Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Titanium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17Linked to original sources

Intracellular localization of titanium within xenografted sensitive human tumors after treatment with the antitumor agent titanocene dichloride.

In the present study, the intracellular localization of titanium was analyzed in three xenografted human adenocarcinomas of the colon sigmoideum (S 90), the stomach (M-Stg 4), and the lung (L 261) in dependence on the time after application of a single therapeutic dose (80 mg/kg) of the organometallic antitumor agent titanocene dichloride (C5H5)2TiCl2. The investigations were performed by use of electron energy loss spectroscopy (EELS), a method which allows microanalysis in ultrathin sections, in combination with electron spectroscopic imaging (ESI), which offers the possibility to image the two-dimensional localization and distribution of light- and medium-weight elements in animal tissues. In all three tumors which were studied, titanium was at first detected within the nucleus and, some hours and days later, it was additionally found in cytoplasmic lysosomes. In the colon and lung tumors S 90 and L 261, already 12 hr after treatment, titanium was traceable as tender granules in the nuclear chromatin. During the following days, it was then accumulated in certain areas of the nuclear heterochromatin and, in the case of the L 261 tumor, also in the nucleolus. Maximum concentrations were attained in the nuclei and nucleoli at 48 hr after substance application. Thereafter, titanium was increasingly incorporated into cytoplasmic lysosomes which are known to be involved in intracellular degrading and digesting processes and which occurred in increased numbers in treated tumor cells. Regarding the stomach carcinoma M-Stg 4, titanium was recognized in the nuclear heterochromatin only 1 and 2 days after application of titanocene dichloride. At 48 hr, it was additionally detected in cytoplasmic lysosomes. In all cases where titanium was found accumulated in the nucleus and in lysosomes, phosphorus was simultaneously enriched in a similar local distribution and a concentration which even exceeded that within phosphorus-rich areas, e.g., the nuclear heterochromatin and cytoplasmic ribosomes. These results confirm a primary interaction of titanium-containing metabolites deriving from titanocene complexes with nucleic acid molecules, especially with nuclear DNA. They suggest the formation of aggregates between nucleic acids and titanium-containing metabolites which are obviously extruded out of the nuclei and incorporated into cytoplasmic lysosomes, known to be involved in intracellular digesting processes.

Adenocarcinoma↗

Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws.

PURPOSE: The aim of part 1 of this study was to compare the structural properties of tibia-graft-interference screw constructs of soft-tissue graft fixation via the anterior cruciate ligament (ACL) by use of different interference screws. In part 2 the influence of graft laceration as a result of 1 single interference screw insertion on the mechanical properties of the graft was evaluated. METHODS: In part 1 of the study, in a bovine knee model, soft-tissue graft fixation with titanium, biodegradable poly-D,L-lactide (PLDLA), and PLDLA-tricalcium phosphate (TCP) interference screws was performed, and the structural properties were determined by use of a materials testing machine at a rate of 12.5 mm/s. In part 2 the bone was cut after 1 single insertion of titanium, PLDLA, or PLDLA-TCP interference screws, and the mechanical properties of the graft were determined. RESULTS: Soft-tissue graft fixation with a biodegradable PLDLA interference screw showed a statistically significantly higher maximum load when compared with PLDLA-TCP and titanium interference screws. PLDLA-TCP screw fixation revealed a significantly higher ultimate load than titanium screw fixation. The mechanical properties of the grafts after 1 single insertion of PLDLA-TCP interference screws showed a statistically significantly higher stiffness, yield load, and maximum load when compared with the PLDLA and titanium interference screw groups. CONCLUSIONS: The results of this study suggest that the use of a titanium screw to fix a soft-tissue graft in cruciate ligament reconstruction surgery may cause damage to the graft. Soft-tissue ACL reconstruction fixed with a PLDLA interference screw resulted in a significantly higher pullout strength than ACL reconstructions fixed with a PLDLA-TCP or titanium interference screw. CLINICAL RELEVANCE: In contrast to fixation with a biodegradable interference screw, fixation with a titanium interference screw may damage the integrity of a soft-tissue graft in cruciate ligament reconstruction and should therefore be avoided.

Absorbable Implants↗

Characterization of titanium surfaces with calcium and phosphate and osteoblast adhesion.

The titanium surfaces containing calcium, phosphate ions and the carbonate apatite were characterized. The effect of surface chemistry on the initial rabbit osteoblast response on these surfaces was investigated. The cell count and alkaline phosphatase (ALP) specific activity assay were used for biochemical analyses. Scanning electron microscopy was used for morphology observation and in particular X-ray photoelectron spectroscopy (XPS) for surface chemistry characterization. The number of cells adhering to the apatite coating surface was the maximum, the number of cells on the surface containing calcium without phosphate ions was higher than that containing phosphate without calcium, and the number on the unmodified titanium surface was the least. The osteoblasts cultured on the apatite surface exhibited the highest ALP specific activity, next were the ones on the surface containing solely calcium, the lowest were on the unmodified titanium surface. On the substrate surfaces removed of adhered cells, the order of nitrogen amounts detected by XPS was consistent with ones of ALP specific activity and cell number, except for the unmodified titanium surface. For the substrate surfaces removed of adhered osteoblasts, XPS analysis showed that calcium and phosphorous amounts decreased during cell adhesion. After cell culture the Ca2p binding energy (BE) values for apatite coating and the surface containing solely calcium were similar to those of the two surfaces adsorbed bovine serum albumin (BSA). The P2p BE values for the surfaces containing phosphate ions, including the apatite coating and the surface containing solely phosphate ions, showed the same change. But after cell culture the decrease of the P2p BE value for the coating surface was larger than the one for the surface containing solely phosphate ions. Considering the bovine serum albumin adsorption on the same samples, these results indicated that calcium ions on titanium surfaces play a more important role than phosphate ions in initial interactions among culture medium, osteoblasts and titanium surfaces. On the apatite coating surface, calcium ions are active sites for osteoblast adhesion, while calcium and phosphate ions co-exist on titanium surfaces, the former promotes the osteoblast adhesion onto the phosphate sites on titanium surfaces. The cell adhesion was a complicated biological and chemical process relating to surface several elements similar to protein adsorption.

Animals↗

The modulation of osteogenesis in vitro by calcium titanium phosphate coatings.

Calcium phosphate coated titanium and titanium alloy are widely used as dental and orthopaedic implants. This study examines the effect of novel calcium titanium and calcium titanium zirconium phosphates suitable for plasma-spraying onto titanium substrata on the expression of bone-related genes and proteins by human bone-derived cells (HBDC) and compares this behavior to that on native titanium and hydroxyapatite-coated titanium. Test materials were an acid etched and sand-blasted titanium surface (Ti-DPS), a plasma-sprayed hydroxyapatite coating (HA), and five materials which were created from CaTi(4)(PO(4))(6) (CTP) and CaZr(4)(PO(4))(6) (CZP): sintered CaTi(4)(PO(4))(6) (CTP-S1), sintered 46CaO.23TiO(2).31P(2)O(5) (CTP-S2), sintered CaTiZr(3)(PO(4))(6), (CTZP-S1), sintered 46CaO.23ZrO(2).31P(2)O(5) (CTZP-S2) and sintered 55CaO.20TiO(2).31P(2)O(5) (CTP-S3). HBDC were grown on the substrata for 3, 7, 14 and 21 d, counted and probed for various mRNAs and proteins (type I collagen, osteocalcin, osteopontin, osteonectin, alkaline phosphatase and bone sialoprotein). All substrates significantly affected cellular growth and the temporal expression of an array of bone-related genes and proteins. At 14 and 21 d, cells on CTP-S3 displayed significantly enhanced expression of all osteogenic mRNAs. Surfaces of CTP-S1 and CTP-S3 had the most effect on osteoblastic differentiation inducing a greater expression of an array of osteogenic markers than recorded for cells grown on Ti-DPS and HA, suggesting that these novel materials may possess a higher potency to enhance osteogenesis.

Alkaline Phosphatase↗

Differential inflammatory macrophage response to rutile and titanium particles.

Titanium and its alloys are widely used as implant materials for dental and orthopaedic applications due to their advantageous bulk mechanical properties and biocompatibility, compared to other metallic biomaterials. In order to improve their wear and corrosion resistance, several surface modifications that give rise to an outer ceramic layer of rutile have been developed. The ability of rutile wear debris to stimulate the release of inflammatory cytokines from macrophages has not been addressed to date. We have compared the in vitro biocompatibility of sub-cytotoxic doses of rutile and titanium particles in THP-1 cells driven to the monocyte/macrophage differentiation pathway as well as in primary cultures of human macrophages. Confocal microscopy experiments indicated that differentiated THP-1 cells and primary macrophages efficiently internalised rutile and titanium particles. Treatment of THP-1 cells with rutile particles stimulated the release of TNF-alpha, IL-6 and IL-1beta to a lesser extent than titanium. The influence of osteoblasts on the particle-induced stimulation of TNF-alpha and IL-1beta was analysed by co-culturing differentiated THP-1 cells with human primary osteoblasts. Under these conditions, secretion levels of both cytokines after treatment of THP-1 cells with rutile particles were lower than after exposure to titanium. Finally, we observed that primary macrophages released higher amounts of TNF-alpha, IL-6 and IL-1beta after incubation with titanium particles than with rutile. Taken together, these data indicate that rutile particles are less bioreactive than titanium particles and, therefore, a higher biocompatibility of titanium-based implants modified with an outer surface layer of rutile is expected.

Biocompatible Materials↗

Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate.

OBJECTIVE: To determine the adhesion at the titanium-porcelain interface using a fracture mechanics approach, and to investigate the bonding mechanism using SEM. METHODS: Specimens of five different titanium-porcelain and one base metal-porcelain bonding systems were prepared for a four-point bending interfacial delaminating test on a universal testing machine. The pre-cracked specimen was subjected to load and the strain energy release rate (G, J/m(2)) was calculated from the critical load to induce stable crack extension in each system. The interface for the various materials was investigated in an SEM and compared. RESULTS: The titanium-porcelain with Gold Bonder showed the highest G-value (72.39+/-13.21J/m(2)) among the groups whilst titanium-porcelain with cross-cut-bur preparation showed the lowest (5.78+/-1.39J/m(2)). The former was significantly higher than that of Wiron 99 (base-metal, BEGO, Germany) porcelain (40.01+/-6.67J/m(2)), a clinically accepted bonding system for many years. The G-values of porcelain fused to titanium-Rocatec, titanium-sandblasted and/or titanium-GC-Bonder were 10.81+/-1.49, 12.64+/-3.01 and 35.74+/-5.20J/m(2), respectively. SEM images of the interface fracture crack path for the different bonders enabled the mechanisms responsible for the differences in strain energy release rates to be appreciated. CONCLUSION: The strain energy release rate (G) of titanium-porcelain with a Gold Bonder interface layer was highest among the five different systems.

Adhesives↗

A randomized controlled trial of resorbable versus titanium fixation for orthognathic surgery.

OBJECTIVES: To determine any differences in the intra- and postoperative morbidities and complications between resorbable and titanium plating systems for fixation in orthognathic surgery. STUDY DESIGN: This prospective randomized clinical trial was conducted in the Oral and Maxillofacial Surgery unit of the University of Hong Kong. Patients with dentofacial deformities were randomly assigned into the titanium and resorbable fixation groups. Intraoperative data such as the surgical procedures, time for fixing each plate, and number of broken plates and screws were recorded. Subjective and objective parameters related to clinical morbidities were assessed postoperatively. RESULTS: A total of 60 patients with 177 osteotomies were included in this study. Eighty-seven osteotomies fixated with 196 titanium plates and 784 titanium screws were performed in 30 patients, whereas 90 osteotomies fixated with 165 resorbable plates and 658 resorbable screws were done in another 30. The postoperative infection rate was 1.53% (3/196) and 1.82% (3/165) in the titanium and resorbable fixation groups, respectively. These infections were mainly due to loose screws and wound dehiscence. The plate exposure rate was 1.02% (2/196) for the titanium group and 1.21% (2/165) for the resorbable group. The plate removal rate in the titanium and resorbable groups was 1.53% (3/196) and 3.63% (6/165), respectively. Statistically significant difference was shown in the plating time of step (mandibular body) and Hofer (mandibular subapical) osteotomies. There was no significant difference in the subjective clinical parameters such as wound discomfort, clinical stability of the osteotomy segments, palpability of plate, and overall satisfaction of the results between the 2 fixation groups. Similarly, objective parameters including wound dehiscence, rate of infection, plate exposure, occurrence of sinus tract, and palpability assessed by surgeons in both groups also showed no significant difference. CONCLUSION: Bioresorbable fixation devices offer similar function as titanium in fixation for orthognathic surgery and do not impose an increase in the clinical morbidities.

Absorbable Implants↗

Effect of a titanium surface on bone marrow-derived osteoblastic cells in vitro.

The initial interaction between a titanium implant and the surrounding cancellous bone tissue was investigated by means of in vitro cultures of bone marrow-derived osteoblastic clone TMS-12 cells. Proliferation of TMS-12 cells cultured on a titanium surface was significantly reduced compared with that of control cells cultured directly on plastic, but alkaline phosphatase activity was the same as control cells. Co-culture of spleen cells with TMS-12 cells in the presence of a 1 alpha,25-dihydroxyvitamin D3 on titanium resulted in significant inhibition of tartrate-resistant acid phosphatase activity compared to control cultures on plastic. More prostaglandin E2 (PGE2) was produced by cells grown on a titanium surface than on plastic tissue-culture plates. On the other hand, mouse calvaria-derived osteogenic MC3T3-E1 cells, known to proliferate well on titanium, released similar amounts of PGE2 on titanium surfaces as on plastic tissue culture plates, indicating additional marked differences between the two osteoblastic cell types in response to a titanium surface. These results suggest that the reaction of bone marrow-derived osteoblastic cells to a titanium surface may fundamentally differ from that of calvaria-derived osteoblastics even though both cells are from bone tissue.

Animals↗

Joining titanium materials with tungsten inert gas welding, laser welding, and infrared brazing.

Titanium has a number of desirable properties for dental applications that include low density, excellent biocompatibility, and corrosion resistance. However, joining titanium is one of the practical problems with the use of titanium prostheses. Dissolved oxygen and hydrogen may cause severe embrittlement in titanium materials. Therefore the conventional dental soldering methods that use oxygen flame or air torch are not indicated for joining titanium materials. This study compared laser, tungsten inert gas, and infrared radiation heating methods for joining both pure titanium and Ti-6Al-4V alloy. Original rods that were not subjected to joining procedures were used as a control method. Mechanical tests and microstructure analysis were used to evaluate joined samples. Mechanical tests included Vickers microhardness and uniaxial tensile testing of the strength of the joints and percentage elongation. Two-way analysis of variance and Duncan's multiple range test were used to compare mean values of tensile strength and elongation for significant differences (p < or = 0.05). Tensile rupture occurred in the joint region of all specimens by cohesive failure. Ti-6Al-4V samples exhibited significantly greater tensile strength than pure titanium samples. Samples prepared by the three joining methods had markedly lower tensile elongation than the control titanium and Ti-6Al-4V rods. The changes in microstructure and microhardness were studied in the heat-affected and unaffected zones. Microhardness values increased in the heat-affected zone for all the specimens tested.

Alloys↗

Margin quality of titanium and high-gold inlays and onlays--a clinical study.

OBJECTIVES: Unalloyed titanium may be an economical substitute for gold alloys. The purpose of this study was to evaluate the suitability of unalloyed titanium as an alternative to gold alloys for posterior inlay and onlay restorations. METHODS: Fifty-four patients received 99 titanium restorations, 56 patients 96 gold alloy restorations. All titanium restorations were cast in a vacuum-pressure casting machine. Two weeks after insertion the clinical margin integrity was evaluated by replica technique. The maximum marginal gaps were assessed under the optical measuring microscope. The two tailed t-test for independent samples was used for statistical analysis. RESULTS: Accuracy of fit was significantly better in gold alloy than in titanium restorations. Mean maximum marginal gap between restoration margin and tooth structure were 72 +/- 18 microns (mean +/- S.D.) for titanium and 64 +/- 18 microns (mean +/- S.D.) for gold restorations. SIGNIFICANCE: Though marginal gap widths in titanium restorations did not yet match the gold standard, the data justify the use of titanium as an alternative to gold alloy for inlay and onlay restorations.

Adolescent↗

Soft tissue findings above submerged titanium implants--a histological and spectroscopic study.

The aim of this study was to check the titanium level within the muco-periosteal flaps covering submerged titanium implants. The investigated material included 38 biopsies taken after 2.4-18 months (mean: 5.9) after implant insertion. Due to the evident time delay between implantation and taking the biopsy any influence of the implantation trauma itself was excluded. The implants came from the following producers: HaTi (Matthys, Switzerland), ITI (Straumann, Switzerland) and Branemark (Nobelbiocare. Sweden). The surface areas of these implants differ in size and structure. A comparison between the titanium impregnation of the investigated biopsies did not demonstrate any remarkable influence of the surface differences. This can be explained by the fact that only the top diameter and not the implant surface as a whole was the contact area with the excised tissue. Titanium in the biopsies was analysed in terms of its effect histologically and regarding the titanium quantity by spectrophotometry. Even the highest titanium contamination was without a negative effect on the muco-periosteal cover flaps. A correlation between time delay between implantation and biopsy or of the titanium amount and tissue reactions was not demonstrable. In summary, the results again highlighted the biological acceptance of titanium.

Biocompatible Materials↗

Element release from titanium devices used in oral and maxillofacial surgery.

Optical microscopy, scanning electron microscopy and X-ray microanalysis (EDS system) were used on c.p. titanium devices (21 grids and 10 plates) removed from 28 patients without signs of inflammation 6-24 months after surgery. Plates, grids and surrounding tissue were investigated to evaluate the titanium release and accumulation. Titanium was only present in the interfacial bone, probably due to fretting, and in all fibrous tissue surrounding the devices. Titanium content followed a decreasing gradient extending from the device surface and was not detected at a distance greater than 1mm. High titanium levels were found in blood cells in the connective tissue. In conclusion, titanium release from the devices stops only after bone is laid down on the titanium surfaces. Titanium release does not seem to interfere with the osteogenic process but perhaps may interact with it.

Bone Plates↗

Observations on the effect of BMP-2 on rat bone marrow cells cultured on titanium substrates of different roughness.

The objective of this study was to examine the osteoinductive capacity of different concentrations of BMP-2 on bone marrow stromal cells in vitro. Further, we intended to determine whether titanium provided with an increased surface roughness is more efficient in osteoblast differentiation than machined titanium. Therefore, 20,000 cells/ml were seeded and cultured on machined and grit-blasted titanium discs for 4, 8 and 16 days. Different concentrations of rhBMP-2 (0, 10, 100, 1000 ng/ml) were supplemented to the medium for 8 days of culturing. To evaluate cellular proliferation and differentiation, specimens were examined for DNA, alkaline phosphatase activity, and calcium content. Morphological appearance of the specimens at 8 and 16 days of incubation was evaluated using scanning electron microscopy. Two separate experimental runs were performed. Evaluation of the DNA and alkaline phosphatase data revealed that a significant difference existed for these data between both experimental runs. Further analysis of the DNA figures learned that roughening of the titanium surface and addition of BMP-2 had no effect on cell proliferation. The alkaline phosphatase analysis and calcium measurements revealed that BMP-2 stimulated the early differentiation of osteogenic cells on machined titanium substrates in a dose-dependent manner. After 16 days of culture, no significant differences in calcium content could be observed anymore between machined and roughened titanium surfaces. Further, the data revealed that the machined surfaces showed a significant increase in calcium deposition when 100 and 1000 ng/ml BMP-2 were supplemented to the medium. However, the roughened surfaces showed this significant enhancement in calcium content only with 1000 ng/ml BMP-2. In addition, SEM evaluation revealed a dose-dependent response to BMP-2. Increasing BMP-2 concentrations resulted in more calcified globular accretions on bone surfaces than when no BMP-2 was added. On the basis of our results, we conclude that (1) due to the heterogeneous nature of bone marrow, experimental results with primary rat bone marrow cells are difficult to reproduce from one experiment to the other, and (2) addition of rhBMP-2 in the medium stimulates the early differentiation and matrix mineralization of osteogenic cells on machined titanium surfaces in a dose-responsive manner. Further, we concluded that our roughened titanium surfaces had no effect on proliferation and differentiation of primary derived rate bone marrow cells.

Alkaline Phosphatase↗

Characterization of surface oxide films on titanium and adhesion of osteoblast.

The relationship between surface characteristics of titanium and initial interactions of titanium-osteoblasts was investigated. Titanium plates were heat-treated in different oxidation atmospheres. The third passage rabbit osteoblasts were cultured on the titanium plates for 24h. After the heat-treatment, the crystal structure of the surface oxide films on titanium was identified using X-ray diffractometer and X-ray photoelectron spectroscopy (XPS). The surface roughness of titanium was measured with a profilometer. The surface energy was obtained by measurement of contact angles and calculation with Owens-Wendt-Kaeble's equation. The amount of surface hydroxyl (OH)(s) groups was examined using XPS. The change of binding energy of the some elements on the substrate surface suggested that the interactions between the cells and the titanium involved chemical reactions. The greater surface roughness, higher surface energy and more surface hydroxyl groups resulted in greater numbers of adhered osteoblasts and higher cell activity. Compared to the acidic hydroxyl (OH)(a) groups in (OH)(s) groups and the dispersion component of the total surface energy, the basic hydroxyl (OH)(b) groups and the polar component play more important roles in the osteoblast-titanium interaction.

Alkaline Phosphatase↗

Characterization and protein-adsorption behavior of deposited organic thin film onto titanium by plasma polymerization with hexamethyldisiloxane.

Plasma polymerized hexamethyldisiloxane (HMDSO) thin film was deposited onto titanium using a radio-frequency apparatus for the surface modification of titanium. A titanium disk was first polished using colloidal silica at pH=9.8. Plasma-polymerized HMDSO films were firmly attached to the titanium by heating the titanium to a temperature of approximately 250 degrees C. The thickness of the deposited film was 0.07-0.35mum after 10-60min of plasma polymerization. The contact angle with respect to double distilled water significantly increased after HMDSO coating. X-ray photoelectron spectroscopy revealed that the deposited thin film consisted of Si, C, and O atoms. No Ti peaks were observed on the deposited surface. The deposited HMDSO film was stable during 2-weeks immersion in phosphate buffer saline solution. Fourier transform reflection-absorption spectroscopy showed the formation of Si-H, Si-C, C-H, and Cz.dbnd6;O bonds in addition to Si-O-Si bonds. Quartz crystal microbalance-dissipation measurement demonstrated that the deposition of HMDSO thin films on titanium has a benefit for fibronectin adsorption at the early stage. In conclusion, plasma polymerization is a promising technique for the surface modification of titanium. HMDSO-coated titanium has potential application as a dental implant material.

Adsorption↗

Preparation of bioactive titanium metal via anodic oxidation treatment.

Titania with specific structures of anatase and rutile was found to induce apatite formation in vitro. In this study, anodic oxidation in H(2)SO(4) solution, which could form anatase and rutile on titanium metal surface by conditioning the process, was employed to modify the structure and bioactivity of biomedical titanium. After the titanium metal was subjected to anodic oxidation treatment, thin film X-ray diffraction and scanning electron microscopy results showed the titanium metals surfaces were covered by porous titania of anatase and/or rutile. In simulated body fluid (SBF), the titanium anodically oxidized under the conditions with spark-discharge could induce apatite formation on its surface. The induction period of apatite formation was decreased with increasing amount of either anatase or rutile by conditioning the anodic oxidation. After the titanium metal, anodically oxidized under the conditions without spark-discharge, was subjected to heat treatment at 600 degrees C for 1 h, it could also induce apatite formation in SBF because the amount of anatase and/or rutile was increased by the heat treatment. Our results showed that induction of apatite-forming ability on titanium metal could be attained by anodic oxidation conjoined with heat treatment. So it was believed that anodic oxidation in H(2)SO(4) solution was an effective way to prepare bioactive titanium.

Apatites↗

Photokilling of T-24 human bladder cancer cells with titanium dioxide.

A photoexcited titanium dioxide surface has a strong ability to decompose water into hydrogen and oxygen. We have studied this effect in order to use it to kill cancer cells in vitro and in vivo. A distinct cell killing effect was observed on cultured T-24 human bladder cancer cells treated with titanium dioxide particles and 300-400 nm UV light irradiation. Titanium dioxide plus UV light also dramatically suppressed the tumour growth of T-24 cells that were implanted in nude mice. Cells cultured on the titanium dioxide electrode were also killed under UV irradiation when the electrode was anodically polarised, suggesting that photogenerated holes are involved in the cell killing. The cell killing effect caused by titanium dioxide particles plus UV light irradiation was significantly hampered in the presence of L-cysteine and catalase, scavengers of hydroxyl radicals and hydrogen peroxide respectively. Transmission electron microscopic observations showed the titanium dioxide particles to be distributed on the cell surface and inside the cells. These results suggest that titanium dioxide particles under UV light irradiation produced photogenerated holes on the surface yielding hydroxyl radicals and hydrogen peroxide inside or outside the cells and the cells were then killed by the action of these highly oxidising molecules. The possible application of photoexcited titanium dioxide particles to cancer treatment as a new anti-cancer modality is discussed.

Catalase↗

Effects of an Er:YAG laser and the Vector ultrasonic system on the biocompatibility of titanium implants in cultures of human osteoblast-like cells.

The aim of the present study was to investigate the effects of an Er:YAG laser (ERL) and the Vector ultrasonic system (VS) on the biocompatibility of titanium implants in cultures of human osteoblast-like cells (SAOS-2). One hundred and sixty-eight titanium discs with four different surfaces (sand-blasted and acid-etched, titanium plasma-sprayed, machine-polished, and hydroxyapatite-coated) were used to evaluate cell attachment. The samples were equally and randomly assigned to the following groups: (1) an ERL at an energy level of 100 mJ/pulse and 10 Hz using a special application tip, (2) the VS using carbon fibre tips, or (3) untreated control (C). The discs were placed in culture plates, covered with a solution of SAOS-2 cells, and incubated for 7 days. The specimens were then washed with phosphate buffer to remove cells not attached to the surface, and the adherent cells were stained with hematoxilin-eosin. Cells were counted using a reflected light microscope and the cell density per mm2 was calculated. Additionally, cell morphology and surface alterations of the titanium discs after treatment were investigated using scanning electron microscopy (SEM). All titanium discs treated with ERL demonstrated nearly the same cell density per mm2 as the untreated C surfaces. There was a significant decrease in the number of cells that attached to the implant surfaces treated with VS. The SEM examination showed no visible differences between lased and C titanium surfaces. All surfaces treated with VS showed conspicuous surface damage and debris of the used carbon fibres. The results of the present study indicate that (i) ERL does not damage titanium surfaces and subsequently does not influence the attachment rate of SAOS-2 cells, and (ii) VS, used with this type of carbon fibre tip, does not seem to be suitable for the instrumentation of titanium surfaces.

Biocompatible Materials↗