Blood-brain barrier alteration after microwave-induced hyperthermia is purely a thermal effect: I. Temperature and power measurements.

The effect of microwave-induced hyperthermia on the blood-brain barrier was studied in 21 Sprague-Dawley rats. Under sodium pentobarbital anesthesia, animals were place in a stereotactic frame, and an interstitial microwave antenna operating at 2450 MHz was inserted in a bony groove drilled parallel to the sagittal suture. Some antennae were equipped with an external cooling jacket. Temperature measurements were made lateral to the antenna by fluoroptical thermometry, and power was calculated from the time-temperature profile. Five minutes prior to termination of microwave irradiation, horseradish peroxidase (1 mg/20 g body weight) was injected intravenously. Extravasation of horseradish peroxidase was observed in brain tissue heated above 44.3 degrees C for 30 minutes and at 42.5 degrees C for 60 minutes. Microwave irradiation failed to open the blood-brain barrier when brain temperatures were sustained below 40.3 degrees C by the cooling system. Extravasation of blood-borne peroxidase occurred at sites of maximal temperature elevation, even when these did not coincide with the site of maximum power density. The data suggest that microwave-induced hyperthermia is an effective means for opening the blood-brain barrier and that the mechanism is not related to the nonthermal effect of microwaves.

Animals↗

Microwave: practical cost-effective method for sterilizing urinary catheters in the home.

We used a standard microwave oven to sterilize red rubber catheters used for intermittent self-catheterization. Catheters were incubated for sixty minutes in a suspension of microorganisms isolated from the urine of patients with urinary tract infections. For each trial, 6 catheters were removed from their respective suspensions, placed in separate plastic freezer bags, distributed evenly in a microwave oven (avoiding cold spots), and microwaved simultaneously for twelve minutes. A control catheter was not microwaved. Two strains of each microorganism were tested. The urinary isolates were Escherichia coli, Klebsiella sp., Proteus sp., Enterobacter sp., Pseudomonas sp., Streptococcus sp., Staphylococcus sp., and Candida sp. In each experiment, all 6 catheters were sterilized. Repeat sterilization in the microwave oven did not affect the integrity of the catheters or the plastic bags. A water heat sink of constant volume was employed. A home microwave oven may be used as a method to sterilize red rubber catheters for reuse with a recommended time of twelve minutes at full power. This technique makes aseptic intermittent self-catheterization a practical possibility.

Bacteriuria↗

Microwave treatment of xenogeneic cartilage transplants.

Human rib cartilage was irradiated with microwaves according to six different methods and transplanted into rabbits. Untreated rib cartilage preserved in Cialit served as a control. After 12 and 40 wk of implantation, the microscopic appearance of these xenogeneic cartilage transplants was given a score in comparison with the transplants preserved in Cialit. The microwave treatment of the cartilage appeared to improve the results. The Cialit-preserved transplants showed progressive resorption by macrophages with central necrosis and fragmentation, which was not present in the microwave-treated grafts. Microwaves seem to stabilize the cartilage matrix and enhance the diffusion of fixatives. Irradiation in ethanol as an immersion fluid appeared to be the best method. The results of transplantation can benefit from the use of microwaves in the preservation of the cartilage. It is argued that, in addition, microwave irradiation might be used for inactivation of human immunodeficiency virus in human cartilage used for transplantation.

Animals↗

A novel method for the study of fluorescent probes in biological material during exposure to microwave radiation.

Instrumentation has been developed which allows the monitoring of fluorescence in erythrocyte ghost membranes before, during, and after exposure to microwave radiation. Using non-fluorescent, UV-transmitting fiber optic cables, excitation light of specific wavelengths was delivered to a stirred sample undergoing irradiation (2450 MHz, CW) within a fluid-filled, temperature-controlled waveguide. Fluorescence was collected using an identical cable and transferred through appropriate filters to standard detecting, amplification and recording devices. We have used the fluorescent probe, 1-anilino-8-naphthalene sulfonate (ANS) to monitor the effect of microwave radiation on the binding of calcium to erythrocyte ghosts. Microwave radiation at specific absorption rates of 10 and 200 mW/g had no effect on the binding of ANS to the membranes. Dose-response curves also showed no influence of microwaves on calcium binding between 2.0 and 10.0 x 10(-4) M. In addition, experiments studying fluorescence energy transfer between intrinsic tryptophan residues and membrane bound ANS showed that intermolecular distances between donor and acceptor are also unaffected by microwave radiation. We have thus shown that 2450 MHz microwave radiation at the specific absorption rates used does not interfere with the binding of calcium to erythrocyte ghosts or alter intermolecular distances between intrinsic molecules and bound ANS.

Anilino Naphthalenesulfonates↗

Programming the microwave oven.

Microwaves can be used to stimulate chemical bonding, diffusion of reagents into and out of the specimen, and coagulation processes in preparatory techniques. Temperature plays an important role in these processes. There are several ways of controlling the temperature of microwave-exposed tissue, fluids and solids that are used in these preparatory techniques. In this paper we describe our accumulated experience with monitoring and controlling microwave-oven parameters with the help of a personal computer (PC). A specially designed microwave oven was used with an advanced temperature probe. The oven was connected to an IBM-compatible PC. This enabled us to analyze the quality of temperature control, and the relationship between displayed and actual temperature. We show that for microwave-transparent materials the addition of a microwave-absorbent plate to the material results in better temperature control.

Ethanol↗

Preservation of myelinated fibers for electron microscopy: a qualitative comparison of aldehyde fixation, microwave stabilisation and other procedures all completed by osmication.

A qualitative comparison was made of a variety of electron microscopic preservation methods for nervous tissue, especially with respect to myelinated fiber areas. The methods studied were aldehyde perfusion/immersion fixation, aldehyde-tannic acid immersion fixation (stimulated by either microwave or conventional heating), microwave stabilisation, saline treatment with conventional heating (all with secondary osmication), and primary osmication. For all methods three morphological aspects, the ultrastructural quality of myelin sheath and axon and the coherence between the two were judged separately. It appears that the best version of each method studied is capable of providing a good overall ultrastructural result but always shows a preference for one or two of the three separate morphological aspects. When aiming at good axon quality together with good axon/myelin coherence, aldehyde perfusion/immersion, saline treatment or primary osmication are almost equivalent. Microwave stabilisation, on the other hand, can be chosen when good myelin quality has to be combined with good axon quality. For more specific purposes the following examples can be given. When excellent myelin quality is needed both microwave-stimulated aldehyde-tannic acid fixation or microwave stabilisation can be considered. When the preservation of the axon quality has priority the aldehyde-perfused tissue should be further immersed in a heated aldehyde-tannic acid solution. Primary osmication guarantees excellent axon/myelin coherence. Despite the differences in detail, a remarkable correspondence is stressed between the overall results of sometimes extremely different methods of tissue preservation. Probably they all guarantee a reliable reflection of the in vivo situation. With respect to the use of microwave irradiation for tissue preservation, it appeared that stabilisation procedures are rather capricious. However, if successful, the results are not inferior to those of aldehyde fixation.

Aldehydes↗

An evaluation of the mutagenic, carcinogenic and teratogenic potential of microwaves.

A notable proportion of the population is exposed to an increasing number of devices emitting microwaves, a form of non-ionizing electromagnetic radiation in the range 300-30000 mHz. The activation energy of microwave radiations is too small to directly modify any chemical bonds in the irradiated matter. At microwave frequencies the macroscopic dielectric properties of tissues are strongly determined by their water content. Tissues like muscle, brain, skin, with a high water content, have higher permittivity and conductivity values than bone or fat with low water contents. Owing to the energy transfer, to living tissues, by a dipolar relaxation mechanism of water molecules, the penetration of microwaves is limited and one observes a fast and very efficient heat-loss production. A review of the available literature shows that most results on the mutagenicity of microwaves are negative or can often be explained by a temperature enhancement. If microwaves are apparently unable to damage DNA at sub-thermal exposure levels, some results indicate, however, that they might easily potentiate the damaging action of other DNA antagonist agents such as UV or chemicals.

Animals↗

Dimensional stability of denture bases following repair with microwave resin.

The dimensional stability of a commercially available acrylic resin, designed specifically for polymerization by microwave irradiation, was compared with that of a conventional water-bath-cured resin. Resin bases were processed on duplicate stone casts prepared from a cobalt chromium master die. Twenty bases were polymerized, using acrylic resin modified for rapid heat curing, in a water-bath at 100 degrees C for 22 min. A further 20 bases were polymerized using a microwave curing acrylic resin, in a conventional microwave oven at 500 W power output for 3 min. Ten bases from each group were sectioned in a parasagittal direction and repaired using the microwave curing resin. Following each curing cycle the fit of the posterior border of each base was evaluated via a silicone index formed between the base and the master die. The index was invested in stone and sectioned through the posterior palatal region to allow measurement of its thickness by means of an eyepiece micrometer. One-way analysis of variance and unpaired Student's t tests were employed to compare the differences in distortion at the initial cure and following repair. No significant differences were found in the distortion of the acrylic resin bases produced from the heat-cured or microwave-cured materials. All bases exhibited significant further distortion on repair with the microwave-cured acrylic resin.

Analysis of Variance↗

Extraction of selected drugs from serum using microwave irradiation.

Microwave irradiation is used as an alternative heating method for extraction over more conventional hot plate methods. We describe a fast, efficient method for the determination of selected drugs in human blood/serum using microwave extraction. The microwave extraction of organic substances requires special instrumentation and the results have been compared with the results from classical liquid/liquid extraction. The present microwave extractions were performed in an 'atmospheric pressure' system. Before irradiation with microwaves, an appropriate solvent mixture was added to the buffered specimen. Lidocaine, methadone, diazepam, nordiazepam, propoxyphene and norpropoxyphene were tested as model substances. The quantitation was performed by GC/NPD. The procedure has been applied successfully to a number of forensic cases. The use of microwaves decreases the time of extraction and the solvent consumption.

Analgesics↗

The effect of microwave irradiation on enzymatic hydrolysis of rice straw.

A series of experiments involving microwave irradiation were carried out to evaluate the effect of microwave irradiation on enzymatic hydrolysis of rice straw. Compared with microwave irradiation free hydrolysis, rice straw pretreated by combining microwave irradiation with alkali could increase the initial hydrolysis rate but the hydrolysis yield remained unchanged. When the enzyme solution was treated by microwave irradiation, the initial hydrolysis rate increased slightly, but the yield was decreased remarkably. Its optimal hydrolysis conditions were temperature (45 degrees C), pH (4.8) and enzyme loading (20 mg g(-1) substrate), which was determined by an orthogonal experiment. When intermittent microwave irradiation was used, initial hydrolysis rate was greatly accelerated but the yield was decreased slightly. Its optimal hydrolysis conditions were temperature (50 degrees C), pH (4.8) and enzyme loading (20 mg g(-1) substrate), which was determined by another orthogonal experiment.

Carbohydrates↗

Preparation of low-molecular-weight and high-sulfate-content chitosans under microwave radiation and their potential antioxidant activity in vitro.

In the present paper microwave radiation has been used to introduce N-sulfo and O-sulfo groups into chitosan with a high degree of substitution and low-molecular weight. The sulfation of chitosan was performed in microwave ovens. It was found that microwave heating is a convenient way to obtain a wide range of products of different degrees of substitution and molecular weight only by changing reaction time or/and radiation power. Moreover, microwave radiation accelerated the degradation of sulfated chitosan, and the molecular weight of sulfated chitosan was considerably lower than that obtained by traditional heating. There are no differences in the chemical structure of sulfated chitosan obtained by microwave and by conventional technology. FTIR and 13C NMR spectral analyses demonstrated that a significantly shorter time is required to obtain a satisfactory degree of substitution and molecular weight by microwave radiation than by conventional technology. In this present paper, we also determined antioxidant activity of low-molecular-weight and high-sulfate-content chitosans (LCTS). The results showed LCTS could scavenge superoxide and hydroxyl radical. Its IC50 is 0.025 and 1.32 mg/mL, respectively. It is a potential antioxidant in vitro.

Antioxidants↗

Low power microwave interaction with phospholipase C and D signal transduction pathways in myogenic cells.

Ionic channel proteins are possible sites of microwave interaction at the cell membrane level. Patch-clamp data, using single channel and total current recording, indicated that low level microwave fields may modify some functional parameters of the nicotinic acetylcholine receptor in primary chick myotubes, suggesting a possible effect of microwaves on myogenic cells. Here, we investigated the biological relevance of such results, in relation to the possible involvement of intracellular signaling processes. We exposed L6-C5 myogenic cells to low power electromagnetic fields and observed the consequences on hormonal activation of phospholipases C and D. We found that increased inositol phospholipid turnover, induced by acetylcholine and arginine vasopressin activation of phospholipase C, was not modified in microwave irradiated myoblasts or myotubes. Moreover, vasopressin-dependent phospholipase D activation, assessed by measuring the [3H]-free choline release, was not modified by microwave irradiation. Our conclusions suggest that low level microwave fields do not modify signal transduction pathways activated by acetylcholine and vasopressin in L6-C5 myogenic cells.

Animals↗

The physical and antimicrobial effects of microwave heating and alcohol immersion on catheters that are reused for clean intermittent catheterisation.

INTRODUCTION: Due to worldwide different health insurance policies, patients are often forced to reuse the catheters when performing Clean Intermittent Catheterisation (CIC). We have compared the physical qualities and the antimicrobial effects of two methods of reusing catheters: microwave heating and storage of the catheters in a 70% alcohol solution. The studies were performed during different lengths of time. MATERIALS AND METHODS: Three types of catheters (a standard polyvinylchloride catheter, a special polyvinylchloride catheter with flexible Ergothan tip and a prelubrified catheter), normally intended for single use, were submitted to the effect of a microwave oven (Multitech 215 High Grade and Whirlpool M220 750 W and 1000 W with rotating plate) or preservation in a 70% alcohol solution. To study the effects of microwave heating, a recipient of water was placed in the oven to spread the microwaves and to absorb the heat. The catheters were placed in a resealable plastic bag (Ziploc. To study the effects of preservation in a 70% alcohol solution, the catheters were immerged in the solution for different lengths of time. Thereafter were the physical qualities of the catheters evaluated by using the technique of Differential Scanning Calorimetry (DSC). The antimicrobial effect of the method was evaluated after grafting the catheters with pathogenic E. coli, P. aeruginosa or S. aureus strains. RESULTS: Microwave heating up to 12 minutes at 750 W caused only minimal changes in the physical qualities of all the catheters. However, there was only an antimicrobial effect of the microwave heating on E. coli and not on P. aeruginosa or S. aureus. If the catheter remained longer than 45 minutes in a 70% alcohol solution, the physical qualities of the catheter changed either minimal in the special polyvinylchloride catheter with flexible Ergothan top but changed significantly in the prelubrified catheter). However, already after 5 minutes of immersion in the 70% alcohol solution there was a complete antimicrobial effect on E. coli, P. aeruginosa and S. aureus in all catheters. CONCLUSIONS: It should be recommended to patients on CIC to use a sterile packed and not previously used catheter. In this study we have shown that immersing the catheters in a 70% alcohol solution during 5 minutes can effectively disinfect the catheter without jeopardising the physical qualities. Thereafter, the catheters could be placed in a resealable (e.g. Ziploc bag without being rinsed under water, in order that the few drops of alcohol cause alcohol vapours within the closed plastic bag and maintain the antimicrobial effect.

Equipment Contamination↗

Microwave-assisted enzyme-catalyzed reactions in various solvent systems.

The work describes the accelerated enzymatic digestion of several proteins in various solvent systems under microwave irradiation. The tryptic fragments of the proteins were analyzed by matrix-assisted laser desorption/ionization mass spectrometry. Under the influence of rapid microwave heating, these enzymatic reactions can proceed in a solvent such as chloroform, which, under traditional digestion conditions, renders the enzyme inactive. The digestion efficiencies and sequence coverages were increased when the trypsin digestions occurred in acetonitrile-, methanol- and chloroform-containing solutions that were heated under microwave irradiation for 10 min using a commercial microwave applicator. The percentage of the protein digested under microwave irradiation increased with the relative acetonitrile content, but decreased as the methanol content was increased. These observations suggest that acetonitrile does not deactivate the enzyme during the irradiation period; in contrast, methanol does deactivate it. In all cases, the digestion efficiencies under microwave irradiation exceed those under conventional conditions.

Animals↗

Microwave-treated gelatin microspheres as drug delivery system.

The crosslinking process of natural macromolecules with microwave energy should have the potentiality to overcome the problems due to the toxicity of the residuals of chemical crosslinking agents and moreover of the "in vivo" biodegradation products of the chemical crosslinked macromolecule. To evaluate the effective crosslinking of the gelatin forming the microspheres, the water-soluble fraction at 37 degrees C, the water absorption capability, the free amino and free carboxylic acid groups of the gelatin were determined. The structural change in the gelatin microspheres has been detected by the porosity studies. Moreover, both the "in vitro" biodegradability and the biocompatibility of the gelatin microspheres microwave-treated after a subcutaneous injection into female albino guinea pigs were tested. As the results suggest only the gelatin microspheres microwave-treated for 10 min at an inlet temperature of 250 degrees C could have been modified by the crosslink formation among the macromolecular chains. The gelatin microspheres treated with the microwave energy were very well biodegraded as indicated both by the "in vitro" enzymatic degradation studies and mainly by the histopathological examination. This latter study has also demonstrated the biocompatibility of the gelatin microspheres crosslinked with the microwave energy. In order to evaluate the feasibility of the microwave crosslinking process for pharmaceutical applications, both the drug loading and the drug release processes were evaluated using diclofenac as drug model, either as acidic form or as sodium salt. The microspheres were swollen in aqueous solution of diclofenac sodium salt, followed by a washing procedure with cool water to maintain the sodium salt into the microspheres or with pH 1.5 HCl to induce the diclofenac precipitation. To increase the amount of diclofenac acid form in the microspheres, the procedure was repeated three times washing with pH 1.5 HCl after each swelling process. Both the X-ray diffractometry and thermal analysis investigations showed a different physical state of the two drug forms in the microspheres, i.e. the amorphous state of the sodium salt and the crystalline state of the acidic form. According to the experimental results, the drug is released from gelatin microspheres according to the drug loading and the drug solubility.

Animals↗

Effect of microwave sterilization and water storage on the Vickers hardness of acrylic resin denture teeth.

STATEMENT OF PROBLEM: Acrylic resin denture teeth soften upon immersion in water, and the heating generated during microwave sterilization may enhance this process. PURPOSE: Six brands of acrylic resin denture teeth were investigated with respect to the effect of microwave sterilization and water immersion on Vickers hardness (VHN). MATERIAL AND METHODS: The acrylic resin denture teeth (Dentron [D], Vipi Dent Plus [V], Postaris [P], Biolux [B], Trilux [T], and Artiplus [A]) were embedded in heat-polymerized acrylic resin within polyvinylchloride tubes. For each brand, the occlusal surfaces of 32 identical acrylic resin denture posterior teeth were ground flat with 1500-grit silicon carbide paper and polished on a wet polishing wheel with a slurry of tin oxide. Hardness tests were performed after polishing (control group, C), after polishing followed by 2 cycles of microwave sterilization at 650 W for 6 minutes (MwS group), after polishing followed by 90-day immersion in water (90-day Wim group), and after polishing followed by 90-day storage in water and 2 cycles of microwave sterilization (90-day Wim + MwS group). For each specimen, 8 hardness measurements were made and the mean was calculated. Data were analyzed with a 2-way analysis of variance followed by the Bonferroni procedure to determine any significance between pairs of mean values (alpha=.01). RESULTS: Microwave sterilization of specimens significantly decreased (P <.001) the hardness of the acrylic resin denture tooth specimens P (17.8 to 16.6 VHN), V (18.3 to 15.8 VHN), T (17.4 to 15.3 VHN), B (16.8 to 15.7 VHN), and A (17.3 to 15.7 VHN). For all acrylic resin denture teeth, no significant differences in hardness were found between the groups MwS, 90-day Wim, and 90-day Wim + MwS, with the exception of the 90-day Wim + MwS tooth A specimens (14.4 VHN), which demonstrated significant lower mean values (P <.001) than the 90-day Wim (15.8 VHN) and MwS (15.7 VHN) specimens. CONCLUSIONS: For specimens immersed in water for 90 days, 2 cycles of microwave sterilization had no effect on the hardness of most of the acrylic resin denture teeth.

Acrylic Resins↗

Effect of whole-body 1800MHz GSM-like microwave exposure on testicular steroidogenesis and histology in mice.

The aim of our study was to evaluate the possible effects of whole-body 1800 MHz GSM-like microwave exposure on male reproduction. After repeated exposure of mice to microwaves at 0.018-0.023 W/kg whole-body specific energy absorption rate (SAR) an elevated serum testosterone level was measured, but no microwave exposure related histopathological alteration could be detected in the reproductive organs. The in vitro steroidogenic response of 48 h Leydig cell cultures obtained from exposed animals did not differ from the controls, suggesting that Leydig cells were not the primary targets of the applied microwave exposure or direct action of microwaves on Leydig cells was temporary only. In exposed animals the red blood cell count and volume of packed red cells were also increased. Further investigations are required to clarify the mechanism of action of the applied microwave exposure on male mice, as well as to establish the biological significance of the observed phenomena.

Alanine Transaminase↗

Improvement of oxidative decomposition of aqueous phenol by microwave irradiation in UV/H2O2 process and kinetic study.

2.5GHz of microwave irradiation can cause a considerable improvement of oxidative decomposition of aqueous phenol in a UV/H2O2 system. The experimental results showed that the microwave irradiation can raise both the phenol conversion and the TOC removal efficiency up to or above 50%. Also, the microwave irradiation could considerably enhance the oxidative degradation of phenol in the UV/H2O2 system even under a suppression of thermal effect. Addition of hydrogen peroxide by more than a stoichiometric amount was critical to mineralize aqueous phenol to create a short reaction time. Also, microwave irradiation can accelerate the degradation rate of intermediates, hydroquinone and catechol, produced in the course of phenol oxidative decomposition. From the kinetic study, the disappearance rate of phenol can be expressed as dX/dt = kPH[M]0(alpha - X)(1 - X), where alpha equivalent [H2O2]0/[M]0 + kOH[OH*]/kPH[M]0, shows a good correlation with the experimental data. The kinetic analysis showed that an indirect reaction of phenol with OH radical might be dominant in the absence of microwave irradiation, meanwhile a direct reaction of phenol with hydrogen peroxide might be dominant in the presence of microwave irradiation except for low concentrations of hydrogen peroxide.

Disinfectants↗