Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Electroplating”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Miniaturized lead sensor based on lead-specific DNAzyme in a nanocapillary interconnected microfluidic device.

A miniaturized lead sensor has been developed by combining a lead-specific DNAzyme with a microfabricated device containing a network of microfluidic channels that are fluidically coupled via a nanocapillary array interconnect. A DNAzyme construct, selective for cleavage in the presence of Pb2+ and derivatized with fluorophore (quencher) at the 5' (3') end of the substrate and enzyme strands, respectively, forms a molecular beacon that is used as the recognition element. The nanocapillary array membrane interconnect is used to manipulate fluid flows and deliver the small-volume sample to the beacon in a spatially confined detection window where the DNAzyme is interrogated using laser-induced fluorescence detection. A transformed log plot of the fluorescent signal exhibits a linear response (r2 = 0.982) over a Pb2+ concentration range of 0.1 - 100 microM, and a detection limit of 11 nM. The sensor has been applied to the determination of Pb2+ in an electroplating sludge reference material, the result agreeing with the certified value within 4.9%. Quantitative measurement of Pb2+ in this complex sample demonstrates the selectivity of this sensor scheme and points favorably to the application of such technologies to analysis of environmental samples. The unique combination of a DNAzyme with a microfluidic-nanofluidic hybrid device makes it possible to change the DNAzyme to select for other compounds of interest, and to incorporate multiple sensing systems within a single device for greater flexibility. This work represents the initial steps toward creation of a robust field sensor for lead in groundwater or drinking water.

Biosensing Techniques↗

Synergistic effects in multicomponent electrocatalysts: the Pb-Ir-O system.

The ionic interactions were studied in aqueous solutions of Na(3)IrCl(6) + Pb(NO(3))(2) in order to develop a facilitated electrosynthesis of iridium-based catalytic surfaces. Spectroscopic studies indicated that ion pair charge-transfer complexes [IrCl(6)(3-)]-Pb(II) (K = 6 x 10(3)) and [Ir(H(2)O)Cl(5)(2-)]-Pb(II) (K = 2 x 10(3)) were formed in fresh and aged solutions, respectively. Electrochemical studies showed that interactions between the Ir(H(2)O)Cl(5)(2-) and Pb(II) species lead to synergistic lowering of the overpotential that was necessary for nucleation and growth of mixed metal oxide PbIrOx on the surface of glassy carbon electrodes. The Ir:Pb stoichiometry of the PbIrOx surface films was the same (1:1) as that of the high-temperature phase of Pb-Ir-O pyrochlore. Compared to IrOx, the PbIrOx films displayed enhanced catalytic activity toward the electrooxidation of carbohydrates. This was ascribed to synergism that involved retention of carbohydrate molecules at the Pb(II) sites of a PbIrOx film and oxidation at the adjacent Ir(IV) sites. The synergistic electroplating utilizing interactions between the partially aquated transition metal complex and posttransition metal ion represents a new synthetic route to highly homogeneous and reactive films of mixed metal oxides.

Journal Article↗

Gas sensor array based on metal-decorated carbon nanotubes.

Here we demonstrate design, fabrication, and testing of electronic sensor array based on single-walled carbon nanotubes (SWNTs). Multiple sensor elements consisting of isolated networks of SWNTs were integrated into Si chips by chemical vapor deposition (CVD) and photolithography processes. For chemical selectivity, SWNTs were decorated with metal nanoparticles. The differences in catalytic activity of 18 catalytic metals for detection of H(2), CH(4), CO, and H(2)S gases were observed. Furthermore, a sensor array was fabricated by site-selective electroplating of Pd, Pt, Rh, and Au metals on isolated SWNT networks located on a single chip. The resulting electronic sensor array, which was comprised of several functional SWNT network sensors, was exposed to a randomized series of toxic/combustible gases. Electronic responses of all sensor elements were recorded and the sensor array data was analyzed using pattern-recognition analysis tools. Applications of these small-size, low-power, electronic sensor arrays are in the detection and identification of toxic/combustible gases for personal safety and air pollution monitoring.

Journal Article↗

Conical tungsten tips as substrates for the preparation of ultramicroelectrodes.

Here we describe a simple method to prepare voltammetric microelectrodes using tungsten wires as a substrate. Tungsten wires have a high tensile modulus and enable the fabrication of electrodes that have small dimensions overall while retaining rigidity. In this work, 125 microm tungsten wires with a conical tip were employed. For the preparation of gold or platinum ultramicroelectrodes, commercial tungsten microelectrodes, completely insulated except at the tip, were used as substrates. Following removal of oxides from the exposed tungsten, platinum or gold was electroplated, yielding surfaces with an electroactive area of between 1 x 10-6 and 2 x 10-6 cm2. Carbon surfaces on the etched tip of tungsten microwires were prepared by coating with photoresist followed by pyrolysis. The entire electrode was then insulated with Epoxylite except the tip, yielding an exposed carbon surface with an area of around 4 x 10-6 to 6 x 10-6 cm2. All three types of ultramicroelectrodes fabricated on the tungsten wire had similar electrochemical behavior to electrodes fabricated from wires or fibers insulated with glass tubes.

Carbon↗

Attenuation of protein adsorption on static and oscillating magnetostrictive nanowires.

The research described here investigates the hypothesis that nanoarchitecture contained in a nanowire array is capable of attenuating the adverse host response generated when medical devices are implanted in the body. This adverse host response, or biofouling, generates an avascular fibrous mass transfer barrier between the device and the analyte of interest, disabling the implant if it is a sensor. Numerous studies have indicated that surface chemistry and architecture modulate the host response. These findings led us to hypothesize that nanostructured surfaces will inhibit the formation of an avascular fibrous capsule significantly. We are investigating whether arrays of oscillating magnetostrictive nanowires can prevent protein adsorption. Magnetostrictive nanowires were fabricated by electroplating a ferromagnetic metal alloy into the pores of a nanoporous alumina template. The ferromagnetic nanowires are made to oscillate by oscillating the magnetic field surrounding the wires. Radiolabeled bovine serum albumin, enzyme-linked immunosorbent assay (ELISA), and other protein assays were used to study protein adhesion on the nanowire arrays. These results display a reduced protein adsorption per surface area of static nanowires. Comparing the surfaces, 14-30% of the protein that absorbed on the flat surface adsorbed on the nanowires. Our contact angle measurements indicate that the attenuation of protein on the nanowire surface might be due to the increased hydrophilicity of the nanostructured surface compared to a flat surface of the same material. We oscillated the magnetostrictive wires by placing them in a 38 G 10 Hz oscillating magnetic field. The oscillating nanowires show a further reduction in protein adhesion where only 7-67% of the protein on the static wires was measured on the oscillating nanowires. By varying the viscosity of the fluid the nanowires are oscillated in, we determined that protein detachment is shear-stress modulated. We created a high shearing fluid with dextran, which reduced protein adsorption on the oscillating nanowires by 70% over nanowires oscillating in baseline viscosity fluid. Our preliminary studies strongly suggest that the architecture in the static nanowire arrays and the shear created by oscillating the nanowire arrays would attenuate the biofouling response in vivo.

Adsorption↗

Occupational asthma caused by palladium.

Occupational exposure to complex platinum salts is a well-known cause of occupational asthma. Although there is evidence that platinum refinery workers may also be sensitized to other precious metals, such as palladium or rhodium, no instances of occupational asthma due to an isolated sensitization to palladium have been reported. A case is reported of occupational rhinoconjunctivitis and asthma in a previously healthy worker exposed to the fumes of an electroplating bath containing palladium. There was no exposure to platinum. Sensitization to palladium was documented by skin-prick tests. The skin-prick test was positive with Pd(NH3)4Cl2, but not with (NH4)2PdCl4. Corresponding salts of platinum were all negative. A bronchial provocation test with Pd(NH3)4Cl2 (0.0001% for a total of 315 s, followed by 0.001% for a total of 210 s) led to an early decrease in forced expiratory volume in one second (-35%). A similar exposure (0.001% for a total of 16 min) in an unrelated asthmatic gave no reaction. This case shows that an isolated sensitization to palladium can occur and that respiratory exposure to palladium is a novel cause of metal-induced occupational asthma.

Adult↗

Bismetalloporphyrin-based ISE sensitive to fluoroborate.

Several mu-oxo-bismetalloporphyrin complexes were synthesized for preparing fluoroborate sensors. The electrode based on mu-oxo-bis[tetra(p-chlorophenyl)porphinatomanganese(III)] with an optimized membrane composition shows a potentiometric response towards fluoroborate ion over the concentration range from 4.3 x 10(-7) to 1.0 x 10(-1) mol l-1 with a Nernstian slope, a wide working pH range from 5.5 to 12.0 and a fast response time of 30 s. The electrode shows anti-Hofmeister selectivity towards BF4- with respect to common co-existing ions, which is an improvement over methods reported so far. As electroactive materials, several mu-oxo-bismetalloporphyrins with different substituents on the benzene rings were compared for potentiometric response characteristics. The interaction between BF4- and bismetalloporphyrin was investigated using UV/VIS spectrophotometry. The electrode was applied to the determination of fluoroborate in electroplating solutions.

Borates↗

A mediator-type biosensor as a new approach to biochemical oxygen demand estimation.

A novel biosensor for the determination of biochemical oxygen demand (BOD) was developed using potassium hexacyanoferrate(III) [HCF(III)] as a mediator. The sensor element consists of a three-electrode system, with both working and counter electrodes compactly integrated as a disposable using etching and electroplating processes. Pseudomonas fluorescens biovar V (isolated from a wastewater treatment plant) was immobilized on the surface of the working electrode using poly(vinyl alcohol)-quaternized stilbazol (PVA-SbQ) photopolymer gel. Synthetic wastewater described by the Organization for Economic Cooperation and Development (OECD) was used as a standard solution instead of glucose-glutamic acid synthetic wastewater. The conditions of amperometric measurement were optimized at +600 mV (vs. Ag/AgCl) operating potential, namely 40 mM HCF(III) in a 0.1 M phosphate buffer (pH 7.0) at 20 degrees C. The sensor response was linear from 15 up to 200 mg O l-1 BOD. The response time was 15 min at 200 mg O l-1 BOD. To demonstrate the wide metabolic range of activity of the sensor, the sensor response to 14 substances in four categories of organic compounds was investigated. Further, it was shown that the response of this BOD sensor was not influenced in samples with low concentrations of dissolved oxygen under the measuring conditions used. For real wastewaters, the BOD values were determined using the sensor and compared favorably with those determined by the conventional BOD5 method.

Journal Article↗

Plasma etched polymer microelectrochemical systems.

This paper presents a novel technique based on plasma etching for the mass production of polymer microchip devices. The method consists of the patterning of a photo-resist by a high resolution printer on a foil composed of three layers (5 microm copper/50 microm polyimide/5 microm copper). After this step, both copper layers are chemically etched in order to serve as a contact mask on the polyimide surface so as to produce the desired microstructure pattern. The foil is placed into a reactive plasma chamber in order to etch the exposed polyimide by means of an oxidizing plasma. The method enables holes, lines or larger areas to be etched, thereby generating either microholes, microchannels or electrodes in the plastic material. The copper can then be chemically removed or further patterned to produce conductive pads which are further electroplated with gold. The microchannel is then covered with a polyethylene terephthalate/polyethylene (PET/PE) lamination. The strength of this technology is that access holes for the fluid inlet and outlet, as well as gold coated electrodes can be fabricated without post-processing in a batch process. Demonstration of the application of such microelectrochemical systems is shown here by voltammetric detection inside a 60 nL microchannel, which presents the special feature of linear depletion of the analytes in the direction parallel to the microchannel.

Journal Article↗

A microfluidic electroporation device for cell lysis.

We demonstrate a micro-electroporation device for cell lysis prior to subcellular analysis. Simple circuit models show that electrical lysis method is advantageous because it is selective towards plasma membrane while leaving organelle membrane undamaged. In addition, miniaturization of this concept leads to negligible heat generation and bubble formation. The designed microdevices were fabricated using a combination of photolithography, metal-film deposition, and electroplating. We demonstrate the electro-lysis of human carcinoma cells in these devices to release the subcellular materials.

Cell Fractionation↗

Acoustic micromachining of three-dimensional surfaces for biological applications.

We present the use of an accessible micromachining technique (acoustic micromachining) for manufacturing micron-feature surfaces with non-discretely varying depth. Acoustic micromachining allows for non-photolithographic production of metal templates with programmable spatial patterns and involves the use of standard acoustic, cutting and electroplating equipment for mass production of vinyl records. Simple 3D patterns were transferred from an acoustic signal into working nickel templates, from which elastic polymer molds were obtained, featuring deep surface grooves and non-discrete (smooth) variations in the z-dimension. Versatility and applicability of the method is demonstrated in obtaining microfluidics structures, manufacturing high-surface area wavy polymer fibers, assembly of cell networks on scaffolds with 3D topography, and microcontact printing of proteins and cells.

Acoustics↗

A serpentine laminating micromixer combining splitting/recombination and advection.

Mixing enhancement has drawn great attention from designers of micromixers, since the flow in a microchannel is usually characterized by a low Reynolds number (Re) which makes the mixing quite a difficult task to accomplish. In this paper, a novel integrated efficient micromixer named serpentine laminating micromixer (SLM) has been designed, simulated, fabricated and fully characterized. In the SLM, a high level of efficient mixing can be achieved by combining two general chaotic mixing mechanisms: splitting/recombination and chaotic advection. The splitting and recombination (in other terms, lamination) mechanism is obtained by the successive arrangement of "F"-shape mixing units in two layers. The advection is induced by the overall three-dimensional serpentine path of the microchannel. The SLM was realized by SU-8 photolithography, nickel electroplating, injection molding and thermal bonding. Mixing performance of the SLM was fully characterized numerically and experimentally. The numerical mixing simulations show that the advection acts favorably to realize the ideal vertical lamination of fluid flow. The mixing experiments based on an average mixing color intensity change of phenolphthalein show a high level of mixing performance was obtained with the SLM. Numerical and experimental results confirm that efficient mixing is successfully achieved from the SLM over the wide range of Re. Due to the simple and mass producible geometry of the efficient micromixer, SLM proposed in this study, the SLM can be easily applied to integrated microfluidic systems, such as micro-total-analysis-systems or lab-on-a-chip systems.

Journal Article↗

Photoelectrochemical measurements of a heterosupramolecular system under visible light irradiation.

A photochemical system utilising a modular approach characterised through interpretation of photoelectrochemical measurements is discussed. A photoanode was prepared by the chemisorption of a photosensitiser, cis-bis-(2,2'-bipyridine)-(4,4'-bis-(methyl)phosphonato-2,2'-bipyridine)ruthenium(II) dichloride (RuL2L'2+), to a mixed nanoporous nanocrystalline RuO2:TiO2 thin film, calcined on a fluorine doped SnO2 conducting glass substrate. Similarly, an electron relay molecule, 1-ethyl-1'-(2-phosphonoethyl)-4,4'-bipyridinium dichloride (EVP), was covalently bound to a platinum electroplated nanoporous nanocrystalline TiO2 thin film, and the electrodes connected in a photoelectrocatalytic cell (PCC). Irradiation with lamda > 420 nm gave a measurable photocurrent. Interpretation of the photocurrents obtained from this assembly provides a means for understanding photochemical reactions under low light intensities. Optimised conditions of the electrolyte solution were determined to be pH = 5 and illumination yielded eta = 0.0036% with an apparent quantum yield (AQY)= 1.6%.

Journal Article↗

Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding.

Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 microl of the whole sample bloods, by means of the fabricated biochip within 3 min.

Blood Grouping and Crossmatching↗

Injection molded microfluidic chips featuring integrated interconnects.

An injection molding process for the fabrication of disposable plastic microfluidic chips with a cycle time of 2 min has been designed, developed, and implemented. Of the sixteen commercially available grades of cyclo-olefin copolymer (COC) that were screened for autofluorescence and transparency to ultraviolet (UV) light, Topas 8007 x 10 was identified as the most suitable for production. A robust solid metal mold insert defining the microfluidic channels was rapidly microfabricated using a process that significantly reduces the time required for electroplating. No wear of the insert was observed even after over 1000 cycles. The chips were bonded by thermal fusion using different bonding conditions. Each condition was tested and its suitability evaluated by burst pressure measurements. The COC microfluidic chips feature novel, integrated, reversible, standardized, ready-to-use interconnects that enable operation at pressures up to 15.6 MPa, the highest value reported to date. The suitability of these UV transparent, high pressure-resistant, disposable devices was demonstrated by in situ preparation of a high surface area porous polymer monolith within the channels.

Microfluidic Analytical Techniques↗

Application of ionic liquids to the electrodeposition of metals.

The electrodeposition of most of technologically important metals has been shown to be possible from a wide range of room temperature molten salts, more commonly known today as 'ionic liquids'. These liquids are currently under intense scrutiny for a wide variety of applications some of which have already been commercialized. Despite the fact that electrodeposition was the first application studied in these liquids no metal deposition processes have as yet been developed to an industrial scale. This review addresses the practical and theoretical aspects that need to be considered when choosing ionic liquids for metal deposition. It details the current understanding of the physical and chemical properties of these interesting fluids and highlights the areas that need to be considered to develop practical electroplating systems. The effect of composition and temperature on viscosity and conductivity are discussed together with the fundamental approaches required to synthesise new liquids.

Journal Article↗

[Immediate type allergies due to metal - nickel].

Occupational allergies of the immediate type due to metals, which are predominantly caused by nickel, platinum, chromium and cobalt, are rather rare. The present paper reviews the results of the evaluation of literature data concerning the occupational airway sensitization due to nickel, which is used in many different industrial fields - especially in the electroplating industry. Cases of specific airway sensizitation caused by nickel are verified by a number of studies, predominantly case histories. In conclusion, there is sufficient evidence that nickel may cause IgE-mediated hypersensitivity with typical symptoms.

Adult↗

Alpha-particles induce preneoplastic transformation of rat tracheal epithelial cells in culture.

To characterize the potential role of high-l.e.t. radiation in respiratory carcinogenesis, the cytotoxic and transforming potency of 5.5 Me V alpha-particles from electroplated sources of 238Pu were determined using primary cultures of rat tracheal epithelial cells. The alpha-particle response was compared to the effects of 280 kVp X-rays and of the direct-acting carcinogen N-methyl-N'-nitro-N-nitrosoguanidine. Increasing the alpha-particle dose caused an exponential decrease in survival with a D37 of 1.6 Gy. X-rays also caused a dose-dependent decrease in survival (D37 = 3.6 Gy) but the survival curve had a significant shoulder. The RBE for cell killing by alpha-particles versus X-rays varied with dose, and ranged between 4 and 1.5 for alpha doses in the range 0.2-4 Gy. At equally toxic doses (relative survival 0.18-0.2), all three agents induced similar frequencies of preneoplastic transformation. For preneoplastic transformation induced by doses of alpha- and X-radiations giving 80 per cent toxicity, an alpha RBE of 2.4 was derived. The similar RBEs for cell killing and for preneoplastic transformation suggest an association between the type or degree of radiation-induced damage responsible for both cell killing and cell transformation.

Alpha Particles↗