Cardiac telemetry exercise program.

To train cardiac consultants who interpret electrocardiogram rhythm strips from the field, we designed a series of prerecorded telemetered rhythms and discussions which can be sent into telemetry consoles. The patterns represent cardiac arrhythmias (eg, ventricular tachycardia, complete heart block, etc), as well as equipment problems (loose leads, misplaced leads, etc). We selected and modified some of the patterns of "Arrhythmia Resusci Anne" (Laerdal Medical Corporation), sent these through ambulance radios (to create a tone), recorded the signal on a standard tape recorder and dubbed in the monologue. The physician is asked to interpret the pattern and give instructions to the ambulance attendant. The answers and response times are recorded by the technician running the taped exercise. At the end of the quiz, the rhythms are replayed along with a discussion of each pattern.

Ambulances↗

A role for KH domain proteins (Sam68-like mammalian proteins and quaking proteins) in the post-transcriptional regulation of HIV replication.

Overexpression of Sam68 functionally substitutes for, as well as synergizes with, human immunodeficiency virus type 1 (HIV-1) Rev in RRE (Rev response element)-mediated gene expression and virus replication. In addition, COOH-terminal deletion and/or point mutants of Sam68 exhibit a transdominant negative phenotype for HIV replication. Sam68 is a member of KH domain family that includes SLM-1, SLM-2 (Sam68 like mammalian); and QKI-5, QKI-6, and QKI-7 (mouse quaking) proteins. The objective of this study was to examine the effects of these KH family proteins on RRE- and CTE (constitutive transport element of type-D retrovirus)-mediated transactivation. We now report that SLM-1 and SLM-2 proteins, which are the closest relatives of Sam68, marginally enhanced RRE-mediated transactivation, while QK isoforms that are distant relatives of Sam68 had no effect. Interestingly, these proteins still enhanced the effect of Rev in RRE-mediated gene expression. The increase in chloramphenicol acetyltransferase activity was also reflected at the levels of cytoplasmic RRE-chloramphenicol acetyltransferase mRNAs, indicating that Sam68 and KH proteins may have been involved in the stability or export of unspliced RNA. The increase in Rev activity was sensitive to leptomycin B, but not to olomoucine, indicating that the effect of SLM-1, SLM-2, QKI-5, QKI-6, and QKI-7 is exerted through a CRM-1-dependent mRNA export pathway. Thus, KH family proteins play an important role in the post-transcriptional regulation of HIV.

Adaptor Proteins, Signal Transducing↗

Palpitations and arrhythmias. Separating the benign from the dangerous.

Palpitations are a nonspecific symptom and do not necessarily imply serious heart disease. The vast majority of palpitations are benign. Goals in evaluation include detecting and identifying an arrhythmia, clarifying symptom severity, and defining the extent of underlying heart disease. If palpitations are infrequent and not accompanied by angina, congestive heart failure, or syncope, outpatient transtelephonic monitoring yields useful clinical information in most patients and is more cost-effective than Holter monitoring. Patients with major symptoms require hospitalization for aggressive cardiac evaluation and, possibly, electrophysiologic testing to guide treatment.

Arrhythmias, Cardiac↗

Video streaming into the mainstream.

Changes in Internet technology are making possible the delivery of a richer mixture of media through data streaming. High-quality, dynamic content, such as video and audio, can be incorporated into Websites simply, flexibly and interactively. Technologies such as G3 mobile communication, ADSL, cable and satellites enable new ways of delivering medical services, information and learning. Systems such as Quicktime, Windows Media and Real Video provide reliable data streams as video-on-demand and users can tailor the experience to their own interests. The Learning Development Centre at the University of Portsmouth have used streaming technologies together with e-learning tools such as dynamic HTML, Flash, 3D objects and online assessment successfully to deliver on-line course content in economics and earth science. The Lifesign project--to develop, catalogue and stream health sciences media for teaching--is described and future medical applications are discussed.

Computer-Assisted Instruction↗

Why are complementary DNA strands symmetric?

MOTIVATION: Over sufficiently long windows, complementary strands of DNA tend to have the same base composition. A few reports have indicated that this first-order parity rule extends at higher orders to oligonucleotide composition, at least in some organisms or taxa. However, the scientific literature falls short of providing a comprehensive study of reverse-complement symmetry at multiple orders and across the kingdom of life. It also lacks a characterization of this symmetry and a convincing explanation or clarification of its origin. RESULTS: We develop methods to measure and characterize symmetry at multiple orders, and analyze a wide set of genomes, encompassing single- and double-stranded RNA and DNA viruses, bacteria, archae, mitochondria, and eukaryota. We quantify symmetry at orders 1 to 9 for contiguous sequences and pools of coding and non-coding upstream regions, compare the observed symmetry levels to those predicted by simple statistical models, and factor out the effect of lower-order distributions. We establish the universality and variability range of first-order strand symmetry, as well as of its higher-order extensions, and demonstrate the existence of genuine high-order symmetric constraints. We show that ubiquitous reverse-complement symmetry does not result from a single cause, such as point mutation or recombination, but rather emerges from the combined effects of a wide spectrum of mechanisms operating at multiple orders and length scales.

Base Composition↗

Logistical problems in prehospital thrombolysis.

In this study we compared efficacy and safety of prehospital with in-hospital thrombolytic treatment with anistreplase in patients with acute myocardial infarction (AMI). Three-hundred and fifty patients with chest pain were screened for eligibility by the municipal ambulance staff and/or the general practitioner. Patients were included in the absence of contraindications and if the telephone-transmitted ECG showed AMI. In a 6 month period 16 patients (5%) were eligible, but only seven (2%) were randomized. Age over 70 years, duration of chest pain for longer than 4 h and logistic problems were the major factors responsible for the low inclusion rate. The mean time spent at home with and without the ECG procedure was 38 +/- 14 and 14 +/- 8 min, respectively (P less than 0.001). These results demonstrate that in a medium sized town prehospital delivery of intravenous thrombolytic therapy by paramedics and/or the general practitioner is not feasible, leads to unnecessary time delay and may therefore yield no clinical benefits.

Adult↗

The use of slow-scan video for CME in a remote area.

Since August 1977 a slow-scan video system has been operating in a remote area of northwestern Ontario, Canada. This system, using regular dial-up telephone lines, interconnects the local hospital, five remote communities, and two teaching hospitals in Toronto, 1,000 miles distant. Since August 1978 the system has been used on a regular basis for continuing medical education programs, graduate medical education including X-ray rounds, medical rounds, nursing rounds, in-service education, and patient education. These CME programs for physicians have been accepted for study credits by the College of Family Physicians of Canada.

Education, Medical, Continuing↗

Economic analysis of an automated billing system for physicians' services.

An on-line Medicaid billing system for physicians' services was implemented and tested during a two and one-half year period in 100 offices throughout the State of +0.50,Alabama. Participating physicians represented 17% of all physicians in the state. The monthly volume of Medicaid claims entered through the system represented more than 50% of the statewide load processed by the Medicaid carrier. Users entered claims data on standard Touch Tone telephones equipped with Carddialers, and received instructions and data confirmation from the central computer facility via voice answer-back. Input time for the average claim billing for two separate services was less than one and one-half minutes and resulted in a reduction of clerical labor required for manual input by at least 50%. After a fee-for-service was inaugurated, the system workload remained at 86% of its load level before fee for service. Those physicians willing to pay for the billing service were high-volume users who had come to depend on the system and who appreciated the economics that the system had achieved for them in their office billing practices. An average claim consisting of two items of service could be billed at a cost of $0.50,, exclusive of user terminal rental ($6 per month per office) and the cost of data entry personnel (between $0.05 and $0.10 + 0.05 and $.10 per claim). Various algorithms have been offered for use in estimating an annual budget for an on-line billing system given alternative system configurations, methods of financing, annual volume of units of service, and the geographical nature of the population to be served. The tasks of preparing, processing, and storing insurance claims information have placed a costly and time-consuming burden on both providers of medical services and fiscal intermediaries. The unfortunate result is that the cost of submitting an insurance claim for professional medical services is a disproportionate fraction of the amount paid for providing the service. For general practitioners, who provide the largest number of individual services, this share may be more than one-fourth of the payment for most common services. Similarly, for the Medicaid or Medicare intermediary or for the insurance carrier, the cost of preparing and recording data from source documents is a large part of total processing costs. The objective of the On-Line Medicaid Billing System project was to demonstrate that it is possible to reduce the costs of submitting claims from the physician's office as well as to reduce the costs of data preparation in the carrier's system. This publication focuses on an economic analysis of cost effectiveness. Readers interested in system design, development, and on-line operation will find detailed descriptions in previously published reports.

Accounting↗

Multichannel physiological monitor plus simultaneous full-duplex speech channel using a dial-up telephone line.

Because of bandwidth limitations, the Public Switched Telephone Network (PSTN) cannot normally accommodate simultaneous multichannel physiological signaling with speech. This communication describes work carried out to build a physiological monitoring system which can transmit up to six low-frequency data channels in the presence of a full-duplex speech channel using one telephone line.

Electrocardiography↗

Fetal heart rate monitoring by telephone. I. Development of an integrated system in Cardiff.

We report the development of a practical dedicated system for domiciliary fetal monitoring integrated in a scheme for its rational application. From experience of 1120 domiciliary recordings in 74 women (64 with high-risk pregnancies), we suggest that domiciliary monitoring applied within a structured clinical context should be as safe as monitoring in hospital.

Female↗

Fetal heart rate monitoring by telephone. II. Clinical experience in four centres with a commercially produced system.

A commercially produced domiciliary fetal monitoring (DFM) system was assessed in four centres in the UK (Bristol, Glasgow, London and Nottingham) chosen to allow for comprehensive assessment in various settings in many different women. Overall, 825 recordings were made from 368 women (2.24 per woman). There were 56 unsuccessful attempts at transmission (6.8%), most were due to problems with telephone equipment. The system worked most efficiently when a dedicated direct line was used. The data transmission time varied between 40 and 60 s. The median telephone time (including data transmission and conversation) with a dedicated direct line was 7 min. Mean acceptance times from the four centres were between 70 and 80%. All recordings with acceptance times of 40% or more were interpretable. Ten recordings were abnormal. The women and mid-wives were equally proficient at using the DFM system. The DFM system represents an important addition to current methods of fetal assessment. Specific guidelines are outlined.

England↗