Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VIBRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Changes over a workshift in aesthesiometric and vibrotactile perception thresholds of workers exposed to intermittent hand transmitted vibration from impact wrenches.

OBJECTIVES: To investigate the changes over a workshift in fingertip tactile perception thresholds in users of impact wrenches exposed to intermittent hand transmitted vibration. A further aim was to assess the relation between acute changes in tactile sensation, sensorineural disorders, and vibration dose. METHODS: The study populations consisted of 30 workers exposed to vibration (16 men and 14 women) and 25 control manual workers (10 men and 15 women). Sensorineural disorders in the fingers and hands were graded according to the staging system of the Stockholm workshop scale. Tactile function was tested by measuring aesthesiometric thresholds (two point discrimination and depth sense perception) and vibrotactile perception thresholds at 16, 31.5, and 125 Hz before and after a workshift. Temporary threshold shift was then calculated as the difference between threshold measures before and after the shift. The measurement and assessment of exposure to vibration were made according to the international standard ISO 5349. The vibration dose accumulated over a workshift (m2s-4h) was estimated for each user of impact wrenches. Daily exposure to vibration was also expressed in terms of eight hour energy equivalent frequency weighted acceleration ((ahw)eq(8) in ms-2 rms). RESULTS: After adjustment for age and alcohol consumption, vibrotactile perception thresholds before exposure were greater in the workers exposed to vibration than in the controls. No differences in aesthesiometric thresholds before the shift were found between the study groups. Sensorineural disorders were mild in the workers exposed to vibration and minor neurological abnormalities were detected at the physical examination. Owing to the intermittent use of impact wrenches, the estimated mean (ahw)eq(8) for the subjects exposed to vibration was low (1.3 ms-2 rms). A significant temporary threshold shift in vibration perception at all test frequencies was found in the workers exposed to vibration but not in the controls. A significant increase in depth sense perception thresholds was found in the men exposed to vibration. The temporary threshold shift in vibration perception at 125 Hz, and to a lesser extent at 16 and 31.5 Hz, was associated with the severity of sensorineural disorders. In the workers exposed to vibration the temporary threshold shift in vibration sense at all test frequencies was positively related to the estimated dose of vibration received over a workshift. No significant relation was found between aesthesiometric threshold changes and vibration dose. CONCLUSIONS: Intermittent exposure to hand transmitted vibration over a workshift can cause a deterioration of tactile perception in the fingers of users of impact wrenches. Acute tactile dysfunction was related to both the estimated dose of vibration and the severity of sensorineural symptoms. The temporary threshold shift in vibration perception suggested that fast adapting skin mechanoreceptors such as Pacinian and Meissner corpuscles were mainly involved in the acute sensory impairment to the fingertips of the workers exposed to vibration. Changes in tactile perception can occur in workers with daily exposure to vibration that is considered to be associated with a minimal risk of adverse health effects induced by vibration.

Adult↗

Acute vascular responses to the frequency of vibration transmitted to the hand.

OBJECTIVES: To investigate the acute effects of the frequency of hand transmitted vibration on finger circulation. A further aim was to investigate whether the frequency weighting assumed in current standards for hand transmitted vibration reflects the haemodynamic changes which occur in the fingers exposed to vibration with different frequencies but with the same frequency weighted acceleration magnitude. METHODS: Finger skin temperature (FST) and finger blood flow (FBF) were measured in the middle fingers of both hands of 10 healthy men. With a static load of 10 N, the right hand was exposed for 15 minutes to the following root mean square (rms) acceleration magnitudes and frequencies of vertical vibration: 5.5 m/s(2) at 16 Hz; 11 m/s(2) at 31.5 Hz; 22 m/s(2) at 63 Hz; 44 m/s(2) at 125 Hz; and 88 m/s(2) at 250 Hz. These exposures to vibration produce the same frequency weighted acceleration magnitude (5.5 m/s(2) rms) according to the frequency weighting included in the international standard ISO 5349. A control condition consisted of exposure to the static load only. Finger circulation was measured before application of the vibration and static load and at fixed intervals during exposure to vibration and a 45 minute recovery period. RESULTS: No significant changes in finger circulation were found with only the static load. The FST did not change significantly during or after acute exposure to vibration. In the vibrated right finger, exposures to vibration with frequencies of 31. 5-250 Hz provoked a greater reduction in FBF than did vibration of 16 Hz or the static load only. In the non-vibrated left finger, the FBF measured with vibration at each frequency of 63-250 Hz was significantly lower than that measured with static load only. The reduction in FBF during exposure to vibration with any frequency was stronger in the vibrated finger than in the non-vibrated finger. In both fingers, there was a progressive decrease in FBF after the end of exposure to vibration with frequencies of 31.5-250 Hz. The higher the frequency of vibration, the stronger the decrease in FBF in both fingers during recovery. CONCLUSIONS: Acute exposures to vibration with equal frequency weighted magnitude reduce the FBF in both vibrated and non-vibrated fingers for frequencies between 31.5 and 250 Hz. The extent of digital vasoconstriction after exposure to vibration increases with increasing frequency. The frequency weighting given in current standards tends to overestimate the vasoconstriction associated with acute exposures to vibration frequencies around 16 Hz.

Adult↗

Acute effects of continuous and intermittent vibration on finger circulation.

OBJECTIVES: To compare the acute response of finger circulation to continuous and intermittent vibration having the same total duration of vibration exposure and the same energy-equivalent acceleration magnitude. METHODS: Finger blood flow (FBF) was measured in the middle and little fingers of both hands of ten healthy men. Finger skin temperature (FST) was measured in the middle right finger. With a static load of 10 N, the middle finger of the right hand was exposed to 125 Hz at 44 m s(-2) root mean square (r.m.s.) in five conditions: (1). 30 min continuous exposure, (2). two periods of 15 min, separated by a 15 min period with no vibration, (3). four periods of 7.5 min, separated by 7.5 min periods with no vibration, (4). eight periods of 3.75 min, separated by 3.75 min periods with no vibration, (5). 16 periods of 1.88 min, separated by 1.88 min periods with no vibration. All five exposures correspond to an 8 h energy-equivalent frequency-weighted acceleration magnitude of 1.4 m s(-2) r.m.s. according to International Standard ISO 5349-1 (2001). Finger circulation was measured in all four digits before the application of vibration and at fixed intervals during vibration exposure and during a 45 min recovery period. RESULTS: The FST did not change during vibration exposure, whereas all vibration conditions produced significant reductions in FBF of the vibrated finger when compared with the pre-exposure FBF. During vibration exposure, the vibration caused a similar degree of vasoconstriction in the vibrated finger without evidence of cumulative effects during intermittent exposure. After the end of exposure to 30 min of continuous vibration there was a progressive decrease in the FBF, whereas there was no statistically significant reduction following exposure to intermittent vibration. CONCLUSIONS: For the vibration stimuli investigated (exposure durations varying from 1.88 min to 30 min, with rest periods varying from 1.88 min to 15 min), the reduction of FBF during exposure was the same for continuous and intermittent vibration. The after effect of vibration was greater following the continuous vibration exposure. Although some evidence from this study is consistent with the notion that intermittent vibration has a less severe effect than continuous vibration, this evidence is not yet conclusive.

Adult↗

Acute effects of force and vibration on finger blood flow.

OBJECTIVES: To investigate the effects of contact force at the finger on acute changes in finger circulation during exposure to vibration. METHODS: Each of 10 subjects attended 11 sessions in which they experienced five successive experimental 5-minute periods: (i) no force and no vibration; (ii) force and no vibration; (iii) force and vibration; (iv) force and no vibration; (v) no force and no vibration. During periods (ii) to (iv), the intermediate phalanx of the right middle finger applied one of two forces (2 N or 5 N) on a platform that vibrated during period (iii) at one of two frequencies: 31.5 Hz (at 4 or 16 ms(-2) r.m.s.) or 125 Hz (at 16 or 64 ms(-2) r.m.s.). Finger blood flow was measured in the exposed right middle finger, the unexposed right little finger, and the unexposed left middle fingers throughout the 25 minutes of each session. RESULTS: The application of force alone caused a reduction in finger blood flow in the exposed finger, but not other fingers. There were additional reductions in finger blood flow caused by vibration, with greater reductions at the higher vibration magnitudes at both frequencies but no difference between the two frequencies when using unweighted acceleration. The vibration caused a similar vasoconstriction in vibrated and non-vibrated fingers. CONCLUSIONS: Modest levels of force applied by a finger can have a large effect on the finger blood flow, possibly due to the constriction of local blood vessels. The acute vascular effects of vibration cause additional reductions in finger blood flow that are not limited to the finger experiencing force and vibration. In all fingers (exposed and not exposed to vibration), the greater the magnitude of vibration, the greater the reduction in finger blood flow. In all fingers (exposed and not exposed to vibration), when the vibration was frequency weighted according to current standards, 125 Hz vibration caused greater reductions in finger blood flow than 31.5 Hz vibration.

Adult↗

Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration.

OBJECTIVES: To investigate changes in digital circulation during and after exposure to hand transmitted vibration. By studying two frequencies and two magnitudes of vibration, to investigate the extent to which haemodynamic changes depend on the vibration frequency, the vibration acceleration, and the vibration velocity. METHODS: Finger skin temperature (FST), finger blood flow (FBF), and finger systolic pressure were measured in the fingers of both hands in eight healthy men. Indices of digital vasomotor tone-such as critical closing pressure and vascular resistance-were estimated by pressure-flow curves obtained with different hand heights. With a static load of 10 N, the right hand was exposed for 30 minutes to each of the following root mean squared (rms) acceleration magnitudes and frequencies of vertical vibration: 22 m.s-2 at 31.5 Hz, 22 m.s-2 at 125 Hz, and 87 m.s-2 at 125 Hz. A control condition consisted of exposure to the static load only. The measures of digital circulation and vasomotor tone were taken before exposure to the vibration and the static load, and at 0, 20, 40, and 60 minutes after the end of each exposure. RESULTS: Exposure to static load caused no significant changes in FST, FBF, or indices of vasomotor tone in either the vibrated right middle finger or the non-vibrated left middle finger. In both fingers, exposure to vibration of 125 Hz and 22 m.s-2 produced a greater reduction in FBF and a greater increase in vasomotor tone than did vibration of 31.5 Hz and 22 m.s-2. In the vibrated right finger, exposure to vibration of 125 Hz and 87 m.s-2 provoked an immediate vasodilation which was followed by vasoconstriction during recovery. The non-vibrated left finger showed a significant increase in vasomotor tone throughout the 60 minute period after the end of vibration exposure. CONCLUSIONS: The digital circulatory response to acute vibration depends upon the magnitude and frequency of the vibration stimulus. Vasomotor mechanisms, mediated both centrally and locally, are involved in the reaction of digital vessels to acute vibration. The pattern of the haemodynamic changes in the fingers exposed to the vibration frequencies used in this study do not seem to support the frequency weighting assumed in the current international standard ISO 5349.

Adult↗

Sound and vibration sensitivity of VIIIth nerve fibers in the grassfrog, Rana temporaria.

We have studied the sound and vibration sensitivity of 164 amphibian papilla fibers in the VIIIth nerve of the grassfrog, Rana temporaria. The VIIIth nerve was exposed using a dorsal approach. The frogs were placed in a natural sitting posture and stimulated by free-field sound. Furthermore, the animals were stimulated with dorso-ventral vibrations, and the sound-induced vertical vibrations in the setup could be canceled by emitting vibrations in antiphase from the vibration exciter. All low-frequency fibers responded to both sound and vibration with sound thresholds from 23 dB SPL and vibration thresholds from 0.02 cm/s2. The sound and vibration sensitivity was compared for each fiber using the offset between the rate-level curves for sound and vibration stimulation as a measure of relative vibration sensitivity. When measured in this way relative vibration sensitivity decreases with frequency from 42 dB at 100 Hz to 25 dB at 400 Hz. Since sound thresholds decrease from 72 dB SPL at 100 Hz to 50 dB SPL at 400 Hz the decrease in relative vibration sensitivity reflects an increase in sound sensitivity with frequency, probably due to enhanced tympanic sensitivity at higher frequencies. In contrast, absolute vibration sensitivity is constant in most of the frequency range studied. Only small effects result from the cancellation of sound-induced vibrations. The reason for this probably is that the maximal induced vibrations in the present setup are 6-10 dB below the fibers' vibration threshold at the threshold for sound. However, these results are only valid for the present physical configuration of the setup and the high vibration-sensitivities of the fibers warrant caution whenever the auditory fibers are stimulated with free-field sound. Thus, the experiments suggest that the low-frequency sound sensitivity is not caused by sound-induced vertical vibrations. Instead, the low-frequency sound sensitivity is either tympanic or mediated through bone conduction or sound-induced pulsations of the lungs.

Acoustic Stimulation↗

The postural disorientation induced by neck muscle vibration subsides on lightly touching a stationary surface or aiming at it.

The aim of this study was to investigate whether the standing body spatial disorientation, induced by neck muscle vibration, and the related post-effects can be suppressed by light finger touch (LFT) of a stationary surface. Continuous (60 s) vibration of dorsal neck or sternocleidomastoid muscle was administered with eyes closed. The center of foot pressure (CFP) displacement, measured by a stabilometric platform, indicated the degree of vibration-induced body tilt. We also investigated whether sensory information from LFT itself was necessary or anticipation of a more secure posture was enough for reducing vibration effects. To this aim, we administered a vibration pulse (5 s) to dorsal neck or sternocleidomastoid muscle and during reaching to the stationary surface. CFP was recorded during both vibration and post-vibration condition and during the aiming task. Neck vibration induced significant CFP displacement in the direction opposite to vibration site. Post-vibration, CFP slowly returned to control values with ample oscillations. LFT during vibration reduced body tilt. LFT was more effective when fingertip contact was in the plane of the greatest tilt. LFT applied during either vibration or post-vibration period reduced post-vibration effects. Reaching toward the stationary surface was enough for reducing vibration-induced body tilt to values close to those observed during actual LFT. The novel conclusions of this study are: 1) LFT is able to relieve the effects of vibration-induced abnormal proprioceptive input from the neck, a segment central to postural control and orientation; 2) LFT during vibration also attenuates vibration post-effects, further suggesting that its action is not merely mechanical; 3) the intention to stabilize the body generates a new postural 'set' sufficient for diminishing body tilt.

Adult↗

[The effect of whole-body vibration: an unrecognized medical problem].

Exposure to whole-body vibration is a growing concern in industry, traffic and in other branches of the economy. This harmful physical factor endangers work efficiency and human health not only at work but also in everyday life, in public transportation and even at home. In spite of increasing exposure to vibrations, our medical practice does not pay adequate attention to the health effects of whole-body vibration. The paper deals with the basic characteristics of vibration (frequency, amplitude, velocity and acceleration), its adequate evaluation (effective or weighted average value, peak values, rating and weighting procedure of vibration measurement) and exposure (vibration direction, exposure time, transmission and dissipation). In industry and traffic, vibrations present complex oscillatory motions, characterized by a wide frequency spectrum, variable amplitude and acceleration, and different directions. To assess the harmful effects of vibration, the International Organization for Standardization (ISO) has proposed three standards for acceptable human exposure to whole-body vibration: fatigue-decreased proficiency boundary, exposure limit and reduced comfort boundary. Quantitative parameters of vibration for some vehicles, and for constructional, industrial and agricultural machinery are also given. The most pronounced long-term effect of whole-body vibration is damage to the spine. The spinal region most frequently affected is the lumbar part, where spinal deformation, lumbago and sciatica can develop. The possible cause of spinal damage could be mechanical overload and metabolic changes of the intervertebral disc. Other organ systems, such as peripheral and autonomic nervous, vestibular, vascular, digestive and female reproductive systems are also liable to become affected. Risk assessment of chronic health effects is based on the appropriate evaluation of whole-body vibration exposure and individual response. Health risk increases with the intensity and duration of vibration exposure. The concomitant factors are forced sitting posture and heavy physical work. Human response to whole-body vibration depends on factors promoting the development of degenerative changes such as constitution, previous spine disease and young age. The main problems in diagnosing whole-body vibration syndrome are differentiation of vibration induced disorders from age dependent changes of the spine and lack of a specific diagnostic method for assessing those changes. Therefore, only permanent medical surveillance can guarantee proper assessment of the damage induced by whole-body vibration. For vibration exposed workers preplacement and periodic examinations are recommended. Those should include a basic medical examination and an X-ray of the spine, or at least of its lumbar part.

Humans↗

Bioresponses in men after repeated exposures to single and simultaneous sinusoidal or stochastic whole body vibrations of varying bandwidths and noise.

This study deals with the changes in temporary hearing threshold (TTS2), upright body posture sway amplitudes in the X and Y direction, heart rate (HR), R-wave amplitude (RWA), systolic (SBP) and diastolic (DBP) blood pressure, pulse pressure (PP) and the index characterizing haemodynamic activity (HDI), when the subjects were exposed to noise alone, to vibrations alone or to simultaneous noise and vibrations. The experiments were carried out in an exposure chamber and the number of exposure combinations was 12. Seven healthy, male students volunteered as subjects, making a total number of 84 experiments. For each person the experiment consisted of a 30-min control period, five consecutive 16-min exposures, between which there was a 4-min measuring interval, and a 15-min recovery period. The noise was broadband (bandwidth 0.2-16.0 kHz) A-weighted (white) noise. The noise categories were: (1) no noise and (2) noise with an intensity of 90 dBA. The categories of low-frequency whole body vibration in the direction of the Z-axis were: (1) vibration within the range 4.4-5.6 Hz, (2) vibration within the range 2.8-5.6 Hz, (3) vibration within the range 2.8-11.2 Hz, (4) vibration within the range 1.4-11.2 Hz and (5) sinusoidal vibration with a frequency of 5 Hz. The (rms) acceleration in all the vibration models was 2.12 m/s2. The results showed that the TTS2 values at 4 and 6 kHz increased as a result of simultaneous exposure to noise and vibration significantly more than as a result of exposure to noise alone. The TTS2 values increased more intensely during the first 16-min exposure. The means of the variances in the amplitudes of body upright posture sway changed not only after exposures to vibration alone, but also after exposure to noise alone. The means of the sway variances in the X and Y directions at 0.1 Hz and within the range 0.06 to 2.00 Hz increased only when the vibration in the noise-vibration combination was sinusoidal. The changes in the heart rate, R-wave amplitude and blood pressure values also depended on the bandwidth of the vibration, the number of consecutive exposures and on whether the subjects were simultaneously exposed to noise in addition to vibration. As a rule, the effects of sinusoidal vibration differed from those due to stochastic vibrations.

Adult↗

Effects of leg muscle tendon vibration on group Ia and group II reflex responses to stance perturbation in humans.

Stretching the soleus (Sol) muscle during sudden toe-up rotations of the supporting platform in a standing subject evokes a short-latency response (SLR) and a medium-latency response (MLR). The aim of the present investigation was to further explore the afferent and spinal pathways mediating the SLR and MLR in lower limb muscles by means of tendon vibration. In seven subjects, toe-up or toe-down rotations were performed under: (1) control, (2) continuous bilateral vibration at 90 Hz of Achilles' tendon or tibialis anterior (TA) tendon, and (3) post-vibration conditions. Sol and TA background EMG activity and reflex responses were bilaterally recorded and analysed. Toe-up rotations induced SLRs and MLRs in Sol at average latencies of 40 and 66 ms, respectively. During vibration, the latency of both responses increased by about 2 ms. The area of the SLR significantly decreased during vibration, regardless of the underlying background activity, and almost returned to control value post-vibration. The area of Sol MLR was less influenced by vibration than SLR, the reduction being negligible with relatively high background activity. However, contrary to SLR, MLR was even more reduced post-vibration. Toe-down rotations induced no SLR in the TA, while a MLR was evoked at about 81 ms. The area of TA MLR decreased slightly during vibration but much more post-vibration. SLRs and MLRs were differently affected by changing the vibration frequency to 30 Hz: vibration had a negligible effect on the SLR, but still produced a significant effect on the MLR. The independence from the background EMG of the inhibitory effect of vibration upon the SLR suggests that vibration removes a constant amount of the Ia afferent input. This can be accounted for by either presynaptic inhibition of group Ia fibres or a 'busy-line' phenomenon. The differential effect of vibration on SLRs and MLRs is compatible with the notions that spindle primaries have a higher sensitivity to vibration than secondaries, and that group II afferent fibres are responsible for the production of the MLR. The decrease of MLRs but not SLRs after vibration is discussed in terms of an interaction between peripheral and central drive on group II interneurones in order to produce sufficient EMG activity to maintain a given postural set.

Achilles Tendon↗

Effect of whole-body vibration in the vertical axis on cortisol and adrenocorticotropic hormone levels in piglets.

Vibration, being a consequence of motion during transport, may impair the welfare of pigs. Therefore, the primary objectives of this study were 1) to evaluate during transport simulation the use of ACTH and cortisol plasma levels, which are part of a basic adaptation mechanism of pigs and 2) to define comfort conditions for pigs related to the frequency and acceleration of vibration. Pigs with a body weight between 20 and 25 kg were vibrated in the vertical direction for 2 h at 2, 4, 8, and 18 Hz, in combination with root mean square acceleration magnitudes of 1 or 3 m/s2. Blood was sampled at regular intervals before, during, and after vibration as the pig's behaviors were recorded. Data on ACTH, cortisol, and behavior could be collected from 104 vibrated pigs and 21 controls. In addition, eight animals (3 controls, 5 vibrated) were treated with 0.1 mg of dexamethasone/kg BW, eight animals (3 controls, 8 vibrated) with 0.1 mg naloxone/kg BW, and six (2 controls, 4 vibrated) with a physiological salt solution. Blood samples were taken and products were administrated via an intravenous catheter. The pigs spent less time lying during both hours of vibration treatment than during control conditions. Compared with 2 and 4 Hz, time spent lying was 10 times shorter at 8 Hz and 18 times shorter at 18 Hz. At 1030, ACTH levels were significantly higher than basal levels in animals vibrated at 2 (P < 0.0001), 4 (P < 0.002), and 18 Hz (P < 0.0006). After 1 h, levels returned to basal values. Cortisol levels increased very rapidly after the beginning of vibration (P < 0.0001) and remained higher until 1 h after cessation of vibration (P < 0.003). An inferrence of the lines of equal responses for ACTH and cortisol indicated that, in the beginning of vibration exposure, pigs were extremely susceptible to vibrations at lower frequencies (2 and 4 Hz), whereas at the end of vibration exposure the responses were higher at 18 Hz. The application of dexamethasone and naloxone underpinned the emotional component of the response strategy of pigs to vibration. Hence, vibration during transport should be minimized in order to enhance the adaptive capacities of pigs.

Adaptation, Physiological↗

[Observations of capillary fluid flow rate by vibration on the small vessel model].

The vibration hazards in peripheral blood vessels as an occupational origin is caused by using pneumatic vibrating tools. In order to know that the major part of causes is whether due to the direct effects of the physical vibration or due to the effects depended on the excitations of peripheral nervous system, an model experiment was employed to estimate the direct effect of the physical vibration. In our experiments, water as fluid was used instead of blood. The silicon capillary tube as same the physical qualities and conditions as blood vessels was vibrated by oscillator. The silicon capillary tube was exposed by following three type of vibration mode to flow axis; i) sine wave of transverse vibration, ii) rectangular wave of transverse vibration, and iii) sine wave of longitudinal vibration. The range of vibration frequency covered 1-2000 Hz. The averaged acceleration by oscillating vibration and the vibration strength level were estimated about 1-200 G and 150 dB, respectively. The observed decreases of water flow rate due to vibration extremely depend on frequency. The decrease ratio of water flow rate by vibration was at maximum 12% down compare with the cases of non vibration. In these observed results by this model experiment, it should be concluded that the direct effect of the physical vibration to the blood flow was not too strong to cause the actual vibration hazards.

Blood Circulation↗

Vibration syndrome in chipping and grinding workers.

A clear conclusion from these studies is that vibration syndrome occurs in chipping and grinding workers in this country and that earlier reports that it may not exist were probably inaccurate. The careful selection of exposed and control groups for analysis strengthens the observed association between vibration syndrome and the occupational use of pneumatic chipping hammers and grinding tools. In the foundry populations studied the vibration syndrome was severe, with short latencies and high prevalences of the advanced stages. The shipyard population did not display this pattern. This difference can be attributed to variations in work practices but the more important factor seems to be the effect of incentive work schedules. Comparisons of groups of hourly and incentive workers from the shipyard and within foundry populations consistently demonstrated that incentive work was associated with increased severity of vibration syndrome. Excessive vibration levels were measured on chipping and grinding tools. Of the factors studied, reduction of throttle level decreased the vibration levels measured on chipping hammers. For grinders, the working condition of the tool affected the measured vibration acceleration levels. Grinders receiving average to poor maintenance showed higher vibration levels. The results of objective clinical testing did not yield tests with diagnostic properties. To date, the clinical judgment of the physician remains the primary focus of the diagnosis of vibration syndrome. A number of actions can be taken to prevent vibration syndrome. Preplacement medical examinations can identify workers predisposed to or experiencing Raynaud's phenomenon or disease. Informing employees and employers about the signs, symptoms, and consequences of vibration syndrome can encourage workers to report the condition to their physicians promptly. Engineering approaches to preventing vibration syndrome include increased quality control on castings to reduce finishing time and automation of the finishing process. Tool manufacturers can contribute by modifying or redesigning tools to reduce vibration. The technology to reduce vibration from hand tools exists but the engineering application is difficult. Vibration from chain saws has been reduced through changes in design and some companies have begun to redesign jackhammers, scalers, grinders, and chipping hammers. As these become available, purchasers can encourage manufacturers by selecting tools with antivibration characteristics. Vibration from tools currently in use can be controlled by periodically scheduled inspection and maintenance programs for vibrating tools.(ABSTRACT TRUNCATED AT 400 WORDS)

Equipment Design↗

The relative sensitivity to vibration of muscle receptors of the cat.

1. Longitudinal vibration was applied to the de-efferented soleus muscle of anaesthetized cats while recording the discharge of single afferent fibres from the proprioceptors within the muscle. Conditions were defined under which vibration can be used to excite selectively the primary endings of muscle spindles without exciting the secondary endings of muscle spindles or Golgi tendon organs.2. Frequencies of vibration of 100-500 c/s were used. The maximum amplitude of vibration which the vibrator could produce fell with increasing frequency; it was 250 mu (peak to peak) for 100 c/s and 20 mu for 500 c/s.3. Primary endings of muscle spindles were very sensitive to vibration. Most could be ;driven' to discharge one impulse for each cycle of vibration over the whole of the above range of frequencies, provided the initial tension was moderate (20-200 g wt.). The amplitude of vibration required to produce driving usually varied by less than a factor of two over the whole range of frequencies. The most sensitive endings could be driven by vibrations of below 10 mu amplitude.4. Stimulation of single fusimotor fibres, whether static or dynamic fusimotor fibres, increased the sensitivity of primary endings to vibration. Contraction of the main muscle, produced by stimulating alpha motor fibres, reduced the sensitivity of primary endings even when fusimotor fibres were also being stimulated.5. The secondary endings were very insensitive to longitudinal vibration and with the amplitudes available not one of twenty-five endings could be driven at 150 c/s or above; one ending could be driven at 100 c/s by vibration of 250 mu amplitude. Stimulation of single fusimotor fibres, probably all of which were static fusimotor fibres, made them slightly more sensitive to vibration but none of them approached the sensitivity of the primary endings.6. The Golgi tendon organs were as insensitive as the secondary endings when the muscle was not contracting and none could be driven at any frequency in spite of quite high tensions in the muscle. However, when the muscle was made to contract by stimulating alpha fibres in ventral root filaments the tendon organs became appreciably more sensitive, the degree of sensitization increasing approximately with the strength of the contraction. They never became as sensitive as the primary endings, and with the amplitudes of vibration available none was driven at frequencies of over 250 c/s.7. When the amplitude of vibration was somewhat below that required to produce driving of an ending it still produced some increase in its mean frequency of discharge. However, amplitudes of vibration of 25-50 mu applied to a non-contracting muscle, whether with or without fusimotor stimulation, produced driving of nearly all primary endings without any significant increase in the mean frequency of firing of secondary endings or Golgi tendon organs. Such vibration can therefore be used as a specific stimulus for the primary endings in order to investigate the central effects or repetitive discharge of the Ia afferent fibres from them.8. Experiments on endings in the peroneus longus muscle showed that these behaved similarly to those in soleus.

Animals↗

Altered sensitivity of digital blood flow to acute vibration in patients with vasospastic disease.

Fifteen patients with primary Raynaud's, 18 patients with vibration induced white finger (VWF) and 15 controls were exposed to sine wave vibration, with an amplitude of 0.15 mm and frequencies of 40, 80 and 120 Hz. Baseline digital blood flow was measured using venous occlusion strain gauge plethysmography. A digit was vibrated for 1 min and subsequent blood flow measurements were taken from both vibrated and non-vibrated digits. Vibration at 40 Hz causes a significant decrease in flow in the vibrated digits of the control group only (P less than 0.05, Wilcoxon test). Vibration at 80 Hz shows a significant decrease in blood flow in the vibrated digits of both the control and the VWF groups (P less than 0.005) and also in the non-vibrated digits of the VWF group (P less than 0.05). Vibration at 120 Hz significantly decreases blood flow in the vibrated digits of normal control, VWF and Raynauds group (P less than 0.001). The Raynaud's non-vibrated digits also had decreased flow (P less than 0.005). These results imply that patients with established vasospastic disease are less sensitive to the direct effects of acute vibration than controls. The results also imply that vibration at 40, 80 and 120Hz affect digital blood flow in controls through local mechanism. Vibration at certain frequencies, appears to modulate blood flow in patients with vasospastic disease by acting through central mechanisms.

Adult↗

The responses of human muscle spindle endings to vibration of non-contracting muscles.

1. In micro-electrode recordings from the human peroneal and tibial nerves, the responses of thirty-two primary spindle endings, thirteen secondary spindle endings and three Golgi tendon organs were studied during vibration of the tendons of the receptor-bearing muscles in the leg. The amplitude of the applied vibration was 1-5 mm and the frequency was varied from 20 to 220 Hz. As checked with e.m.g. and torque measurements, the muscles of the leg were relaxed during the sequences analysed. 2. Providing that the vibrator was accurately applied, all endings responded with discharges phase-locked to the vibration cycles, the discharge rates being at the vibration frequency or at subharmonics of that frequency. The response to vibration was of abrupt onset and offset, was maintained for the duration of vibration, and was not subject to fluctuation with changes in attention or with remote muscle contraction. 3. The maximal discharge rate that could be achieved varied from one ending to the next, and increased with the length of the receptor-bearing muscle. For endings driven at their maximal rate an increase in vibration frequency produced a decrease in discharge rates as the ending changed to a subharmonic pattern of response. The converse occurred on decreasing vibration frequency. 4. For any given muscle length, primary endings could generally be driven to higher rates than secondary endings but there was a wide range of responsiveness within each group and a significant overlap between the groups. At medium muscle length, the most responsive primary endings could be driven up to 220 Hz but secondary endings did not reach discharge rates higher than 100 Hz. 5. With combined vibration and passive movements, primary endings exhibited maximal vibration responsiveness during the stretching phases, sometimes firing twice per vibration cycle. During the shortening phases, however, they usually ceased responding to the vibratory stimulus. The vibration responsiveness of secondary endings was not potentiated to the same extent by on-going muscle stretch or reduced to the same extent by on-going muscle shortening. Thus, during shortening, secondary endings may be more responsive than primary endings. 6. The responses of primary endings to tendon taps were reduced during muscle vibration, a reduction which probably contributes to vibration-induced suppression of tendon jerks. Additionally, as the muscle shortened after tendon percussion, there was a transient pause in the response to vibration.

Action Potentials↗

Acute effects of vibration on digital circulatory function in healthy men.

OBJECTIVES: To investigate the local and central pathophysiological mechanisms involved in the acute effects of unilateral vibration on the digital circulation of healthy men. METHODS: Finger blood flow (FBF) and finger skin temperature (FST) in thermoneutral conditions, and the percentage change in finger systolic pressure (FSP%) after local cooling from 30 to 10 degrees C were measured in the fingers of both hands in eight men (aged 23-47 years) who were not occupationally exposed to hand transmitted vibration. The right hand was exposed for 30 minutes to sinusoidal vibration with a frequency of 125 Hz and an acceleration of 87.5 m.s-2 rms (root mean square). A control condition consisted of exposure to static load only (10 N) without vibration. The measures of digital circulation were taken before exposure to vibration and static load and at 0, 30, 60, and 90 minutes after the end of each exposure. RESULTS: Exposure to static load caused no significant changes in FBF, FST, or FSP% in either the test right or the control left finger. Immediately after vibration exposure, there was a temporary increase in FBF in the vibrated right finger, whereas the non-vibrated left finger showed no vasodilation. In both the vibrated and non-vibrated fingers, FBF and FST were significantly reduced during the recovery time. A large variability between subjects was found for FBF and, to a lesser extent, for FST. In the vibrated right hand the decrease in FBF was significantly related to cold induced vaso-constriction in the digital vessels. Such a relation was not found in the non-vibrated left hand. CONCLUSIONS: The results of this investigation suggest that acute vibration can disturb the function of digital vessels through two different and opposite mechanisms. Vibration seems to produce local vasodilation and to trigger a central sympathetic reflex vasoconstriction that can be recorded in the ipsilateral and the contralateral finger to vibration. Both local and central vasoconstrictor mechanisms are likely to be involved in the responsiveness to cold found in the digital vessels of a vibrated finger.

Adult↗

Effect of chest wall vibration on ventilation in patients with spinal cord lesion.

Changes of respiration caused by chest wall vibration were studied in 13 patients with cervical cord lesions. Vibrators applied on the chest wall were intermittently triggered by the patient's respiratory movements. The vibrators were triggered to be applied in three ways. 1) Upper vibrations were bilaterally applied during inspiration on the 2nd or 3rd parasternal intercostal spaces (insp "in-phase" vibration). 2) Lower vibrations were bilaterally applied during expiration on the 7th-to 10th intercostal spaces anterior to midaxillary lines (exp "in-phase" vibration). 3) Inspiratory and expiratory vibrations were combined to produce alternating in phase vibration. Both inspiratory and expiratory vibrations increased tidal volume (VT), but the alternating in-phase vibration increased it to significantly higher values (P less than 0.05). Minute volume of ventilation (VE l/min) also increased with insp or exp in-phase vibration. The alternating in-phase vibration increased VE l/min to even higher values (P less than 0.05). The responses described probably depend on segmental vibration reflexes arising in the inspiratory and expiratory intercostal muscles underlying the vibrators. The alternating in-phase vibration may well be useful to improve the breathing in patients with respiratory insufficiency.

Adolescent↗