Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polydioxanone”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

[The role of suture material on healing of vascular anastomosis].

The effect of suture material on healing of vascular anastomosis was examined. Four types of vascular grafts, i.e., autogenous vein, preserved human umbilical cord vein, expanded polytetrafluoroethylene and double velour knitted Dacron, were implanted into the abdominal aorta of 78 adult mongrel dogs using two kinds of absorbable sutures (multifilament polyglycolic acid: PGA and monofilament polydioxanone: PDS) and a nonabsorbable suture (polypropylene: PP). The macroscopic findings and the histologic examinations showed that hyalinoid degeneration and calcification resulting from tissue ischemia due to tight and long lasting suture loops interfered with tissue healing at the PP-anastomotic site. On the other hand, fairly good healing of the anastomoses was observed with absorbable sutures because of the reduction of ischemia. The absorbable suture-anastomoses could tolerate systemic blood pressure within one month after implantation, and there was no anastomotic disruption at 1000 mmHg pressure in the bursting test 12 months after grafting. From Dec., 1984, 55 anastomoses in 34 bypass-operations employing autogenous vein grafts were performed using PGA and PDS in 28 cases clinically. There were no anastomotic complications. In conclusion, the synthetic absorbable suture material, especially in the form of monofilament, seems to be most suitable for suturing or anastomosing autogenous small vessels at present.

Absorption↗

[Distal radius fracture. Fracture stabilization with biodegradable osteosynthesis pins (Biofix). Experimental studies and initial clinical experiences].

K-wire stabilization and casting of unstable or intraarticular fractures of the distal radius has proven to be an effective method of treatment since many years. However the need of implant removal after fracture healing is a disadvantage of this method. For this reason we investigated on the use of biodegradable implants in a fracture model of the distal radius. The biomechanical testing with Polydioxanon-(PDS)-pins (Ethipin) showed too small primary stability for the use in vivo. Osteosyntheses with three Polyglycolacid-(PGA)-rods Biofix compared with three K-wires 1.6 mm on the other hand showed 82% initial stability. From May to September 1988 typical distal radius fractures in 11 patients have been stabilized with Biofix-rods. The result of primary reduction could be obtained in all cases. These first experiences suggested, that stabilization of distal radius fractures with Biofix-rods might alternatively be performed instead of K-wire pinning.

Adult↗

[Resorbable implants and their use exemplified by fracture of the head of the radius].

First a short survey of the variety of experiments concerning absorbable implants is given. The result of those experiments, especially with large implants are still quite unsatisfactory. For small osteosynthesis the development of Polydioxanon-Pins seems to open new perspectives of therapy. Also some selected indications in the field of hand surgery as well as maxillary surgery are mentioned. Promising characteristics of PDS-Pins, such as gentle application, complete absorbability, no late infections and no removal of metal plates, made us implant these pins in eight patients aged 35 to 58 suffering from radial head fractures (type Ib and Ic according to Vogt). Early functional treatment showed very good results. Two exemplary cases are illustrated.

Female↗

[Behavior of modern suture materials in infected urine].

The recently developed absorbable materials demonstrate a constant and reproducible high quality when compared with the resorbable suture materials. However, based on in vitro studies by different authors the use of these materials in infected urine is not recommended. We investigated in vivo in infected urines the stability of the suture materials composed of polyglycolic acid, and compared the results obtained in vitro and in vivo. In a controlled study the stability of the absorbable suture materials polyglycolic acid, polyglactin 910 and polydioxanon 4/0 USP were tested in infected urine in vivo and in vitro. In 21 patients with infected urine the suture materials were placed into the bladder for 7 days. In another experiment these materials were incubated up to 7 days in culture flasks with infected urine. After that the suture materials were examined by densitometry and electrone microscopy. When using the results obtained in vitro in clinical work caution is recommended. However, the in vivo tests show that the stability of the newly developed absorbable materials is not influenced dramatically by the infected urine.

Bacteriuria↗

Pyloric exclusion. Suture material of choice.

Pyloric exclusion was first reported in 1977 as a temporary method of providing duodenal decompression in an attempt to protect the duodenum in the early postoperative period during the healing phase, followed by the return of normal gastrointestinal transit. It has been adopted by several trauma centers across the country as part of their armamentarium for managing moderate to severe duodenal injuries. Most series report using a polyglycolic acid (PGA) suture in performing the exclusion, anticipating a 3- to 4-week interval before pyloric patency is re-established. A comparison of polypropylene (PP), polyglycolic acid (PGA), and polydioxanone (PDS) sutures in the dog model suggests, however, that only PDS reliably accomplishes this goal. The low (approximately 5-10%) but finite incidence of fistula formation reported with pyloric exclusion using PGA may be improved by using PDS instead.

Animals↗

In-vivo comparison of four absorbable sutures: Vicryl, Dexon Plus, Maxon and PDS.

Absorbable sutures are initially equal or superior to nonabsorbable sutures in terms of tensile strength but are absorbed at variable rates by the action of hydrolysis. This study demonstrated that the in-vivo half-life tensile strength of the braided absorbable sutures polyglycolic acid (Dexon Plus) and polyglactin 910 (Vicryl) is 2 weeks, whereas those of the monofilament absorbable sutures polyglyconate (Maxon) and polydioxanone (PDS) are 3 and 6 weeks respectively. The addition of a single hitch or six knots reduced the in-vitro tensile strength by 30% to 35%. Polyglyconate (Maxon) suture demonstrated the best in-vitro knot security.

Animals↗

[Resorbable implants for refixation of osteochondral fragments in joint surfaces].

Resorbable pins made of solid polydioxanone (PDS) were tested for refixation of osteochondral fragments. In both medial femoral condyles of sheep osteochondral fragments were chiselled and refixed by 3 PDS pins. After 3 months the sheep were sacrificed and healing of the fragments investigated histologically and biomechanically. Fragment dislocation was not seen in any of the cases and the cartilage surface could be described as normal. The strength of the bone healing zone reached 80% of the strength of the normal bone. The contact surface between fragment and subchondral bone showed complete bony healing. Only the border of the cartilage flake was still visible. The PDS pins had not been completely biodegraded after 3 months.

Animals↗

[PDS splint in the treatment of fractures].

Polydioxanon-splints have been used instead of Kirschner-wires in 13 cases for the treatment of fractures of the base or head of phalanges and metacarpals and also, in conjunction with intraosseous suture wires, to stabilize the bones in replantation surgery.

Bone Wires↗

[Resorbable PDS splints in fracture stabilization and for arthrodeses of the hand].

Small rods of resorbable Polydioxanon (PDS-splints) are suitable for stabilizing fractures of a phalanx, either near the base or the head, be the fracture transverse or comminuted. Such internal splints are especially useful in replantation of clean amputations. Used in combination with intraosseous wiring, osteosynthesis can be achieved that is stable for exercise in all cases. Another use is in arthrodesis of the distal interphalangeal joints and the metacarpophalangeal joint of the thumb. Disadvantages that accompany Kirschner wire fixation are thus avoided. Case descriptions and results are presented.

Adult↗

[Absorbable synthetic clips and pulmonary excision. Our clinical experience].

Analysis of the first 50 clinical cases confirmed conclusions of experimental studies in large animals with respect to the use of absorbable synthetic clips formed of lactomer and polydioxanone. The advantages of clips when compared with ligatures include rapidity and simplicity of use and ease of insertion, even in regions difficult to approach surgically with the fingers. The advantages of clips of the absorbable synthetic type over conventional metallic material are: safety and reliability due to their locking system and the conservation of sufficient residual resistance, improved behavior in biologic media, radio-transparency and total inertia in magnetic fields compatible with postoperative radiation and modern medical imaging procedures (CT scan, IRM), and finally progressive resorption predictable by simple hydrolysis and then total disappearance after 6 to 7 months. With staplers of the TA and GIA type these clips make sutures and ligatures during lung resection surgery entirely automatic.

Absorption↗

Comparison of Maxon suture with Vicryl, chromic catgut, and PDS sutures in fascial closure in rats.

Two hundred ten rats were randomized into one of five study groups to compare standard absorbable sutures with a new synthetic absorbable suture. We evaluated Maxon (polyglyconate), Vicryl (polyglactin), chromic catgut (catgut), and PDS (polydioxanone) with respect to tissue inflammatory reaction, knot security, suture tensile strength, and suture absorption. The results indicate that Maxon and PDS elicited a lower degree of chronic inflammation when compared with Vicryl and chromic catgut. The tensile strengths of Maxon and Vicryl significantly exceeded those of PDS and chromic catgut during the critical period of wound healing. Maxon and PDS retained a larger percentage of tensile strength during the long postoperative period, whereas Vicryl and chromic catgut were mostly absorbed. Maxon is an excellent addition to the armamentarium of the gynecologic surgeon.

Absorption↗

Tissue reactions to absorbable ligating clips.

Scanning electron microscopy was used in a comparative ultrastructural study of biodegradable ligating clips, the Absolok (polydioxanone) and the Lactomer (copolymer of glycolic and lactic acids), implanted subcutaneously in rabbits. The inflammatory response and tissue reactions to the implanted clips and their effects on clip breakdown were studied. By the first week after implantation, numerous inflammatory cells adhered to the clip surfaces, with occasional fibroblasts present. By two weeks after implantation there was a reduction in the number of inflammatory cells, but the number of fibroblasts gradually increased, resulting in encapsulation of the clips. The thickness of the fibrous tissue capsule, formed by a variety of collagen fibers, gradually increased 5-25 weeks after implantation. Residues from the Lactomer clips were still present within the encapsulating tissue at 25 weeks. In contrast, clips enclosed in nylon pouches were totally degraded, and no residues were detectable at 25 weeks. Tissue reactions similar to those observed for nonpouched implanted clips were seen over the entire external surface of the pouches.

Animals↗

[Atraumatic closure of skin defects].

A method of atraumatic wound closure published by Ambroise Pare [1] was carried out by suturing of crosstrips (Mefix-Mölnlycke) fixed along and upon the wound margins, combined with intradermal continuous sutures (absorbable monofilament polydioxanone--4-0, Ethicon).

Humans↗

[Experiences with a resorbable suture (PDS) in tendon sutures].

67 tendon sutures were performed on 29 patients using polydioxanon (PDS), a synthetic absorbable suture material. The results after a mean survey period of twelve months are documented; there were no ruptures and fistula, only two infections and in four cases the need for tenolysis. In the reconstruction of isolated flexor tendon injuries 89% excellent results were found. The satisfactory and bad results in reconstructing flexor and extensor tendon injuries accompanied by complex hand injuries are analyzed and discussed.

Adolescent↗

[Absorbable synthetic clips and pulmonary excision].

From the beginning of this decade, two new, 2nd generation, resorbable synthetic materials--polydioxanone and lactomer--have been able to be molded into clips which, in contrast to metallic clips, are fitted with an original locking system preventing any slipping, either transversal or longitudinal, on the vessels. An experimental study was conducted to confirm their great reliability and perfect safety on large vessels (up to 8-9 mm) of large laboratory animals--both pulmonary and systemic vessels. Positive results justified their application to pulmonary vessels in humans during surgery, the pulmonary vessel being at a much lower pressure than in the main circulatory system. These new clips possess the advantages of metallic clips and resorbable synthetic threads without their inconveniences: rapidity, simplicity and ease of application, radio-transparency and complete inertia in magnetic fields enabling radiotherapy and modern postoperative investigations (scanner, NMR...) to be carried out.

Absorption↗

[Resorbable suture material in cardiovascular surgery?].

The examination of a new, fully resorbable suture material (polydioxanon) in case of artery sutures is reported. Smaller tissue reactions are found than in all suture materials examined. Exceptional long durability for fully resorbable suture material seems in case of anastomoses in vessels very usefull.

Animals↗

Comparison between absorbable and nonabsorbable, monofilament sutures for end-to-end arterial anastomoses in growing pigs.

End-to-end anastomoses of the iliac arteries in growing pigs were constructed with interrupted 7-0 absorbable polydioxanone (PDS) or polypropylene (Prolene) sutures. Comparison between the two monofilament suture materials was made with respect to macroscopic and microscopic examinations, angiographic findings, recorded tensile breaking forces, and calculated blood flow values within the arterial walls at the level of the anastomoses. The angiographic examinations and the recorded tensile breaking forces did not reveal any difference between PDS- and Prolene-sutured anastomoses. On the other hand, the macroscopic findings, the histologic examination, and the calculated blood flow values (6.1 +/- 4.7 and 16.8 +/- 2.3 ml/min/100 gm for PDS- and Prolene-sutured anastomoses, respectively) point to a far more pronounced inflammatory tissue reaction with Prolene. The obtained differences clearly suggest the use of absorbable PDS instead of nonabsorbable Prolene sutures for arterial anastomoses.

Animals↗

Knotting abilities of a new absorbable monofilament suture: poliglecaprone 25 (Monocryl).

OBJECTIVE: To study the mechanical knotting abilities of the new synthetic absorbable monofilament suture poliglecaprone 25 (Monocryl) compared with other absorbable suture materials. DESIGN: Experimental laboratory study. MATERIAL: Knotted loops (3/0 USP) of five synthetic absorbable sutures: Monocryl (poliglecaprone 25), PDS-2 (polydioxanone), Maxon (polyglyconate), Vicryl (polyglactin-910) and Dexon-Plus (polyglycolic acid). Three different knots were tested in a total of 150 experiments. MAIN OUTCOME MEASURES: Mean loop holding capacity (LHC) of 10 experiments, expressed in Newtons (N). RESULTS: Monofilament Maxon tied significantly more secure knots than the other sutures. Sliding knots of Monocryl (poliglecaprone 25) were similar to, and three-throw square knots were less secure than those tied with monofilament PDS-2. Braided Dexon-Plus was superior to Monocryl for sliding knots but comparable for square knots. Braided Vicryl did not differ significantly from Monocryl. CONCLUSION: The mechanical knot performance of Monocryl is identical to that of Vicryl, less than that of one other synthetic absorbable monofilament suture (Maxon) and comparable to or somewhat less than the other alternative (PDS-2). These findings, together with other characteristics such as degradation rate, should be used to define the application of Monocryl.

Dioxanes↗