Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Humeral Fractures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Periprosthetic humeral fractures after total elbow arthroplasty: treatment with implant revision and strut allograft augmentation.

BACKGROUND: Periprosthetic fractures are among the most challenging complications of elbow arthroplasty, and published information about the outcome of treatment is limited. The purpose of the present study was to determine the results of implant revision and strut allograft augmentation for the treatment of humeral periprosthetic fractures that occur around a loose humeral component. METHODS: Between 1991 and 1999, eleven periprosthetic fractures that occurred around a loose humeral component were treated with cortical strut allograft augmentation and revision arthroplasty with use of a Coonrad-Morrey semiconstrained implant. Six fractures occurred after a primary arthroplasty, and five occurred after a revision arthroplasty. Two parallel strut grafts were used for fracture fixation in most cases. Patients were followed for an average of three years (range, nine months to 7.8 years) and were evaluated clinically and radiographically. RESULTS: Clinical and radiographic fracture union was obtained in ten of the eleven patients. One patient required revision surgery because of aseptic loosening of the humeral component seven years and nine months after fracture union; there were no other implant failures. Complications included one additional nondisplaced humeral periprosthetic fracture after surgery that failed to heal with closed treatment, one olecranon fracture, one permanent ulnar nerve injury, and one case of triceps insufficiency. At the time of the most recent follow-up, seven of the eight patients with an intact reconstruction had a functional arc of motion and no or slight pain and one had limited motion and moderate pain. CONCLUSIONS: Periprosthetic humeral fractures that are associated with a loose humeral component can be effectively treated with revision elbow arthroplasty and strut allograft augmentation. The technique is associated with a high rate of fracture union, implant survival, and satisfactory clinical results. However, the complication rate is substantial.

Adult↗

Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws.

The purpose of this study was to investigate the 3-dimensional trabecular bone mineral density (BMD) in the humeral head and determine the effects of trabecular BMD on the pullout strength of cancellous screws. Five regions of interest (ROIs) were defined in the humeral head (superior- anterior, superior-posterior, central, inferior-anterior, and inferior-posterior). The trabecular BMD of each ROI was determined by use of peripheral quantitative computed tomography. Cancellous screws were inserted in each ROI and cyclically loaded. The superior-anterior ROI had a lower trabecular BMD than all other ROIs (P < .001). The central ROI had a higher trabecular BMD than the inferior-anterior ROI (P < .01), whereas no differences were found between the inferior-posterior, superior-posterior, and central ROIs. Pullout strength was lower in the superior-anterior ROI compared with all other ROIs (P < .01). The trabecular BMD and pullout strength were significantly correlated (P < .01). Placement of screws in regions with a higher trabecular BMD may help to prevent implant loosening and may improve patient outcome.

Aged↗

A biomechanical comparison of Schuhli nuts or cement augmented screws for plating of humeral fractures.

Schuhli locking nuts can be used in poor quality cortical bone to enhance fixation stability as an alternative to cement augmented screws. This study compared the fixation strength and stability of plate constructs using Schuhli locking nuts with standard screws and cement augmented screws for fixation of simulated humeral shaft fractures in a test model with osteoporosis. The constructs were tested in axial compression, 4-point bending, and torsion to determine fixation stability. The humeri were cycled in torsion (4.5 Nm) for 1000 cycles to simulate upper extremity use during the early postoperative period and retested for stability. The Schuhli locking nuts and cement augmented screws had significantly greater fixation stability than the standard screws before (range, 6-14 times greater) and after cycling in torsional loading (range, 3-3.6 times greater). Although cement augmented screws and Schuhli augmentation showed increased fixation stability compared with the standard screws in axial and 4-point bending before cycling (range, 1.3-1.4 times greater), this was not significant. Compared with Schuhli fixation, cement augmented screws showed no significant difference in fixation stability in all loading modes before and after cycling. Schuhli locking nuts offer the stability of cement augmentation while avoiding its potential adverse effects on fracture healing with extravasation and thermal necrosis.

Biomechanical Phenomena↗

Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture.

The management of fractures of the proximal shaft of the humerus has been evolving since the development of new techniques and new implants in recent years. It seems that this kind of fracture has an increasing incidence in the older, osteoporotic population. In the last 2 years, we have operated on 17 patients, with an average age of 65, who had proximal humeral shaft fractures treated by minimally invasive percutaneous osteosynthesis (MIPO) technique using the metaphyseal locking compression plate. Our study evaluated the surgical technique used and the outcome for these patients with regards to their range of movement and shoulder function. Our results showed that all the patients could achieve at least 140 masculine of shoulder abduction in the first 6 months after the operation, except for three patients who had shoulder impingement. These patients had an average Constant score of 76.8. All fractures had bony union at 6 months, except one, which was probably due to poor reduction in the initial operation. Another complication that we encountered was radial nerve neuropraxia. The ways to prevent these complications are discussed. In conclusion, MIPO fixation using the metaphyseal locking compression plate is a good option for the management of proximal humeral shaft fractures. It provides early functional recovery, but we had to pay special attention to some of the surgical details in order to minimise complications.

Adult↗

Treatment of humeral shaft fractures with humeral locked nail and comparison with plate fixation.

OBJECTIVE: To report the experience of a newly devised humeral locked nail in treating acute humeral shaft fractures and to compare its effectiveness with that of plate fixation. DESIGN AND METHODS: Data were collected on 48 acute humeral shaft fractures in 48 consecutive patients treated with humeral locked nails and compared with retrospective data on 25 fractures in 25 other patients treated with dynamic compression plates. The operation time, amount of blood transfusion, time to union, complications, and functional recovery were recorded and compared. The average follow-up time was 20.5 months for the nail group and 33.3 months for the plate group. Student's t test and Fisher's Exact Test were used for statistical analyses. RESULTS: Locked nailing had significantly shorter operation time and less blood transfusion than did plate fixation, 68 versus 93 minutes and 0 versus 102 mL, respectively. Eventual union was achieved among all in the nail group and among all but one in the plate group. Union rate and time to union were not significantly different. In the plate group, three fractures had complications: one with implant loosening and nonunion, one with deep infection, and one with postoperative radial nerve palsy; the nail group had no complications. The difference in complication rates was statistically significant. In the nail group, one varus malunion and one intraoperative comminution occurred, without adverse consequences. Functional recovery was essentially the same in both groups for uncomplicated fractures. CONCLUSIONS: Humeral locked nailing offered a less invasive surgical technique and more favorable treatment results than did plate fixation. Correct nailing direction, precise surgical techniques, less bulky hardware, and stable transfixing screws are the keys to a successful treatment. Further prospective, randomized comparative study is warranted.

Adult↗

Semitubular blade plate fixation in proximal humeral fractures: a biomechanical study in a cadaveric model.

This study was undertaken to compare the fixation of the semitubular blade plate with that of the AO T plate. Cadaveric humeri (n=12 pairs) from an elderly population (41 to 89 years) had either a blade plate (n=12) or a T plate (n=12) fixed to them, subsequent to which a transverse osteotomy was performed. Mechanical testing in tension was performed in 1 series (n=5, blade plate; n=5, T plate) by applying a single maximal load to failure and in a second series (n=7, blade plate; n=7, T plate) by applying submaximal cyclic loading before failure was induced. Results showed that the fixation provided by the semitubular blade plate was significantly better (P < .05) than that of the T plate in those specimens subjected to submaximal cyclic loading before failure (series 2). This latter testing method contains some component of the clinical situation compared with monotonic distraction to failure. Based on these results plus favorable clinical results reported in the literature, the semitubular blade plate is possibly a better alternative to the T plate in the management of proximal humeral fractures that require open reduction and internal fixation.

Adult↗

Complex proximal humeral fractures in adults--a systematic review of management.

We performed a systematic review of the literature to compare the clinical outcomes of the management of three and four part fractures of the proximal humerus by conservative regimes, internal and external fixations and arthroplasty. We identified 147 reports of comparative trials and case series between 1969 and 1999. We selected only studies dealing exclusively with three and four part fractures of the proximal humerus, with at least 15 patients, treated within 48 h of injury by one of the three modalities studied, in which at least one of the outcomes of interest (pain, range of motion, infection and restoration of anatomy) was described. Also, to be included, studies had to have a follow-up period of at least 6 months, in which a minimum of 85% of patients were followed-up. Twenty four reports met our eligibility criteria. Conservatively managed patients had more pain and a poorer range of motion than those managed by either fixation or arthroplasty. Better restoration of anatomy was delivered in the fixation group. There was no significant difference in the functional range of motion between the arthroplasty and fixation groups, but there were very few studies available to compare infection rates in these two management modalities. The results from the present systematic review suggest that the data from the published literature are inadequate for evidence-based decision making with regards to the treatment of complex proximal humeral fractures.

Arthroplasty↗

Vascularity of the humeral head after proximal humeral fractures. An anatomical cadaver study.

We studied the arterial anatomy and the effect of four-part fractures on the vascularity of the humeral head, using barium sulphate perfusion of 16 cadaver shoulders. The main arterial supply to the humeral head was via the ascending branch of the anterior humeral circumflex artery and its intraosseous continuation, the arcuate artery. There were significant intraosseous anastomoses between the arcuate artery and: 1) the posterior humeral circumflex artery through vessels entering the posteromedial aspect of the proximal humerus; 2) metaphyseal vessels; and 3) the vessels of the greater and lesser tuberosities. Simulated four-part fractures prevented the perfusion of the humeral head in most cases. If, however, the head fragment extends distally below the articular surface medially, some perfusion of the head persists by the posteromedial vessels. These vessels are important in the management of comminuted fractures of the proximal humerus.

Aged↗

[Indications for the surgical and conservative treatment of juvenile supracondylar humeral fractures and their results].

In the period from 1977 to 1982 78 children were treated for supracondylar fractures of the humerus at the Berufsgenossenschaftliche Unfallklinik Frankfurt/Main. Indications and methods for operative and conservative treatment are described. The results of therapy were reviewed by means of a questionnaire or reexamination in 68 patients with regard to function, elbow deformity and nerve lesions. Fractures of a grade I severity are to be treated conservatively by immobilisation in a POP-cast. Only in exceptional cases of grade II severity can a closed reduction be recommended. All remaining types of fractures of grade II and III severity should primarily be treated by open operations within 8 hours of the accident. Under these conditions the risk of infection is no higher than with percutaneous Kirschner-wire-osteosynthesis. Complications such as appreciable varus deformity, poor function and nerve lesions can largely be avoided in this way. The so-called extension-treatment offers no advantages in comparison with operative treatment.

Adolescent↗

[Surgical treatment of type I capitellar-humeral fractures using the Henry ventral approach approach. Short- and medium-term results].

Capitellar fractures are rare. Despite adequate surgical treatment, patients suffer frequently from limited range of motion, osteonecrosis, and neurological deficits. The purpose of this retrospective study was to evaluate short- and medium-term surgical results in seven patients who had type I capitellar fractures according to Bryan and Morrey. All patients were treated via an anterior approach, according to Henry, and open reduction and internal fixation with two screws. Seven patients were examined clinically, neurologically, and radiologically after 10-65 months. The fracture healed in all patients. None of the patients had a neurological deficit. According to the Morrey Score, five of seven patients had an excellent or good functional result. Open reduction and internal fixation with two screws via the Henry approach is a suitable option for surgical treatment for type I capitellar fractures.

Adult↗

The results of internal fixation of three- and four-part proximal humeral fractures with the Polarus nail.

Twenty-three patients with acute displaced three- and four-part fractures of the proximal humerus, including seven patients with associated shaft involvement, were treated with the Polarus intramedullary interlocking nail using a closed technique. At the 1-year follow up, the median Neer scores were 89 and 60 for the three- and four-part fractures, respectively. Three patients (13%), all of whom were in the four-part group, continued to have significant pain at final review. We found the implant to be extremely satisfactory and particularly useful in the treatment of combined neck and shaft fractures of the humerus.

Adult↗

[Indications and results of the surgical treatment of distal intra-articular humeral fractures in the elderly].

In this paper we review 16 patients with closed intercondylar fractures of the distal end of the humerus that had open reduction and internal fixation. All patients were older than 60 years of age. Using the classification system of Müller et al. 6 fractures were classified as type C2 and 10 fractures as type C3. The surgical procedures and the types of internal fixation of the fractures allowed early postoperative mobilisation (3rd postoperative day). A rating scale modified according to Cassebaum was used for the results. At a mean follow-up of 4.2 years 3 patients were rated as excellent 9 as good and 2 as fair. No severe complications were registered.

Aged↗