Evaluation of porous polyethylene for external ear reconstruction.

Autogenous rib cartilage and silicone rubber are materials currently used for ear reconstruction. Increased morbidity and operative time with rib cartilage grafts and a high rate of extrusion with silicone implants render them less than ideal for reconstruction of the human ear. The purpose of the current investigation is to determine the efficacy of porous polyethylene as an alternative synthetic material for ear reconstruction. Porous polyethylene and silicone rubber discs of equal sizes in two thicknesses were implanted in lieu of the cartilage in the external ear of eight baboons. Histological evaluation of the sites after nine weeks revealed excellent anchorage of the thin porous polyethylene implants (1.5 mm) in the surrounding tissues. Silicone rubber implants, however, were encapsulated in a thickened granulation tissue capsule. When thicker implants (3.0 mm) were used, exposure or extrusion occurred in all cases. Porous polyethylene implants demonstrated only partial exposure; half of the silicone rubber implants were extruded; and the other two silicone rubber implants were almost completely extruded. Porous polyethylene was thus better incorporated into the soft tissues than silicone rubber as long as the overlying soft tissues were not stressed by an oversized implant or inadequate soft tissue coverage.

Animals↗

Current sterilization and packaging methods for polyethylene.

Gamma sterilization in an air environment can induce oxidation in polyethylene. Oxidation can lead to polyethylene embrittlement, compromising mechanical integrity and clinical performance of polyethylene bearings. For these reasons, orthopaedic manufacturers have modified their methods of sterilizing and packaging polyethylene. Two alternative approaches have emerged: sterilization by non-radiation methods and sterilization by gamma irradiation in inert environments. The current study presents a prognosis for clinical performance of polyethylene sterilized with new methods, based on material property analyses (oxidation levels, mechanical properties, crosslink density) of never implanted and retrieved bearings. Data from bearings that were never implanted which were sterilized with the new methods and shelf aged as many as 3 years, show negligible oxidation, ductility above 400%, and ultimate tensile strength near 50 MPa, all exceeding specifications of the American Society for Testing and Materials. There are significant differences in crosslink density (swell ratio) depending on the sterilization method. Retrievals indicate that bearings sterilized with these new methods are performing well clinically and that the majority are not changing with time. The current study suggests that the shelf oxidation problem has been addressed by these new sterilization techniques and that clinical performance at short followup is acceptable. However, long-term clinical performance must be evaluated in the future.

Drug Packaging↗

Effect of resin type and manufacturing method on wear of polyethylene tibial components.

The purpose of this study was to examine the effect of ultrahigh molecular weight polyethylene resin type and manufacturing method on wear of Miller-Galante I and II tibial knee components. Thirteen Miller-Galante I and 10 Miller-Galante II components were retrieved at revision surgery. The Miller-Galante I tibial components were made by direct compression molding of Hi-fax 1900 resin and the Miller-Galante II tibial components were made by machining from ram extruded rod of GUR 415 resin. Both generations were gamma radiation sterilized in air. The Miller-Galante I retrievals had significantly more wear damage in the form of scratching and embedded metallic debris, whereas the Miller-Galante II retrievals had significantly more wear damage in the form of delamination. For the implants with an implantation time of 5 years or more, the Miller-Galante II polyethylene had a significantly greater maximum density value than did the Miller-Galante I polyethylene. Examination of thin sections of the Miller-Galante II components revealed that delamination occurred through a subsurface region of severely oxidatively degraded polyethylene; no such subsurface degraded region was observed for the Miller-Galante I components. The results of this study suggest that delamination of polyethylene tibial components that have been gamma radiation sterilized (in air) is influenced by resin type or manufacturing method or both.

Adult↗

Five-year experience with Crossfire highly cross-linked polyethylene.

UNLABELLED: Our purpose was to compare the clinical wear performance of highly cross-linked (Crossfire) polyethylene with conventional (N2Vac) polyethylene total hip bearings. We implanted 56 hips (47 patients) with Crossfire acetabular bearing liners and compared their wear performance with 53 conventional polyethylene inserts. Wear and clinical data were collected retrospectively at a minimum 4-year and average 5-year followup. The linear femoral head penetration rate measured from plain radiographs was 0.055 mm/year +/- 0.022 mm/year for the Crossfire polyethylene and 0.138 mm/year +/- 0.073 mm/year for the control, a reduction of 60% for the Crossfire components. Calculated annual wear was 0.036 mm/year for the Crossfire components and 0.131 mm/year for the controls, a reduction of 72%. Radiographic review at most recent followup showed a reduction in erosive osteolytic lesions of the proximal femur for the Crossfire components compared with controls, also suggesting a reduction in debris release for the Crossfire components. Complications leading to revision were not seen in the Crossfire or control groups. These clinical findings suggest that this particular highly cross-linked polyethylene can provide wear reduction and an alternate bearing surface for active patient populations. LEVEL OF EVIDENCE: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate?

In vivo kinematics were determined during a weightbearing deep knee bend in 39 patients implanted with four different designs of mobile-bearing total knee arthroplasty to assess polyethylene bearing mobility patterns and magnitudes. The femoral and tibial components and mobile polyethylene insert (implanted with four tantalum beads) were overlaid onto the fluoroscopic images using a three-dimensional model-fitting technique to determine bearing mobility. Three of the four designs were tested at a single time interval while one was evaluated at two postoperative intervals, (12 months apart) to assess changes in bearing mobility with time. All patients had polyethylene bearing rotation relative to the tibial tray and minimal rotation relative to the femoral component. The average maximum amounts of bearing rotation ranged from 8.4 degrees to 10.3 degrees (range, 3.0 degrees -20.1 degrees). In patients evaluated at two time intervals, the average maximum bearing rotation increased from 8.5 degrees (range, 3.4 degrees -15.5 degrees) at 3 months to 9.8 degrees (range, 48 degrees -14.1 degrees) 15 months postoperatively. The presented data demonstrates polyethylene bearing mobility occurs following mobile-bearing total knee arthroplasty and mobility is maintained during the time interval tested. The presence of bearing mobility should result in lower contact stresses reducing the potential for polyethylene wear.

Biomechanical Phenomena↗

Polyethylene glycol 3350 for constipation in children with dysfunctional elimination.

PURPOSE: Children with daytime wetting often have constipation, and treatment of constipation helps children become dry. Polyethylene glycol 3350 (Miralax, Braintree Laboratories, Braintree, Massachusetts) is a nonaddictive, tasteless powder that can be mixed with any liquid for treatment of constipation. MATERIALS AND METHODS: We review our use of polyethylene glycol 3350 in 35 girls and 11 boys with dysfunctional elimination. Noninvasive urodynamic studies and post-void residual measurement were performed before and during treatment. RESULTS: A significant increase in frequency of bowel movements occurred while taking polyethylene glycol 3350 (p = 0.0001). Average final dose was 0.63 gm/kg. The only reported adverse effect was diarrhea (9 patients). Of the children 18 became dry, 26 had decreased wetting and 2 had no improvement. Voided volume increased (146 vs 210 ml, p <0.0001) and post-void residual decreased significantly (92 vs 48 ml, p <0.0001) while on polyethylene glycol 3350. Ten children were still considered constipated including both patients who experienced no change in wetting. Average final dose in this group (0.69 gm/kg) did not differ significantly from those in whom constipation resolved (0.61 gm/kg). Patients in whom constipation resolved had a significantly lower post-void residual than those who remained constipated (11.8% vs 30.6%, p <0.01) and were significantly more likely to become dry or improved (p = 0.045). CONCLUSIONS: The efficacy, compliance and lack of significant side effects make polyethylene glycol 3350 an ideal substance for treatment of constipation in children with dysfunctional elimination. Persistent constipation was associated with decreased resolution of voiding symptoms and significantly increased post-void residuals.

Biofeedback, Psychology↗

Augmentation mentoplasty with diced high-density porous polyethylene.

BACKGROUND: Augmentation mentoplasty is a common procedure, applied especially in conjunction with rhinoplasty. Although various materials have been used for this procedure, diced high-density porous polyethylene (Medpor) has not been used so far. The purpose of this study was to evaluate the use of diced high-density porous polyethylene in chin augmentation. METHODS: A subperiosteal pocket is prepared through submental incision. A high-density porous polyethylene block is diced into 1 x 1.5-mm pieces, to be placed into the subperiosteal pocket as much as needed by wrapping into oxidized cellulose (Surgicel). Immediately after the incision is closed, shaping with external massage is performed and an external bandage is applied. RESULTS: This procedure was performed in 20 patients, in addition to rhinoplasty, with a mean follow-up of 14 months (range, 8 to 20 months). Five to 14 mm of augmentation was achieved. There were no complications, except for early seroma formation in three patients, which required aspiration by syringe. It is easy to give shape to diced high-density porous polyethylene by means of massage 3 weeks after surgery. CONCLUSIONS: Diced high-density porous polyethylene in augmentation mentoplasty is cheap, easy to insert, and moldable by external massage, and has flexibility in conforming to the shape of the mandible. It also avoids all the disadvantages of monobloc implants, allowing postoperative ingrowth of fibrous tissues, precluding late displacement, and giving a natural feel to the reconstructed area.

Adolescent↗

Degradation of ethylene glycol and polyethylene glycols by methanogenic consortia.

Methanogenic enrichments capable of degrading polyethylene glycol and ethylene glycol were obtained from sewage sludge. Ethanol, acetate, methane, and (in the case of polyethylene glycols) ethylene glycol were detected as products. The sequence of product formation suggested that the ethylene oxide unit [HO-(CH2-CH2-O-)xH] was dismutated to acetate and ethanol; ethanol was subsequently oxidized to acetate by a syntrophic association that produced methane. The rates of degradation for ethylene, diethylene, and polyethylene glycol with molecular weights of 400, 1,000, and 20,000, respectively, were inversely related to the number of ethylene oxide monomers per molecule and ranged from 0.84 to 0.13 mM ethylene oxide units degraded per h. The enrichments were shown to best metabolize glycols close to the molecular weight of the substrate on which they were enriched. The anaerobic degradation of polyethylene glycol (molecular weight, 20,000) may be important in the light of the general resistance of polyethylene glycols to aerobic degradation.

Acetates↗

Polyethylene glycol precipitation for recovery of pathogenic viruses, including hepatitis A virus and human rotavirus, from oyster, water, and sediment samples.

Polyethylene glycol 6000 precipitation was found to be an effective concentration method that enhanced the chances for detecting human virus pathogens in environmental samples. Percent recoveries from eluates of fresh and estuarine waters with 8% polyethylene glycol 6000 averaged 86 for hepatitis A virus, 77 for human rotavirus Wa, 87 for simian rotavirus SA11, and 68 for poliovirus. Percent recoveries of 97, 40, 97 and 105, respectively, for the same viruses were obtained from oyster eluates by the same procedure. Percent recoveries of 97 for hepatitis A virus and 78 for human rotavirus Wa were obtained from sediment eluates containing 2 M NaNO3 with a final concentration of 15% polyethylene glycol 6000. The polyethylene glycol method was shown to be more effective than the organic flocculation method for recovery of hepatitis A virus and rotaviruses Wa and SA11, but not of poliovirus 1 in laboratory studies. In field trials, hepatitis A virus or rotavirus or both were recovered from 12 of 18 eluates by polyethylene glycol, compared with recovery from 9 of 18 eluates by organic flocculation from fresh and estuarine waters subject to pollution.

Animals↗

Isolation and characterization of wear debris generated in patients wearing polyethylene Hylamer inserts, gamma irradiated in air.

Hylamer polyethylene was used in the early 1990s to make hip-joint components. Clinical experience has shown that these components, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which then leads to osteolysis. The authors analyzed polyethylene wear particles in seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening. The results were compared to those of six controls, who had received traditional polyethylene implants, sterilized by the same method. The frequency distribution of globular and fibrillar particles was similar in both groups (38.5% in Hylamer, 45.2% in controls). The globular particles in the Hylamer samples had a mean area of 0.12 microm2, which was significantly lesser than that of the controls (0.30 microm2). The width of fibrillar particles in the Hylamer samples was significantly lesser than that of the controls. Therefore, the two materials, despite undergoing the same type of sterilization, produced different types of wear, due to their different properties. In conclusion, the difference in the morphology of Hylamer polyethylene wear particles in comparison with PCA might have caused a more intensive biological response, early and massive osteolysis, and therefore, early loosening.

Aged↗

Polyethylene-starch extrudates as erodible carriers for bioactive materials: I. Erodibility and in vitro dye release studies.

The objective of the present investigation is to develop and evaluate polyethylene-starch based carriers for sustaining the release of bioactive materials. Polyethylene-starch carriers were prepared by incorporating various amounts of corn starch 0, 40, 80, and 100% in polyethylene beads with and without dye. Acid orange dye was incorporated (1%) to study release patterns and the effect of starch (%) on release. The granulated mixtures were extruded to form uniform dispersions of starch and polyethylene throughout the extrudate. The extrudates obtained were studied for SEM surface characterization before, during, and after release studies to study the erosion process. In the case of 100% starch, 80% of the matrix was eroded in 5 weeks, while with 40% and 80% starch, erosion was less than 20%. The dye release studies showed that release could be sustained well over 12 weeks, depending on the starch (%) incorporated. The erosion process was studied using scanning electron microscopic techniques, which showed gradual erosion of starch particles, leaving a polyethylene skeleton. These materials show promising potential for use as carriers for bioactive materials.

Coloring Agents↗

Fluid absorption study in ultra-high molecular weight polyethylene (UHMWPE) sterilized and unsterilized acetabular cups.

The weight gain due to fluid absorption was measured in gamma-sterilized, ethylene oxide (ETO) gas-sterilized, and unsterilized ultra-high molecular weight (UHMW) polyethylene acetabular cups. After about 2 months the total average fluid absorption gain of the polyethylene cups was: 1.76 +/- 0.45 mg (average +/- standard deviation) for the unsterilized polyethylene cups, 2.81 +/- 0.95 mg for the gamma-sterilized polyethylene cups and 1.51 +/- 0.34 for the ETO gas-sterilized polyethylene cups. There was little difference in fluid absorption between the sterilized and unsterilized specimens. In particular, the gamma-sterilized acetabular cups absorbed more than the ETO gas-sterilized and the unsterilized cups. However, the weight gain was higher in serum compared with that in water.

Absorption↗

[Gel and porous polyethylene implants in the rabbit anophthalmic cavity].

PURPOSE: To evaluate porous polyethylene implants as compared to solid and gel spheres in anophthalmic cavities. METHODS: Thirty-six white rabbits underwent a right eye enucleation with placement of 12 mm of porous (18 animals) or gel (18 animals) polyethylene spheres. The animals were submitted to weekly clinical evaluation. Ultrasound examinations were done 30, 60 and 90 days after surgery and the animals were sacrificed on the day 90th. Then, the orbit content was removed and submitted to light microscopy. RESULTS: Five animals (27.2%) which received porous polyethylene spheres presented sphere extrusion. With the gel polyethylene spheres, the extrusions happened in 94.4% of the animals and it was observed that the expelled gel spheres had higher diameter then the implanted ones. Ultrasound evaluation showed that the porous polyethylene implant becomes vascularized but the gel not, as confirmed by histological examination. CONCLUSION: Spheres of material in the gel state hydrate and increase in volume making it necessary to know the final size before the implantation. Ultrasound examination allows the evaluation of the implant-tissue integration.

Animals↗

Mechanical stability of polyethylene liners cemented into acetabular shells.

Revision of well-fixed, metal-backed acetabular components for dislocation or polyethylene failure requires consideration of removing the entire construct or replacing the polyethylene liner only. For non-modular or first-generation modular components with poor locking mechanisms, one option is to cement undersized liners into well-fixed shells. The purpose of this study was to measure the stability of undersized liners cemented into metal acetabular shells and compare the results with those of modular components. Hooded polyethylene liners measuring 28 x 50 mm and 28 x 56 mm were cemented into 66-mm acetabular shells (Smith & Nephew, Inc., Memphis, TN) with Simplex-P polymethylmethacrylate cement (Howmedica, Inc., Rutherford, NJ) giving 4- and 2-mm cement mantles, respectively. The force required to lever-out the liners from the shells was measured using the protocol described by Tradonsky et al. Assemblies with 4-mm mantles dissociated at an average of 322 +/- 47 in-lbf.; however, the assemblies with 2-mm mantles would not dissociate before the polyethylene yielded at torques as high as 600 in-lbf. These results compare favorably with the previously reported range (43 to 684 in-lbf) for modular acetabular components. These results suggest that undersized polyethylene liners can be cemented into well-fixed acetabular shells and expected to be stable.

Arthroplasty, Replacement, Hip↗

The effect of ultra-high molecular weight polyethylene wear debris on MG63 osteosarcoma cells in vitro.

BACKGROUND: Focal osteolysis due to ultra-high molecular weight polyethylene wear debris involves effects on both bone resorption and bone formation. METHODS: The response of MG63 osteoblast-like osteosarcoma cells to ultra-high molecular weight polyethylene wear debris isolated by enzymatic digestion of granulomatous tissue obtained from the sites of failed total hip arthroplasties was examined. Scanning electron microscopy, particle-size analysis, and Fourier transform infrared spectroscopy were used to characterize the number, morphology, size distribution, and chemical composition of the particles. Cell response was assessed by adding particles at varying dilutions to confluent cultures and measuring changes in cell proliferation (number of cells and [3H]-thymidine incorporation), osteoblast function (alkaline-phosphatase-specific activity and osteocalcin production), matrix production (collagen production and proteoglycan sulfation), and local cytokine production (prostaglandin-E2 production). RESULTS: The mean size of the particles was 0.60 micrometer, and 95 percent of the particles had a size of less than 1.5 micrometers. The number of particles per gram of tissue ranged from 1.39 to 3.38x10(9). Three of the four batches of particles were endotoxin-free. Exposure of the cells to particles of wear debris significantly increased the number of cells (p<0.05) and the [3H]-thymidine incorporation (p<0.05) in a dose-dependent manner. In contrast, the addition of particles decreased alkaline-phosphatase-specific activity and osteocalcin production. Collagen production and proteoglycan sulfation were also decreased, while prostaglandin-E2 synthesis was increased by the addition of particles. CONCLUSIONS: Ultra-high molecular weight polyethylene particles isolated from human tissue stimulated osteoblast proliferation and prostaglandin-E2 production and inhibited cell differentiation and matrix production. These results indicate that particles of wear debris inhibit cell functions associated with bone formation and that osteoblasts may produce factors in response to wear debris that influence neighboring cells, such as osteoclasts and macrophages. CLINICAL RELEVANCE: Particles of wear debris, especially ultra-high molecular weight polyethylene, have been implicated in the loosening of implants and the development of osteolysis. The present study shows that particles of ultra-high molecular weight polyethylene isolated from human tissue inhibit osteoblast functions associated with bone formation. In addition, particles of wear debris induced osteoblasts to secrete factors capable of influencing neighboring cells, such as osteoclasts and macrophages. These results suggest that osteoblasts may play a role in the cascade of events leading to granuloma formation, osteolysis, and failure of orthopaedic implants.

Adult↗

Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty.

BACKGROUND: Debris from polyethylene wear causes osteolysis. In this study, we examined the effect of acetabular liner modularity on polyethylene wear and osteolysis. METHODS: We compared forty-one hips (thirty-nine patients) treated with a nonmodular, porous-coated acetabular component with a matched group of forty-one hips (forty patients) treated with a modular acetabular component. The groups were matched by patient gender and age, type of polyethylene material, method of polyethylene sterilization, femoral head size and manufacturer, and stem manufacturer. The mean follow-up period was 5.3 years (range, 3.8 to 6.8 years) for the nonmodular group and 5.5 years (range, 3.8 to 8.0 years) for the modular group. Using serial radiographs and a computer-assisted method, we measured two-dimensional head penetration into the polyethylene liner. Temporal head-penetration data and linear regression analysis were used to calculate the true wear rates. RESULTS: The nonmodular acetabular components demonstrated a lower, but not a significantly lower, mean true wear rate than did the modular components (0.11 compared with 0.16 mm/yr, p = 0.22), and they were associated with a significantly lower rate of osteolysis (2% compared with 22%, p = 0.01). In addition, the true wear rates of the nonmodular components were less variable than those of the modular components. The 95% confidence interval for the wear rates of the nonmodular components (0.08 to 0.13 mm/yr) was nearly half that of the modular group (0.11 to 0.20 mm/yr). CONCLUSIONS: The lower and more consistent true wear rates of the nonmodular components could be attributed to the fact that these cups were designed to have greater liner-shell conformity, greater liner thickness, and less liner-shell micromotion than modular components. These design factors could have favorably altered the stress distribution throughout the liner and could have thereby decreased wear. Although nonmodular components may present a partial solution to the problems of wear and osteolysis, they pose a disadvantage when a failed liner in a bone-ingrown acetabular component needs to be revised.

Acetabulum↗

Nitric oxide and prostaglandin E2 production in response to ultra-high molecular weight polyethylene particles depends on osteoblast maturation state.

BACKGROUND: Recent studies have shown that osteoblast-like cells respond directly to ultra-high molecular weight polyethylene particles in culture, suggesting that they may be involved in aseptic loosening of endoprostheses. We tested the hypothesis that the state of cell maturation plays a role in the response of osteogenic cells to ultra-high molecular weight polyethylene particles. METHODS: MG63 cells (immature osteoblast-like cells), OCT-1 cells (mature secretory osteoblast-like cells), and MLO-Y4 cells (osteocyte-like cells) were treated for twenty-four hours with commercial ultra-high molecular weight polyethylene particles with an average diameter of 1 mm. The effect of particle treatment on cell proliferation was assessed by measuring the number of cells, whereas the effects on differentiation and local factor production were assessed by measuring the production of osteocalcin, prostaglandin E2, and nitric oxide. The effect of particles on apoptosis was also evaluated. RESULTS: The addition of ultra-high molecular weight polyethylene particles increased the number of MG63 cells, did not affect the number of OCT-1 cells, and led to a decrease in the number of MLO-Y4 cells. The observed changes in cell number were not due to programmed cell death, as no more than 3% of the cells in cultures treated with the highest concentration of particles were undergoing apoptosis. Osteocalcin production was not affected by the addition of particles. Prostaglandin E2 production was increased in all three types of cultures, but the effect was greatest in OCT-1 cell cultures, as was the absolute amount of prostaglandin E2 produced. Nitric oxide production was unaffected in MG63 cell cultures, but it was stimulated in OCT-1 and MLO-Y4 cell cultures. CONCLUSIONS: The results of the present study support the hypothesis that osteoblast cell maturation state plays an important role in the response to ultra-high molecular weight polyethylene particles and that the terminally differentiated osteocyte may be involved in the bone response to wear debris in vivo.

Alprostadil↗

Polyethylene wear and acetabular component orientation.

BACKGROUND: Polyethylene wear contributes substantially to both periprosthetic osteolysis and aseptic loosening after total hip arthroplasty. Acetabular component orientation has been shown to affect the range of motion of the hip as well as contact stresses. A series of studies was designed to test the hypothesis that acetabular component orientation can affect the magnitude and direction of polyethylene wear. METHODS: A finite-element model was used to compute contact stresses during a normal gait cycle. Wear at the end of each gait cycle was calculated with use of the sliding-distance-coupled finite-element formulation. The wear that was calculated with use of finite-element analysis was validated by comparison with the findings of hip wear simulator studies with the acetabular liner oriented to simulate 45 degrees and 55 degrees of abduction. In a clinical study, fifty-six patients who underwent sixty hip arthroplasties with use of a single prosthetic design were followed for as long as five years. Radiographs were analyzed to measure the abduction angle of the acetabular component and polyethylene wear. RESULTS: The finite-element analysis predicted increased peak contact stresses with an increased abduction angle and reduced peak contact stresses with an increased anteversion angle. Linear wear rates ranging from 0.036 to 0.045 mm/million cycles were also predicted, and increased acetabular abduction angles were predicted to be associated with higher linear wear rates. In the hip wear simulator studies, significantly different wear rates were found between the cups with acetabular abduction angles of 45 degrees and 55 degrees (mean, 17.2 compared with 21.7 mg/million cycles; p < 0.01). In the clinical study, radiographic analysis revealed significant correlation between the acetabular abduction angle and the linear polyethylene wear rate. A 40% increase in mean linear polyethylene wear was seen in cups with an abduction angle of >or=45 degrees. The direction of wear was more medial (by 9.4 degrees ) in cups with an abduction angle of <45 degrees. CONCLUSION: All three studies presented here underlined the importance of optimizing the position of the acetabular component. Careful attention to acetabular position may help to minimize wear.

Aged↗