Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MIRRORS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

The neural basis of visual skill learning: an fMRI study of mirror reading.

The learning of perceptual skills is thought to rely upon multiple regions in the cerebral cortex, but imaging studies have not yet provided evidence about the changes in neural activity that accompany visual skill learning. Functional magnetic resonance imaging (fMRI) was used to examine changes in activation of posterior brain regions associated with the acquisition of mirror-reading skill for novel and practiced stimuli. Multiple regions in the occipital lobe, inferior temporal cortex, superior parietal cortex and cerebellum were involved in the reading of mirror-reversed compared to normally oriented text. For novel stimuli, skilled mirror-reading was associated with decreased activation in the right superior parietal cortex and posterior occipital regions and increased activation in the left inferior temporal lobe. These results suggest that learning to read mirror-reversed text involves a progression from visuospatial transformation to direct recognition of transformed letters. Reading practiced, relative to unpracticed, stimuli was associated with decreased activation in occipital visual cortices, inferior temporal cortex and superior parietal cortex and increased activation in occipito-parietal and lateral temporal regions. By examining skill learning and item-specific repetition priming in the same task, this study demonstrates that both of these forms of learning exhibit shifts in the set of neural structures that contribute to performance.

Brain↗

Electrostatic mirror objective with eliminated spherical and axial chromatic aberrations.

Computational formulae for the coefficients of the third-order spherical aberration and the second-order axial chromatic aberration are presented for an axially symmetric electrostatic electron mirror. A technique for eliminating the high-order derivatives of the potential axial distribution in mirror systems from the integrands is described. Conditions for elimination of spherical and axial chromatic aberrations, either separately or simultaneously, are found for a three-electrode axially symmetric mirror composed of coaxial cylinders of the same diameter. A principal scheme of the transmission electron microscope, where an electrostatic electron mirror serves as its objective, is presented.

Journal Article↗

"The mirror" and "the village": a new method for teaching practice-based learning and improvement and systems-based practice.

PURPOSE: Practice-based learning and improvement (PBLI) and systems-based practice (SBP) may be conceptually difficult for both residents and faculty. Methods for introducing these concepts are needed if PBLI and SBP are to be incorporated into education and practice. METHOD: In 2001, PBLI and SBP were introduced at Johns Hopkins Bayview Medical Center in Baltimore, Maryland, using the metaphors "the mirror" and "the village." PBLI was likened to residents' holding up a mirror to document, assess, and improve their practice. Specific tools for residents (e.g., weekly morbidity and mortality morning reports, continuity clinic chart self-audits, and resident learning portfolios) became the mirrors. SBP was introduced through specific training activities (e.g., multidisciplinary patient care rounds, nursing evaluations, and quality assessment-systems improvement exercises) using the metaphor of the village made famous by Hillary Clinton in the phrase: "It takes a village to raise a child." Residents completed a questionnaire in which they rated these initiatives' impact on their training. RESULTS: The majority of residents who participated in specific activities agreed that quality assessment-systems improvement exercises (92.9%), multidisciplinary rounds (92.1%), morbidity and mortality morning reports (86.8%), clinic chart self-audits (76.4%), and nursing evaluations (52.8%) helped to improve their proficiency in specific aspects of PBLI and SBP. Residents' retrospective self-assessments of their PBLI abilities demonstrated significant improvement after the introduction of specific training activities. CONCLUSIONS: PBLI and SBP can be introduced effectively in residency training by incorporating specific activities that use the metaphors of the mirror and the village.

Baltimore↗

Acute stroke effects on emotions: an interpretation through the mirror system.

PURPOSE OF REVIEW: The most recent reports on emotional consequences of stroke are hereby reviewed and analyzed. In particular the interpretation of some neurological presentations found in stroke patients, such as athymormia, dysprosody, emotional incontinence and emotional blunting is discussed. As current theories on mental functions do not provide satisfactory explanations for the above syndromes, a novel interpretative framework is proposed, based on neuropsychological experimental data on the 'mirror system'. RECENT FINDINGS: Recent findings support both the fundamental role of the mirror system in imitative processes as well as the relevance of imitation for the emotional part of human personality and behavior. SUMMARY: The mirror system appears to be of paramount relevance for empathy and social behavior. The model of analysis-by-synthesis is here discussed, together with neurological presentations resulting from stroke induced impairments of the mirror system. Speculations for further researches are also proposed.

Affect↗

Spontaneous resolution of mirror syndrome.

BACKGROUND: Mirror syndrome, a rare condition characterized by maternal anasarca in a pregnancy complicated by fetal hydrops, may have a devastating fetal outcome and significant maternal morbidity. CASE: We report a case of mirror syndrome caused by parvovirus B19 infection, which resolved spontaneously with good fetal and maternal outcome. CONCLUSION: The pathogenesis of mirror syndrome is not understood. The trigger for mirror syndrome may be derived from a compromised fetus or placenta.

Adult↗

Complete characterization of a plasma mirror for the production of high-contrast ultraintense laser pulses.

Improving the temporal contrast of ultrashort and ultraintense laser pulses is a major technical issue for high-field experiments. This can be achieved using a so-called "plasma mirror." We present a detailed experimental and theoretical study of the plasma mirror that allows us to quantitatively assess the performances of this system. Our experimental results include time-resolved measurements of the plasma mirror reflectivity, and of the phase distortions it induces on the reflected beam. Using an antireflection coated plate as a target, an improvement of the contrast ratio by more than two orders of magnitude can be achieved with a single plasma mirror. We demonstrate that this system is very robust against changes in the pulse fluence and imperfections of the beam spatial profile, which is essential for applications.

Journal Article↗

Mirror fluid method for numerical simulation of sedimentation of a solid particle in a Newtonian fluid.

The mirror fluid method is proposed for simulating solid-fluid two-phase flow. The whole computational domain is modeled as an Eulerian one for the fluid with a Lagrangian subdomain embedded in it. The boundary condition is enforced implicitly on solid-fluid surface segments by mirror relations. Thus, the total flow is solved in the one domain, in which the solid particle region is replaced with the virtual flow as the mirror image of outside flow. The mirror fluid method is implemented to compute the motion of a rigid spherical or elliptic particle in a Newtonian fluid for the purpose of method validation. The control volume formulation with the SIMPLE algorithm incorporated is used to solve the governing equations on a staggered grid in a two-dimensional coordinate system. A number of numerical experiments on falling particles are performed and the computational results are in good agreement with the reported experimental data.

Journal Article↗

Vacuum-field level shifts in a single trapped ion mediated by a single distant mirror.

A distant mirror leads to a vacuum-induced level shift in a laser-excited atom. This effect has been measured with a single mirror 25 cm away from a single, trapped barium ion. This dispersive action is the counterpart to the mirror's dissipative effect, which has been shown earlier to effect a change in the ion's spontaneous decay [Nature (London) 413, 495 (2001)]]. The experimental data are well described by eight-level optical Bloch equations which are amended to take into account the presence of the mirror according to the model in Phys. Rev. A 66, 023816 (2002)]. Observed deviations from simple dispersive behavior are attributed to multilevel effects.

Journal Article↗

Relation between proton and neutron asymptotic normalization coefficients for light mirror nuclei and its relevance to nuclear astrophysics.

We show how the charge symmetry of strong interactions can be used to relate the proton and neutron asymptotic normalization coefficients (ANCs) of the one-nucleon overlap integrals for light mirror nuclei. This relation extends to the case of real proton decay where the mirror analog is a virtual neutron decay of a loosely bound state. In this case, a link is obtained between the proton width and the squared ANC of the mirror neutron state. The relation between mirror overlaps can be used to study astrophysically relevant proton capture reactions based on information obtained from transfer reactions with stable beams.

Journal Article↗

Design of and metrological results from a bent parabolic mirror.

This article describes the successful design and fabrication of, and metrological results from, an elastically bent parabolic mirror. The mirror is equipped with a bending structure that allows the mirror to be bent meridionally to a parabolic shape. This bent parabolic mirror is the key component of the extremely high-quality monochromators designed for the SPring-8 figure-8 soft X-ray undulator and the 2.0 GeV high-brilliance synchrotron radiation source (VSX).

Journal Article↗

The role of maternal affect mirroring on social expectancies in three-month-old infants.

The role of maternal affect mirroring on the development of prosocial behaviors and social expectancies was assessed in forty-one 2- to 3-month-old infants. Prosocial behavior was characterized as infants' positive behavior and increased attention toward their mothers. Social expectancies were defined as infants' expectancy for affective sharing. Mothers and infants were observed twice, approximately 1 week apart. During Visit 1, mothers and infants were videotaped while interacting over television monitors for 3 min. During Visit 2, infants engaged in a live, 3-min interaction with their mothers over television monitors (live condition) and they also viewed a replay of their mothers' interaction from the preceding week (replay condition). The order of conditions was counterbalanced. Maternal affect mirroring was measured according to the level of attention maintenance, warm sensitivity, and social responsiveness displayed. A natural split was observed with 58% of the mothers ranking high and 42% ranking low on these affect mirroring measures (HAM and LAM, respectively). Infants in the HAM group ranked high on prosocial behaviors and social expectancy--they discriminated between live and replay, conditions with smiles, vocalizations, and gazes. Infants in the LAM group ranked low on these variables--they gazed longer during the live condition than during the replay condition, but only when the live condition was presented first; however, they did not smile or vocalize more. These findings indicate that there is a relation between affect mirroring and social expectancies in infants.

Adult↗

Patients' reactions to a two-way mirror in general practice.

From a survey of 200 patients in two general practices it would appear that the patients' reaction to the use of a two-way mirror is on the whole not unfavourable. The results suggest, however, that in the very personal setting expected of general practice people suffering from psychiatric problems (especially depression) should be given every opportunity to decline consultation in front of the mirror and if any patient becomes upset, then the mirror should be 'turned off' immediately. Internal examinations should not take place when the mirror is in use.

Attitude↗

Retinal imaging with a low-cost micromachined membrane deformable mirror.

PURPOSE: To study the retina in normal subjects with a high-resolution imaging system using adaptive optics for wave front aberration correction. METHODS: We used a low-cost 37-element micromachined membrane deformable mirror (MMDM) with a continuous membrane as the reflective surface. A Hartmann-Shack wave front sensor with cooled charge coupled device camera was used to measure the wave front aberration. Zernike polynomials were used to describe the wave front shape. We developed a mirror control system to compensate for wave aberrations. We tested this instrument in normal subjects. RESULTS: We were able to image the retina in monochromatic laser light and document the increase in resolution. While it is hard to estimate the exact size of the smallest structures in the image, we were able to subjectively grade the image quality. The system is able to compensate for higher order aberrations present in the human eye. CONCLUSION: The capabilities of correcting ocular aberrations are limited by the number of adjustable elements in the mirror and the deflection range of the surface. The advantage of the MMDM system is its low cost when compared with other adaptive optics solutions such as piezodriven mirrors and spatial light modulators. This technique may allow for improved resolution for clinical fundus photography.

Adult↗

A double mirror W/C multilayer monochromator for radiation biology applications.

A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C and a bilayer spacing of d = 3.0 nm are sputter deposited on Si substrates. By proper masking of the sputtering sources, variation in the bilayer spacing over the area of the mirror is minimized. The uniformity of the bilayer spacing was measured to be delta d/d < 1%, over the 75 mm x 25 mm area of the mirrors. The reflectivity was measured as a function of energy to determine the integrated reflectivity and evaluate the contribution of the specular reflection and higher orders to the monochromatic beam. The use of suitable filters with a Si(Li) detector allows determination of the spectral output of the monochromator. The output power of the monochromator between 270 and 2400 eV is measured. The resolution of the monochromator is delta lambda/lambda = 0.04. Applications of the monochromator to radiation biology are discussed.

Cells, Cultured↗

Mirror-image confusion in single neurons of the macaque inferotemporal cortex.

Humans and animals confuse lateral mirror images, such as the letters "b" and "d," more often than vertical mirror images, such as the letters "b" and "p." Experiments were performed to find a neural correlate of this phenomenon. Visually responsive pattern-selective neurons in the inferotemporal cortex of macaque monkeys responded more similarly to members of a lateral mirror-image pair than to members of a vertical mirror-image pair. The phenomenon developed within 20 milliseconds of the onset of the visual response and persisted to its end. It occurred during presentation of stimuli both at the fovea and in the periphery.

Animals↗

The Golden Mirror in the imperial court of the Qianlong emperor, 1739-1742.

In the last month of 1739, the third f the Manchu rulers, the Qianlong emperor (r. 1736-1795), ordered the compilation of a treatise on medicine "to rectify medical knowledge" throughout the empire. By the end of 1742, eighty participants chosen from several offices within the palace bureaucracy based in Beijing completed the Golden Mirror of the Orthodox Lineage of Medicine, the only imperially commissioned medical text the Qing government's Imperial Printing Office published. The Golden Mirror represents both the limitations in the power of the Qianlong emperor and the dominance in the Manchu court of Chinese scholarship from the Jiangnan region during the first decade of his reign. Chinese scholars participating in the compilation of the Golden Mirror fashioned a medical orthodoxy for the empire in the mid-eighteenth century from regional trends since the sixteenth century. The Golden Mirror is an illuminating example of how medical scholars participated in the formation of evidential scholarship in early-modern China and why Manchu patronage, southern Chinese scholarship, and medical orthodoxy, coalesced in the imperial court of the Qianlong emperor.

Awards and Prizes↗

Optic disc measurements with the 78 diopter lens, Zeiss 4-mirror contact lens and computerized image analysing system.

We evaluated the 78 diopter (D) lens and Zeiss 4-mirror lens for the measurement of vertical and horizontal optic disc diameters during slit-lamp biomicroscopy and compared the results with the measurements made with the computerized image analysing system (IMAGEnet 640, Topcon, Japan) in 30 eyes of 30 patients. The 78D lens and Zeiss 4-mirror lens measurements both correlated well with the computerized image analysis measurements (r=0.881 for vertical and r=0.895 for horizontal disc diameter measurements with the 78D lens and r=0.883 for vertical and r=0.891 for horizontal disc diameter measurements with the Zeiss 4-mirror lens). The 78D lens measurements overestimated vertical disc diameter by 5.3% and horizontal disc diameter by 4.4%. The Zeiss 4-mirror lens underestimated the vertical disc diameter by 2.4% and horizontal disc diameter by 2.2%. Thus either lens can be used for a quick estimation of the optic disc size, since the results correlate well with the computerized image analysis measurements.

Contact Lenses↗

Doing it with mirrors: a case study of a novel approach to neurorehabilitation.

Arm amputees can experience the perception of movement of a phantom limb while looking at a mirror reflection of the moving, intact arm superimposed on the perceived phantom. Such use of a mirror to provide illusory visual feedback of movement can be useful in rehabilitation of hemiparetic patients. In this case report, we describe the successful application of "mirror therapy" to the post-stroke rehabilitation of a patient with poor functional use of an upper extremity, due mainly to somatosensory deficits. Mirror therapy facilitated employment of a motor copy strategy (bimanual movements) and later progression to "forced use" of the affected arm. The end result was increased functional use of the affected upper limb.

Arm↗