The carbon dioxide milliwatt laser was used to perform laser-assisted microvascular anastomoses in rat femoral arteries and veins. Patency rates and histological response were compared at intervals of 3 days and 1, 2, 4, 8, and 12 weeks postoperatively. Both arterial and venous patency rates were comparable (overall absorbable, 91.2%-52/57; overall nonabsorbable, 87.7%-50/57), as was the degree of inflammation and fibrosis. We conclude that absorbable sutures can be used for laser-assisted microvascular anastomoses and have the potential of allowing healing to occur without any foreign material within the surgical site.

Absorption↗

Primary closure of choledochotomy using CO2 laser: comparison with suture closure.

This study was designed to compare laser welding to suture closure of the common bile duct (CBD). A 12 mm linear choledochotomy was closed in 12 mongrel dogs using tissue welding low-energy CO2 laser. Tissue welding was accomplished at 5.0 w/cm2 for 120 sec. Twelve similar mongrel dogs (control) were treated with CBD closure using 5/0 Vicryl (polyglactin 910, Ethicon, Inc., Somerville, NJ) interrupted simple stitches. All animals were sacrificed at six weeks. Gross and histologic evaluation of the choledochotomy site were performed. There were no statistical differences in parameters of comparison in the two groups. These parameters were pre- and post-treatment measurements of liver function tests, stenosis, and dehiscence. However, it must be noted that there was a 33% (4/12) incidence of dehiscence and death in the CO2 laser welded choledochorrhaphy. This result, although not statistically significant, is clinically significant. We conclude that the tensile strength of CO2 laser welded CBDs must be optimized and that these results are preliminary and still unreliable to recommend for clinical adaptability.

Animals↗

Absorbable and nonabsorbable sutures in microsurgery: standardized comparable studies in rats.

In order to study the applicability and value of synthetic absorbable suture materials in microvascular surgery, 8-0 monofilament nonabsorbable polyamide sutures and 8-0 absorbable polyglycolic acid and polyglactin 910 sutures were used in end-to-end anastomoses of the aorta in rats, employing the same microsurgical model for all procedures. Comparable investigations of the anastomotic sites were carded out macroscopically and histologically at various intervals postoperatively. It was found that when placed under unphysiologic strain, microvascular anastomoses sutured with absorbable materials had less mechanical endurance than anastomoses stitched with nonabsorbable suture materials. It was also found, however, that this had no significance in vivo, inasmuch as no vascular ruptures or aneurysms appeared with either the absorbable or nonabsorbable sutures even after long-term observation. The nonabsorbable sutures were fully recognizable up to 150 days, microscopically showing clear evidence of granuloma formation. The absorbable sutures, on the other hand, could hardly be discerned after 50 days, and after 150 days the foreign body and scar reactions had almost completely disappeared. Absorbable suture materials lead to more rapid restitution of the vascular wall than nonabsorbable sutures and consequently appear to be superior.

Absorbable Implants↗

Laparoscopic assessment of ovarian healing following CO2 laser microsurgery: Vicryl vs. Surgilon.

A prospective multicenter study was undertaken by the Intraabdominal Laser Study Group to assess the type and extent of ovarian adhesions formed following incisional ovarian surgery performed as part of a fertility-promoting procedure with the aid of the carbon dioxide laser. Ovarian healing with subsequent adhesion formation was evaluated by early second-look laparoscopy. Two suture closing materials were used--Surgilon (siliconized braided nylon, David and Geck, Wayne, NJ) and Vicryl (polyglactin 910, Ethicon, Somerville, NJ). Sixty-five ovaries were evaluated in 37 patients with subsequent adhesions found in 37% (18/49) of the Surgilon-closed ovaries and in 94% (15/16) of the Vicryl-closed ovaries. The adhesions were filmy in 83% (15/18) of the Surgilon group and 47% (7/15) of the Vicryl group. Dense/vascular adhesions were found in 17% (3/18) of the Surgilon group and 53% (8/15) of the Vicryl group. The subsequent conception rates were 68% (17/25) in the Surgilon group and 33% (4/12) in the Vicryl group, although the small number of patients and multitude of infertility factors made pregnancy rate comparisons difficult. One of the authors noted lack of tensile strength in the Vicryl-closed ovaries within 12 weeks postlaser laparotomy, which led to incisional dehiscence during laparoscopic lysis of ovarian adhesions. From this preliminary study, it is concluded that additional data are needed to more fully resolve the debate on whether absorbable or nonabsorbable suture is preferred for ovarian infertility surgery.

Female↗

Effects of hypercholesterolemia on monokine-induced smooth muscle cell proliferation.

Macrophage/smooth muscle cell interactions play a role in atherogenesis and foreign body reactions to biomaterials. This study investigates the effect of a hypercholesterolemic diet on the ability of smooth muscle cells (SMCs) to respond to monokines which are produced in response to hypercholesterolemia, biomaterials or both. Peritoneal macrophages were harvested from rabbits fed either a normal (M phi NL) or a 2% cholesterol/6% peanut oil diet (M phi ATH) (plasma cholesterol 2840 vs 42.3 [p less than 0.005]). The macrophages were then cultured in the presence of either 1) polyglactin 910 (PG910), 2) Dacron, or 3) no biomaterial (control), and the media collected and pooled by week for the smooth muscle cell mitogenesis assays. Rabbit aortic smooth muscle cells were harvested and cultured from the same two groups of rabbits (SMCNL or SMCATH), quiesced in serum free media (48 h) followed by addition of the test media and 3H-TdR. The addition of either biomaterial to M phi NL-conditioned media increased 3H-TdR incorporation in both smooth muscle lines as compared to controls. PG910 resulted in significantly higher 3H-TdR incorporation than Dacron (weeks 3-5, p less than 0.005). The addition of either biomaterial to M phi ATH also increased 3H-TdR incorporation in both smooth muscle cell lines, however, the magnitude of the response was decreased as compared to the M phi NL-conditioned media in both cell lines (p less than 0.001 for either SMC line). In contrast to the M phi NL-conditioned media, the addition of Dacron to M phi ATH resulted in the highest level of 3H-TdR incorporation in both cell lines as compared to the media without biomaterial. The SMCNL had a higher response to both the monokines in conditioned media (2-fold) and to fetal bovine serum (3-fold) than the SMCATH (p less than 0.001). Although there is a generalized decrease in release of mitogens active on SMCs from M phi ATH, the M phi ATH exposed to Dacron release increased amounts of mitogenic factors, most active on the SMCATH cell line. A common mode of failure of small diameter Dacron grafts in man is pseudointimal hyperplasia, and it is inviting to postulate that the Dacron/macrophage/smooth muscle cell interactions in this atherosclerotic group of patients plays a role in the pathogenesis of this lesion.

Animals↗

The use of Vicryl Collagen as a dura substitute: a clinical review of 78 surgical cases.

We performed a retrospective review of 78 consecutive neurosurgical procedures using Vicryl Collagen, a resorbable mesh of polyglactin 910 coated with bovine collagen, for dural substitution. The complications we encountered were infrequent and mostly minor (5 cases of subcutaneous CSF collections, 2 cases of aseptic meningitis, 1 superficial wound infection), and not unusual for the surgical procedures studied. One patient, however, had a major infection, starting in the superficial tissues, and extending toward the brain. In this patient, the resorption of the dural substitute appeared to be the cause for the intracranial extension of the infection. Three patients were reoperated on for recurrent tumour after a longer interval. We found minimal adhesions and good fibrous incorporation of the Vicryl Collagen into the surrounding normal dura. We conclude that Vicryl Collagen is a valuable alternative to the patient's own fibrous tissues when dural substitution is necessary.

Adolescent↗

A long-term review of posterior colporrhaphy with Vypro 2 mesh.

The objective is to study the long-term outcomes of posterior colporrhaphy with composite polyglactin 910-polypropylene mesh (Vypro 2, Ethicon, Somerville, NJ, USA) utilizing an overlay technique. Seventy-eight patients involved in our previous study were contacted 3 years after their initial operation for follow-up (Lim YN, Rane A, Muller R, Int Urogynecol J 16:126-131, 2005). Thirty-seven (47%) returned for follow-up and completed a standardized questionnaire survey, whereas a further 16 (20%) returned their postal questionnaires. Mean age was 61.3 (SD 10.8) years, and follow-up was 35.7 (SD 4.5) months. There were statistically significant improvements in vaginal lump sensation and constipation (p < 0.001) but no differences with defecatory difficulties or dyspareunia. De novo dyspareunia was reported in 27%. On examination, the incidences of mesh vaginal erosion and rectocele recurrence were 30% and 22%, respectively. It appears that posterior colporrhaphy incorporating Vypro 2 mesh with an overlay method is associated with unacceptably high incidence of complications.

Aged↗

A novel technique for vas deferens transection repairs.

The purpose of this study is to describe a technique, that is as successful as microsurgery in terms of patency rates and histopathologic assessments, and can be performed even by untrained hands in microsurgery, for repairing vas deferens injuries that can be perceived during inguinal herniorrhaphy. Thirty male Wistar-Albino rats were randomly allocated to five groups. In control group, the vas deferens was harvested without any surgical intervention (Group 1) and in sham group the vas was harvested after a limited dissection (Group 2). Three suture approximation technique was carried out in Group 3, and a novel vasovasostomy technique was carried out by using a hypodermal needle in Groups 4 and 5, with polypropylene and polyglactin 910 (rapid vicryl), respectively. Results were evaluated in terms of operative time, patency and flow rates, inflammation and sperm granuloma. The mean operative times for hypodermal needle assisted approximation of Groups 4 and 5 were found significantly less than Group 3. The compared results of the groups in terms of patency, flow rate, inflammation and spermatic granuloma indicated Group 4 to be superior to the other groups. We have found the hypodermal needle assisted approximation technique to be easier, less time consuming and cost effective. With these promising results, this modus operandi can be described as an appropriate technique for vas deferens transection repairs.

Animals↗

A prospective randomized trial of closing laparoscopic trocar wounds by transcutaneous versus subcuticular suture or adhesive papertape.

BACKGROUND: Several methods for closure of trocar wounds are known in laparoscopic surgery. The choice of technique (mostly transcutaneous or subcuticular suture or adhesive papertape) is often based on the surgeon's personal experience. Thus, the objective of this trial was to assess the impact of these closure methods on potential complications of wound healing, cosmetic outcome, and patient satisfaction. METHODS: Sixty patients undergoing operative laparoscopic surgery for gynecologic indications were enrolled in this prospective randomized trial. Five-millimeter port-site incisions were closed either with subcuticular or transcutaneous absorbable sutures (4-0 polyglactin 910) or with adhesive papertape. Postoperative complications, pain, and patient satisfaction with scars were evaluated at 3-month follow-up after operation using a questionnaire. RESULTS: Data from 52 patients who returned the questionnaire were analyzed. Dissatisfying cosmetic results were reported significantly more frequently after subcuticular sutures (p < 0.05). Assessment of patient satisfaction with cosmetic outcome on a visual-analogue scale revealed significantly better results after transcutaneous skin closure than with other approaches (p < 0.05). Adverse wound healing (e.g., infections and dehiscence) was observed most frequently in the subcuticular suture group. Also, the rate of painful scars was highest with this technique. CONCLUSIONS: Transcutaneous closure with absorbable suture material seems to be the most suitable technique for closure of laparoscopic port-site incisions.

Adult↗

Incidence of incisional hernia following vertical banded gastroplasty.

BACKGROUND: Our aim was to determine which patient-related factors influence the incidence of incisional hernia after vertical banded gastroplasty for morbid obesity. METHODS: We reviewed the medical records of 80 morbidly obese patients operated on between 1986 and 1993. All the operations were performed by only one surgeon, and the midline laparotomy was closed by means of continuous polyglactin 910 suture. Statistical analysis was performed using the Fisher exact test, and significance was assigned for values of P<0.05. RESULTS: Incidence of incisional hernia in: obese 24%, superobese 51% ( P=0.0165), men 40%, women 34% ( P=0.7671), age<50 33%, age>50 50% ( P=0.3137), nondiabetics 31%, diabetics 66% ( P=0.0610), no wound infection 34%, wound infection 37% ( P>0.9999), no anemia 31%, anemia 50% ( P=0.1675), no vomiting 39%, vomiting 32% ( P=0.6350). CONCLUSION: The only patient-related factor that significantly influences the incidence of incisional hernia in morbidly obese patients is body mass index.

Adolescent↗

In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureus.

Although mesh use is important for effective herniorrhaphy in adults, prosthetic infections can cause serious morbidity. Bacterial adherence to the mesh is a known precursor to prosthetic infection. We compared the ability of common mesh prosthetics to resist bacterial adherence. The meshes studied included polypropylene (Marlex, expanded polytetrafluoroethylene (PTFE) with and without silver chlorhexidine coating (DualMesh Plus and Dualmesh) composite meshes (Composix E/X, Proceed, and Parietex Composite) and lightweight polypropylene meshes (TiMesh, Ultrapro, and Vypro). Fifteen samples of each mesh type were individually inoculated with a suspension of 10(8 )methicillin-resistant Staphylococcus aureus (MRSA) in tryptic soy broth. After incubation at 37 degrees C for 1 h, the mesh pieces were then removed and serially washed. The colony-forming units (CFU) of MRSA present in the initial inoculum, at the end of the 1-h warm-water bath (broth count), and the pooled washes (wash count), were determined using serial dilutions and spot plating. The bacteria not accounted for in the broth or wash counts were considered adhered to the mesh. Samples of each mesh type were also analyzed using scanning electron microscopy (SEM). Data are presented as the mean percentage adherence with ANOVA and Tukey's test used to determine significance (P<0.05). The DualMesh Plus mesh had no detectable MRSA in the broth or the pooled wash samples. Dualmesh had less adherence compared with Marlex, Proceed, and Vypro (P<0.05). Conversely, Vypro had a statistically higher adherence (96%, P<0.05) as compared to TiMesh, Ultrapro, Composix E/X, and Parietex Composite. SEM confirmed bacterial adherence to all the mesh types except DualMesh Plus. The ability of a biomaterial to resist infection has an important clinical significance. DualMesh Plus, due to its antimicrobial coating, is the only mesh type of the nine tested that demonstrated a bactericidal property. Standard PTFE (Dualmesh) also had less bacterial adherence. Vypro demonstrated an increase in bacterial adherence; this was possibly due to the multifilament polyglactin 910 weaved within the prolene component of the mesh.

Bacterial Adhesion↗