Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ophthalmodynamometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Principles of photometry of the papilla.

To enhance the qualitative information gained by photographing the optic nerve head, we built a silicon photovoltaic detector (photodiode) in the image plane of a fundus camera (Zeiss). It permitted quantitative evaluation of the relative brightness of the illuminated papilla. Following construction of the device and during the early course of more than 260 measurement sessions (on more than 130 subjects), several heretofore unknown sources of error were encountered and subsequently dealt with, resulting in a margin of error for the entire system of between 0.3% and 1.2%. Pallor of the optic nerve head induced by artificial ocular hypertension can be well reproduced by this method.

Humans↗

Noninvasive methods for evaluation of extracranial cerebrovascular disease. A comparison.

Sixty-five patients with clinical evidence of carotid occlusive disease were evaluated by the Doppler ophthalamic test, ophthalmodynamography, and oculopneumoplethysmography prior to angiography. Clinical assessment was accurate 68% of the time, with 32% of patients having no arteriographic evidence of significant disease. The sensitivity of the noninvasive tests was dependent on the extent of the carotid stenosis. When the extent was greater than 60% of the cross-sectional diameter, the Doppler ophthalmic test was accurate 54% of the time; the ophthalmodynamography test, 61% of the time; and the oculopneumoplethysmographic test, 97% of the time. In lesions encompassing 50% to 60% of the vessel diameter, the Doppler ophthalmic test was accurate 15% of the time; the ophthalmodynamography test, 17% of the time; and the oculopneumoplethysmographic test, 10% of the time. With less than 50% stenosis, none of the noninvasive tests detected atherosclerotic lesions. Although many diseased vessels were missed, the low incidence of false-positive tests enhanced the usefulness of these methods in augmenting the accuracy of clinical evaluation.

Carotid Artery Diseases↗

Influence of suction cup oculopression on corneal astigmatism.

In 11 (right) eyes of 11 ocularly healthy subjects an artificial stepwise intraocular pressure (IOP) elevation was applied by suction cup oculopression. The initial negative pressure in the suction cup was 80 mmHg; it was raised in steps of 40 mmHg. The median of the corneal astigmatism, measured with a Zeiss ophthalmometer, was 0.50 D before oculopression (the values of the 10th and 90th percentiles were 0.30 and 1.10 D, respectively). Corneal astigmatism increased to 2.00 (0.00-5.10) D, 2.25 (1.00-5.55) D, 2.63 (0.63-7.00) D, 3.38 (1.88-6.88) D, 3.38 (2.83-7.25) D, and 4.38 (2.85-5.63) D with 80, 120, 160, 200, 240, and 280 mmHg oculopression, respectively. The astigmatism dropped to 0.75 (0.00-2.30) D immediately after removal of the suction cup. Thus, suction cup oculopression not only influenced IOP but also ocular refraction. This is of particular importance since visual evoked potential (VEP) amplitude is to a high degree dependent on refractive changes. This fact has to be considered if changes in VEP amplitude during suction cup oculopression are used as a tolerance test in glaucoma diagnosis.

Adult↗