Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Blood Specimen Collection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Relative values of the interventions of diversion and improved donor-arm disinfection to reduce the bacterial risk from blood transfusion.

BACKGROUND AND OBJECTIVES: The aim of this study was to demonstrate the efficiency of diverting the initial 20-ml donation from the collection bag and of an improved donor-arm disinfection procedure in reducing bacterial contamination in blood. MATERIALS AND METHODS: Donations were collected in bags specially manufactured for the study. These bags incorporated two satellite pouches into each of which 20 ml of blood was collected. Blood initially flowed into sample pouch P1, representing a diversion pouch. Pouch P2 was then filled with 20 ml of blood, which allowed us to sample the collection bag after diversion was complete. Blood then flowed into the standard collection bag. The contents of the pouches were aerobically and anaerobically cultured on the BacT/ALERT automated culture system for 7 days. Two procedures were investigated in the study (each involving 1409 blood donations): one analysed the current disinfection procedure; and the other analysed an improved donor-arm disinfection procedure. RESULTS: The use of diversion alone resulted in a 47% reduction in contamination, and improved donor-arm disinfection alone resulted in a 57% reduction in contamination. Diversion plus improved donor-arm disinfection produced a predicted 77% reduction in contamination. CONCLUSIONS: The study validates diversion and an improved donor-arm disinfection procedure. In combination, these two interventions produced a substantial reduction in contamination. These procedures are to be introduced by the English National Blood Service to enhance the safety of the blood supply.

2-Propanol↗

Effects of different sampling methods for measurement of post dialysis blood urea nitrogen on urea kinetic modeling derived parameters in patients undergoing long-term hemodialysis.

A simple and reliable sampling method for measuring post-dialysis blood urea nitrogen (C2) has not been well established. Therefore, the effects of different methods of sampling C2 on calculating urea kinetic modeling (UKM) derived parameters were studied in patients on hemodialysis. At first, C2 values were sampled at the end of hemodialysis at a blood flow rate of 300 ml per min (blood flow rate (Qb) 300 ml per min). They were then divided into two groups. In group 1 (n = 11), C2 samples were taken after slowing down Qb to 100 ml per min for 3 min (C2-100); the blood pump was then stopped for 1 min, and C2 was again sampled (C2-100-stop). Finally, C2 was sampled with Qb restored to 100 ml per min and the venous line clamped for another 12 sec (C2-100-clamp). In group 2 (n = 11), C2 samples were collected after Qb was slowed down to 50 ml per min for 3 min (C2-50), and C2-50-stop was then measured. Finally, C2-50-clamp was measured. Using C2-clamp as a reference standard, UKM parameters were calculated using a variable volume, single pool UKM. The authors found that Kt/V calculated by C2-300, C2-100, and C2-50 overestimated the reference Kt/V by 8.4-9.1%, 5.1%, and 3%, respectively. In contrast, protein catabolic rate and time-averaged BUN were affected only minimally. Therefore, a low flow technique with a Qb of 50 ml per min for 3 min can be used for the routine estimation of C2 and UKM-derived parameters with reasonable accuracy.

Blood Flow Velocity↗

The effect of plasma retransfusion on the blood pressure in the puerperium.

Whole blood was collected from five patients with severe pre-eclampsia, three with mild pre-eclampsia, and three with normal uneventful pregnancies. The red cells were separated and replaced. The plasma was stored until after the patients were delivered and on the sixth postpartum day they were autotransfused with plasma. This caused a rise in blood pressure in the patients with pre-eclampsia but an aliquot which was stored for six weeks and then retransfused into these patients did not cause any change in blood pressure. No blood pressure changes were found in the normal control subjects at six days or six weeks post partum. It is postulated that patients with pre-eclampsia develop altered vascular sensitivity to normal amounts of circulating pressor substance and that his sensitivity lasts for a week after delivery but not as long as six weeks.

Adolescent↗

Umbilical cord blood processing with the Optipress II blood extractor.

BACKGROUND: We have previously shown that UC blood (UCB) units can be volume-reduced manually, in a closed system, without major losses of nucleated and CD34(+) cells and without the addition of exogenous material. Our aim was to use an automated method for the separation of the UCB components using the Optipress II, extractor, with the 'buffy-coat' collection in a standardized volume. METHODS: After centrifugation, the 51 UCB units were separated into the three blood components, plasma, buffy coat (BC) and red cells, using the Optipress II. The final volume of the BC fraction, rich in nucleated and progenitor CD34(+) cells, was set at 30 mL. The nucleated and CD34(+) cell content of the UCB collections and the resulting BC were evaluated. RESULTS: The UCB units were grouped according to the volume collected: Group I < 80 mL and Group II > or = 80 mL. Standardization of the BC at 30 mL resulted in significant volume reduction for both groups, with median values of 51% in Group I and 70% in Group II. The nucleated and CD34(+) cell recoveries in the BC from Group I were 88% and 99% respectively; for Group II they were 80% and 97%. DISCUSSION: This semi-automated method of volume reduction efficiently reduces low, as well as high volume UCB units, with good nucleated- and progenitor-cell yields. Being a closed system and free of external material, the risk of contamination is minimized. The resulting fractions are then available for validation studies of the unit, effectively fulfilling the main requisites for UCB banking.

Automation↗

Autologous blood collection in abdominal vascular surgery. Assessment of a low pressure blood salvage system with particular reference to the preservation of cellular elements, triglyceride, complement and bacterial content in the collected blood.

A simple, low pressure, blood scavenging system has been assessed in major abdominal vascular operations. The aim of this study was to assess the quality of blood obtained with this device and its suitability for reinfusion. Three areas of special interest, which have not been reported so far, are the fate of plasma complement, the load of fat aspirated after tissue dissection and the degree of bacterial contamination in the scavenged blood. The development of autologous blood scavenging systems is reviewed. The features which most affect the quality of scavenged blood are identified and their importance discussed by comparison with our experience. Key features of our system were: simplicity of the apparatus, controlled low-pressure aspiration, the use of systemic heparin and the avoidance of mechanical pumps. The blood obtained was of excellent quality with good preservation of cellular elements, platelets and fibrinogen. Plasma total haemolytic complement, C3 and C4 fractions were preserved in normal, though slightly reduced, quantities. Lipid (triglyceride) content was minimally increased after filtration. Bacterial contamination was present in all cases, but at a very low level provided that aspiration was limited to the peritoneal cavity. This low-level of contamination is not thought to be of great significance; its origin and importance are discussed.

Abdomen↗

Variation in blood sample collection for determination of hemodialysis adequacy. Council on Renal Nutrition National Research Question Collaborative Study Group.

Inadequate dialysis has been associated with high morbidity and mortality in end-stage renal disease (ESRD) patients receiving maintenance hemodialysis. The accurate estimation of dialysis adequacy, measured either as a calculated urea kinetics (Kt/V) or a simple urea reduction ratio (URR) is dependent on the proper collection of blood samples for predialysis and postdialysis blood urea nitrogen (BUN) determination. Because no established protocol exists for blood sampling, we surveyed the study cohort of dialysis centers participating in the National Kidney Foundation Council on Renal Nutrition National Research Question Collaborative Study to determine the comparability of BUN data that were collected to calculate URR to determine adequacy of dialysis. Surveys were completed by 100% of the 202 units participating: 195 in the United States (from 43 states) and seven from Canada, treating approximately 15,000 hemodialysis patients in total. The distribution of the sample by the type of facility mirrored that of 1996 United States Renal Data System (USRDS) Annual Report facilities data. Results showed a 5.0% error in predialysis blood draw and an 8.4% to 41.6% error in the postdialysis counterpart. There was a large variability in the observed postdialysis methods in general. Dilution of predialysis sample with either heparin or saline will falsely underestimate Kt/V and URR. The presence of access-derived, recirculated blood in the postdialysis sample will falsely overestimate Kt/V and URR. Excessive delay in drawing postdialysis sample will reduce Kt/V and URR because of urea rebound. Adoption by all dialysis providers of a uniform blood sample draw procedure will result in a consistency necessary to allow reliable and valid comparison of adequacy of dialysis parameters within and between ESRD patients, units, and clinical trials.

Ambulatory Care Facilities↗

[Bacterial contamination of salvaged blood in open heart surgery: is that an airborne contamination or a normal skin flora contamination?].

We investigated sources of bacterial contamination of intraoperative salvaged blood producted by autologous transfusions device (CS; CELL SAVER 5, Heamonetics Corp., Braintree, MA). Eleven patients undergone open heart surgeries including 2 emergency operations with a median sternotomy enrolled in this study. Blood samples were drawn from salvaged blood bags. Airborne contaminants (AB) were collected by a blood agar plate put besides the operation bed for 30 minutes. The median wounds samples were collected by a swab. Bacterial growth was detected in 81.8% of salvaged blood samples. Twenty-nine bacterium were isolated from CS, 72.4% of those were Staphylococci. 9.1% of sample was positive in wound swabs. Forty bacterium were isolated from plate cultures. 65% of them were Staphylococci. Staphylococcus epidermidis and coagulase negative Staphylococcus isolated both CS and AB in the 2 cases had the same identify codes, and incubated from several AB cultures. Corynebacterium sp. is also isolated from both CS and AB cultures in other 2 same cases. In 7 out of 8 cases (87.5%), from which Staphylococci isolated in CS, the Staphylococci were cultured from AB in not the same but the other cases. In conclusion, highly incidence of the identification in identical code of Staphylococci indicated that the main source of CS contamination was highly suspected to AB.

Air Microbiology↗

Clinical usefulness of red cells preserved in protein-poor mediums.

Blood is normally collected into a combined anticoagulating and preserving medium. We performed a study to ascertain whether improvements could be made by separation of these two functions. Addition of saline-adenine-glucose solutions (40 to 100 ml per blood unit) to buffy-coat-poor red-cell concentrates allowed storage for as long as 35 days with 24-hour erythrocyte post-transfusion survival of 83 +/- 6.8 per cent (+/0 S.D.). Potassium leakage was lower, and in vitro hemolysis somewhat higher than that of whole blood. The microaggregate content after 21 days was 16 per cent of that in whole blood. In over-pressure transfusions the flow rate of red cells was the same with red-cell concentrates to which 80 to 100 ml of suspension medium had been added (hematocrit less than or equal to 60 per cent) as with whole blood. Removal of the buffy coat was essential to reduce hemolysis. We conclude that red cells can be successfully stored in a simple protein-poor medium.

Adenine↗

Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe.

BACKGROUND: The purpose of this study was to assess current practices in blood management in elective orthopedic surgery in Europe. STUDY DESIGN AND METHODS: For this 225-center prospective survey, data were collected on 3996 patients. Actual perioperative blood loss was compared to preoperative estimates. Differences in Hb levels and other outcome variables for patients receiving allogeneic versus autologous transfusions were evaluated. The probability of allogeneic transfusion based on selected predictor variables was estimated. RESULTS: A total of 2640 (67%) hip and 1305 (33%) knee arthroplasty patients were evaluated. Estimated blood loss (median, 750 mL) was significantly lower than computed blood loss (median, 1944 mL). A total of 2762 (69%) patients received transfusions, including 1393 (35%) autologous-only and 1024 (25%) allogeneic-only. The probability of allogeneic transfusion decreased with increasing baseline Hb, but differentially so for men and women. Transfusion triggers were Hb levels of 8.93 +/- 1.83 g per dL for allogeneic transfusions, and 21 percent of these occurred when the Hb level was greater than 10 g per dL. Autologous blood transfusion was associated with a significantly lower rate (1%) of wound infections than allogeneic blood transfusion (4.2%). CONCLUSION: Accurate assessment of preoperative Hb levels, better estimation of perioperative blood loss, efficient use of autologous blood, adherence to transfusion guidelines, and pharmacologic alternatives contribute to effective and comprehensive blood and anemia management.

Aged↗

Blood component fractionation: manual versus automatic procedures.

Over the last few years, quality system requirements have been introduced for blood components. The necessary compliance with standard productions will have a considerable impact on Blood Banks. The introduction of automated methods is the most satisfactory means to meet these requirements for blood component preparation. A new device has been developed to automate the fractionation of blood into components. We evaluated the efficacy of this instrument as compared to manual methods. A total of 218 units of blood have been collected, into several different commercial blood bag systems (77 into standard quadruple bag systems, 141 into bag systems with integrated in line filters), and used to evaluate the universality of the instrument. Whole blood units were processed using the Top/Top system and the Compomat G4 (Fresenius HemoCare). A separate program protocol was developed for each kind of bag. Use of the Compomat G4 resulted in a statistically significant (p<0.001) increase of the hemoglobin in filtered red cell concentrates (RCC) in comparison with the manual procedure, and a similar trend, even not statistically significant, has been observed for filtered RCC. Regardless of bag systems, we were able to observe a statistically significant increase of platelets in the platelet concentrates (PCs), when comparing automatic versus manual procedure. The automated procedure has been shown to be fast, and easy for the operators. This device reliably produces acceptable blood components, and has been shown adaptable to use with different blood bag systems.

Automation↗

The development of West Nile virus safety policies by Canadian blood services: guiding principles and a comparison between Canada and the United States.

To address the emerging threat of West Nile virus (WNV) to the blood supply, Canadian Blood Services (CBS) made a series of policy decisions that were either similar to those adopted in the United States or more stringent than policies formulated in the United States at the same time. More stringent Canadian policies included the development of an in-house WNV RNA assay, the stockpiling of frozen plasma components in the winter for transfusion in WNV-affected areas in the summer, a special recruitment campaign for red blood cell collections before the start of the 2003 WNV season, and an inventory exchange (ie, WNV-tested for untested red blood cells) initiated 2 weeks after the onset of WNV screening, as well as the implementation of targeted individual-donation WNV testing on August 2, 2004, in the absence of any positive donors or clinical cases of WNV infection in Canada. The general principles that guided CBS decision making with regard to WNV safety included application of the precautionary principle, harmonization with policies in the United States, a consideration of logistic issues, compliance with Health Canada requests, responsiveness to public expectations about transfusion safety, and transparency in decision making with timely communication to stakeholders. Before implementing WNV blood safety policies, CBS assessed their impact on blood availability. When policies were implemented, data were obtained quickly to ensure that the prior impact assessments were accurate. This review discusses the guiding principles affecting CBS policy development and compares CBS WNV safety policies to policies adopted in the United States.

Antibodies, Viral↗

Use of intraosseous blood for repeated hematologic and biochemical analyses in healthy pigs.

OBJECTIVE: To evaluate the clinical and histologic effects of repeated intraosseous (IO) needle placement in domestic pigs and determine whether blood and serum obtained intraosseously could be used for CBC and biochemical analyses. ANIMALS: 5 healthy 10-week-old pigs. PROCEDURE: An IO needle was placed in the proximomedial region of the tibia of anesthetized pigs every other week for 2 months, and IO blood was obtained for CBC and serum biochemical analyses. Results were compared with those obtained for blood collected at the same time from the auricular vein. Two weeks after the final samples were obtained, pigs were euthanatized and tibias were processed for histologic examination. RESULTS: Clinical abnormalities, including lameness, were not detected following IO needle placement. Histologic examination revealed only mild multifocal periosteal fibrosis and slight thickening of the periosteum without evidence of osteomyelitis. Chloride, creatinine, glucose, total protein, sodium, and BUN concentrations, alanine transaminase and gamma glutamyl transpeptidase activities, RBC count, mean corpuscular volume, and Hct did not significantly differ between IO and venous samples. However, aspartate transaminase activity, potassium, hemoglobin, and mean corpuscular hemoglobin concentrations, mean corpuscular hemoglobin, and platelet and WBC counts were significantly different. CONCLUSION AND CLINICAL RELEVANCE: Repeated placement of 10 needles may be a safe and clinically useful method to obtain serial blood samples from domestic pigs, particularly when other vascular sites are not accessible. Intraosseous blood can be used for many of the tests comprising CBC and serum biochemical analyses.

Animals↗

Blood donor-, apheresis-, and transfusion-related activities: results of the 1991 American Association of Blood Banks Institutional Membership Questionnaire.

Approximately 2154 regional blood centers and hospital-based blood banks and transfusion services responded to the 1991 American Association of Blood Banks Institutional Membership Questionnaire that elicited data from 1990. Information from 2144 institutions was considered valid. Questionnaire topics were donor blood collections, hemapheresis, perioperative cell salvage, component usage, and transfusion-associated diseases. Institutional members reported collecting 9.3 million units, of which 90.9 percent were for allogeneic use in the community, 6.0 percent were for autologous use, and 3.1 percent were directed donations. The percentage of directed-donor units that were crossed over for allogeneic use (51%) was greater than the percentage of units transfused to the designated patient (49%). Only 12.5 percent of institutions reported obtaining specific consent for transfusion. Of the 15.4 million transfused blood components, 8.5 million were red cells, 4.1 million were platelets, 1.8 million were fresh-frozen plasma, and 0.9 million were cryoprecipitate. There were 1263 reported cases of transfusion-associated hepatitis. Approximately 44 percent of the patients who were tested proved positive for hepatitis B surface antigen, and 80 percent of the patients who were tested proved positive for antibody to hepatitis C. The questionnaire's aggregate results can be used to assess current patterns of blood donation and transfusion activities.

Acquired Immunodeficiency Syndrome↗

Oxygen carriers: a selected review.

The most common and widely transplanted tissue world wide is blood, which in 2000 resulted in the transfusion of 12.5 million units of blood in the US alone [Goodnough LT, Shander A, Brecher ME. Transfusion medicine: looking to the future. Lancet 2003;361:161-9]. The current use of donated blood products is relatively safe; however, there are inherent problems with allogeneic blood transfusions. The wide spread use of blood in procedures results in problems involving inadequate supply exacerbated in times of war and disasters and by the limited storage life of blood donations (30-42 days). Blood contamination due to patient pre-disposition, poor collection, sterilization, or storage is the second most common cause of death from transfusion in the US [Hillyer CD, Josephson CD, Blajchman MA, Vostal JG, Epstein JS, Goodman JL. Bacterial contamination of blood components: risks, strategies, and regulation: joint ASH and AABB educational session in transfusion medicine. Hematology (Am Soc Hematol Educ Program) 2003:575-89]. Blood is a complex tissue involved in a plethora of homeostatic roles, including immunity, wound healing and the transport of nourishment, electrolytes, hormones, vitamins, heat, oxygen and the removal of metabolic waste products. However, by far the principle role of blood transfusions is the replacement of red cell volume and the maintenance of oxygen levels within the circulation. Creation of investigational new drugs (INDs) which would function as oxygen carriers and prolong shelf life is now a very active arena of scientific research. Several such IND products are now in clinical trials. This article gives an easy to follow concise evaluation of major areas of focus and current testing for each type of blood substitution molecule.

Bacterial Infections↗

White particulate matter found in blood collection bags consist of platelets and leukocytes.

BACKGROUND: In late January 2003, some blood centers and hospitals throughout the US voluntarily sus-pended the use of some RBC and plasma units for trans-fusion due to the presence of unknown white particulate matter (WPM) in these units. To better understand the WPM phenomena, a number of technologies were used to establish the nature of the particulates observed in Terumo Collection sets. STUDY DESIGN AND METHODS: All AS-5 nonleuko-reduced RBCs and plasma units were visually inspected for WPM by placing the bags on a flat counter, undisturbed, for approximately 10 minutes and then perform-ing a visual examination for particles. Particles were isolated and placed on microscope slides or in plastic tubes for further analysis. Electron microscopy, bright field microscopy, differential interference contrast microscopy, infrared spectroscopy, and flow cytometry procedures were performed to establish the nature of the particulate matter. In addition, leukoreduction filters and blood transfusion sets were used on RBCs units with WPM. RESULTS: The particles were mostly composed of PLTs and WBCs, and fragments of these cells. All macroscopic WPM was removed from RBCs with leukoeduction and transfusion filters. CONCLUSIONS: WPM originated from PLTs and WBCs. Foreign matter (e.g., plastic) was not observed in any of the units. Leukoreduction and transfusion filters can be used to remove macroscopic WPM.

Blood Platelets↗

Quality assessment of intraoperative blood salvage and autotransfusion.

Intraoperative blood salvage and autotransfusion are commonly used to minimize exposure to banked blood. Although this technique has been used widely for years, data vary regarding the quality of autotransfused blood. Salvaged blood may contain plasma, residual heparin, and free hemoglobin released from damaged cells. All of these factors may contribute to the adverse sequelae sometimes seen with autotransfusion. For these reasons, we have monitored autotransfused blood to assess its quality. Intraoperative blood salvage was used during most cardiac procedures and at the discretion of the surgeon in other specialties. Blood was collected through a double lumen catheter that was anticoagulated with heparin, filtered, centrifuged, and washed with saline. A sample of the blood was removed for analysis, which included hematocrit, heparin assay, fibrinogen, and free hemoglobin levels. Over a 6-year period, 1593 patients had intraoperative blood salvage with quality assessment. The majority of patients underwent cardiac operations (941 patients, 59%), whereas 243 had orthopedic (15%) and 208 had vascular (13%) procedures. Additionally, there were 127 pediatric patients (8%) and 74 miscellaneous procedures (5%). The highest average yield of salvaged blood was during vascular procedures (1073 +/- 76 mL), whereas orthopedic cases had the lowest yield (378 +/- 19 mL) and hematocrit (39%). There was minimal residual heparin activity, even in patients requiring systemic anticoagulation (0.3 to 0.5 units/mL). Patients undergoing pediatric procedures had the lowest concentration of free hemoglobin (476 mg/L), whereas all adult patients had higher free hemoglobin levels, especially vascular operations (990 mg/L). Intraoperative salvaged blood has minimal heparin activity, even in procedures requiring systemic anticoagulation. Fibrinogen, a marker of residual plasma, was undetectable in the majority of cases. These data indicate that intraoperative blood salvage generally results in a high-quality product (good hematocrit, low heparin, minimal plasma), although there are significant differences in free hemoglobin levels depending on the operative procedure.

Adult↗

A novel method of preoperative autologous blood donation with a large volume of plasma for surgery in gynecologic malignancies.

The objective of this study was to establish a novel method of preoperative autologous blood donation (PAD) for surgery of gynecologic malignancies, which requires considerable amounts of plasma relative to the red blood cell component. To collect a double volume of plasma over the amount obtained from whole blood without using an aphaeresis system, we first collected 500 ml of whole blood (2.5 units), and centrifuged it. We gave back the resultant red cell component alone, and retained the plasma component. We further collected an additional 500 ml of whole blood, and centrifuged it. The red cell component (2.5 units) was stored in the refrigerator (as a concentrated red cell, CRC). The resultant plasma together with the plasma collected first (5 units) was frozen and stored in the freezer (fresh frozen plasma, FFP), We repeated this procedure at most three times at intervals of 1 week. Erythropoietin was injected once a week and iron tablets were prescribed. Ninety-nine patients undergoing surgery for a gynecological malignancy were subjected to this method and 86 patients without PAD served as a control. We conducted the procedure for PAD without any noticeable side effects. The amount of actual use of allogeneic CRC and FFP were significantly reduced in the PAD group compared with the control group. In particular, 93.6% of the PAD cases who gave 10 or less units of FFP could go without allogeneic FFP. Postoperative serum albumin levels were higher in the PAD group compared with the control. We have established a novel PAD method which can yield a greater volume of FFP relative to CRC, thus meeting requirements for surgery for gynecological malignancies.

Blood Loss, Surgical↗

Evaluation of technical and behavioral issues in predonation alanine aminotransferase testing.

To evaluate the technical and behavioral impact of predonation alanine aminotransferase (ALT) testing, one group of 2914 donors (Reflotron group) were tested with the Boehringer Mannheim Reflotron instrument; 3042 control group donors had no predonation test. Mobile blood collection sites in three regional blood centers were studied. More Reflotron group donors than control group donors thought that predonation testing did not add time and was a good idea. Both groups were equally satisfied with the donation process and indicated they would donate again even if testing added time. Comparison of the Reflotron and standard laboratory tests showed excellent correlation with low variability. The mean r value was 0.934, with a mean sensitivity of 94.4 percent and a specificity of 99.8 percent. The staff working with the Reflotron group found predonation testing easy to incorporate into donor screening. They observed that donors were pleased with testing and accepting of deferral counseling for elevated ALT. The control group staff was concerned that predonation testing would require more time and would have a negative effect on the donor return rate. This did not appear to be the case as judged by donor response and the 6-month return rates of 50 percent for Reflotron group and 54 percent for control group donors.

Alanine Transaminase↗