Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Data Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

The function of sensory nerve fibers in lumbar radiculopathy. Use of quantitative sensory testing in the exploration of different populations of nerve fibers and dermatomes.

STUDY DESIGN: The function of sensory nerve fibers in patients with lumbar radiculopathy and in control individuals was evaluated using quantitative sensory testing. OBJECTIVES: To investigate the effect of lumbar nerve root compression on different populations of nerve fibers and to explore the function of sensory nerve fibers in neighboring nerve roots not involved in the mechanical compression. BACKGROUND DATA: Results from experimental and clinical studies indicate that chronic compression of lumbar nerve roots affects the large myelinated nerve fibers. The majority of nerve fibers involved in the sensation of pain, however, are small afferent nerve fibers. It is therefore of interest to study the effect of compression on large and small sensory afferent channels. Several authors have elucidated the biochemical interaction between disc tissue and nerve roots. Chemical substances in the epidural space can reach the nerve fibers in nerve roots at the same or neighboring lumbar segments. In this way, fibers not involved in the mechanical compression may be affected. METHODS: The small nerve fibers were studied using tests for thermal thresholds (thermotest), and the large myelinated fibers were studied by vibrametry. Forty-two patients were investigated in the symptomatic and the asymptomatic leg, and the results were compared with those of 21 healthy individuals. RESULTS: The thresholds of cold, warmth, and vibration were significantly increased in the dermatome of the compressed nerve root, indicating that large and small sensory nerve fibers were affected. Further, the thresholds were significantly increased in the neighboring dermatomes in the symptomatic and the asymptomatic leg. CONCLUSION: Large and small sensory afferent nerve fibers are affected in lumbar radiculopathy. The increase in sensation thresholds in the ipsilateral neighboring dermatome and in the dermatomes in the asymptomatic leg indicates that adjacent nerve roots are involved in the pathophysiology of sciatica in patients with lumbar disc herniation.

Adult↗

Factors affecting performance of PACS.

We experimentally constructed a personal-computer-based Picture Archiving and Communication System (PACS) for color images of dermatology clinics. This system should especially satisfy such a demand as to be able to retrieve an image within a few seconds from the database residing in a remote server. Our two objectives in the experiment were: To examine how much time was consumed in each part of PACS while it does a series of jobs, from the requesting of an image to its display on the screen of the workstation of the user. The other objective was to see if a personal-computer-based PACS could satisfy our criteria. Total retrieving time, data reading time, data transporting time and image displaying time were measured. Total retrieving time can be divided into three procedures: Data reading time, data transporting time, image displaying time. Data reading time was about 0.6 second for reading an image with the size of 1 mega bytes (MB). Data reading time and the size of data were linearly correlated. Data transporting time was about 11 seconds for transporting an image with the size of 1 MB through EtherTalk, and 66 seconds through LocalTalk. Data transporting time and the size of the data were also linearly correlated. Data reading time and data transporting time was able to be reduced largely by compression technique. However, smaller data give other important effects to the network system besides reducing the time of data reading, data transporting and data displaying. Most Local Area using image Network (LAN) systems, such as EtherTalk, adopt Carrier Sense Multiple Access with Collision Detection (CSMA/CD) for the way of accessing to other computer. In CSMA/CD, transporting performance suddenly declines if the congestion of signal in a network gets beyond a critical level. This situation fatally impairs the performance of a network. We concluded that data compression plays an important role to improve the performances of PACS, especially those of a server and the network system. A personal-computer-based PACS with EtherTalk and an image compression/decompression hardware, e.g., CL550A chip, satisfies our criteria.

Dermatology↗

Compression of nucleic acid and protein sequence data.

This paper describes the application of text compression methods to machine-readable files of nucleic acid and protein sequence data. Two main methods are used to reduce the storage requirements of such files, these being n-gram coding and run-length coding. A Pascal program combining both of these techniques resulted in a compression figure of 74.6% for the GenBank data-base and a program that used only n-gram coding gave a compression figure of 42.8% for the Protein Identification Resource database.

Algorithms↗

Effect of the Harrington compression system on the correction of the rib hump in spinal instrumentation for idiopathic scoliosis.

To analyze the effect of the Harrington compression system on the rib hump in thoracic idiopathic scoliosis, intraoperative measurements were made on 21 cases during correction with the distraction system and after addition of the compression system. The data show that the compression system makes a major contribution to the correction of total rib deformity in over two-thirds of the patients, and the correction of the rib valley is much more significant than correction of the rib hump. Analysis of postoperative spine roentgenograms seems to indicate that the extent of the rib correction does not correlate with spine derotation as measured by the system of Nash and Moe. The improvement in rib correction achieved by addition of the compression system appears to result from changes centered about the costovertebral joints.

Adolescent↗

Hydration and partial compressibility of biological compounds.

We review the results of compressibility studies on proteins, nucleic acids, and systematically altered low molecular weight compounds that model the constituents of these biopolymers. The model compound data allow one to define the compressibility properties of water surrounding charged, polar, and nonpolar groups. These results, in conjunction with compressibility data on proteins and nucleic acids, were used to define the properties of water that is perturbed by the presence of these biopolymers in aqueous solutions. Throughout this review, we emphasize the importance of compressibility data for characterizing the hydration properties of solutes (particularly, proteins, nucleic acids, and their constituents), while describing how such data can be interpreted to gain insight into role that hydration can play in modulating the stability of and recognition between biologically important compounds.

Animals↗

Compression guidelines for diagnostic telepathology.

As the healthcare community has begun to rely increasingly upon digital technologies for acquisition, storage, and transmission of pictorial data, image compression has become an indispensable tool. We have investigated the feasibility of lossy compression in a well-defined task domain, the clinical assessment of digitized images of chromatic microscopic pathology specimens. The effect of compression was measured under two distinct perceptual criteria, just noticeable difference (j.n.d.) and largest tolerable distortion (l.t.d.), differing in the involvement required from subjects, who were experts in pathology. For standard JPEG compressed images it was found that when the experiment is performed under the l.t.d. criterion, a significantly larger compression ratio is reported as satisfactory. It is concluded that lossy compression holds promise for diagnostic telepathology.

Algorithms↗

Compression-induced degeneration of the intervertebral disc: an in vivo mouse model and finite-element study.

STUDY DESIGN: An in vivo study of the biologic and biomechanical consequences of static compressive loading on the mouse tail intervertebral disc. OBJECTIVES: To determine whether static compression in vivo alters the biologic activity of the disc and leads to diminished biomechanical performance. SUMMARY OF BACKGROUND DATA: Static compressive stress that exceeds the disc's swelling pressure is known to change hydration and the intradiscal stress distribution. Alterations in hydration and stress have been associated with changes in disc cell activity in vitro and in other collagenous tissues in vivo. METHODS: Mouse tail discs were loaded in vivo with an external compression device. After 1 week at one of three different stress levels, the discs were analyzed for their biomechanical performance, morphology, cell activity, and cell viability. A second group of mice were allowed to recuperate for 1 month after the 1-week loading protocol to assess the disc's ability to recover. As an aid to interpreting the histologic and biologic data, finite-element analysis was used to predict region-specific changes in tissue stress caused by the static loading regimen. RESULTS: With increasing compressive stress, the inner and middle anulus became progressively more disorganized, and the percentage of cells undergoing apoptosis increased. The expression of Type II collagen was suppressed at all levels of stress, whereas the expression of aggrecan decreased at the highest stress levels in apparent proportion to the decreased nuclear cellularity. Compression for 1 week did not affect the disc bending stiffness or strength but did increase the neutral zone by 33%. As suggested by the finite-element model, during sustained compression, tension is maintained in the outer anulus and lost in the inner and middle regions where the hydrostatic stress was predicted to increased nearly 10-fold. Discs loaded at the lowest stress recovered anular architecture but not cellularity after 1 month of recuperation. Discs loaded at the highest stress did not recover anular architecture, displaying islands of cartilage cells in the middle anulus at sites previously populated by fibroblasts. CONCLUSIONS: The results of the current project demonstrate that static compressive loading initiates a number of harmful responses in a dose-dependent way: disorganization of the anulus fibrosus; an increase in apoptosis and associated loss of cellularity; and down regulation of collagen II and aggrecan gene expression. The finite element model used in this study predicts loss of collagen fiber tension and increased matrix hydrostatic stress in those anular regions observed to undergo programmed cell death after 1 week of loading and ultimately become populated by chondrocytes after one month of recuperation. This correspondence conforms with the suggestions of others that the cellular phenotype in collagenous tissues is sensitive to the dominant type of tissue stress. Although the specific mechanisms by which alterations in tissue stress lead to apoptosis and variation in cell phenotype remain to be identified, our results suggest that maintenance of appropriate stress within the disc may be an important basis for strategies to mitigate disc degeneration and initiate disc repair.

Aggrecans↗

RSHash: a fast and space-efficient hash table for k-mers.

SUMMARY: Large genomic data collections can be viewed as a continuous string of DNA characters. The essential operations for data structures indexing the k-mer content of such a string are lookup and locate. Lookup determines whether a query k-mer q exists in the string and locate returns all locations in the string where q is present. High-throughput DNA sequencing generates very many k-mer sets of size exceeding billions of characters. In such scenarios, memory consumption and query efficiency pose significant challenges to a data structure supporting the above mentioned queries. To address this problem, we describe a simple, compressed, static data structure for k-mers that answers lookup and can be extended for supporting locate. The general scheme follows the use of minimizers like the state-of-the art SSHash. However, instead of using minimum perfect hash functions our solution (RSHash for Rank-Select Hash) relies on bitvectors with rank and select support, a multiple layered minimizer scheme, and a clever buffering strategy. We can show that RSHash is on average 40% and in some cases up to two times faster than SSHash while having the same memory requirements. Indeed we can go as low as 8 bits per canonical 31-mer on a human dataset. AVAILABILITY: https://github.com/jonsmcode/rshash.

Sequence Analysis, DNA↗

[Simplification of gamma-ray spectral data by using Fourier transform].

A method is proposed to represent gamma-ray response spectra by Fourier series for the purpose of compressing spectral data. The usefulness of the method was confirmed by applying it to a spectral library of a NaI detector. In the method, a response spectrum as a wave is described by superposition of sine (cosine) waves with low frequencies, whose coefficient parameters can be obtained by a Fast Fourier Transform program. The relation between the number of parameters and the fitting error is discussed, and as the result, it is shown that the number of parameters can be reduced to about a half. The merits and features are presented in practical application of the method to the analysis of gamma-ray spectra.

Fourier Analysis↗

Effect of fitting adjustments on compressive strength of a new foil crown system.

The effect of die spacing and precementation internal adjustments on the compressive strength of a new ceramic foil crown system was examined in vitro. Twenty-four ceramic foil crowns were made for identical stylized master dies made of polycarbonate filled with 30 wt% carbon. One half of the stone working dies were coated with die spacer and the remaining were left untreated. A special foil used for these crowns was adapted to the working dies under 2500 psi loading. A sculpturing device was used to standardize the size and shape of the ceramic foil crowns. Only crowns made on dies coated with die spacer received precementation fitting adjustment. All crowns in the two groups were cemented with zinc phosphate cement and were subjected to compressive force until fracture occurred. Compressive strength data were analyzed and compared. Results showed that the use of die spacer and internal adjustments increased the compressive strength of the new ceramic foil crown.

Crowns↗

Wavelet transform-based image compression for transmission of MR data.

OBJECTIVE: The purpose of this study was to develop an effective, inexpensive teleradiology image-transmission system for transfer of MR studies using wavelet transform image compression. CONCLUSION: We describe an efficient system for implementing teleradiology capability for transmission of diagnostic MR images. The system uses the wavelet transform to achieve greater than 90% image compression, with standard modern transmission times of less than 5 sec per compressed image. The method is inexpensive and can be implemented using commonly available workstation and MR scanner capabilities.

Brain↗

Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering.

We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image--ordinarily used to update image estimates in plain OSEM--is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software.

Algorithms↗

Trends in future urodynamics: computer support-data base-digitized imaging.

The use of computers in urodynamics must be based preferably on the structure of the urodynamic investigation itself. This enables implementation of computerized systems in the urodynamic laboratory in the most natural way and provides transparency of urodynamic software for the investigators. Additionally, the algorithms of the urodynamic software then can provide for a urodynamic investigation following a logical path based on the patient's history and clinical data and (automatically interpreted) results from earlier steps in the urodynamics. As an extension of this structured logical reasoning, the computer use in urodynamics can be extended to include validation and decision rules, comprising measurement data and rules for interpretation and combination of history, clinical and measurement data. Conclusions will be presented then in the form of a preliminary differential diagnosis, including the odds for each of the possible diagnoses. These kinds of computerized interpretation systems will be validated by comparison with the classical clinical diagnoses and are generally known as expert systems. These systems rely on logical branching-as opposed to systems that are statistical in nature and use large data bases to classify individual data into known groups. Data bases will remain for the purpose of documentation, based on individual patients and comprising all patient data-comparable to the existing patient files in the hospital's archives. The computer files have to include also the original data from functional studies like urodynamics-and not just the abstracted conclusions-and from imaging techniques. Intelligent compression of data prevents the data bases from exploding. Digital imaging techniques combined with computerized urodynamic investigations open possibilities for dynamic analysis of morphologic data and combination thereof with urodynamic measurement data.

Databases, Factual↗

Adaptation of bulk constitutive equations to insoluble monolayer collapse at the air-water interface.

A constitutive equation based on stress-strain models of bulk solids was adapted to relate the surface pressure, compression rate, and temperature of an insoluble monolayer of monodendrons during collapse at the air-water interface. A power law relation between compression rate and surface pressure and an Arrhenius temperature dependence of the steady-state creep rate were observed in data from compression rate and creep experiments in the collapse region. These relations were combined into a single constitutive equation to calculate the temperature dependence of the collapse pressure with a maximum error of 5 percent for temperatures ranging from 10 degrees to 25 degrees C.

Air↗

Saccular aneurysm of the transverse thoracic aorta detected by transesophageal echocardiography.

A patient with a saccular aneurysm of the thoracic aortic arch presented with severe right ventricular failure due to pulmonary artery compression. Contradictory data were derived from computed tomography, pulmonary isotope perfusion scan and cardiac catheterization. Transesophageal echocardiography revealed a saccular aneurysm which compressed the main pulmonary artery and gave access to a fistulous connection to the left pulmonary artery. Surgery confirmed these findings.

Aorta, Thoracic↗

Load-carrying capacity of the human cervical spine in compression is increased under a follower load.

STUDY DESIGN: An experimental approach was used to test human cadaveric cervical spine specimens. OBJECTIVE: To assess the response of the cervical spine to a compressive follower load applied along a path that approximates the tangent to the curve of the cervical spine. SUMMARY OF BACKGROUND DATA: The compressive load on the human cervical spine is estimated to range from 120 to 1200 N during activities of daily living. Ex vivo experiments show it buckles at approximately 10 N. Differences between the estimated in vivo loads and the ex vivo load-carrying capacity have not been satisfactorily explained. METHODS: A new experimental technique was developed for applying a compressive follower load of physiologic magnitudes up to 250 N. The experimental technique applied loads that minimized the internal shear forces and bending moments, loading the specimen in nearly pure compression. RESULTS: A compressive vertical load applied in the neutral and forward-flexed postures caused large changes in cervical lordosis at small load magnitudes. The specimen collapsed in extension or flexion at a load of less than 40 N. In sharp contrast, the cervical spine supported a load of up to 250 N without damage or instability in both the sagittal and frontal planes when the load path was tangential to the spinal curve. The cervical spine was significantly less flexible under a compressive follower load compared with the hypermobility demonstrated under a compressive vertical load (P < 0.05). CONCLUSION: The load-carrying capacity of the ligamentous cervical spine sharply increased under a compressive follower load. This experiment explains how a whole cervical spine can be lordotic and yet withstand the large compressive loads estimated in vivo without damage or instability.

Cadaver↗

Measurements of bone strain in foals with altered foot balance.

Two to 7 days after birth, 9 foals were anesthetized, and strain gauges were applied to lateral and medial aspects of the third metacarpal bone of the left forelimb. In 5 of these foals, strain gauges also were applied to the radius of the left forelimb. Four to 6 days later, foals were walked (5 sets of 10 to 20 strides), and compressive and tensile strains in the bone beneath strain gauges were recorded on paper and diskette. After recording base-line data, a wedge was fitted to the hoof of the limb with the strain gauges, in such a way that the lateral bearing surface was raised, and strains were recorded again. The wedge was left in place, and further recordings were made every 2 to 3 days for 10 days. At the normal walk (base-line data), the compressive strain was higher than the tensile strain in the third metacarpal bone, on the medial side of which the mean principal compressive strain was approximately twice that on the lateral surface. Immediately after application of the wedge, strain values from the medial surface of the third metacarpal bone decreased by 40%, and the lateral surface compressive strain increased by 100%. These changes gradually decreased over 10 days, at which time there was no significant difference from base-line values (P less than 0.05). Similar but much less obvious trends were observed in the radius. Abnormal hoof balance apparently had no lasting effect on compressive forces running through the limb, and the natural situation of higher compressive strain medially was restored quickly.

Animals↗

Video on the Internet: An introduction to the digital encoding, compression, and transmission of moving image data.

In this paper, we seek to provide an introduction to the fast-moving field of digital video on the Internet, from the viewpoint of the biological microscopist who might wish to store or access videos, for instance in image databases such as the BioImage Database (http://www.bioimage.org). We describe and evaluate the principal methods used for encoding and compressing moving image data for digital storage and transmission over the Internet, which involve compromises between compression efficiency and retention of image fidelity, and describe the existing alternate software technologies for downloading or streaming compressed digitized videos using a Web browser. We report the results of experiments on video microscopy recordings and three-dimensional confocal animations of biological specimens to evaluate the compression efficiencies of the principal video compression-decompression algorithms (codecs) and to document the artefacts associated with each of them. Because MPEG-1 gives very high compression while yet retaining reasonable image quality, these studies lead us to recommend that video databases should store both a high-resolution original version of each video, ideally either uncompressed or losslessly compressed, and a separate edited and highly compressed MPEG-1 preview version that can be rapidly downloaded for interactive viewing by the database user.

Algorithms↗