Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ELISA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Adaptation of a commercial ELISA for the detection of antibodies against Neospora caninum in bovine milk.

The aim of the present study was to determine whether a commercially available ELISA could be used to examine bovine milk for antibodies against Neospora caninum. In an initial titration experiment, a milk dilution of 1:2 was found optimal to obtain milk results that were linearly correlated to those obtained with corresponding sera. This dilution was then used to examine 791 milk samples from N. caninum infected herds in the commercial ELISA. Milk results of individual animals were compared with those obtained by the same ELISA for the corresponding serum samples. The linear correlation between milk and serum antibody results of individual animals was characterized by R2 = 0.702. Multiple linear regression indicated that the later the stage of lactation at which an animal was sampled, the higher the milk ELISA result was as compared to the serum ELISA result. The examination of the two-graph receiver operating characteristics revealed an optimal cut-off of 0.261 to obtain similar results in the examination of milk and serum. With this cut-off, the test had a sensitivity and specificity relative to the serum results of 90%. The milk-based commercial ELISA classified more aborting dams as positive than the serum-based ELISA with this cut-off. The milk ELISA may be a valuable tool to assess the herd status with regard to abortion caused by N. caninum.

Abortion, Veterinary↗

The repetitive use of samples to measure multiple cytokines: the sequential ELISA.

The inexpensive and highly effective enzyme-linked immunosorbant assay (ELISA) is widely used for the quantification of biomarkers in a variety of biological samples. The applicability of the standard ELISA is difficult when experiments yield low volume samples. In such studies, the capacity of sample collection system does not meet the sample volume requirements to measure multiple different cytokines by the traditional ELISA protocol. In the modified methodology of the sequential ELISA, samples are re-used in multiple successive cycles, dramatically increasing the number of biomarkers which may be measured. Although the protocols presented to date were developed for quantification of cytokines in either blood plasma or cerebrospinal fluid, the sequential ELISA protocol has wide potential for further uses. When only limited quantities of samples are available for analysis, the sequential ELISA technique based on commercially available antibody pairs can be an attractive alternative to more advanced, costly multiplex methods. Additionally, any laboratory that currently runs traditional ELISAs has all the necessary equipment and reagents to perform the sequential ELISA.

Animals↗

Development of Em18-immunoblot and Em18-ELISA for specific diagnosis of alveolar echinococcosis.

Extensive experience has documented that Em2(plus)-ELISA, Em10-ELISA and Em18-immunoblot and Em18-ELISA are reliable serologic methods for detection of alveolar echinococcosis (AE) caused by the metacestodes of Echinococcus multilocularis. Among these, tests based on detection of antibodies to the specific Em18 antigen, either immunoblot or ELISA, appears to be the most specific for AE. Between 90 and 97% of AE cases with characteristic hepatic lesions detectable by image analysis have been positive in Em18-serology. In contrast Antigen B (8 kDa)-immunoblot is the most sensitive for all forms of echinococcosis, although it can not differentiate AE from cystic echinococcosis (CE). Primary serologic screening for echinococcosis, especially for CE using hydatid cyst fluid of Echinococcus granulosus appears to be highly sensitive in endemic areas. Glycoproteins (GPs) purified from cyst fluid of Taenia solium are highly specific for diagnosis of T. solium neuorcysticercosis (NCC). Using currently available antigens it is not difficult to differentiate these three larval cestodiases serologically. We recommend that (1) primary screening of CE in endemic areas should be carried out using hydatid cyst fluid of E. granulosus prepared from cysts in either sheep, human or mouse for immunoblot and from sheep or mouse for ELISA, (2) both primary screening and confirmation of AE in endemic areas should be carried out using Em18-ELISA, Em18-immunoblot or Em2(plus)-ELISA. Serodiagnosis in areas where both AE and CE are endemic, such as in China, should be carried out as a combination of (1) and (2), and (3) serology of NCC should be carried out using GP-ELISA or GP-immunoblot. All samples showing antibody to Em18 are exclusively from echinococcosis cases. There have been no false positive test reactions with sera from other diseases. Strongest Em18 responders are all from patients with AE but some weaker responses may be found in sera of persons with advanced complex lesions of CE. These highly reliable serodiagnostic methods using native, recombinant and synthetic antigens are briefly summarized and experiences with these methods in Japan is reviewed. We believe that use of these specific antigens in screening and confirmation programs for AE in Japan will improve specificity and reduce the confusion, anxiety and expense in persons whose sera give false positive reactions with crude echinococcal antigens.

Animals↗

PCR-ELISA for the detection of Brugia malayi infection using finger-prick blood.

A polymerase chain reaction assay based on the enzyme-linked immunosorbent assay (PCR-ELISA) has been developed to detect Brugia malayi infection in an area of low endemicity in Malaysia. Blood samples from 239 subjects were tested: 192 amicrofilaraemic individuals, 14 microfilaraemic persons and 3 chronic elephantiasis cases from endemic areas and 30 city-dwellers (non-endemic controls). PCR products were examined by ELISA and Southern hybridization. In the PCR-ELISA, digoxigenin-labelled PCR products were hybridized to a biotin-labelled probe. This was followed by incubation in streptavidin-coated microtitre wells and detection using anti-digoxigenin-peroxidase and ABTS [2,2'-azinobis(3-ethylbenzthiazoline-6-sulphonic acid)]. All microfilaraemic samples were positive by PCR-ELISA and Southern hybridization and all samples from non-endemic subjects and chronic elephantiasis patients were negative. The PCR-ELISA detected 12 times as many B. malayi infections as did thick blood film examination. Nineteen of the 194 samples from the endemic area gave positive results by both PCR-ELISA and Southern hybridization, and an additional 5 samples were positive by PCR-ELISA only. The PCR-ELISA was specific and sensitive, detected more infections, and was more reproducible than Southern hybridization.

Animals↗

ELISA for salivary and plasma estriol in pregnancy.

A competitive, sensitive, and rapid enzyme-linked immunoadsorbent assay (ELISA) was developed for the determination of estriol in saliva and in plasma. Horseradish peroxidase (HRP) was used as the label enzyme; separation between free and bound steroid was carried out by insolubilized antibody prepared by adsorbing purified IgG of rabbit anti-6-oxoestriol-6-(O-carboxymethyl)oxime-BSA on polystyrene balls. The enzyme activity was measured by a colorimetric reaction using o-phenylenediamine dihydrochloride and hydrogen peroxide as substrate. The sensitivity of the assay was 12 pg/tube. In order to compare ELISA to RIA estriol estimations in different biological fluids, we selected six women during normal pregnancy, from the 30th to the 40th week of gestation. Salivary estriol was assayed by direct and extraction methods, while the corresponding plasma samples of the same subjects were analyzed only for unconjugated estriol by an extraction method. A good agreement was found between the results obtained by RIA and ELISA: r = 0.897, p less than 0.001 between direct RIA and direct ELISA in saliva; r = 0.909, p less than 0.001 between extraction RIA and direct ELISA in saliva; and r = 0.916, p less than 0.001 between extraction RIA and extraction ELISA in plasma. A good correlation (r = 0.793, p less than 0.001) was present between plasma samples by RIA and saliva samples by ELISA (direct method). These results indicate that: ELISA is a reliable method for the determination of estriol in plasma and saliva. Saliva samples can be used for the assay of estriol and therefore for the assessment of fetal conditions during pregnancy.

Enzyme-Linked Immunosorbent Assay↗

A sensitive color ELISA for detecting polycyclic aromatic hydrocarbon-DNA adducts in human tissues.

Human exposure to polycyclic aromatic hydrocarbons (PAHs) has been determined by measurement of DNA adducts in human tissues. Competitive enzyme-linked immunosorbent assays (ELISAs) using antisera recognizing benzo[a]pyrenediol-epoxide-modified DNA (BPDE-I-DNA) and color of fluorescence endpoint detection have been used extensively for quantifying PAH-DNA adducts. The fluorescence ELISA (limit of detection 1 adduct/10(8) nucleotides) was previously reported to be more sensitive than the color ELISA (1/10(7)) for measuring PAH adducts (Santella et al. (1988) Carcinogenesis, 9, 1265-1269). However, the fluorescence assay has the disadvantages of greater variation among the replicates and higher background levels than the color assay. Using a newly developed antiserum against BPDE-I-DNA, we have modified the color of ELISA so that it has the same sensitivity as the fluorescence ELISA and requires only 33% of the sample quantity needed for the fluorescence ELISA. The modifications included preincubation of the antiserum with the samples, using microtiter plates with half-size, flat bottom wells, and optimizing the assay conditions. The improved color ELISA was used to analyze DNA samples from human autopsy tissues, including heart, lung, liver, kidney, spleen, pancreas and stomach from smokers and nonsmokers. With the exception of spleen and stomach, all tissues from smokers showed higher PAH-DNA adducts (ranging from 0.3 to 19.0 adducts/10(7) nucleotides) than the tissues from the nonsmokers (0.3 to 3.7 adducts/10(7) nucleotides) in two separate experiments. Among the tissues from smokers, heart showed the highest level of DNA adducts. This study demonstrates that a stable color ELISA with high sensitivity can be useful in assessing human exposure to PAH.

7,8-Dihydro-7,8-dihydroxybenzo(a)pyrene 9,10-oxide↗

Development and evaluation of an IgM-capture ELISA for detection of recent infection with bluetongue viruses in cattle.

An IgM-capture enzyme-linked immunosorbent assay (ELISA) was developed for the detection of recent infection of bluetongue virus (BTV) in cattle. The test is based on the use of biotinylated capture anti-bovine IgM antibodies bound to a streptavidin-coated ELISA plate. The captured IgM antibodies were detected by application of BTV VP7 antigen and a VP7 antigen-specific monoclonal antibody. The IgM-capture ELISA was compared with the competitive ELISA by testing serum samples from groups of calves infected experimentally with five USA and 19 South Africa serotypes of BTV. The IgM-capture ELISA was able to detect bovine anti-VP7 antibodies from all animals infected with the 24 BTV serotypes at 10 days post-infection, whereas the competitive ELISA was not. When the detectable IgM diminished after 40 days post-infection by the IgM-capture ELISA, the IgG anti-VP7 antibodies remained high. The IgM-capture ELISA is sensitive and can be applied for the detection of recent infection of BTV in cattle.

Animals↗

A solid-phase competition ELISA for measuring antibody to foot-and-mouth disease virus.

A solid-phase competition ELISA has been developed to measure antibodies to foot-and-mouth disease (FMD) virus and has been validated using an extensive range of sera from cattle. The assay uses polyclonal antisera and inactivated purified 146S antigens of FMD virus and was compared with the liquid-phase blocking ELISA and the virus neutralisation test on a range of serum sets. When examining test sera at a 1:5 dilution with a cut-off point of 30% inhibition of reaction, the solid-phase competition ELISA was as sensitive as the liquid-phase blocking ELISA for sera from infected or vaccinated animals. The limit of detection of the solid-phase ELISA was similar to that of the liquid-phase assay and both tests had lower limit of detection (i.e. were able to detect lower amounts of antibody) than the virus neutralisation test. The specificity of the solid-phase ELISA was considerably higher than that of the liquid-phase blocking ELISA and almost equivalent to that of the virus neutralisation test. The assay thus retains the sensitivity of the liquid-phase blocking ELISA whilst being easier to use, more robust and specific, and therefore offers an improvement for FMD virus antibody detection.

Animals↗

HPV antibody detection by ELISA with capsid protein L1 fused to glutathione S-transferase.

An alternative enzyme linked immunosorbent assay (ELISA) system was developed to analyze antibodies to human papillomavirus capsid antigens. The assay uses glutathione crosslinked to casein to capture the major capsid protein L1 from human papillomavirus (HPV) types 6b, 16 and 18 fused to glutathione S-transferase (GST) as antigen. The method allows efficient one-step purification of L1 fusion protein from crude bacterial lysates on ELISA plates coated with glutathione casein. The GST-L1 capture ELISA detected HPV 16 antibodies with high type specificity. Comparison with the current "gold-standard" for L1-serology that uses virus-like particles (VLP) as antigen demonstrated similar assay sensitivity. Pairwise comparison of the absorbance values of 105 human sera obtained in the two ELISA formats for HPV 16 showed a R(2) value of linear regression of 0.68. Conformity of the two ELISAs in classification of sera as HPV 16 L1 antibody-positive or -negative was verified with Cohen's kappa test, yielding a value of 0.62. These data indicate that the GST-L1 capture ELISA is similar in performance to the VLP ELISA. The ease of antigen production and purification in the GST-based ELISA will be advantageous to screen large sample numbers in vaccine trials or epidemiological studies examining immune responses to many HPV types in parallel.

Animals↗

Development of competitive ELISA for serodiagnosis on African horsesickness virus using baculovirus expressed VP7 and monoclonal antibody.

VP7, the sero-group common antigen, of African horsesickness virus (AHSV-4) was expressed in insect cells by recombinant baculovirus. To develop a specific diagnostic method, monoclonal antibody (Mab) against VP7 was prepared and investigated as diagnostic reagent with the baculovirus expressed VP7. However, the Mab against VP7 of AHSV cross-reacted with Chuzan virus by the indirect immunofluorescence assay (IFA), confirming the presence of conserved domain of VP7 among Orbiviruses. This study describes two types of ELISA; Mab linked indirect (I-ELISA) and competitive-ELISA (C-ELISA) using baculovirus expressed VP7 as an antigen. These ELISAs were compared for serodiagnosis of AHSV showing that C-ELISA was more specific than I-ELISA. The results indicated that C-ELISA is applicable to serodiagnosis of AHSV regardless of serotypes.

African Horse Sickness↗

Evaluation of monoclonal antibodies for generic detection of flaviviruses by ELISA.

Three monoclonal antibodies (Mabs) specific for the envelope (E) protein of flaviviruses were evaluated for use in an antigen capture ELISA. Three combinations of Mabs and a combination of polyclonal antibodies (Pabs) were evaluated in antigen capture ELISAs for their ability to detect 18 flaviviruses. The Mab ELISAs detected 50% of flavivirus antigens with a sensitivity between 1 and 9 x 10(4)/ng viral protein/ml, however, none of the ELISAs evaluated proved to be useful for generic detection of flaviviruses, being unable to detect tick-borne flaviviruses and some mosquito-borne flaviviruses. The inability of the ELISAs to detect tick-borne flaviviruses is thought to be due to the conformation of surface epitopes, which the Mabs were unable to recognise. This was again observed using recombinant TBE virus prM/E protein as antigen in direct and antigen capture ELISAs. The Mabs reacted with the prM/E protein when it was denatured by binding directly onto the solid phase, but the antibodies were unable to detect the native protein in antigen capture ELISAs. The antigen capture ELISAs evaluated in this study were considered to be unsuitable for the generic detection of flaviviruses, but may provide a sensitive diagnostic assay for specific flavivirus infection.

Animals↗

Culture amplification in human colon adenocarcinoma cell line (CaCo-2) combined with an ELISA as a supplementary assay for accurate diagnosis of rotavirus.

Culture amplification in colon adenocarcinoma cell line (CaCo-2) combined with enzyme immunoassay (Pathfinder ELISA) was developed as a supplementary tool for rotavirus diagnosis. One hundred and thirty stools in which results by polyacrylamide gel electrophoresis (PAGE) were in agreement with those obtained by ELISA were amplified in the CaCo-2 cell line. After the first passage 100% specimens were revealed as positive by ELISA. This result was confirmed by PAGE and direct electron microscopy (EM) which increased the rates of rotavirus detection up to 100% after the third and fifth cell passages, respectively. All of the amplified negative stools were confirmed as negative. Among discordant results, three of the eight specimens positive by ELISA but negative by PAGE were confirmed as true positive after the third cell passage. False positive ELISA results could be discarded when the samples were culture amplified and retested by the same ELISA. Using the CaCo-2 amplification-ELISA as supplementary assay, sensitivity and specificity were 1.000 and 0.953 for ELISA and 0.917 and 1.000 for PAGE, respectively. The combined CaCo-2 cell line amplification-immunoassay method proved to be suitable both to evaluate increase in sensitivity of newly developed rotavirus assays and for rotaviral amplification before antigen assays.

Caco-2 Cells↗

The Mycobacterium avium subsp. paratuberculosis ELISA response by parity and stage of lactation.

Two cross-sectional studies were carried out to determine the enzyme-linked immunosorbent assay (ELISA) response to Mycobacterium avium subsp. paratuberculosis (Map) by cow characteristics and stage of lactation. One of the studies (referred to as "milk-group") used milk samples from all lactating cows (n=7994) in 108 Danish dairy herds. The other study (referred to as "serum-group") used serum samples collected from all cows (n=5323) in a subset of 72 herds from the 108 herds. These samples were analysed using a similar ELISA for detection of antibodies. The results from the ELISAs were interpreted with two cut-off values as the optimal cut-off value is not known, and as several levels are recommended to be used in practice. The results showed that the probability of being ELISA-positive was two to three times lower for cows in parity 1 relative to cows in other parities using both milk and serum ELISA. At the beginning of the lactation the probability of being positive was highest in the milk ELISA. In the serum ELISA the odds of being positive was highest at the end of lactation. The findings are important in the interpretation of ELISA results at cow level with a subsequent tentative diagnosis and correction for parity and stage of lactation should be considered when providing a diagnosis of paratuberculosis. Some issues related to the pathogenesis are also discussed.

Animals↗

Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle.

A milk and a serum ELISA for detection of antibodies against Mycobacterium avium ssp. paratuberculosis (MAP) were evaluated against the complement-fixation test (CFT) and culture of faecal samples from 580 cows collected between August 1996 and December 1996. Milk and serum were obtained concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP.A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4, 7 and 17 OD%.

Animals↗

Enzyme-linked immunosorbent assay (ELISA) with covalently bound protein on glass tubes: 1. Stable antigenicity and binding of IgG as a model antigen after repeated use.

A modification of the ELISA procedure is described. The system is based on the covalent binding of protein to glass tubes. Human IgG was used as model antigen. Optimal conditions were tested for the removal of alkaline phosphatase-labeled antibodies from their antigen. Under such optimal conditions, a regenerable system could be created which exhibited many advantages, as compared with conventional ELISAs with antigens absorbed unspecifically to plastic surfaces. The advantages are: 1. A higher density of IgG as model antigen on the solid phase, i.e., 1 molecule IgG per 94 nm2 with glass tubes as compared with 110 nm2 with polystyrene (PS) or 143 nm2 with polyvinylchloride (PVC) microtiter plates. 2. A much smaller unspecific absorption of less than 1% as compared with 39% with PS-plates or 16% with PVC-plates treated under identical conditions. 3. A higher stability of the binding of the model antigen to the solid phase, i.e., a drastically reduced protein loss of less than 6% during the first ELISA procedure (including the regeneration) and of less than 1% during the subsequent ELISA and regeneration cycles with glass tubes as compared with 46% (PS plates) or 55% (PVC plates). 4. A smaller intraday variation coefficient of the ELISAs of 4.8% with glass tubes as opposed to 9.7% or 7.5% with PS or PVC plates respectively. The system with covalently bound antigens on glass tubes could be used in at least 20 consecutive measuring cycles. In five consecutive cycles, a protein loss of less than 5% was observed and the interday variation coefficient of the ELISA reaction was smaller than 5% using the same tubes repeatedly. Our results indicate that covalent linkage of protein can improve ELISA and lead to repeatedly usable systems as long as the antigen is stable against the regeneration procedure. Such an ELISA system may be helpful with highly purified proteins.

Adsorption↗

Development of a foot-and-mouth disease NSP ELISA and its comparison with differential diagnostic methods.

The gene encoding the nonstructural protein (NSP) of O/SKR/2000 foot-and-mouth disease virus (FMDV) was constructed to express under the polyhedron promoter of baculovirus. The expression of NSP was confirmed by indirect immunofluorescence assay (IFA) and Western blotting. The expressed NSP was applied as a diagnostic antigen for indirect-trapping ELISA (I-ELISA). An I-ELISA using monoclonal antibody (Mab) against 3A as trapping antibody was developed to differentiate infected from vaccinated cattle. The diagnostic efficiency of Mab linked I-ELISA was compared and evaluated with baculovirus expressed 3ABC I-ELISA from USDA and Mab (3A) linked E. coli expressed 3ABC I-ELISA from IZSLE through retrospective sero-surveillance. Compared with the two different I-ELISA methods, Mab (3A) linked I-ELISA using baculovirus expressed NSP showed the same level of sensitivity and specificity, indicating that this method is suitable for a differential diagnostic method in cattle.

Animals↗

Evaluation of an antibody-ELISA using five crude antigen preparations for the diagnosis of Trypanosoma evansi infection in cattle.

Attempts were made to improve the accuracy of an antibody-detection ELISA for the detection of Trypanosoma evansi infection in cattle by improving the method of preparation of the crude antigen used. An IgG-ELISA was performed with five different antigen preparations: crude soluble antigen, soluble and insoluble fractions of crude antigen treated with 0.1% formalin and whole formalin-fixed trypanosomes treated with either trypsin or 2-mercaptoethanol. An IgM-ELISA using crude soluble antigen was also performed. Each ELISA was evaluated using serum from 44 Indonesian cattle infected with T. evansi and 262 uninfected cattle from Australia. There was no significant difference between the sensitivity or specificity of the IgG-ELISA using each of the five antigens. The IgM-ELISA using a crude untreated lysate was significantly less sensitive (p<0.05) than the IgG-ELISA using the same antigen, trypsin-treated antigen or the 0.1% formalin-treated soluble antigen (68, 64 and 64%, respectively). These results show that these modifications to the method of producing crude antigens for the Ab-ELISA does not improve the accuracy of diagnosis of T. evansi infection in cattle.

Animals↗

Development and validation of a monoclonal antibody blocking ELISA for the detection of antibodies against both equine herpesvirus type 1 (EHV1) and equine herpesvirus type 4 (EHV4).

A monoclonal antibody blocking ELISA was developed for the detection of antibodies directed against either EHV1 or EHV4. For this purpose, we selected a monoclonal antibody directed against a cross-reactive, conservative and immunodominant epitope of both EHV1 and EHV4. High antibody titres were found in rabbit antisera and SPF-foal antisera infected with either EHV1 or EHV4. After experimental challenge of conventional horses with EHV1 or EHV4 significant increases in CF and ELISA titres were found, whereas VN antibodies did not always increase significantly. In 344 paired serum samples submitted for diagnostic purposes a good agreement (kappa = 0.75, confidence limits = 0.63-0.88) was found between VN test and ELISA regarding a significant increase in titres. Also, a good correlation was found between VN and ELISA titres (r = 0.76, p<<0.0005). The relative sensitivity and specificity of the Mab blocking ELISA as compared with the VN test were 99.9 and 71%, respectively. The rather low relative specificity of the ELISA may be explained by a relatively low sensitivity of the VN test. The ELISA also detected increases in titre after vaccination with an EHV1 subunit vaccine, and after primary field infections in weaned foals. We concluded that the Mab blocking ELISA is more sensitive, easier to perform, more rapid and more reproducible than the VN test. We consider this test as a valuable tool for serological diagnosis of both EHV1 and EHV4 infections.

Animals↗