Search PubMedSearch

SEARCH · Search PubMed

Results for “Patient Reported Outcome Measures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,097 records · Page 18Linked to original sources

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Digital healthcare solutions in preoperative care: A systematic review.

OBJECTIVE: Active participation in preoperative anesthesia preparation is crucial to ensure safe and efficient care. Compliance with preoperative instructions improves clinical outcomes, enhances patient satisfaction and optimizes use of healthcare resources. As digital communication becomes increasingly integrated into healthcare, interactive digital tools such as smartphone applications and Short Message Service (SMS) reminders may offer a valuable means of engaging patients in their own care. In this review, we evaluated the role of digital tools in guiding patients during their preoperative care pathway for anesthesia. METHODS: Following registration (CRD420250655119), we conducted a systematic review of studies evaluating the use of smartphone applications or SMS reminders designed to support preoperative preparation for anesthesia or procedural sedation in adult patients undergoing elective procedures. The primary outcome was compliance with preoperative instructions. Secondary outcomes included rate of late cancellations, patient satisfaction and cost-effectiveness. Studies were eligible if they reported at least one of these outcomes. RESULTS: Ten studies (1 RCT and 9 observational studies), including 11501 participants, were identified. Compliance with preoperative instructions was assessed in 8 studies, most of which reported higher compliance in patients receiving digital interventions across multiple instruction domains, although statistical significance was not consistently observed. Evidence suggested a beneficial effect on reducing late cancellations and improving patient satisfaction. However, results varied across study designs, and data on cost-effectiveness were limited. CONCLUSIONS: Digital tools for preoperative anesthesia guidance were associated with higher compliance and showed potential reduction of late cancellations and increase of patient satisfaction. However, the current evidence is predominantly observational and heterogeneous, limiting the strength of conclusions. PRACTICAL IMPLICATIONS: With healthcare systems under pressure, digital technologies may offer a scalable and patient-centered care solution to support preoperative anesthesia preparation. Nonetheless, further high-quality research is needed to evaluate their long-term clinical, economic and equity implications.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.

BACKGROUND: For a valid one-repetition maximum (1RM) prediction via load-velocity (LV) relationships, high reliability and accuracy must be assumed. OBJECTIVE: Since individual study results indicate ambivalent prediction, this systematic review and meta-analysis was designed to provide a updated and comprehensive overview, extending knowledge about the validity and reliability of commercially available velocity sensors in Part I and the validity and reliability of velocity-based 1RM prediction models in Part II. METHODS: A systematic literature search was conducted in PubMed/MEDLINE, Web of Science, and Scopus. Validity and/or reliability studies or velocity-based 1RM prediction evaluations were included. Methodological quality was assessed using adapted COSMIN. The analysis was performed for intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), and Pearson's correlation coefficient (r). The review was preregistered in PROSPERO (CRD42025634595). RESULTS: Sixty-three studies were included for sensor validity and reliability and 38 for 1RM prediction models. Part I: Velocity sensors demonstrated good-to-excellent pooled validity and device agreement (ICC&#x2009;=&#x2009;0.91-0.92 [0.83-0.97]; k&#x2009;=&#x2009;55 and 439, respectively); intra- and inter-day reliability were classified as good to excellent with ICC&#x2009;=&#x2009;0.90-0.91 [0.85-0.95] (k&#x2009;=&#x2009;228 and 608, respectively), with sensor technology moderating the results. However, substantial heterogeneity and wide ranges of study-level estimates indicated considerable variability across moderators, linear position transducer (LPT) generally showing more consistent performance than inertial measurement units (IMU). Part II: Velocity-based 1RM prediction showed ICCs&#x2009;=&#x2009;0.90 [0.83-0.94] (k&#x2009;=&#x2009;124) and ICC&#x2009;=&#x2009;0.91 [0.72-0.98] (k&#x2009;=&#x2009;9); for reliability and validity, respectively. DISCUSSION: Commercial velocity sensors generally provide high relative validity and reliability. Results varied depending on exercise complexity, intensity, sensor technology, and modeling approach. While velocity-based 1RM prediction demonstrated high average validity, large heterogeneity in lower body exercises significantly biased the results. Furthermore, the dearth of measurement error and agreement analyses prohibits final conclusions. CONCLUSION: Therefore, velocity-based monitoring and 1RM prediction require cautious interpretation, as sensor- and exercise-specific evidence remains limited.

Load&#x2013;velocity relationship

Tele-Oncology in the Post-Pandemic Era: Clinical Integration, Access Disparities and Medico-Legal Accountability.

PURPOSE OF THE REVIEW: Tele-health has evolved from a marginal tool confined to rural populations and selected follow-up programs into a structurally integrated component of modern cancer care. Prior to COVID-19, its adoption was constrained by regulatory fragmentation, non-uniform reimbursement, and licensure barriers. This narrative review evaluates the evolutionary integration of tele-health in oncology post-COVID-19, examines digital disparities across patient populations, and addresses the medico-legal implications of this integration, with the objective of providing a comprehensive and clinically actionable framework for the governance of virtual oncology care. RECENT FINDINGS: The pandemic acted as a global catalyst, driving telehealth to over 50% of oncology outpatient encounters in some settings, before stabilising post-pandemic at approximately 10-20% of consultations within hybrid care models. Evidence supports meaningful clinical benefits - improved access to specialist services, reduced travel burden, and sustained continuity of care - with outcomes comparable to in-person care in postoperative follow-up, symptom monitoring, and survivorship. However, persistent disparities in device availability, connectivity, and digital literacy disproportionately affect older, rural, and socioeconomically disadvantaged patients, raising the risk that geographic inequalities are replaced by technological ones. From a medico-legal standpoint, the remote modality does not modify the applicable standard of care, yet restricted physical examination and reliance on patient-reported data introduce risks of diagnostic delay and incomplete clinical assessment, with direct implications for professional liability, data protection under HIPAA and GDPR, cross-border licensure, and multi-party accountability across physicians, institutions, and technology providers. Tele-oncology has become a permanent structural feature of modern cancer care, offering demonstrable benefits in access, continuity, and patient satisfaction. Yet its integration has been uneven, its governance remains fragmented, and its medico-legal landscape is still evolving. Realising the full potential of virtual oncology care - equitably and safely - requires coherent regulatory frameworks, sustained investment in digital infrastructure, and explicit attention to the populations at greatest risk of being left behind.

Humans

Effect of transcutaneous vagus nerve stimulation in hemodialysis patients: A randomized controlled trial.

INTRODUCTION: Transcutaneous auricular vagus nerve stimulation (tVNS) has shown potential in neurological, autoimmune, and cardiovascular disorders, but its effects on HD patients remain unclear. This study aimed to evaluate the efficacy and safety of tVNS in HD patients. METHODS: We conducted a randomized controlled clinical trial on patients receiving HD &#x2265;6&#x2009;months. The tVNS group received stimulation for 1&#x2009;h during the first 2&#x2009;h of HD sessions, three times weekly for 8&#x2009;weeks, while the control group received standard care. The primary outcomes were dialysis efficiency (Single-pool Kt/V, Sp Kt/V) and dialysis-related symptoms (Dialysis Symptom Index, DSI), assessed every 4&#x2009;weeks. Secondary outcomes included pain and fatigue scores, physical performance, Hemodialysis Comfort Scale, hemoglobin levels, Mini-Mental State Examination, and anxiety and depression scores, measured at baseline and 8&#x2009;weeks after intervention. RESULTS: A total of 63 patients were enrolled in the study, with 32 patients assigned to the tVNS group and 31 patients to the control group. At 8&#x2009;weeks, the tVNS group showed significant improvements in Sp Kt/V (1.31&#x2009;&#xb1;&#x2009;0.11 vs. 1.25&#x2009;&#xb1;&#x2009;0.10, p&#x2009;=&#x2009;0.02), and DSI (12.09&#x2009;&#xb1;&#x2009;5.84 vs. 16.26&#x2009;&#xb1;&#x2009;5.27, p&#x2009;=&#x2009;0.004), as well as reductions in pain and fatigue, and increases in physical function, comfort, and hemoglobin. However, there were no statistically significant changes observed in cognitive function, anxiety, or depression. CONCLUSIONS: tVNS could improve dialysis efficiency, symptoms, and physical function in HD patients, indicating it may have a role as a complementary therapy.

Humans

Hydrodissection-assisted laparoscopic orchiopexy utilizing needle grasper for palpable undescended testes: Clinical efficacy analysis.

OBJECTIVE: Laparoscopic orchiopexy has emerged as a viable alternative for the treatment of palpable undescended testis (UDT). This study aims to evaluate the feasibility and efficacy of needle-grasper hydrodissection-assisted laparoscopic orchiopexy (NHLO) in comparison to conventional laparoscopic orchiopexy (CLO) for palpable UDT. METHODS: A cohort of 96 patients diagnosed with palpable UDT, admitted between January 2020 and April 2024, was included in this study. Among these, 54 patients underwent NHLO, while 42 patients were treated with CLO. In the NHLO procedure, normal saline was injected into the retroperitoneal space to create a hydrodissection barrier, facilitating the separation and protection of the vas deferens and spermatic cord. The vas deferens and spermatic cord were meticulously dissected following the principles of integrity and minimal tissue trauma. Outcome measures included final testicular position, testicular volume growth, testicular atrophy, success rate, and postoperative complications. RESULTS: No significant differences were observed between the NHLO and CLO groups in terms of age, laterality, operative time (NHLO: 38-46 min; CLO: 39-48 min), or complication rates (NHLO: 1.9 %; CLO: 0.0 %). At follow-up, all patients in both groups exhibited palpable testes in satisfactory scrotal positions. Notably, no visible abdominal scarring was observed in the NHLO group, whereas there were two noticeable scars on the abdomen in CLO. CONCLUSION: Needle-grasper hydrodissection-assisted laparoscopic orchiopexy is a safe, effective, and minimally invasive technique that provides optimal protection of the vas deferens and spermatic cord while achieving excellent cosmetic outcomes.

Humans

Efficacy and safety of JAK inhibitors in Beh&#xe7;et syndrome: systematic literature review.

OBJECTIVES: Given the active role of the JAK signaling pathway and the multifactorial immune mediators observed in Beh&#xe7;et syndrome (BS), JAK inhibitors (JAKi) may be promising agents. In this systematic literature review (SLR), we aim to evaluate the efficacy and safety of JAKi in BS. METHODS: A systematic literature search was conducted in Embase, PubMed, and the Cochrane Library to identify all reports on the efficacy and safety of JAKi in patients with BS. The SLR protocol was registered with the International Prospective Registry of Systematic Reviews (CRD420251000172). We additionally presented our patient with gastrointestinal involvement treated with upadacitinib. RESULTS: Among the 92 patients (48 men, mean (SD) age 38.5 (13.5) years), 46 used tofacitinib, 31 used baricitinib, and 15 used upadacitinib. All but 1 patient had used at least one previous conventional immunosuppressive, and 57.6% were refractory to at least one prior tumor necrosis factor inhibitor. JAKi were used in combination with conventional immunosuppressive and/or glucocorticoids in 90.6% of the patients. The primary indication for JAKi initiation was gastrointestinal involvement in 46 (50%) patients including our patient, vascular involvement in 22 (23.9%), uveitis in 19 (20.6%), and mucocutaneous and/or articular involvement in 5 (5.6%) patients. The remission rates for overall, gastrointestinal, vascular, and eye involvement were 85.9%, 82.6%, 90.9%, and 84.2%. Serious adverse events were observed in 5.4% of the patients. No thrombotic events were reported. CONCLUSION: This SLR showed that JAKi may be effective in refractory BS patients with a favorable safety profile.

Humans

E-cigarette product characteristics and packaging features and interest in e-cigarette use: Results from a randomized within-person trial nested in three prospective cohorts.

BACKGROUND: Product characteristics and packaging may be key targets for regulation to reduce e-cigarette use among youth, but existing data are limited. METHODS: Data are from an experimental study (2018-2020) nested within three prospective cohorts (age 14-26) in southern California (N&#x2009;=&#x2009;3565). Participants were shown five e-cigarette (e-liquid) packages in a random order that varied in flavor (sweet vs. tobacco), flavor name (descriptive ["blueberry cheesecake"] vs. concept ["smurf cake"] vs. none [number only]), and cartoon image on package (yes/no). For each stimuli, survey items assessed the following outcomes: product appeal (self-enjoyment, others' enjoyment; Likert scale [1-5]), susceptibility to use (use if friends offered, curiosity; 4 ordered responses [definitely not-definitely yes]), peer acceptability (definitely not-definitely yes), and perceived harm (definitely not-definitely yes). Mixed effects proportional odds models evaluated within-person effects of each factor (flavor, flavor name, cartoon) with each outcome. RESULTS: Participants reported greater appeal, susceptibility, and peer acceptability (OR range=3.7-16.9; ps<0.05), and lower perceived harm (OR=0.61; 95%CI=0.53, 0.70) for sweet (vs. tobacco-flavored) e-cigarettes; effects were progressively stronger for younger cohorts. The descriptive flavor name rated higher than the concept flavor (OR range=1.13-2.02; ps<0.05) or number only (OR range=1.18-1.69; ps<0.05) for appeal and susceptibility measures; no differences for concept vs. number were found. The cartoon image rated higher for appeal, curiosity, and peer acceptability (OR range=1.24-1.51; ps<0.05). CONCLUSIONS: Sweet flavors, descriptive flavor names, and cartoon images may increase the appeal of e-cigarettes among youth and young adults with no history of e-cigarette use, and are key targets for regulation.

Humans

Spinal meningiomas: histopathological grading using a benchmark radiomics model with notes on disease control.

OBJECTIVE: Spinal meningiomas (SMs) are common primary spinal tumors for which surgery is considered the first-line treatment when safe and feasible. The ability to extrapolate the tumor grade from preoperative imaging may significantly inform early patient expectation-setting regarding recurrence. Building on radiomics studies in cranial meningiomas, the authors aimed to construct a benchmark radiomics model to preoperatively identify the histological grade of SMs. METHODS: Institutional surgical records from May 2012 to November 2025 were queried for pathology-confirmed meningiomas below the foramen magnum, with preoperative contrast-enhanced imaging available for segmentation. SMs were classified as low-grade (WHO grade 1) and high-grade (WHO grade 2 tumors and grade 1 tumors with atypia). Tumors were manually segmented, and features were extracted using the PyRadiomics software package. An ensemble model of k-nearest neighbors, random forest, and support vector machine classifiers was trained using nested cross-validation on a subset of 10 features to differentiate tumor grades. Clinical data for the cohort were also extracted, and disease control in an adjunctive clinical series was assessed. RESULTS: Seventy-four patients were included in radiomics analysis, with an area under the receiver operating characteristic curve of 0.879 and a mean F1 score of 0.748. The model's top 5 features were all texture features that differed significantly (p < 0.05) across low- and high-grade SMs. These included measures of tumor textural and contrast-enhancement heterogeneity, with overlap with features reported in radiomics models for histological grading of intracranial meningiomas. Fifty-five patients with a median radiographic follow-up of 22.2 (range 1.9-86.4) months remained for clinical analysis after exclusion of patients with less than 1 month of follow-up and syndromic meningiomas. Four recurrences occurred at a median of 20.8 (range 1.8-41.8) months. High-grade tumor pathology did not significantly impact progression-free survival (p = 0.682, log-rank test; Cox regression high vs low grade hazard ratio [HR] 0.62, 95% CI 0.06-6.11, p = 0.685). Subtotal resection was associated with poorer progression-free survival than gross-total resection (p = 0.004, log-rank test; Cox regression subtotal vs gross-total resection HR 10.62, 95% CI 1.46-77.05, p = 0.019). These findings remain contextualized within a relatively limited follow-up window and small recurrence event count, suggesting a need to characterize the interplay between tumor grade and extent of resection as drivers of local disease control in SMs. CONCLUSIONS: A preoperative radiomics model can stratify high-grade SMs using open-source tools applied to single-institution data.

Humans

Association of time-averaged systemic immune-inflammation indices with in-hospital mortality after intracerebral hemorrhage: a retrospective study.

BACKGROUND: Systemic inflammation plays a central role in secondary brain injury following intracerebral hemorrhage (ICH). Although inflammatory indices such as the neutrophil-to-lymphocyte ratio (NLR), systemic immune-inflammation index (SII), and systemic inflammation response index (SIRI) are linked to poor outcomes, their associations with mortality are commonly assumed to be linear, potentially overlooking nonlinear patterns where mortality risk rises steeply at higher levels. METHODS: We conducted a retrospective study using the MIMIC-IV database, including 440 patients with non-traumatic ICH who were alive and remained in the ICU for at least 72&#xa0;h after admission. Mean NLR, SII, and SIRI were calculated from measurements obtained during this period. Multivariable logistic regression and restricted cubic spline (RCS) analyses were applied to assess their independent and nonlinear associations with in-hospital mortality. Model discrimination and calibration were internally validated using 1,000 bootstrap resamples. RESULTS: The in-hospital mortality rate was 26.1%. After multivariable adjustment, NLR and SIRI remained independently associated with mortality. Patients in the highest SIRI quartile had the highest risk of death (aOR&#xa0;=&#xa0;5.12; 95% CI: 2.57-12.24; p&#xa0;<&#xa0;0.001). RCS analysis revealed a significant nonlinear association between SIRI and mortality (p-nonlinearity&#xa0;<&#xa0;0.05), showing a steep risk increase at higher SIRI levels. Adding SIRI to the base model provided a modest improvement in discrimination (AUC 0.762 to 0.785, p&#xa0;=&#xa0;0.045) and significantly improved risk reclassification (cNRI&#xa0;=&#xa0;0.4778, p&#xa0;<&#xa0;0.001; IDI&#xa0;=&#xa0;0.0240, p&#xa0;=&#xa0;0.0151). CONCLUSIONS: Among patients with ICH who met the 72-hour eligibility criterion, higher 72-hour average SIRI was independently associated with in-hospital mortality. As a time-averaged measure, SIRI should be interpreted as a dynamic marker integrating the initial inflammatory state and the early clinical course rather than as a purely baseline prognostic factor. Although adding SIRI to the base model modestly improved discrimination and risk reclassification, it should be considered a candidate prognostic marker requiring external validation before clinical application.

Humans

Depressive Symptoms and Smoking Cessation Among Adolescents and Young Adults Who Smoke: A Prospective Cohort Study.

PURPOSE: This study examined the bidirectional prospective associations between depressive symptoms and smoking cessation among adolescent and young adults who smoke. METHODS: Data on 1,151 participants aged &#x2264;25 years who smoke and receive peer-led quitline counseling in Hong Kong (2016-2022) were analyzed. Exposures included baseline depressive symptoms and smoking cessation (self-reported 7-day abstinence) at 1, 3, and 6 months; Outcome measures included smoking cessation at 1, 3, and 6 months and depressive symptoms at 6 months. Depressive symptoms were assessed using the Center for Epidemiologic Studies Depression Scale, with a score &#x2265;16 indicating at risk for depression. RESULTS: More severe baseline depressive symptoms were associated with lower odds of smoking cessation at 1, 3, and 6 months, which reversely was associated with lower depressive symptoms at 6 months (all p < .05). Similarly, being at risk for depression at baseline was associated with lower odds of smoking cessation at 1 (adjusted odds ratio [aOR] .66, 95% confidential interval [CI] .47-.93) and 3 months (aOR .71, 95% CI .52-.97). Conversely, smoking cessation at 1 (aOR .40, 95% CI .23-.69), 3 (aOR .58, 95% CI .37-.92), and 6 months (aOR .44, 95% CI .29-.69) was associated with lower odds of at risk for depression at 6 months. DISCUSSION: More severe depressive symptoms were prospectively associated with lower odds of smoking cessation, while smoking cessation was associated with lower depressive symptoms and risk for depression. Integrated interventions simultaneously addressing psychological needs and smoking are warranted, when delivered in smoking cessation programs or embedded within mental health services for youth who smoke.

Humans

Artificial Intelligence Technologies in Nursing Clinical Decision-Making: An Umbrella Review.

AIM: To describe contemporary peer-reviewed literature on artificial intelligence in nurses' clinical decision-making. METHODS: An umbrella review of literature reviews. DATA SOURCES: Four major databases were searched for reviews published between 2019 and 2024. RESULTS: Sixteen literature reviews reported on 965 nursing artificial intelligence primary studies. The studies focused on technology development and emerging performance evaluations, whilst real-world testing or implementation in nursing clinical settings was rare. Rigorous comparative analyses were lacking. While artificial intelligence demonstrates promise in decision-making, challenges such as a lack of controlled studies, algorithmic bias, limited reproducibility and insufficient clinical trials hinder its practical impact. Ethical concerns, transparency and patient data privacy issues pose barriers to AI integration in nursing practice. Ethical and legal guidelines for patient privacy are needed and should be taught along with AI literacy training for nurses. CONCLUSIONS: Artificial intelligence has the potential to enhance clinical nursing decision-making, although evidence is limited by too few examples of nurse participation during development. Underutilisation in administrative nursing functions hinders implementation. Nurses should assume a central role in the design and development of AI applications to ensure that these technologies address the realities of nursing practice. With such improvements, artificial intelligence can transform nursing practice, improve nurses' clinical decision-making and ultimately enhance consumer healthcare outcomes. PATIENT OR PUBLIC INVOLVEMENT: No Patient or Public Involvement. REPORTING METHOD: While there is no reporting checklist for umbrella reviews, the PRISMA guide for systematic reviews was followed.

Artificial Intelligence

A Novel Moisturizer Formulated With Micronized Centella asiatica and Mandelic Acid Improves Mature, Crepey Skin.

BACKGROUND: Dermatoporosis is a condition of fragile, aging skin that manifests as altered pH, wrinkles, laxity, easy bruising, and hyperpigmentation. This study evaluated efficacy, safety, and subject perception after the use of a novel cream, GC (Galderma Laboratories, LP, Fort Worth, TX), on subjects with mature, aging skin. METHODS: A 12-week multicenter, randomized, blinded, in-use study enrolled female and male subjects aged 40 to 60 years of all races, ethnicities, and Fitzpatrick skin types. Subjects were required to have a history of fragile skin and dry, crepey skin on the knees and thighs. GC cream was applied to knee and upper thigh skin twice daily. Assessments included clinical grading, digital photography, bioinstrumentation (skin texture, pH, and heatmap hydration), standard safety assessments, and satisfaction. RESULTS: Use of GC cream for 12 weeks resulted in significant improvements in skin crepiness, photodamage, and firmness, as well as decreased skin pH and early improvements in skin roughness and smoothness from baseline. Corneometer heatmapping documented improved skin hydration over baseline. No adverse events were reported; the GC cream was well tolerated, and subjects reported high satisfaction. CONCLUSION: Twice-daily application of the novel GC skin cream significantly improved the overall skin quality of mature, aging skin, including crepiness, photodamage, firmness, texture, pH, and hydration. GC cream was well tolerated with high subject satisfaction. These data are intended to help guide healthcare providers and patients in choosing an effective moisturizer that was specifically designed for patients with fragile, mature skin.

Humans

Effects of permissive hypercapnia on intraoperative cerebral oxygenation and early postoperative cognitive function in older patients with fragile brain function during the non-acute phase undergoing laparoscopic colorectal surgery: A randomized controlled trial.

BACKGROUND AND PURPOSE: Older adults with non-acute fragile brain function (NFBF) may be particularly susceptible to perioperative disturbances in cerebral oxygenation and postoperative neurocognitive decline. Permissive hypercapnia (PHC) may enhance cerebral oxygenation, but its effects in this population remain unclear. We examined whether PHC-based ventilation improves intraoperative regional cerebral oxygen saturation (rSO2) and early postoperative cognitive outcomes in older patients with NFBF undergoing elective laparoscopic colorectal surgery. METHODS: In this single-center, single-blind randomized trial, 76 patients were assigned in a 1:1 ratio to PHC-based or conventional ventilation. The primary outcome was the absolute change in rSO2 from baseline (T0) to the end of surgery (T4). Analyses followed the intention-to-treat principle, with prespecified per-protocol sensitivity analysis. Secondary outcomes included intraoperative rSO2 trajectories, cerebral oxygen extraction-related indices, early postoperative cognitive screening, serum neuron-specific enolase and interleukin-6, and safety outcomes. RESULTS: PHC significantly increased rSO2 relative to conventional ventilation (left: adjusted mean difference [aMD] 10.64, 95% CI 8.96-12.33; right: aMD 10.16, 95% CI 8.22-12.11; both P&#xa0;<&#xa0;0.001), with consistent sensitivity results. Repeated-measures analyses showed persistently higher intraoperative rSO2 in the PHC group. Cerebral oxygen extraction-related indices were generally lower with PHC. However, early postoperative cognitive outcomes and serum biomarkers did not differ between groups. Emergence time was modestly longer with PHC, whereas adverse events were comparable. CONCLUSIONS: PHC-based ventilation favorably modified intraoperative cerebral oxygenation and oxygen-extraction profiles but did not translate into detectable early postoperative cognitive or biomarker benefits in older adults with NFBF.

Humans

A 12-week, double-blind, quasi-randomized, placebo-controlled study to evaluate the efficacy and safety of Coleus forskohlii (Forcslim) on body weight loss.

BACKGROUND: Overweight and obesity have emerged as a global epidemic, significantly impacting human health. Traditional usage and growing scientific evidence suggest that Coleus forskohlii extract (Forcslim) may aid in reducing excess body weight and fat. This study aimed to evaluate the efficacy and safety of Forcslim supplementation in overweight individuals. METHODS: A quasi-randomized, double-blind, placebo-controlled clinical trial was conducted in 60 overweight subjects aged 20-70&#x2009;years over a period of 12&#x2009;weeks. The participants were assigned to receive either Forcslim or placebo. The key outcome measures included body weight, body mass index (BMI), body composition, and anthropometric parameters. Additionally, lipid profile parameters and safety markers (including metabolic, hepatic, and cardiovascular indicators) were assessed throughout the study duration. RESULTS: Compared to the placebo group, the Forcslim group showed significant reductions in waist circumference (-1.83&#x2009;cm; p&#x2009;<&#x2009;0.01) and body weight (-1.93&#x2009;kg; p&#x2009;<&#x2009;0.001). Significant improvements in anthropometric parameters were observed exclusively in the Forcslim group. Furthermore, triglyceride (TG) levels were significantly reduced (p&#x2009;<&#x2009;0.01), while high-density lipoprotein (HDL) levels showed a significant increase (p&#x2009;=&#x2009;0.001). No clinically significant changes were observed in metabolic markers, liver and muscle enzyme levels, heart rate, blood pressure, or reported adverse effects, indicating a favorable safety profile. CONCLUSIONS: Forcslim demonstrated significant anti-obesity effects, including reductions in body weight, waist circumference, and improvements in the lipid profile. These findings suggest that C. forskohlii extract supplementation may serve as a safe and effective alternative to synthetic anti-obesity drugs.

Humans

Potential Links Between Physiological and Perceptual Strain in High Heat Stress.

The physiological strain index (PhSI) is widely used to quantify thermoregulatory and cardiovascular strain during heat stress. However, direct physiological measurements may not always be feasible in occupational or athletic settings. Therefore, this study aimed to examine the relationship and agreement between perceptual strain and integrated physiological strain indices during high heat stress. Ten healthy, physically active, non-heat-acclimated males (29 (7) yr; 1.79 (0.11) m; 77.4 (9.3) kg) completed two randomized crossover exercise trials in hot-dry (HD) and warm-humid (WH) environments with equivalent wet-bulb globe temperatures. Heart rate, rectal temperature, skin temperature, rating of perceived exertion, and thermal sensation were measured at baseline and every 15&#xa0;minutes during 60&#xa0;minutes of cycling. Physiological strain index (PhSI), adaptive physiological strain index (aPhSI), and perceptual strain index (PeSI) were calculated using validated equations. Repeated-measures correlation analyses demonstrated very strong associations between PeSI and both PhSI and aPhSI under HD (Rrm&#xa0;=&#xa0;0.940-0.943) and WH (Rrm&#xa0;=&#xa0;0.980-0.982; all p&#xa0;<&#xa0;0.001). Receiver operating characteristic analyses demonstrated good-to-excellent discrimination of physiological strain by PeSI (AUC&#xa0;=&#xa0;0.895-0.969). Mixed-effects analyses showed that higher PeSI values were associated with increased PhSI (&#x3b2;&#xa0;=&#xa0;1.325, p&#xa0;<&#xa0;0.001) and aPhSI (&#x3b2;&#xa0;=&#xa0;1.459, p&#xa0;<&#xa0;0.001). However, Bland-Altman analyses demonstrated relatively small mean biases (0.4-0.9 AU) but wide limits of agreement (-2.8 to 4.2 AU), indicating that PeSI and physiological strain indices are not interchangeable. These findings suggest that PeSI may serve as a practical adjunctive or screening indicator of physiological strain when direct physiological measurements are unavailable.

Humans

Discrepancies in CPAK classification between CT and long-leg radiography: a systematic review and meta-analysis.

OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. RESULTS: Four studies (1,134 knees) were included. Compared with long-leg radiography-derived classification, CT-derived classification increased type I phenotypes (risk difference: 0.10; 95% confidence interval: 0.01-0.20; P&#x2009;=&#x2009;0.040) and decreased type III (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.020) and type V phenotypes (risk difference: -0.04; 95% confidence interval: -0.07 to -0.01; P&#x2009;=&#x2009;0.004). CT yielded significantly lower medial proximal tibial angle (weighted mean difference:&#x2009;-&#x2009;1.18&#xb0;; P&#x2009;<&#x2009;0.001), arithmetic hip-knee-ankle angle (weighted mean difference:&#x2009;-&#x2009;0.95&#xb0;; P&#x2009;<&#x2009;0.001), and joint line obliquity (weighted mean difference:&#x2009;-&#x2009;1.40&#xb0;; P&#x2009;<&#x2009;0.001) than long-leg radiography. Heterogeneity was high for type I phenotype (I2&#x2009;=&#x2009;81%), lateral distal femoral angle (I2&#x2009;=&#x2009;70%), and joint line obliquity (I2&#x2009;=&#x2009;69%). CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.

Humans