Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “cytocompatibility”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

302 records · Page 17Linked to original sources

[Study on the recovery of 4 types of cultured cell after contacting varieties of dental casting alloys].

Four types of cultured cell (Gin-1, Chang Liver, HEP-2 and L-929) were used in vitro to determine the cytotoxicity of 12 Chinese-Japanese Dental Casting Alloys from cell recovery ability. A new cytocompatibility detecting method--cell recovery test was established and recommended. This method can be able to observe the state of cell recovery through self growth cycle, diminish the side-effect of dead cell and its products on the living cells, nearly mimic the environment in vivo and study the inherited toxicology of cells. The application of computer photo-pattern analysis technique can acquire the objective and accurate data directly.

Animals↗

[The coherence between 3 evaluation methods of biocompatibility].

Three successive series of tests (the primary including cytocompatibility tests and the secondary in vivo and usage tests) can be used to evaluate the biocompatibility of dental materials. The products are only submitted to secondary tests in case of satisfactory results obtained with primary tests. A coherence between the results of primary and secondary tests is necessary before performing in vivo tests. The aim of this paper is to study the coherence between two primary tests and a secondary test. The biocompatibility of Sealite and a pulp canal sealer was studied 4 and 12 weeks after mixing, according to two primary models (cell culture on agarose and a toxicity study of the extraction products) and a secondary model (intrabony implantation in the rabbit). The two primary tests gave different results for Sealite and the pulp canal sealer. Only the agarose cell culture and the intrabony implantation in the rabbit have given similar statistical results. The biological evaluation of biomaterials should begin with a study of the mechanism of action of the cytotoxic products using several in vitro tests. These latter are unable to predict the behaviour of a biomaterial in an in vivo test.

Animals↗

[Study on cyto-compatibility of PGLA film for periodontal guided tissue regeneration].

This study was aimed to evaluate the cyto-compatibility of PGLA film for periodontal guided tissue regeneration (GTR) and their degradable products. Different extraction temperature, time and ratio were used to assess the cell relative growth rate (RGR) for PGLA. The degradable solution were brought into contact with cultured cells in vitro to observe the effects of cytotoxicity at 2, 4, 6, 8 and 10 weeks. The results showed when the extraction ratio was 0.1 g/ml, the extraction time has no effects on cytotoxicity at 37 degrees C. When the ratio was 0.1 cm2/ml, slight cytotoxic reaction appeared with the increase of extraction temperature (50 degrees C or 70 degrees C). When the extraction ratio was 0.5 cm2/ml in contract with the degradable solution at 37 degrees C for 72 h, the cell growth rate decreased. When the ratio was 6 cm2/ml, the cytotoxicity existed in some degree even if the temperature was at 37 degrees C for 24 h. After 2-4 w, the degradable solution had no obvious toxic effects on cells. However, the RGR gradually decreased as the degradation period increased. In conclusion, the effects of the extraction temperature, time, ratio and the degradation products accumulating in solution on RGR may exist. PGLA film has a good cytocompatibility.

Animals↗

Design of oligolactone-based scaffolds for bone tissue engineering.

Novel difunctional oligolactone macromers have been synthesized by ring-opening oligomerization of various lactones (L-lactide, glycolide, p-dioxanone) in the presence of suitable diols (propane-1,2-diol, dianhydro-D-glucitol) and subsequent endcapping of the formed oligolactones with methacrylate moieties. Based on these macromers, two fabrication procedures were developed to fabricate highly porous scaffolds and the material properties including in vitro biodegradation behaviour of the resulting polymeric scaffolds were investigated. Preliminary in vitro studies on the cytocompatibility of the fabricated scaffolds and on osteoblast cultivation on the optimized polymeric materials demonstrated that the oligolactide based polymer networks possess an excellent biocompatibility and that they are promising candidates as scaffolds in bone tissue engineering.

3T3 Cells↗

[Preliminary research on preparation of porcine bladder acellular matrix graft for tissue engineering applications].

OBJECTIVE: To investigate the preparation method of porcine bladder acellular matrix graft (BAMG) and evaluate the feasibility of using BAMG as biomaterial scaffold to construct tissue engineering bladder. METHODS: Bladders were harvested from adult pigs at a slaughterhouse and were decellularized by the method of enzyme digestion or eradicator washing. The BAMG was then examined by optic microscope and electron microscope to confirm no cell elements remained. The structure of the BAMG was always observed through the Scanning Microscope. The skeletal muscle stem cells of New Zealand white rabbits were implanted in 96-hole-plank and cultured by BAMG extract liquid or normal culture medium. The cytotoxicity of BAMG was tested through MTT assay. New Zealand white rabbits were underwent bladder triangle area spared cystectomy and reconstructed by the heterogeneity BAMG. The animal bladders were obtained after six weeks and the tissue regeneration was examined. RESULTS: Good outcome were obtained with either of the two methods. There were no cell elements remained under the examination of optical microscope and electron microscope. The interstice could observed on BAMG through the Scanning Microscope. The relative growth rate (RGR) was 81%, 88%, 93% and 96% separately on the 2nd, the 4th, the 6th and the 8th day (t = 3.7419, P < 0.025). The cytotoxicity score was I, which indicated that BAMG had a good cytocompatibility. All rabbits were alive except one which died from diarrhea. The reconstructed bladder resumed the construction and function of the bladder. The transitional cells and muscle cells growth could be seen in the scaffold of the repaired bladder after six weeks. CONCLUSION: The porcine BAMG has good biocompatibility and can be used as ideal biomaterial scaffold of bladder tissue engineering.

Animals↗

Enhancement of the mechanical and biological properties of a biomembrane for tissue engineering the ocular surface.

INTRODUCTION: In this study, we have developed and optimised a novel gelatin-chitosan (GC) substrate for use as a cellular carrier for tissue-engineered conjunctival epithelium. MATERIALS AND METHODS: The substrate was fabricated by casting and the mechanical properties of the substrate, including tensile strength and elongation, were measured. Using the MTT, cell proliferation assay with rabbit conjunctival fibroblasts, we optimised the G:C ratio to enhance cytocompatibility. Rabbit conjunctival epithelial cells were immunostained using monoclonal antibodies for keratin 4 and pancytokeratin to investigate the biological effects of the GC substrate on the proliferation and differentiation of epithelial cells. RESULTS: We found that increasing the amount of gelatin resulted in an increase in elasticity (from 1:9 to 1:1 ratio), reaching a maximum (101.89% +/- 7.13%) at a ratio of 1:1. The MTT assay showed that the proliferation of conjunctival fibroblasts significantly increased from 0.068 +/- 0.017 to 0.177 +/- 0.011 (P = 0.014) as the gelatin was increased from 20% (1:4) to 50% (1:1). Additional studies using tissue-cultured conjunctiva explants showed that these explants grew well on the substrate, forming a multilayered epithelium. Cell morphology on this substrate was similar to that of cells grown on culture dishes alone. Positive staining of keratin 4 and pancytokeratin indicated that the substrate supported normal differentiation of conjunctival epithelial cells. CONCLUSION: By enhancing the proportion of gelatin, both the mechanical and biological properties of the chitosan substrate were improved. The results also suggest that this GC biomembrane may be a useful candidate for reconstructive tissue engineering of the conjunctiva.

Animals↗

[A comparative study of the in vitro biocompatibility of 2 root canal sealing cements].

The aim of this study was to evaluate the biocompatibility of radicular sealing cements with agarose cell culture. The two cements studied were Sealite and Pulp Canal Sealer with different mixing times. In the experimental conditions used the cytocompatibility of Sealite was better than that of Pulp Canal Sealer. The cytotoxicity of both products was not negligible and corresponded to those of other studies with Pulp Canal Sealer and a cement with amount similar composition to Sealite. Because theses cements are currently used with success in humans, the results of this test raise the question of extrapolation to man.

Animals↗

[Influence of suture materials on cell viability: a comparative experimental study].

Among the conditions that a material must satisfy to be considered biocompatible, most important is the non negative influence on the cellular viability of the surrounding tissue (cytocompatibility). The aim of our work was to evaluate in vitro, whether different types of materials (usually used in surgery), alter the viability parameters or the morphological characteristics of the cultured cells in contact with them.

Animals↗

Membranes as substrates for hepatocyte adhesion in liver support bioreactors.

Fourteen membranes out of cellulose (CuprophanR), polyamide and polypropylene were compared in a cytocompatibility test using the cytokinetics and cytomorphology of primary hepatatocytes as parameters. Additionally, the impact of coating the membranes with collagen or fibronectin was investigated. Hepatocytes were not able to attach in acceptable amounts on investigated cellulose membranes. On polyamide and polypropylene membranes a sufficient cell seeding was possible. Coating with collagen or fibronectin improves the attachment and spreading on all membranes. Differences between collagen and fibronectin were detected, observing the morphology of the cells: on collagen, most of the cells spread, whilst on fibronectin, most of the cells spread and flattened polygonally. If the adhesion of hepatocytes prolongs their metabolic function, a large adhesion surface in bioreactors is necessary. To reach a high surface area for cell adhesion in bioreactors one possibility is the use of polyamide and polypropylene membranes.

Animals↗

Chemically processed bovine heterografts of the second generation as arterial substitutes: a comparative evaluation of three commercial prostheses.

The use of chemically processed bovine heterografts is primarily confined to the construction of arterio-venous blood accesses in those patients requiring hemodialysis, plasmapheresis or chemotherapy. The grafts of the first generation i.e. Artegraft and Solcograft are now being supplanted by those of the second generation i.e. Reinforced Artegraft, Solco P and NCGT. We have investigated these three types of arterial prostheses as a biomaterial in terms of sterility, inflammatory response and cytocompatibility and as a blood conduit in dogs in terms of patency and healing. For each type of graft, two implantations were carried out for durations of 4 hours, 24 hours, 48 hours, one week, two weeks, one month, three months, and six months. Therefore a total of 48 grafts were implanted. All grafts but five were patent at sacrifice: thromboses were observed in two Reinforced Artegraft (after two weeks and after one month) and in three NCGT (after 24 hours, after 48 hours, and after one month). Therefore the following patencies were observed: Reinforced Artegraft 14/16, Solco P 16/16 and NCGT 13/16. In all the patent grafts, the healing was reduced to the formation of a pannus along both anastomoses; thrombotic accumulations were observed on the surface defects of the grafts, particularly the NCGT graft. The Reinforced Artegraft presents only minor advantages over the previous Artegraft; the Solco P, somewhat more acceptable is no longer commercially available since the manufacturer withdrew it after early clinical failures. The improvements noted in the bovine heterografts of the second generation appear to be marginal as compared to those of the first generation.

Anastomosis, Surgical↗

Cell cultures in the biocompatibility study of synthetic materials.

In vitro cytotoxicity (Neutral Red uptake, Kenacid Blue and MTT) and cytocompatibility (cell adhesion and proliferation) tests were applied to the biocompatibility study of a series of poly(ester-ether-ester) block copolymers of potential interest as biomaterials. Our results indicate that the copolymer extracts after 72 hours incubation with a 3T3 mouse fibroblast cell line do not induce significant toxic effects. Furthermore, human umbilical vein endothelial cells seeded on thin copolymer films show a normal pattern of growth. We conclude that the in vitro tests used are a valid instrument to evaluate the potential toxic action of synthetic materials on different cell compartments and that the tested materials seem to be promising for future applications in the field of biomedical devices.

3T3 Cells↗

Chemical sorbents: official guidelines and experimental approach.

To evaluate the biocompatibility of an anionic exchange resin with active group trimethylammonium and charged with chloride ions an experimental study was performed with different tests to determine cytocompatibility, acute systemic toxicity, intracutaneous reactivity, allergic sensibilization, haemocompatibility and release of acetone, dichloromethane, quaternary amines and heavy metals (Pb, Cu, Cd) in eluate. Thus an anionic exchange resin can link all anionic substances; an ex vivo study on the participation of the dissociated sodic heparin in the anionic exchange was also conducted. In fact every time an extracorporeal circuit is made an anticoagulant must be administered to the patient and the removal of the drug could cause serious haemocoagulative problems. The results of the study showed a high biocompatibility of the resin that did not cause different significant reactions in comparison with negative control substances. The coating of the resin with poly-hydroxy-ethyl methacrilate with a separation phase technique avoided heparin removal from blood. Therefore adjustment of the dosage may not be necessary during further in vivo experiments. Future researches aiming to evaluate the the effectiveness and the biocompatibility of the sorbent in a living being will be performed in the next steps of the study.

Animals↗

Comparison of hollow fibre membranes for hepatocyte immobilisation in bioreactors.

Various hollow fibre membranes of polyamide, cellulose and polypropylene were investigated as potential substrata for hepatocyte immobilisation in bioreactors for hybrid liver support systems. Membranes were subjected to a cytocompatibility test in which the attachment and morphology of primary hepatocytes were evaluated. The effect of coating with collagen and fibronectin was also studied. Adequate cell immobilisation was possible on polypropylene and polyamide membranes even without coating. The flattening process of the cells was dependent on the material and the coating. The incorporation of porous polypropylene hollow fibres in hybrid liver cell bioreactors and their specific permeability properties could also offer means for cell oxygenation, metabolite distribution and immuno-isolation purposes.

Animals↗

[The biocompatibility of catheters and stents used in urology].

Biocompatibility can be interpreted as the optimal combination of a series of interactions occurring at the material-tissue interface as soon as these two systems are in contact. It is a multifactorial interface property which integrates all of the phenomena involved in a biological environment i.e. absence of toxicity of the material for the body and absence of degradation of the material by the body. Biocompatibility can be evaluated in a normative context by using in vivo techniques in animals or in vitro techniques using cell cultures allowing the study of cytotoxicity (related to a concept of safety) and cytocompatibility (related to biological acceptability) of a material. Because of their intimate contact with the urothelium throughout implantation, the biocompatibility of catheters and stents constitutes a major requirement. This review presents the current data reported in the literature concerning the evaluation of the biocompatibility of materials used in urology. The main problems encountered are alterations of the urothelium, such as erosions or, on the contrary, mucosal hyperplasia, and the existence of incrustations developing on these materials.

Animals↗