Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Biological samples”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Gas chromatographic assay of glycerol mononitrates in biological samples.

A new gas chromatographic analysis of glycerol 1-nitrate and glycerol 2-nitrate is described. The method is suitable for a variety of biological samples and can detect down to the low nanogram range. An extract of the sample to be analysed is treated with phenylboronic acid. The glycerol mononitrates rapidly form cyclic boronates, with five- and six-membered rings, respectively, which can then be separated by gas chromatography and detected by an electron-capture detector.

Animals↗

Liquid chromatography with pre-column dansyl derivatisation and fluorimetric detection applied to the assay of morphine in biological samples.

A simple method employing pre-column dansylation and liquid chromatography is proposed for a very sensitive and specific assay of morphine in biological samples. Nalorphine is used as an internal standard. The detection limit is 0.2 picomol of injected morphine. In the assay of human sera spiked with 150 nmol/l, the intra- and inter-assay coefficients of variation were 3.7% (n = 10) and 4.5% (n = 10), respectively. No interferences were observed from more than 70 opiate and non-opiate drugs. Urine, plasma and total blood were assayed, using different extraction methods, with negligible interference from coextractives.

Chromatography, High Pressure Liquid↗

Analysis of bilirubin and bilirubin mono- and di-conjugates. Determination of their relative amounts in biological samples.

1. A novel method for determination of the relative amounts of unconjugated bilirubin and sugar mono- and di-conjugates of bilirubin in biological samples, including serum, is described and illustrated by its application to the analysis of bilinoids in rat bile. 2. The method is based on specific conversion of the carbohydrate conjugates of bilirubin into the corresponding mono- or di-methyl esters by base-catalysed transesterification in methanol. Under the selected reaction conditions, unconjugated biliru-in remains intact and no dipyrrole exchange in the bilinoids is detectable; transesterification of bilirubin mono- or di-glucuronide is virtually complete (approx. 99%), and sponification is negligible (less than 1%); recovery of the pigments is approx. 95%. 3. The reaction products bilirubin and its methyl esters are separated by t.l.c. and determined spectrophotometrically; the two isomeric bilirubin-IX alpha monomethyl esters are separated and therefore can be determined individually. 4. Reference bilirubin mono- and di-methyl esters have been synthesized and characterized, and the two isomers of bilirubin-IX alpha monomethyl ester and bilirubin dimethyl ester were obtained individually, in crystalline form. 5. With this new method, virtually all bilinoids (over 99%) in normal rat bile have been found to be conjugated, with diconjugates (71%) predominating. A significantly increased proportion of monoconjugates is present in bile collected from heterozygous Gunn rats or from normal rats that were refused with large amounts of bilirubin.

Alkalies↗

A method for separation of heparin species from biological samples by ethanol precipitation of compounds solubilized in guanidine hydrochloride.

In this paper we describe a procedure to determine glycosaminoglycan and oligosaccharide composition of biological samples such as cell cultures or tissue explants. We demonstrate that heparin species of different molecular mass can be easily fractionated by sequential ethanol precipitation in 4.0 M guanidine hydrochloride. We studied by gradient polyacrylamide gel electrophoresis fractionation of standard heparin and heparin-derived oligosaccharides by anion-exchange chromatography on DEAE-Sephacel resin eluted by increasing concentration of guanidine hydrochloride. The use of guanidine salts followed by sequential precipitation by increasing ethanol concentration allowed recovery of heparin and heparin-derived oligosaccharides.

Animals↗

Rapid analysis of parathion in biological samples using headspace solid-phase micro-extraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS).

A simple and rapid method for the analysis of parathion in biological samples is presented. The method consists of the extraction of parathion from blood samples by headspace solid-phase micro-extraction (SPME), followed by capillary gas chromatography and mass spectrometry detection. The recoveries in the blood samples after addition of ammonium sulphate and sulphuric acid were between 85% and 89% compared to samples prepared in water. Linearity was established over a concentration range of 0.1-5 microg/g blood with acceptable coefficients of correlation and limits of detection reached 0.02-0.05 microg/g. The time for an analysis is 57 minutes for one sample, including the extraction step. In conclusion, HS-SPME in combination with GC/MS is an effective method for the determination and quantification of parathion-ethyl and parathion-methyl in biological material.

Calibration↗

Determination of Pt in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) with electrothermal vaporization (ETV).

An electrothermal sample vaporization device was combined with an inductively coupled plasma spectrometer for the determination of Pt in biological samples (serum, urine, tissues). A commercial graphite furnace for atomic absorption was connected to an ICP torch using an electrically heated quartz tube. The argon gas stream was slightly modified. Sample aliquots up to 100 microL were dried at 120 degrees C, ashed at 1400 degrees C and subsequently heated to 2700 degrees C. The aerosol obtained was transported into a 2.2 kW argon ICP by means of a carrier gas flowing at 1.4 L/min. The detection limit was found to be 0.25-0.5 micrograms/L, depending upon the matrix. These values are one order of magnitude better than those obtained using conventional nebulizers. The precision (RSD) at 50 micrograms/L ranged from 0.04 to 0.07 and the accuracy (evaluated as recovery) was 103.2% to 105.3%. Because the matrix effects could not be neglected, different calibration curves were prepared for each kind of medium. The analytical capabilities of the method described were found to be suitable for the determination of Pt used in routine monitoring during chemotherapy with Cisplatin and other Pt-based compounds.

Hot Temperature↗

Quantitative analysis for organic acids in biological samples: batch isolation followed by gas chromatographic-mass spectrometric analysis.

This new method for qualitative and quantitative determination of organic acids, aldehydes, and ketones in biological samples is effective for use with urine, plasma, and amniotic fluid, and it requires no deproteinization. Isolation by batch-wise liquid partition chromatography on silicic acid follows formation of the O-(2,3,4,5,6-pentafluorobenzyl)oximes of oxoacids, aldehydes, and ketones. The total organic acid content of the sample provides a rapid screening test for metabolic abnormality. A wide-bore, bonded-phase capillary column was used for quantitative gas chromatographic-mass spectrometric analysis, followed by automated identification and quantification. Analytical recoveries were quantitative for a wide variety of metabolites. Gas-chromatographic retention indices, discriminating ions, and control ranges in amniotic fluid, plasma, and urine of adult subjects were determined for 61 biologically important compounds.

Adult↗

The use of Raman microscopy to determine and localize vitamin E in biological samples.

Alpha-tocopherol (aT), the predominant form of vitamin E in mammals, is thought to prevent oxidation of polyunsaturated fatty acids. In the lung, aT is perceived to be accumulated in alveolar type II cells and secreted together with surfactant into the epithelial lining fluid. Conventionally, determination of aT and related compounds requires extraction with organic solvents. This study describes a new method to determine and image the distribution of aT and related compounds within cells and tissue sections using the light-scattering technique of Raman microscopy to enable high spatial as well as spectral resolution. This study compared the nondestructive analysis by Raman microscopy of vitamin E, in particular aT, in biological samples with data obtained using conventional HPLC analysis. Raman spectra were acquired at spatial resolutions of 2-0.8 microm. Multivariate analysis techniques were used for analyses and construction of corresponding maps showing the distribution of aT, alpha-tocopherol quinone (aTQ), and other constituents (hemes, proteins, DNA, and surfactant lipids). A combination of images enabled identification of colocalized constituents (heme/aTQ and aT/surfactant lipids). Our data demonstrate the ability of Raman microscopy to discriminate between different tocopherols and oxidation products in biological specimens without sample destruction. By enabling the visualization of lipid-protein interactions, Raman microscopy offers a novel method of investigating biological characterization of lipid-soluble compounds, including those that may be embedded in biological membranes such as aT.

Antioxidants↗

[Patients' rights concerning their biological samples: different legal opinions].

In these pages, my wish is to highlight the legislative lagoon in our juridical frame related to the storage and use from the biological sample extracted from the patient (source subject) in an assistance process and the rights he has over it. This situation has led us to have different judgements everytime that a case like this has been judged.

Biological Specimen Banks↗

A rapid method for estimating nitrate in biological samples using gas chromatography with a flame-ionization detector or a thermal energy analyzer.

A simple, rapid method for estimating the nitrate content of biological samples was developed and tested. The method was based on the nitration of benzene under acidic conditions. The resulting nitrobenzene was analysed by gas chromatography with either a flame ionization detector (FID) or a Thermal Energy Analyzer (TEA) for detection. Recovery of nitrate added to urine, blood, saliva or faeces was 96, 97, 96 and 98%, respectively. Coefficients of variation for repeated analyses ranged from 2.2% for saliva to 12% for blood. Sensitivity was of the order of 0.5-1.5 mg/kg for the FID and 0.02-0.05 mg/kg for the TEA.

Chromatography, Gas↗

High sensitivity analysis of nitrite and nitrate in biological samples by capillary zone electrophoresis with transient isotachophoretic sample stacking.

Tissue level of nitrate and nitrite are established indicators of altered nitric oxide metabolism under various pathological conditions. Determination of these anions in biological samples, in the presence of high chloride concentration, using capillary zone electrophoresis suffers from poor detection sensitivity. Separation conditions providing excellent resolution and submicromolar detection sensitivity of nitrate and nitrite have been developed and validated. Simple sample preparation was applied that maintains nitrite stability in tissue extracts and at the same time allows transient isotachophoresis stacking of the analytes. Nitrate and nitrite concentrations in rat brain and liver tissue samples were determined in control and lipopolysaccharide treated animals.

Animals↗

Gas chromatographic-mass spectrometric determination of 4-nonylphenols and 4-tert-octylphenol in biological samples.

A simple and rapid method is described for the GC-MS determination of 4-nonylphenols (NOs) and 4-tert-octylphenol (OC) in biological samples. The NOs and OC in the sample are extracted with acetonitrile and the lipid in the sample extract is eliminated by partitioning between hexane and acetonitrile. After Florisil PR column clean-up, the sample extract is analyzed by GC-MS in the selected ion monitoring (SIM) mode. Average recoveries in pale chub (fish) and corbicula (shellfish) are 86.0 and 93.4% for NOs, and 95.8 and 96.4% for OC, respectively, spiked at the levels of 1.0 microg of NOs and 0.1 microg of OC per 5 g of fish and shellfish samples. The detection limits are 20 ng/g for NOs and 2 ng/g for OC.

Animals↗

Chromatographic procedures for determination of cannabinoids in biological samples, with special attention to blood and alternative matrices like hair, saliva, sweat and meconium.

This paper reviews chromatographic procedures for determination of cannabinoids in biological samples. Special attention was focused on blood and alternative matrices like hair, saliva, sweat and meconium. Papers published from 1998 to the early beginning of 1999 were taken into consideration. Gas chromatographic and liquid chromatographic procedures with different detectors (e.g. mass spectrometer or diode array) were considered. Basic information about the biosample assayed. sample preparation, work-up, gas chromatography column or liquid chromatography column and mobile phase, detection mode, reference and validation data are summarized in tables.

Body Fluids↗

Isoelectric point-based prefractionation of proteins from crude biological samples prior to two-dimensional gel electrophoresis.

Two-dimensional gel electrophoresis (2-DE) is used to compare the protein profiles of different crude biological samples. Narrow pH range Immobilized pH Gradient (IPG) strips were designed to increase the resolution of these separations. To take full advantage of IPG strips, the ideal sample should be composed primarily of proteins that have isoelectric point (pI) values within the pH range of the IPG strip. Prefractionation of cell lysates from a human prostate cancer cell line cultured in the presence or absence of epigallocatechin-3-gallate was achieved in fewer than 30 min using an anion-exchange resin and two expressly designed buffers. The procedure was carried out in a centrifuge tube and standard instrumentation was used. The cell lysates were prefractionated into two fractions: proteins with pI values above 7 and between 4 and 7, respectively. The fractions were then analyzed by 2-DE, selecting appropriate pH ranges for the IPG strips, and the gels were compared with those of unprefractionated cell lysates. Protein loading capacity was optimized and resolution and visualization of the less abundant and differentially expressed proteins were greatly improved.

Cell Line, Tumor↗

Quantification of endogenous retinoic acid in limited biological samples by LC/MS/MS.

We report a sensitive LC (liquid chromatography)/MS/MS assay using selected reaction monitoring to quantify RA (retinoic acid), which is applicable to biological samples of limited size (10-20 mg of tissue wet weight), requires no sample derivatization, provides mass identification and resolves atRA (all-trans-RA) from its geometric isomers. The assay quantifies over a linear range of 20 fmol to 10 pmol, and has a 10 fmol limit of detection at a signal/noise ratio of 3. Coefficients of variation are: instrumental, 0.5-2.9%; intra-assay, 5.4+/-0.4%; inter-assay 8.9+/-1.0%. An internal standard (all-trans-4,4-dimethyl-RA) improves accuracy by confirming extraction efficiency and revealing handling-induced isomerization. Tissues of 2-4-month-old C57BL/6 male mice had atRA concentrations of 7-9.6 pmol/g and serum atRA of 1.9+/-0.6 pmol/ml (+/-S.E.M.). Tissue 13-cis-RA ranged from 2.9 to 4.2 pmol/g, and serum 13-cis-RA was 1.2+/-0.3 pmol/ml. CRBP (cellular retinol-binding protein)-null mouse liver had atRA approximately 30% lower than wild-type (P<0.05), but kidney, testis, brain and serum atRA were similar to wild-type. atRA in brain areas of 12-month-old female C57BL/6 mice were (+/-S.E.M.): whole brain, 5.4+/-0.4 pmol/g; cerebellum, 10.7+/-0.3 pmol/g; cortex, 2.6+/-0.4 pmol/g; hippocampus, 8.4+/-1.2 pmol/g; striatum, 15.3+/-4.7 pmol/g. These data provide the first analytically robust quantification of atRA in animal brain and in CRBP-null mice. Direct measurements of endogenous RA should have a substantial impact on investigating target tissues of RA, mechanisms of RA action, and the relationship between RA and chronic disease.

Alitretinoin↗

The redox-cycling assay is not suited for the detection of pyrroloquinoline quinone in biological samples.

Based on the results of the so-called redox-cycling assay it has been claimed that various common foods and beverages as well as mammalian body fluids and tissues contain substantial quantities (microM) of free PQQ [M. Paz et al. (1989) in: PQQ and Quinoproteins (J.A. Jongejan and J.A. Duine, eds.) Kluwer Academic Publishers, Dordrecht, pp. 131-143 and J. Killgore et al. (1989) Science 245, 850-852]. However, by investigating samples from such sources with a biological assay of nM sensitivity, we could not confirm these claims. Analysis of the samples with procedures that proved adequate for the detection of PQQ adducts and conjugates gave equally negative results. To account for the positive response in the redox-cycling assay, as opposed to the negative results obtained by other methods, a search was made for those substances in these samples that caused the false-positive reactions. It was found that a number of commonly occurring biochemicals like ascorbic and dehydroascorbic acid, riboflavin and to a lesser extent pyridoxal phosphate, gave a positive response in the redox-cycling assay. The amounts of these interfering substances that were determined in the samples by independent methods could well explain the response. In separate experiments it was found that the effect of PQQ added to biological samples was obscured over an appreciable range of concentrations. For these reasons it must be concluded that the redox-cycling assay is not suited for the detection of PQQ in these samples. Any claims that are based on the results of this method should be disregarded.

Animals↗

A simplified multidimensional approach for analysis of complex biological samples: on-line LC-CE-MS.

Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.

Animals↗

XAS of dilute biological samples.

The experimental setup of beamline ID26 at ESRF (Grenoble) has been successfully exploited to obtain high-quality XAS (X-ray absorption spectroscopy) data from a biological sample where the metal concentration is about 100 micro M. The sample consists of the adenosine monophosphate deaminase (AMPD) histidine proline rich glycoprotein (HPRG) complex that contains 3-4 Zn(II) ions per dimer of approximately 320 kDa molecular weight. The experiment shows that third-generation X-ray sources equipped with insertion devices and appropriate optics and detectors allow the investigation of complex biological systems where the metal concentration is intrinsically low. The availability of such experimental setups makes possible a completely new set of experiments in biological XAS.

AMP Deaminase↗